{"title":"Oscilloscopes","description":"\u003cstrong\u003eOscilloscopes are essential electronic test instruments used to measure and visualize electrical signals over time. \u003c\/strong\u003eThey enable engineers, technicians, educators and hobbyists to analyze waveforms, troubleshoot circuits, verify designs, and diagnose performance issues across a wide range of electronic applications. Available in digital, mixed-signal, handheld, and PC-based configurations, modern oscilloscopes support everything from classroom learning and equipment repair to advanced research and product development.\u003cbr\u003e\n\u003cp data-is-only-node=\"\" data-is-last-node=\"\" data-end=\"1098\" data-start=\"529\"\u003e\u003cspan data-state=\"closed\" class=\"\"\u003e\u003c\/span\u003e\u003cstrong\u003eOscilloscopes from \u003cmeta charset=\"utf-8\"\u003eUni-T combine dependable performance with exceptional value, making them the perfect choice for both professionals and electronics enthusiasts alike.\u003c\/strong\u003e Featuring a variety of bandwidths, sampling rates, deep memory options and advanced triggering functions, UNI-T offers solutions tailored to diverse testing requirements. Whether you're debugging embedded systems, maintaining industrial equipment, or building your skills in electronics, UNI-T oscilloscopes provide the tools needed to capture and analyze signals with confidence.\u003c\/p\u003e\n\u003cp data-is-only-node=\"\" data-is-last-node=\"\" data-end=\"1098\" data-start=\"529\"\u003e\u003cstrong\u003eAlso see: \u003ca href=\"https:\/\/sperdirect.com\/collections\/electrical-meters\"\u003eMultimeters + Voltage Testers\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e","products":[{"product_id":"ut-p30-100-mhz-10-1-100-1-differential-oscilloscope-probe","title":"UT-P30 100 MHz 10:1\/100:1 Differential Oscilloscope Probe","description":"\u003ch1\u003e100 MHz differential oscilloscope probe (10:1\/100:1 attenuation) for safely measuring floating voltages across motor drives, power converters and bridge circuits.\u003c\/h1\u003e\n\u003cp\u003e\u003cstrong\u003eCompatible with UNI-T oscilloscopes and most oscilloscopes with BNC inputs.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e100MHz Bandwidth\u003c\/strong\u003e — Captures signal content up to 100MHz for accurate waveform measurement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e10:1\/100:1 Attenuation\u003c\/strong\u003e — Divides the input signal for measuring higher-voltage circuits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e800Vpp Maximum Input Voltage\u003c\/strong\u003e — Rated input voltage for safe operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard BNC Connection\u003c\/strong\u003e — Compatible with UNI-T oscilloscopes and most oscilloscopes with BNC inputs.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCAT Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCAT III\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e69 × 26 × 165 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBandwidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe Attenuation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10:1, 100:1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe Max Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800Vpp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRise Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.5ns\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Capacitance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.3 pF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Impedance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 MΩ \/ 1.3 pF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 °C - 50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDifferential Input Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800Vpp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommon Mode Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5kVrms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCMRR\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 80 dB @ 60 Hz, \u0026gt; 60 dB @ 100 Hz, \u0026gt; 50 dB @ 1 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"Uni-Trend US","offers":[{"title":"Default Title","offer_id":53265475764448,"sku":"190500300014","price":399.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/UT-P30_1_sq.jpg?v=1782858082"},{"product_id":"ut-p36-100-mhz-200-1-500-1-differential-oscilloscope-probe","title":"UT-P36 100 MHz 200:1\/500:1 Differential Oscilloscope Probe","description":"\u003ch1\u003e100 MHz differential oscilloscope probe (200:1\/500:1 attenuation) for safely measuring floating voltages across motor drives, power converters and bridge circuits.\u003c\/h1\u003e\n\u003cp\u003e\u003cstrong\u003eCompatible with UNI-T oscilloscopes and most oscilloscopes with BNC inputs.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e100MHz Bandwidth\u003c\/strong\u003e — Captures signal content up to 100MHz for accurate waveform measurement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e200:1\/500:1 Attenuation\u003c\/strong\u003e — Attenuation ratio suited to the probe measurement range.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e560VDC+PeackAC \/ 5600VDC+Peak AC, Accuracy: 2% Maximum Input Voltage\u003c\/strong\u003e — Rated input voltage for safe operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard BNC Connection\u003c\/strong\u003e — Compatible with UNI-T oscilloscopes and most oscilloscopes with BNC inputs.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCAT Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCAT I 2800 V \/ CAT II 1400 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e160 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-10 °C - 45 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBandwidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe Attenuation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200:1, 2000:1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe Max Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5600Vpp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRise Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.5ns\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30cm input \/ 90cm output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Capacitance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 pF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 °C - 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNoise\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ 1.5mVrms (1\/200); ≤ 1mVrms (1\/2000)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDifferential Input Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5600Vpp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommon Mode Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2800Vrms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCMRR\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≥ 80 dB DC, ≥ 60 dB 100 Hz, ≥ 50 dB 1 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Uni-Trend US","offers":[{"title":"Default Title","offer_id":53265475731680,"sku":"190500100122X","price":459.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/UT-P36_1_sq.jpg?v=1782858082"},{"product_id":"upo1204-200-mhz-4ch-digital-storage-oscilloscope","title":"UPO1204 200 MHz 4Ch Digital Storage Oscilloscope","description":"\u003ch1\u003eThe UNI-T UPO1204 is a 200 MHz, four-channel digital storage oscilloscope with 2 GSa\/s real-time sample rate, 56 Mpts memory depth and a 500,000 wfms\/s waveform capture rate (Fast Acquire mode).\u003c\/h1\u003e\n\u003cp\u003eUltra Phosphor 2.0 display technology drives 256-level intensity grading on a 7-inch WVGA TFT LCD, making it straightforward to distinguish frequent signal behavior from rare anomalies at a glance.\u003c\/p\u003e\n\u003cp\u003eFour channels, 56 Mpts of memory, an independent DVM module, an enhanced 1 Mpts FFT, and three serial bus protocols decoded as standard — features that typically migrate to mid-tier scopes. The UPO1204 keeps them on the value-tier bench, which is the value proposition for teaching labs running twenty stations and engineering teams sourcing a second scope without sacrificing capability.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e200 MHz bandwidth, 4 channels\u003c\/strong\u003e — 2 GSa\/s real-time sample rate (2 GSa\/s on a single channel; 1 GSa\/s on two; 500 MSa\/s on all four), ≤ 1.8 ns calculated rise time.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e56 Mpts memory depth\u003c\/strong\u003e — capture full switching cycles and long protocol sequences without trading sample rate for record length.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e500,000 wfms\/s waveform capture rate\u003c\/strong\u003e — Ultra Phosphor 2.0 with 256-level intensity grading, in Fast Acquire mode. Fast enough to surface intermittent events that slower scopes spend hours missing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e1 Mpts enhanced FFT\u003c\/strong\u003e — frequency-domain analysis with frequency setting, demodulation mode, waterfall display, and marker measurement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndependent DVM module\u003c\/strong\u003e — dedicated AC\/DC True RMS digital voltmeter, operating in parallel with scope acquisition.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e7-digit hardware frequency counter\u003c\/strong\u003e — hardware-accelerated counter alongside the scope channels.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e3 serial bus decoders standard\u003c\/strong\u003e — RS-232\/UART, I²C, and SPI trigger and decode included; full-memory hardware decoding turns multi-second decode times into milliseconds.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e36 automated measurements\u003c\/strong\u003e — time, voltage, frequency, and statistical measurements with cursor-area scoping.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMultiple trigger types\u003c\/strong\u003e — edge, pulse width, video, slope, runt, over-amplitude, delay, timeout, duration, setup\/hold, Nth edge, and pattern triggers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeb remote control\u003c\/strong\u003e — browser-based access from any PC or mobile device on the LAN; no driver software, no host application.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCPI + LAN automation\u003c\/strong\u003e — Standard Command for Programmable Instruments over LAN for scripted test sequences.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eDetailed Features\u003c\/h2\u003e\n\u003ch3\u003eUltra Phosphor 2.0\u003c\/h3\u003e\n\u003cp\u003eUltra Phosphor 2.0 is UNI-T's intensity-graded display technology. Waveforms paint with 256-level brightness, where signals that recur often appear bright and rare anomalies show as faint streaks against the baseline trace — the kind of detail a flat-color display paints over.\u003c\/p\u003e\n\u003cp\u003eStandard sampling reaches 150,000 wfms\/s; engaging Fast Acquire mode pushes the rate to 500,000 wfms\/s. Combined with hardware-accelerated continuous waveform recording at up to 120,000 frames, the scope catches glitches, runt pulses, and other transient events that 8-bit value-tier oscilloscopes typically don't surface.\u003c\/p\u003e\n\u003ch3\u003eIndependent DVM Module\u003c\/h3\u003e\n\u003cp\u003eThe UPO1204 includes a built-in 4-bit digital voltmeter that operates in parallel with the scope channels, displaying AC\/DC True RMS values continuously while the oscilloscope captures waveforms. The DVM has its own display readout and a configurable warning when measurements exceed the specified range — a separate instrument's worth of capability without a separate instrument's bench space, useful for steady-state DC monitoring alongside dynamic AC measurement and for double-checking power-supply rails without breaking the trigger setup.\u003c\/p\u003e\n\u003ch3\u003e1 Mpts Enhanced FFT\u003c\/h3\u003e\n\u003cp\u003eThe 1 Mpts FFT converts time-domain waveforms to the frequency domain at resolution that matches mid-tier oscilloscopes. Frequency setting, demodulation mode, waterfall display, and automatic peak marking are all standard, supporting EMI troubleshooting, switching-supply harmonic characterization, audio-band analysis, and clock-spur identification. Five window functions (Rectangle, Hanning, Blackman, Hamming, FlatTop) cover the common analysis trade-offs between frequency resolution and amplitude accuracy.\u003c\/p\u003e\n\u003ch3\u003eStandard Bus Decoding — RS-232\/UART, I²C, SPI\u003c\/h3\u003e\n\u003cp\u003eRS-232\/UART, I²C, and SPI trigger and decode are standard — no protocol licenses, no add-on packages. Decoded bus traffic overlays the waveform with field-level annotation, and the event list view shows decoded packets alongside the time stamps. Hardware decoding running across the full 56 Mpts memory turns what would be a tens-of-seconds software decode into a sub-second operation, making the UPO1000 a usable embedded-debug instrument rather than a strictly time-domain scope.\u003c\/p\u003e\n\u003cp\u003eNo optional protocol licenses are available on the UPO1204: CAN, CAN-FD, LIN, and FlexRay are not supported on this platform. Buyers who need automotive bus decoding should look at the UPO1000HD or MSO\/UPO2000 series, which support those protocols as paid options.\u003c\/p\u003e\n\u003ch3\u003e7-digit Hardware Frequency Counter\u003c\/h3\u003e\n\u003cp\u003eA 7-digit hardware-accelerated counter runs alongside the scope's standard automated measurements. The counter reads independently from the channel measurement engine, which gives stable, high-resolution frequency readings on stable signals without the jitter that software counters can exhibit on the lower-density end of the rate range. Useful for verifying oscillator frequencies, clock-recovery loops, and PWM duty cycles where a stable frequency number matters more than time-domain detail.\u003c\/p\u003e\n\u003ch3\u003eMultiple Trigger Types\u003c\/h3\u003e\n\u003cp\u003eBeyond standard edge triggering, the scope offers pulse width, video, slope, runt, over-amplitude, delay, timeout, duration, setup\/hold, Nth edge, and pattern triggers. Runt and over-amplitude triggers isolate signal-integrity violations that an edge-only trigger would never catch; setup\/hold and Nth edge triggers isolate specific cycles in long protocol captures. The full set is standard, with no trigger-package upgrades to license.\u003c\/p\u003e\n\u003ch3\u003e36 Automated Measurements with Cursor-Area Scoping\u003c\/h3\u003e\n\u003cp\u003eThirty-six automated measurement parameters cover time, voltage, frequency, and statistical categories: rise\/fall time, pulse width, duty cycle, frequency, period, amplitude, RMS, peak-peak, mean, standard deviation, and others. Each measurement supports cursor-area scoping — the measurement runs only within the cursor window rather than across the full record — useful for measuring a specific burst within a long capture without rezooming. Statistics (min, max, mean, std-dev) accumulate over time for characterization of measurement drift.\u003c\/p\u003e\n\u003ch3\u003eWeb Remote Control and SCPI Automation\u003c\/h3\u003e\n\u003cp\u003eConnect the UPO1204 to the LAN and access the full instrument from any web browser — PC, Mac, or mobile — with no driver installation, no host application, no setup. Capture screenshots, change settings, transfer waveform data, and run SCPI commands from any device on the network. Useful for shared lab instruments, rack-mounted teaching benches with cable runs across the room, and Python or LabVIEW automation scripts that drive the scope through standard SCPI over LAN.\u003c\/p\u003e\n\u003ch3\u003eConnectivity (USB, LAN, AUX)\u003c\/h3\u003e\n\u003cp\u003eStandard interfaces include USB-Host (front and rear) for thumb-drive screenshot capture and firmware updates, USB-Device (rear) for SCPI over USB to a PC, Gigabit LAN for SCPI and web remote, and AUX output for triggered signal handoff. RS-232 is not present on this platform; SCPI runs over USB and LAN. The LAN connection supports both DHCP and static IP configuration for fixed-IP rack deployments.\u003c\/p\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003ch3\u003eTeaching Lab and Trade-School Curriculum (Education)\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMulti-station deployment at value-tier prices: a real 4 channels scope on every bench, with the same Ultra Phosphor 2.0 UI that students will see in industry on the UPO1000HD and MSO1000HD families.\u003c\/li\u003e\n\u003cli\u003e56 Mpts memory and 1 Mpts FFT cover the full spectrum-and-time-domain undergraduate curriculum without the memory-vs-sample-rate trade-offs that entry scopes normally impose.\u003c\/li\u003e\n\u003cli\u003e36 automated measurements with statistics let students focus on circuit behavior rather than measurement methodology, while the cursor-area mode supports manual measurement teaching.\u003c\/li\u003e\n\u003cli\u003eWeb-based remote control mirrors the screen for classroom demonstration without USB capture cables or projector adapters; SCPI over LAN supports Python and LabVIEW lab exercises.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEmbedded Systems Development (R\u0026amp;D)\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThree serial bus decoders standard (RS-232\/UART, I²C, SPI) cover most low-speed embedded debug workflows without protocol-license fees.\u003c\/li\u003e\n\u003cli\u003e56 Mpts memory captures full firmware-boot and protocol sequences in a single trigger, with full-memory hardware decoding for sub-second decode of long captures.\u003c\/li\u003e\n\u003cli\u003eIndependent DVM module reads supply rails alongside scope traces — useful for verifying brownout, monitoring switching ripple, or validating reference-voltage stability during prototype bring-up.\u003c\/li\u003e\n\u003cli\u003eSCPI over LAN runs Python regression scripts on the same instrument that the bench engineer uses interactively — automation without a separate automation-class scope.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectronics Service, Repair, and Maintenance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBench-portable form factor: AC-line bench scope sized for the typical service workshop without the depth or weight of a flagship instrument.\u003c\/li\u003e\n\u003cli\u003eUltra Phosphor 2.0 with 256-level intensity grading reveals signal-integrity violations (runt pulses, glitches) that flat-color displays paint over — the difference between fixing the root cause and replacing the symptom.\u003c\/li\u003e\n\u003cli\u003eHardware frequency counter gives stable rate readings for verifying oscillator and clock-recovery behavior during board-level repair.\u003c\/li\u003e\n\u003cli\u003eAC\/DC True RMS DVM module replaces the bench multimeter for steady-state checks while keeping the scope trigger configuration intact.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSwitching-Mode Power Supply Validation\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBandwidth selection from 200 MHz matches the switching frequency range of low-frequency LLC and PFC stages through high-frequency GaN\/SiC designs, with 56 Mpts memory for capturing long startup transients without losing sample rate.\u003c\/li\u003e\n\u003cli\u003e1 Mpts FFT characterizes ripple harmonics and switching-noise spectral content for EMI pre-compliance investigation alongside time-domain switching analysis.\u003c\/li\u003e\n\u003cli\u003eMultiple trigger types (runt, over-amplitude, pulse-width) isolate switching faults, current spikes during startup, and protection-circuit activations.\u003c\/li\u003e\n\u003cli\u003eIndependent DVM module monitors output-rail DC value while scope captures dynamic AC load-step behavior — both halves of the supply characterization on one instrument.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProduction Test and Quality Control\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSCPI over LAN supports rack-mounted production-line deployment with Python or LabVIEW test scripts; the web remote interface gives line operators a familiar browser-based view without driver installation on each test station.\u003c\/li\u003e\n\u003cli\u003e36 automated measurements with statistics support go\/no-go testing of board-level signal-integrity specs; the cursor-area mode isolates specific cycles for measurement without re-zooming the full capture.\u003c\/li\u003e\n\u003cli\u003eContinuous waveform recording into the memory depth supports historical archiving of production-line captures for later analysis when a batch shows yield-tail issues.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEMI Pre-Compliance Investigation\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 Mpts FFT with five window functions, demodulation mode, and waterfall display supports time-correlated EMI investigation against the time-domain switching waveform — useful for tracking down which switching event produces which emission peak.\u003c\/li\u003e\n\u003cli\u003eMarker measurement on the FFT supports quick peak frequency and amplitude readout during emission-hunt work on a prototype board.\u003c\/li\u003e\n\u003cli\u003eCombined with a near-field probe set and a Faraday-cage cardboard tent, the FFT view supports pre-compliance investigation that catches the obvious failures before the expensive compliance-lab booking.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBandwidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChannels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReal-Time Sample Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 GSa\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSample Rate per Channel Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 GSa\/s on a single channel; 1 GSa\/s on two; 500 MSa\/s on all four\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCalculated Rise Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ 1.8 ns\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMemory Depth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e56 Mpts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVertical Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 bits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVertical Scale (1 MΩ)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 µV\/div to 20 V\/div\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Input Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400 V (DC + AC Vpk)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWaveform Capture Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500,000 wfms\/s (Fast Acquire mode); 150,000 wfms\/s normal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContinuous Frame Recording\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120,000 frames\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFFT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 Mpts enhanced FFT (5 window functions)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDVM\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIndependent module — 4-bit, AC\/DC True RMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency Counter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7-digit hardware\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAutomated Measurements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e36 parameters with statistics and cursor-area scoping\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrigger Types\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEdge, Pulse Width, Video, Slope, Runt, Over-Amplitude, Delay, Timeout, Duration, Setup\/Hold, Nth Edge, Pattern\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSerial Bus Decoding (Standard)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRS-232\/UART, I²C, SPI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOptional Protocol Decoders\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNone available on this platform\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7-inch WVGA TFT LCD, 256-level intensity grading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSB-Host (front + rear), USB-Device (rear), LAN (1 GbE), AUX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRemote Control\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWeb browser (no driver), SCPI over LAN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCE | cETLus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0°C to 40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLine Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100–240 VAC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e75 VA maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.45 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e306 × 138 × 107 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eDownloads\u003c\/h4\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cbr\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cstrong\u003e\u003ca rel=\"noopener\" title=\"UPO1000 Series Datasheet\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/UPO1000_Datasheet.pdf\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/pdf-icon-63x63_480x480.png\" style=\"float: left;\" alt=\"PDF\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/850009-i.pdf\" target=\"_blank\"\u003e\u003cbr\u003e\u003c\/a\u003e\u003ca rel=\"noopener\" title=\"UNI-T UPO1000 Series Datasheet\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/UPO1000_Datasheet.pdf\" target=\"_blank\"\u003eUNI-T UPO1000 Series Datasheet\u003c\/a\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cbr\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/UPO1000_-_User_Manual_-_V1.0.pdf\" title=\"UNI-T UPO1000 Series Users Manual\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/pdf-icon-63x63_480x480.png\" style=\"float: left;\" alt=\"PDF\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/850009-i.pdf\" target=\"_blank\"\u003e\u003cbr\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/UPO1000_-_User_Manual_-_V1.0.pdf\" title=\"UNI-T UPO1000 Series Users Manual\" rel=\"noopener\" target=\"_blank\"\u003eUNI-T UPO1000 Series Users Manual\u003c\/a\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003e\u003c\/h4\u003e\n\u003ch4\u003eAccessories \u0026amp; Options\u003c\/h4\u003e\n\u003ch3\u003eIncluded\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUPO1204 digital storage oscilloscope\u003c\/li\u003e\n\u003cli\u003ePower cord (national standard)\u003c\/li\u003e\n\u003cli\u003eUSB 2.0 data cable\u003c\/li\u003e\n\u003cli\u003e4 × passive probes — UT-P07A (500 MHz, one per channel)\u003c\/li\u003e\n\u003cli\u003eQuick start guide\u003c\/li\u003e\n\u003cli\u003eFactory calibration certificate\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eRecommended Accessories\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-voltage passive probes\u003c\/strong\u003e — UT-P20 (100:1, 250 MHz), UT-V23 (100:1), UT-P21 (1000:1, DC 10 kV \/ AC 7 kVrms) for line-voltage and HV switching work.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDifferential probes\u003c\/strong\u003e — UT-P30, UT-P31, UT-P32, UT-P33, UT-P35, UT-P36 for floating measurements where ground reference can't be tied to scope chassis.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent probes\u003c\/strong\u003e — UT-P40, UT-P41, UT-P42, UT-P43, UT-P44; UT-P4150 for high-current AC\/DC measurement on switching and motor-drive applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation transformer\u003c\/strong\u003e — UT-ISOT for line-powered DUTs that require galvanic isolation between scope ground and DUT ground.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFamily Members\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUPO1054 — 50 MHz, 4 channels, 2 GSa\/s\u003c\/li\u003e\n\u003cli\u003eUPO1104 — 100 MHz, 4 channels, 2 GSa\/s\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUPO1204\u003c\/strong\u003e — 200 MHz, 4 channels, 2 GSa\/s \u003cem\u003e(this product)\u003c\/em\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eStep Up: UPO1000HD (4-channel, 12-Bit Vertical)\u003c\/h3\u003e\n\u003cp\u003eIf your application needs higher vertical resolution or deeper memory than the UPO1204 provides, the UPO1000HD family offers 12-bit vertical resolution and the same Ultra Phosphor 2.0 display engine in the same cabinet footprint.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUPO1084HD — 80 MHz, 4 channels, 12-bit vertical resolution\u003c\/li\u003e\n\u003cli\u003eUPO1154HD — 150 MHz, 4 channels, 12-bit vertical resolution\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch4\u003eFAQ's\u003c\/h4\u003e\n\u003ch3\u003eWhich serial bus protocols are decoded as standard, and which require a license?\u003c\/h3\u003e\n\u003cp\u003eThe UPO1204 decodes \u003cstrong\u003eRS-232\/UART, I²C, and SPI\u003c\/strong\u003e as standard — trigger and decode functions for all three are included with the scope, with no license fees and no protocol-option purchase required. \u003cstrong\u003eNo optional protocol decoders are available on this platform.\u003c\/strong\u003e CAN, CAN-FD, LIN, and FlexRay are not supported on the UPO1000 platform. If your application requires automotive bus decoding, the UPO1000HD or MSO\/UPO2000 series support those protocols as paid options.\u003c\/p\u003e\n\u003ch3\u003eWhat is Fast Acquire mode, and when should I use it?\u003c\/h3\u003e\n\u003cp\u003eFast Acquire is a UPO1000-series acquisition mode that boosts waveform capture rate from 150,000 wfms\/s (standard) to \u003cstrong\u003e500,000 wfms\/s\u003c\/strong\u003e. The trade-off is that some screen-update detail is sacrificed for raw capture throughput. Use Fast Acquire when hunting intermittent signal-integrity events (glitches, runt pulses, rare protocol violations) that depend on capturing many waveforms quickly. Use standard mode for everyday time-domain measurement work where the display refresh rate matters more than raw capture density.\u003c\/p\u003e\n\u003ch3\u003eDoes the DVM module share input channels with the scope, or is it truly independent?\u003c\/h3\u003e\n\u003cp\u003eThe DVM is \u003cstrong\u003etruly independent\u003c\/strong\u003e: it has its own 4-bit measurement input and operates in parallel with the four (or two) scope channels. You can run a continuous AC\/DC True RMS reading on a supply rail while the scope captures dynamic switching behavior on another channel, without any time-sharing between the two functions. The DVM readout appears on a dedicated portion of the screen and persists across scope-channel configuration changes.\u003c\/p\u003e\n\u003ch3\u003eWhat does the web remote control look like in practice, and how does SCPI automation work?\u003c\/h3\u003e\n\u003cp\u003eConnect the UPO1204 to your LAN, point any browser at the scope's IP, and you get a full-screen replica of the front panel that you can drive from your desk or a mobile device — no driver installation, no host application. Useful for shared lab instruments and projection during teaching demos. For automation, the scope responds to \u003cstrong\u003eSCPI commands over LAN\u003c\/strong\u003e (Standard Commands for Programmable Instruments), which means Python (pyvisa), MATLAB Instrument Control Toolbox, LabVIEW, and any other VISA-aware tool can drive the scope through scripts. SCPI also runs over USB-Device for PC-tethered automation when LAN isn't available.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Uni-Trend US","offers":[{"title":"Default Title","offer_id":53265475797216,"sku":"181100200075X","price":553.6,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/UPO1204_1_sq.jpg?v=1782858082"},{"product_id":"ut-p35-50-mhz-50-1-500-1-differential-oscilloscope-probe","title":"UT-P35 50 MHz 50:1\/500:1 Differential Oscilloscope Probe","description":"\u003ch1\u003e50 MHz differential oscilloscope probe (50:1\/500:1 attenuation) for safely measuring floating voltages across motor drives, power converters, and bridge circuits.\u003c\/h1\u003e\n\u003cp\u003e\u003cstrong\u003e Compatible with UNI-T oscilloscopes and most oscilloscopes with BNC inputs.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e50MHz Bandwidth\u003c\/strong\u003e — Captures signal content up to 50MHz for accurate waveform measurement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e50:1\/500:1 Attenuation\u003c\/strong\u003e — Attenuation ratio suited to the probe measurement range.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e130VDC+Peak AC \/ 1300VDC+Peak AC, Accuracy: 2% Maximum Input Voltage\u003c\/strong\u003e — Rated input voltage for safe operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard BNC Connection\u003c\/strong\u003e — Compatible with UNI-T oscilloscopes and most oscilloscopes with BNC inputs.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCAT Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCAT I 1000 V \/ CAT II 600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e160 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-10 °C - 45 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBandwidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe Attenuation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50:1, 500:1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe Max Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1300Vpp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRise Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7ns\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60cm input \/ 90cm output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Capacitance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.5 pF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 °C - 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNoise\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ 1.5mVrms (1\/50); ≤ 1mVrms (1\/500)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDifferential Input Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1300Vpp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommon Mode Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1000Vrms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCMRR\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≥ 80 dB DC, ≥ 60 dB 100 Hz, ≥ 50 dB 1 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Uni-Trend US","offers":[{"title":"Default Title","offer_id":53265475829984,"sku":"190500100119X","price":395.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/UT-P35_1_sq.jpg?v=1782858082"},{"product_id":"ut-p33-120-mhz-10-1-100-1-differential-oscilloscope-probe","title":"UT-P33 120 MHz 10:1\/100:1 Differential Oscilloscope Probe","description":"\u003ch1\u003e120 MHz differential oscilloscope probe (10:1\/100:1 attenuation) for safely measuring floating voltages across motor drives, power converters and bridge circuits.\u003c\/h1\u003e\n\u003cp\u003e\u003cstrong\u003eCompatible with UNI-T oscilloscopes and most oscilloscopes with BNC inputs.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e120MHz Bandwidth\u003c\/strong\u003e — Captures signal content up to 120MHz for accurate waveform measurement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e10:1\/100:1 Attenuation\u003c\/strong\u003e — Divides the input signal for measuring higher-voltage circuits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e14kVpp Maximum Input Voltage\u003c\/strong\u003e — Rated input voltage for safe operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard BNC Connection\u003c\/strong\u003e — Compatible with UNI-T oscilloscopes and most oscilloscopes with BNC inputs.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCAT Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCAT III\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e69 × 26 × 165 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBandwidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe Attenuation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100:1, 1000:1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe Max Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14kVpp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRise Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3ns\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Capacitance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 pF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Impedance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 MΩ \/ 1 pF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 °C - 50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDifferential Input Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14kVpp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommon Mode Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5kVrms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCMRR\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 80 dB @ 60 Hz, \u0026gt; 60 dB @ 100 Hz, \u0026gt; 50 dB @ 1 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Uni-Trend US","offers":[{"title":"Default Title","offer_id":53265475862752,"sku":"190500300028X","price":1465.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/UT-P33_1_sq.jpg?v=1782858082"},{"product_id":"ut-m13x-oscilloscope-demo-board","title":"UT-M13X Oscilloscope Demo Board","description":"\u003ch1\u003eThe demo board is a tool for demonstrating the basic functions of an oscilloscope. It is powered by a USB port and can output 40 types of signals.\u003c\/h1\u003e\n\u003ch3\u003eFor use with UNI-T oscilloscopes.\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFor use with UNI-T oscilloscopes\u003c\/strong\u003e — Demonstrates basic oscilloscope functions including waveform display, triggering, and measurement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTraining and Demonstration\u003c\/strong\u003e — Provides standard test signals for learning oscilloscope operation, triggering, and measurement functions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePortable Design\u003c\/strong\u003e — Compact board that connects directly to oscilloscope inputs for benchtop or classroom use.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Uni-Trend US","offers":[{"title":"Default Title","offer_id":53265475895520,"sku":"191000100025X","price":209.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/UT-M13X_sq.jpg?v=1782858082"},{"product_id":"mso3034x-350-mhz-4ch-mixed-signal-oscilloscope","title":"MSO3034X 350 MHz 4Ch Mixed Signal Oscilloscope","description":"\u003ch1\u003eThe MSO3034X is a 350 MHz, four-channel mixed-signal oscilloscope.\u003c\/h1\u003e\n\u003cp\u003eWith 5 GSa\/s real-time sample rate, 500 Mpts of acquisition memory, 16 logic-analyzer channels (with the optional UT-M15 probe pod), and Ultra Phosphor 3.0 waveform mapping at up to 2,000,000 wfms\/s in Sequential Mode, the MSO3034X consolidates nine bench instruments into one 10.1-inch capacitive multi-touch footprint — oscilloscope, logic analyzer, AWG, spectrum analyzer, DVM, frequency counter, protocol analyzer, Bode plot, and power analyzer.\u003c\/p\u003e\n\u003cp\u003eFor 350 MHz mixed-signal R\u0026amp;D validation, four-channel power-electronics characterization, and engineering-team benches that need protocol decode, spectrum, AWG, and power analysis alongside scope acquisition, the MSO3034X is the entry SKU into UNI-T’s MSO3000X line at the most accessible price point. The 500 Mpts memory holds long acquisition windows for protocol-event hunting and switching-supply transient capture without sacrificing sample rate, and the 12-protocol decode set includes computer, automotive, audio, and aerospace bus families that mid-tier scopes commonly leave on the option list.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e350 MHz Bandwidth, 4 Analog Channels\u003c\/strong\u003e — Four-channel acquisition at up to 350 MHz with 5 GSa\/s sample rate (interleave) and calculated rise time of ≤1.0 ns — fast enough to capture rise-time and overshoot detail on faster MCU and FPGA reference designs, switching-converter gate drives, and mid-bandwidth analog signal-integrity work.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e500 Mpts Memory Depth\u003c\/strong\u003e — Standard deep memory across all four channels for long capture windows without sample-rate trade.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUltra Phosphor 3.0 Display Technology\u003c\/strong\u003e — 256-level grayscale persistence with parallel FPGA mapping; up to 800,000 wfms\/s standard, 2,000,000 wfms\/s in Sequential Mode.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNine Instruments in One\u003c\/strong\u003e — Oscilloscope, 16-channel logic analyzer (optional probe), AWG (optional), 1.25 GHz spectrum analyzer, 4-digit DVM, 7-digit hardware frequency counter, protocol analyzer, Bode plot (with AWG), and six-measurement power analyzer (optional).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard Protocol Decoding\u003c\/strong\u003e — RS-232\/422\/485\/UART, I²C, and SPI included as standard.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptional Protocol Decoding\u003c\/strong\u003e — CAN, CAN-FD, LIN, FlexRay, SENT, Audio (I²S\/LJ\/RJ\/TDM), MIL-STD-1553B, ARINC 429, and Manchester — 12 protocols total across computer, automotive, audio, aerospace, and wireless domains.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e16 Digital Channels (Optional)\u003c\/strong\u003e — Add mixed-signal capability with the UT-M15 logic probe pod; 1.25 GSa\/s digital sample rate, 800 ps minimum detectable pulse width.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptional 50 MHz Dual-Channel AWG with Bode Plot\u003c\/strong\u003e — 16-bit, 250 MSa\/s arbitrary waveform generator with the Bode plot analyzer included for closed-loop frequency-response analysis.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eZone Triggering\u003c\/strong\u003e — Rectangle-drawn trigger conditions with Must Intersect \/ Must Not Intersect logic, plus eleven additional trigger types.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e54 Automated Measurements\u003c\/strong\u003e — Voltage, time, frequency, and statistical measurements with histogram and trend statistics; up to 27 displayed simultaneously.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e10.1-Inch Capacitive Multi-Touch\u003c\/strong\u003e — 1280×800 HD display with multi-window layout, gesture control, and HDMI output.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCPI and WebServer Remote Control\u003c\/strong\u003e — USB 3.0, LAN (VXI-11), and built-in browser-based control from PC or mobile.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFree Firmware Updates and No-Expiration License Unlocks\u003c\/strong\u003e — Firmware updates are free over the product’s lifetime; license unlocks for optional packages have no expiration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eDetailed Features\u003c\/h2\u003e\n\u003ch3\u003eNine Instruments in One\u003c\/h3\u003e\n\u003cp\u003eThe MSO3000X integrates nine instrument functions into one bench unit: digital storage oscilloscope, 16-channel logic analyzer (with the optional UT-M15 probe pod), 50 MHz dual-channel function and arbitrary waveform generator (optional), 1.25 GHz spectrum analyzer (FFT up to 4 Mpts), 4-digit DVM, 7-digit hardware frequency counter, multi-protocol serial-bus analyzer covering 12 bus types, Bode plot analyzer (optional, paired with the AWG for closed-loop sweep), and a six-measurement power-electronics analyzer (optional). For mid-tier R\u0026amp;D benches consolidating across protocol decode, spectrum analysis, AWG-driven stimulus, and four-channel scope work in the same session, the integration eliminates the cable-swap-and-instrument-handoff cycle that breaks engineering flow on multi-instrument bench setups, and the optional power-analysis package adds a working power-electronics analyzer alongside the existing acquisition path.\u003c\/p\u003e\n\u003ch3\u003eHigh-Speed Acquisition — 5 GSa\/s, 500 Mpts\u003c\/h3\u003e\n\u003cp\u003eThe 5 GSa\/s real-time sample rate (interleave) and 500 Mpts of acquisition memory hold full waveform fidelity across the 350 MHz analog bandwidth. Standard capture rate runs up to 800,000 wfms\/s; in Sequential Mode — the segmented-memory mode that conditions captures on a trigger event — capture rate climbs to 2,000,000 wfms\/s, recording up to 200,000 frames for post-capture replay and analysis.\u003c\/p\u003e\n\u003ch3\u003eDeep Memory — 500 Mpts Per Acquisition\u003c\/h3\u003e\n\u003cp\u003eThe 500 Mpts memory depth holds long acquisition windows at full sample rate — the difference between catching an intermittent fault on a 100 ms capture and missing it because the memory was saturated at 5 ms. For protocol-event hunting on high-traffic CAN-FD or FlexRay buses, switching-supply transient analysis across multiple cycles, and long-term jitter characterization, the deep-memory budget removes the sample-rate vs. window-length trade-off that limits mid-tier 100 Mpts scopes.\u003c\/p\u003e\n\u003ch3\u003eVertical Resolution — 8-Bit Native with ERES to 12-Bit\u003c\/h3\u003e\n\u003cp\u003eThe MSO3034X uses an 8-bit native ADC with up to 12-bit effective resolution via ERES (enhanced resolution) when bandwidth headroom is available — useful for low-amplitude signal work where quantization noise would obscure detail on switching ripple, sensor outputs, or jitter analysis. For wider-bandwidth designs requiring native 12-bit resolution at full bandwidth, see UNI-T’s MSO3000HD-series scopes, which use the R12™ native 12-bit ADC architecture at the same 200–500 MHz bandwidth tier.\u003c\/p\u003e\n\u003ch3\u003eUltra Phosphor 3.0 — 256-Level Grayscale Persistence\u003c\/h3\u003e\n\u003cp\u003eUltra Phosphor 3.0 is UNI-T’s third-generation waveform-mapping architecture: parallel FPGA acquisition with 256-level grayscale intensity grading, a 20 Gbps internal data path, and sub-1 µs dead time. The scope captures fast-edge signals at 2,000,000 events per second in Sequential Mode without missing the rare-event bracket between redraws. Intensity grading shows frequency-of-occurrence directly — frequent waveforms appear brighter, infrequent ones dimmer — making intermittent faults easy to distinguish from normal behavior.\u003c\/p\u003e\n\u003ch3\u003eBuilt-In Spectrum Analyzer — FFT to 4 Mpts\u003c\/h3\u003e\n\u003cp\u003eThe standard enhanced-FFT spectrum analyzer covers 0 Hz to 1.25 GHz with up to 4 Mpts FFT length, four-channel analysis, four trace types (Normal, Average, Max Hold, Min Hold), and four detection modes. Markers plus a waterfall display track spectral activity over time — for harmonic ID, EMI pre-compliance sweeps, clock-purity verification, and modulated-signal analysis without the cable swap a separate spectrum analyzer requires.\u003c\/p\u003e\n\u003ch3\u003eProtocol Analysis — 12 Bus Types Across Five Domains\u003c\/h3\u003e\n\u003cp\u003eTwelve protocols across five bus domains: computer serial (RS-232\/422\/485\/UART, I²C, SPI — standard); automotive (CAN, CAN-FD, LIN, FlexRay, SENT — optional); audio (I²S, LJ, RJ, TDM — optional); aerospace (MIL-STD-1553B, ARINC 429 — optional); and Manchester wireless (optional). Triggering and decoding are integrated — trigger on a frame error, identifier match, CRC failure, or missing-ack condition, and the decode displays inline with the captured waveform. The aerospace and Manchester decode set differentiates this protocol envelope from mid-tier scopes that stop at automotive and audio.\u003c\/p\u003e\n\u003ch3\u003e50 MHz Dual-Channel AWG with Bode Plot (Optional)\u003c\/h3\u003e\n\u003cp\u003eThe optional MSO3000X-AWG package adds a 50 MHz dual-channel function\/arbitrary waveform generator (16-bit, 250 MSa\/s) plus the Bode plot analyzer for frequency-response, loop-stability, filter, and amplifier characterization. Built-in waveforms include sine, square, pulse, ramp, arbitrary, noise, and DC, with AM, FM, ASK, FSK, and sweep modulation. On-screen captures load directly into the AWG for stimulus-response replay.\u003c\/p\u003e\n\u003ch3\u003ePower Analysis (Optional) — Six Measurement Types\u003c\/h3\u003e\n\u003cp\u003eFor switching-mode power-supply validation, motor-drive characterization, and DC-DC converter design at moderate switching frequencies, the optional power-analysis package adds a six-measurement suite (power quality, harmonic analysis, switching loss, ripple analysis, loop analysis, safe operating area) to the four-channel acquisition path. The same scope that captures the gate-drive waveform also computes switching loss across the cycle, replaces a separate power analyzer for early-stage characterization, and pairs with the Bode plot analyzer (included with the optional AWG) for closed-loop stability sweeps on switching converters.\u003c\/p\u003e\n\u003ch3\u003eZone Triggering — Rectangle-Drawn Trigger Conditions\u003c\/h3\u003e\n\u003cp\u003eZone triggering isolates an occasional anomaly by trigger condition rather than waveform stability. Draw a rectangle on the display, set Must Intersect or Must Not Intersect, and the scope triggers when the waveform meets the spatial condition. With eleven additional trigger types (edge, pulse width, ramp, runt, over-amplitude, delay, timeout, duration, setup \u0026amp; hold, Nth edge, code pattern), zone triggering turns rare-event hunting into a defined acquisition.\u003c\/p\u003e\n\u003ch3\u003e54 Automated Measurements with Histogram and Trend Statistics\u003c\/h3\u003e\n\u003cp\u003e54 automated measurement parameters on the analog channels — voltage, time, frequency, statistical, and burst measurements — with up to 27 displayed simultaneously. Statistics include mean, max, min, standard deviation, count, tendency chart, and histogram. The burst function reports values across burst segments — useful for jitter analysis, long-capture characterization, and pass\/fail evidence reports.\u003c\/p\u003e\n\u003ch3\u003eFast Fuzzy Autoset\u003c\/h3\u003e\n\u003cp\u003eThe fuzzy-logic autoset algorithm uses the 7-digit hardware frequency counter and multi-channel parallel processing to lock onto unknown signals quickly: all-channel autoset in under 1.5 seconds, single-channel under 1 second — meaningful on production-line spot-check work and engineering benches that swap test articles often.\u003c\/p\u003e\n\u003ch3\u003e10.1-Inch Capacitive Multi-Touch UI\u003c\/h3\u003e\n\u003cp\u003eThe 10.1-inch 1280×800 HD capacitive multi-touch display supports standard touch gestures (click, slide, zoom, edit, drag) for direct waveform manipulation, plus rectangle-draw for zone triggering. Multi-window layout lets waveform, FFT, decode-list, and measurement-table panels be dragged and resized independently. Knob-and-key controls remain; HDMI output mirrors the display to an external monitor or projector.\u003c\/p\u003e\n\u003ch3\u003eConnectivity, SCPI, and WebServer Remote Control\u003c\/h3\u003e\n\u003cp\u003eUSB 3.0 Host (one front, two rear), USB 3.0 Device, LAN (10\/100\/1000 BASE-T, VXI-11), HDMI display output, two front-panel Gen Out connectors (paired with the optional AWG), 10 MHz reference In\/Out, and AUX Out (Trig Out \/ Pass-Fail \/ DVM). Full SCPI command set; the built-in WebServer provides browser-based remote control from PC or mobile without driver installation.\u003c\/p\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003ch3\u003eFor R\u0026amp;D Engineers\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFor mainstream R\u0026amp;D validation at 350 MHz, the MSO3034X covers ARM Cortex-A microcontroller debug, mid-speed FPGA reference designs, four-channel time-correlated mixed-signal work (with the UT-M15 logic probe pod), and 12-protocol decode across computer, automotive, audio, and aerospace buses — covering a broad envelope of design-validation work in one instrument.\u003c\/li\u003e\n\u003cli\u003eTime-correlated mixed-signal capture across analog channels and 16 digital lines (with the UT-M15 probe pod) on the same instrument and the same trigger event.\u003c\/li\u003e\n\u003cli\u003e12-protocol decode set covering computer, automotive, audio, aerospace, and Manchester-wireless buses; up to four simultaneous decodes plus event list and search.\u003c\/li\u003e\n\u003cli\u003eZone triggering for rare-event hunting on intermittent timing anomalies, runts, and glitches; eleven trigger types cover the full embedded-systems debug envelope.\u003c\/li\u003e\n\u003cli\u003e500 Mpts memory captures long acquisition windows for protocol-event hunting and post-event analysis; Sequential Mode records up to 200,000 frames of triggered events.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFor Power Electronics Engineers\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFor switching-mode power-supply validation and DC-DC converter characterization at moderate switching frequencies, the MSO3034X pairs four-channel acquisition with the optional six-measurement power-analysis suite, the optional 50 MHz AWG with Bode plot analyzer for closed-loop stability sweeps, and 500 Mpts memory for multi-cycle transient capture — covering the full converter-design workflow on one instrument.\u003c\/li\u003e\n\u003cli\u003eOptional six-measurement power-analysis package: power quality, harmonic analysis, switching loss, ripple analysis, loop analysis, and safe operating area visualization.\u003c\/li\u003e\n\u003cli\u003eFour-channel acquisition supports vIN \/ vOUT \/ IL \/ vGS measurement on switching converters and DC-DC supplies in a single time-correlated capture.\u003c\/li\u003e\n\u003cli\u003eOptional dual-channel 50 MHz AWG with Bode plot analyzer for closed-loop frequency-response and stability sweeps on power-supply controllers.\u003c\/li\u003e\n\u003cli\u003eSequential Mode captures 200,000 frames of triggered events for fault-recovery and burst-mode analysis on intermittent power events and load-step transients.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFor Education and Teaching Labs\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFor undergraduate and graduate-track engineering labs running advanced embedded-systems, signals-and-systems, and power-electronics-introduction coursework, the MSO3034X delivers 350 MHz of analog bandwidth alongside the integrated nine-instrument suite and 12-protocol decode — covering scope, FFT spectrum, protocol decode, AWG-driven stimulus, and power-electronics fundamentals in one teaching-bench footprint, with HDMI projection for instructor-led demonstrations.\u003c\/li\u003e\n\u003cli\u003eNine integrated instruments cover most of the bench-instrument curriculum on one operator-training surface, from analog-and-digital fundamentals through introductory power-electronics topics.\u003c\/li\u003e\n\u003cli\u003eHDMI output mirrors the display to a projector or external monitor for instructor-led demonstrations.\u003c\/li\u003e\n\u003cli\u003eWebServer remote access lets students view captures and run measurements from networked classroom devices without crowding the bench.\u003c\/li\u003e\n\u003cli\u003e10.1-inch capacitive multi-touch UI plus traditional knob-and-key controls support a range of student comfort levels with bench-instrument operation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO3034X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAnalog Bandwidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e350 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCalculated Rise Time (10% to 90%, typical)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤1.0 ns\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAnalog Channels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 (plus 1 external trigger channel)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDigital Channels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 (with optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Real-Time Sample Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 GSa\/s (interleave) \/ 2.5 GSa\/s (non-interleave)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Digital Sample Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.25 GSa\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Memory Depth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 Mpts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVertical Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8-bit native; up to 12-bit via ERES\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandard Capture Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800,000 wfms\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSequential Mode Capture Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2,000,000 wfms\/s (up to 200,000 frames recorded)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrigger Types\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEdge, pulse width, ramp, runt pulse, over-amplitude pulse, delay, timeout, duration, setup \u0026amp; hold, Nth edge, code pattern, video, zone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtocol Decoding (Standard)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRS-232\/422\/485\/UART, I²C, SPI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtocol Decoding (Optional)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCAN, CAN-FD, LIN, FlexRay, SENT, Audio (I²S\/LJ\/RJ\/TDM), MIL-STD-1553B, ARINC 429, Manchester\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSpectrum Analyzer (FFT)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 Hz to 1.25 GHz, up to 4 Mpts FFT, 4 traces, 4 detections, waterfall\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAWG (Optional MSO3000X-AWG)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 MHz, 2 channels, 16-bit, 250 MSa\/s; includes Bode plot analyzer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Analysis (Optional MSO3000X-PWR)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower quality, harmonic analysis, switching loss, ripple analysis, loop analysis, safe operating area\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAutomated Measurements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e54 (analog channels); up to 27 displayed simultaneously\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10.1-inch 1280×800 capacitive multi-touch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterfaces\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSB 3.0 Host (3) \/ USB 3.0 Device (1) \/ LAN (VXI-11) \/ HDMI \/ Gen Out (2) \/ 10 MHz In\/Out \/ AUX Out\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRemote Control\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSCPI; built-in WebServer (PC and mobile)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCE, cETLus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eAccessories \u0026amp; Options\u003c\/h4\u003e\n\u003ch3\u003eIncluded\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUT-P07A (500 MHz, 10:1) × 4 [supports 350 MHz scope BW] passive probes (one per channel)\u003c\/li\u003e\n\u003cli\u003eUT-D30 USB 3.0 cable\u003c\/li\u003e\n\u003cli\u003eUT-L45 BNC-to-BNC direct-through cable\u003c\/li\u003e\n\u003cli\u003eUT-L02A BNC red and black alligator connecting wire\u003c\/li\u003e\n\u003cli\u003eNational-standard power cable\u003c\/li\u003e\n\u003cli\u003eQuick start guide\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAvailable Options\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMSO3000X-AWG — Dual-channel 50 MHz AWG with Bode plot analyzer\u003c\/li\u003e\n\u003cli\u003eMSO3000X-PWR — Power analysis package (6 measurement types)\u003c\/li\u003e\n\u003cli\u003eMSO3000X-BND — Full serial-bus triggering and decoding bundle (AUTO + AUDIO + MIL-STD + ARINC429 + MANCH)\u003c\/li\u003e\n\u003cli\u003eMSO3000X-AUTO — Automotive serial bus bundle (CAN, CAN-FD, LIN, FlexRay, SENT)\u003c\/li\u003e\n\u003cli\u003eIndividual protocol licenses: CAN, CAN-FD, LIN, FlexRay, SENT, AUDIO, MIL1553, ARINC429, MANCH\u003c\/li\u003e\n\u003cli\u003eMSO3000X-BW3M5T5M — 350 MHz to 500 MHz bandwidth upgrade\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eRecommended Accessories\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUT-M15 — 16-channel logic probe pod\u003c\/li\u003e\n\u003cli\u003eUT-PA2000 — 2 GHz active probe (auto-sense attenuation, ±8 V offset range)\u003c\/li\u003e\n\u003cli\u003eUT-P07A — 500 MHz high-resistance passive probe\u003c\/li\u003e\n\u003cli\u003eUT-P20 \/ UT-P21 — High-voltage probes\u003c\/li\u003e\n\u003cli\u003eUT-P30 \/ UT-P31 \/ UT-P32 \/ UT-P33 — High-voltage differential probes\u003c\/li\u003e\n\u003cli\u003eUT-P40 \/ UT-P41 \/ UT-P42 \/ UT-P43 \/ UT-P44 — Current probes\u003c\/li\u003e\n\u003cli\u003eUT-ISOT — Isolation transformer\u003c\/li\u003e\n\u003cli\u003eUT-M13X — Oscilloscope demo board\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSoftware Options\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMSO3000X-ARINC429 — Aerospace ARINC429 Serial Bus Trigger and Analysis\u003c\/li\u003e\n\u003cli\u003eMSO3000X-AUDIO — Serial Bus Trigger and Analysis Option (I2S, LJ, RJ, TDM)\u003c\/li\u003e\n\u003cli\u003eMSO3000X-AUTO — Serial Bus Trigger and Decode Bundle (CAN, CAN-FD, LIN, FlexRay, SENT)\u003c\/li\u003e\n\u003cli\u003eMSO3000X-AWG — Arbitrary Waveform Generator option\u003c\/li\u003e\n\u003cli\u003eMSO3000X-BND — Serial Bus Trigger and Decode Bundle (incl. AUTO, AUDIO, MIL-STD, ARINC429, MANCH)\u003c\/li\u003e\n\u003cli\u003eMSO3000X-CAN — Automotive CAN Serial Bus Trigger and Analysis\u003c\/li\u003e\n\u003cli\u003eMSO3000X-CANFD — Automotive CAN-FD Serial Bus Trigger and Analysis\u003c\/li\u003e\n\u003cli\u003eMSO3000X-FLEX — Automotive FlexRay Serial Bus Trigger and Analysis\u003c\/li\u003e\n\u003cli\u003eMSO3000X-LIN — Automotive LIN Serial Bus Trigger and Analysis\u003c\/li\u003e\n\u003cli\u003eMSO3000X-MANCH — Manchester Serial Bus Trigger and Analysis Option\u003c\/li\u003e\n\u003cli\u003eMSO3000X-MIL1553 — MIL-STD-1553 Serial Bus Trigger and Analysis Option\u003c\/li\u003e\n\u003cli\u003eMSO3000X-PWR — Power Analysis Option\u003c\/li\u003e\n\u003cli\u003eMSO3000X-SENT — Automotive SENT Sensor Bus Trigger and Analysis\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFamily Members and Related Scopes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMSO3054X (500 MHz, 4-channel)\u003c\/li\u003e\n\u003cli\u003eMSO2304X (300 MHz, MSO2000X line)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch4\u003eFAQ's\u003c\/h4\u003e\n\u003ch3\u003eWhat’s the difference between standard capture rate and Sequential Mode capture rate?\u003c\/h3\u003e\n\u003cp\u003eStandard capture rate (800,000 wfms\/s) is the rate at which the MSO3034X acquires waveforms during continuous real-time operation. Sequential Mode (2,000,000 wfms\/s) uses segmented memory to condition captures on a trigger event, holding up to 200,000 frames of triggered acquisitions for post-capture replay. Use standard mode for general waveform observation; use Sequential Mode for rare-event hunting where the trigger condition is well-defined.\u003c\/p\u003e\n\u003ch3\u003eShould I size up to the MSO3054X instead?\u003c\/h3\u003e\n\u003cp\u003eIf your fastest signal edges are below ~300 MHz and you don’t need deeper visibility into 500 MHz analog content, the MSO3034X has the same 5 GSa\/s, 500 Mpts platform, the same 12-protocol decode set, and the same Ultra Phosphor 3.0 waveform-mapping engine as the MSO3054X — the 350 MHz bandwidth is the only meaningful difference on the spec sheet. The MSO3054X is worth the step-up when you’re working at the rise-time edge of 500 MHz analog signal-integrity, characterizing higher-bandwidth switching converters, or running closed-loop stability sweeps on wide-bandgap (GaN\/SiC) power converters where the additional headroom shows up in measurement accuracy.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cp class=\"product-tagline\"\u003e \u003c\/p\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Uni-Trend US","offers":[{"title":"181100300068X","offer_id":53265475961056,"sku":"181100300068X","price":2159.2,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/MSO3000X_1_sq.jpg?v=1782858083"},{"product_id":"mso2304x-300-mhz-4ch-mixed-signal-oscilloscope","title":"MSO2304X 300 MHz 4Ch Mixed Signal Oscilloscope","description":"\u003ch1\u003eThe MSO2304X is a 300 MHz, four-channel mixed-signal oscilloscope.\u003c\/h1\u003e\n\u003cp\u003eWith 5 GSa\/s real-time sample rate, 100 Mpts of memory depth, 16 logic-analyzer channels (with the optional UT-M15 probe pod), and Ultra Phosphor 3.0 waveform mapping at up to 2,000,000 wfms\/s in Sequential Mode, the MSO2304X integrates nine bench instruments into one 10.1-inch capacitive multi-touch footprint — oscilloscope, logic analyzer, AWG, spectrum analyzer, DVM, frequency counter, protocol analyzer, Bode plot, and power analyzer.\u003c\/p\u003e\n\u003cp\u003eFor four-channel power-electronics validation, switching-converter characterization, and high-bandwidth mixed-signal debug at the top of the MSO2000X line, the MSO2304X delivers 300 MHz of analog bandwidth on the same 5 GSa\/s, 100 Mpts platform that the 100 and 200 MHz siblings carry. Calculated rise time falls to ≤1.17 ns — fast enough to capture switching-edge detail on point-of-load converters and DC-DC supplies where slower scopes round the gate-drive waveform.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e300 MHz Bandwidth, 4 Analog Channels\u003c\/strong\u003e — Four-channel acquisition at up to 300 MHz with 5 GSa\/s sample rate (interleave) and calculated rise time of ≤1.17 ns.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e100 Mpts Memory Depth\u003c\/strong\u003e — Standard deep memory across all four channels for long capture windows without sample-rate trade.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUltra Phosphor 3.0 Display Technology\u003c\/strong\u003e — 256-level grayscale persistence with parallel FPGA mapping; up to 500,000 wfms\/s standard, 2,000,000 wfms\/s in Sequential Mode.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNine Instruments in One\u003c\/strong\u003e — Oscilloscope, 16-channel logic analyzer (optional probe), AWG (optional), 2.5 GHz spectrum analyzer, 4-digit DVM, 7-digit hardware frequency counter, protocol analyzer, Bode plot (with AWG), and power analyzer (optional).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard Protocol Decoding\u003c\/strong\u003e — RS-232\/UART, I²C, and SPI included as standard.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptional Protocols\u003c\/strong\u003e — CAN, CAN-FD, LIN, FlexRay, SENT, and Audio (I²S\/LJ\/RJ\/TDM) available as software licenses.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e16 Digital Channels (Optional)\u003c\/strong\u003e — Add mixed-signal capability with the UT-M15 logic probe pod; 1.25 GSa\/s digital sample rate, 800 ps minimum detectable pulse width.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptional 50 MHz Dual-Channel AWG\u003c\/strong\u003e — 16-bit, 250 MSa\/s arbitrary waveform generator with 200 built-in waveforms; Bode plot analyzer included with the AWG package.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eZone Triggering\u003c\/strong\u003e — Rectangle-drawn trigger conditions with Must Intersect \/ Must Not Intersect logic.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e56 Automated Measurements\u003c\/strong\u003e — Voltage, time, frequency, and statistical measurements with histogram and trend statistics; up to 27 displayed simultaneously.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e10.1-Inch Capacitive Multi-Touch\u003c\/strong\u003e — 1280×800 HD display with multi-window layout, gesture control, and HDMI output.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCPI and WebServer Remote Control\u003c\/strong\u003e — USB 3.0, LAN (VXI-11), and built-in browser-based control from PC or mobile.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFree Firmware Updates and No-Expiration License Unlocks\u003c\/strong\u003e — Firmware updates are free over the product’s lifetime; license unlocks for optional packages have no expiration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eDetailed Features\u003c\/h2\u003e\n\u003ch3\u003eNine Instruments in One\u003c\/h3\u003e\n\u003cp\u003eThe MSO2000X platform integrates nine instrument functions into one bench unit: digital storage oscilloscope, 16-channel logic analyzer (with the optional UT-M15 probe pod), 50 MHz dual-channel function and arbitrary waveform generator (optional), 2.5 GHz spectrum analyzer (FFT up to 4 Mpts), 4-digit digital voltmeter, 7-digit hardware frequency counter, multi-protocol serial-bus analyzer, Bode plot analyzer (optional, paired with the AWG for closed-loop sweep), and power-electronics analyzer (optional). For power-electronics design teams characterizing converter efficiency, harmonic distortion, and switching loss in the same bench session, the integration of optional power analysis with the four-channel acquisition path means one instrument captures the gate-drive waveform and computes the switching loss across the cycle — replacing a separate power analyzer for design-phase work.\u003c\/p\u003e\n\u003ch3\u003eHigh-Speed Acquisition — 5 GSa\/s, 100 Mpts\u003c\/h3\u003e\n\u003cp\u003eThe 5 GSa\/s real-time sample rate (interleave mode) and 100 Mpts of acquisition memory hold full waveform fidelity across the 300 MHz analog bandwidth. Standard capture rate runs up to 500,000 wfms\/s; in Sequential Mode — the segmented-memory acquisition mode that conditions captures on a trigger event — capture rate climbs to 2,000,000 wfms\/s, holding up to 125,000 frames of uninterrupted hardware real-time waveform recording for post-capture replay and analysis.\u003c\/p\u003e\n\u003cp\u003eERES (enhanced resolution) extends effective vertical resolution from the 8-bit native ADC up to 12-bit when bandwidth headroom is available — useful for low-amplitude work where quantization noise would otherwise obscure detail on switching ripple, sensor outputs, or jitter analysis.\u003c\/p\u003e\n\u003ch3\u003eUltra Phosphor 3.0 — 256-Level Grayscale Persistence\u003c\/h3\u003e\n\u003cp\u003eUltra Phosphor 3.0 is UNI-T’s third-generation waveform-mapping architecture, combining parallel FPGA acquisition with 256-level grayscale intensity grading. Throughput is five to ten times higher than the previous-generation pipeline, and acquisition dead time drops below 1 µs — the scope captures 1.17 ns fast-edge signals at 2,000,000 events per second in Sequential Mode without missing the rare-event bracket between redraws. The 256-level intensity grading shows signal frequency-of-occurrence directly: frequent waveforms appear brighter, infrequent ones dimmer, making it intuitive to distinguish normal behavior from intermittent faults during long bench captures.\u003c\/p\u003e\n\u003ch3\u003eBuilt-In Spectrum Analyzer — FFT to 4 Mpts\u003c\/h3\u003e\n\u003cp\u003eThe standard enhanced-FFT spectrum analyzer covers 0 Hz to 2.5 GHz with up to 4 Mpts of FFT length, four-channel signal analysis, four trace types (Normal, Average, Max Hold, Min Hold), and four detection modes. Marker functions cover Auto, Manual, and Threshold with a marker-point list, plus a waterfall display for tracking spectral activity over time. Use it to identify harmonics, characterize EMI signatures during pre-compliance sweeps, verify clock-signal purity on embedded designs, or analyze modulated signals — without paying for a separate spectrum analyzer.\u003c\/p\u003e\n\u003ch3\u003eProtocol Analysis — 9 Bus Types Across Four Domains\u003c\/h3\u003e\n\u003cp\u003eThe MSO2000X covers nine protocol types across four bus domains: computer serial (RS-232\/UART, I²C, SPI — standard), automotive serial (CAN, CAN-FD, LIN, FlexRay — optional), automotive sensor (SENT — optional), and audio (I²S, Left-Justified, Right-Justified, TDM — optional). Triggering and decoding are integrated: trigger on a frame error, an identifier match, a CRC failure, or a missing-ack condition, and the decode displays inline with the captured waveform. Up to four simultaneous decodes plus parallel-bus decoding (up to 18 bits, mixed analog and digital channels) cover most embedded-systems and automotive bus-validation workflows in one instrument.\u003c\/p\u003e\n\u003ch3\u003e50 MHz Dual-Channel AWG with Bode Plot (Optional)\u003c\/h3\u003e\n\u003cp\u003eThe optional MSO2000X-AWG package adds a 50 MHz dual-channel function and arbitrary waveform generator with 16-bit vertical resolution and 250 MSa\/s sample rate, plus the Bode plot analyzer for frequency-response, loop-stability, filter, and amplifier characterization. Built-in waveforms include sine, square, pulse, ramp, arbitrary, noise, and DC, with 200 standard arbitrary waveforms (Sinc, ExpRise, ExpFall, Cardiac, Gauss, Lorentz, HaverSine, and others). AM, FM, ASK, FSK, and sweep modulation are supported, and on-screen oscilloscope captures can be loaded directly into the AWG for stimulus-response replay.\u003c\/p\u003e\n\u003ch3\u003ePower Analysis (Optional) — Five Measurement Types\u003c\/h3\u003e\n\u003cp\u003eFor wide-bandwidth power-electronics validation, the optional power-analysis package extends the four-channel scope acquisition into a working power analyzer: power quality measurement, harmonic analysis to the 50th order on the AC input, surge-current characterization on inrush events, ripple analysis on output rails, and loop analysis (paired with the optional AWG and Bode plot) for closed-loop converter stability sweeps. At 300 MHz of analog bandwidth, the package handles the switching frequencies that point-of-load converters, motor drives, and DC-DC supplies operate at.\u003c\/p\u003e\n\u003ch3\u003eZone Triggering — Rectangle-Drawn Trigger Conditions\u003c\/h3\u003e\n\u003cp\u003eZone triggering isolates an occasional anomaly by trigger condition rather than waveform stability. Draw a rectangle on the display, set Must Intersect or Must Not Intersect, and the scope triggers when the waveform meets the spatial condition — two zones supported, sourced from any of CH1 through CH4. Combined with the eleven trigger types (edge, pulse width, ramp, runt pulse, over-amplitude pulse, delay, timeout, duration, setup \u0026amp; hold, Nth edge, code pattern), the zone trigger turns rare-event hunting into a defined acquisition condition rather than a wait-and-watch exercise.\u003c\/p\u003e\n\u003ch3\u003e56 Automated Measurements with Histogram and Trend Statistics\u003c\/h3\u003e\n\u003cp\u003eThe MSO2000X provides 56 automated measurement parameters on the analog channels — voltage, time, frequency, statistical, and burst measurements — with up to 27 measurements displayed simultaneously and per-channel parameter snapshots showing 39 single-channel measurements at once. Measurement statistics include mean, maximum, minimum, standard deviation, count, tendency chart, and bar chart (histogram) views. The histogram surfaces parameter distribution visually; the tendency chart shows parameter drift over time — useful for jitter analysis, long-capture characterization, and pass\/fail evidence reports.\u003c\/p\u003e\n\u003ch3\u003eFast Fuzzy Autoset — Sub-Second All-Channel Setup\u003c\/h3\u003e\n\u003cp\u003eThe MSO2000X uses a fuzzy-logic autoset algorithm built around the 7-digit hardware frequency counter and multi-channel parallel processing. All-channel autoset completes in under 1.5 seconds; single-channel autoset completes in under 1 second — useful on production-line spot-check work and education-track lab benches with frequent setup changes.\u003c\/p\u003e\n\u003ch3\u003e10.1-Inch Capacitive Multi-Touch UI\u003c\/h3\u003e\n\u003cp\u003eThe 10.1-inch 1280×800 HD capacitive multi-touch display supports the standard touch gestures (click, slide, zoom, edit, drag) for direct waveform manipulation, plus rectangle-draw for zone triggering. Multi-window layout lets multiple display panels (waveform, FFT, decode list, measurement table) be dragged and resized independently. Traditional knob-and-key controls remain for engineers who prefer them, and external mouse and keyboard input is supported via USB. HDMI output mirrors the display to an external monitor or projector — useful for instructor-led demonstrations and engineering team reviews.\u003c\/p\u003e\n\u003ch3\u003eConnectivity, SCPI, and WebServer Remote Control\u003c\/h3\u003e\n\u003cp\u003eUSB 3.0 Host (one front, two rear), USB 3.0 Device (rear), LAN (10\/100\/1000 BASE-T, VXI-11), HDMI display output, two front-panel Gen Out connectors (paired with the optional AWG), 10 MHz reference In\/Out, and AUX Out (Trig Out \/ Pass-Fail \/ DVM). The instrument supports the full SCPI command set, and the built-in WebServer provides browser-based remote control from PC or mobile.\u003c\/p\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003ch3\u003eFor R\u0026amp;D Engineers\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFor high-bandwidth R\u0026amp;D validation, the MSO2304X covers ARM Cortex-A and FPGA-class silicon debug at 300 MHz, four-channel timing-correlated mixed-signal analysis (with the UT-M15 logic probe pod), and higher-speed protocol decode where the rise-time edge of the analog signal-integrity story matters — faster microcontroller reference designs, mid-speed FPGA peripherals, and embedded-Linux SoC validation.\u003c\/li\u003e\n\u003cli\u003eTime-correlated mixed-signal capture across analog channels and 16 digital lines (with the UT-M15 probe pod) on the same instrument and the same trigger event.\u003c\/li\u003e\n\u003cli\u003eStandard SPI, I²C, and RS-232\/UART decoding inline with captured waveforms; up to four simultaneous decodes plus parallel-bus decoding for custom protocols.\u003c\/li\u003e\n\u003cli\u003eZone triggering for rare-event hunting on intermittent timing anomalies, runts, and glitches.\u003c\/li\u003e\n\u003cli\u003e56 automated measurements with histogram and trend statistics for jitter analysis and long-capture characterization.\u003c\/li\u003e\n\u003cli\u003eFree firmware updates over the product’s lifetime; license unlocks for optional packages have no expiration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFor Power Electronics Engineers\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFor switching-mode power-supply design, motor-drive validation, and DC-DC converter characterization, the MSO2304X pairs four-channel acquisition with optional power-analysis software for switching-loss, efficiency, harmonic-distortion, and ripple measurement on the same instrument that captures the scope traces — useful for design-phase power-electronics work where a separate power analyzer is not on the bench.\u003c\/li\u003e\n\u003cli\u003eOptional power-analysis package adds power quality, harmonic analysis, surge current, ripple analysis, and loop analysis (paired with the optional AWG and Bode plot for closed-loop sweep).\u003c\/li\u003e\n\u003cli\u003eFour-channel acquisition supports vIN \/ vOUT \/ IL \/ vGS measurement on switching converters and DC-DC supplies.\u003c\/li\u003e\n\u003cli\u003eOptional dual-channel 50 MHz AWG with Bode plot for closed-loop frequency-response and stability analysis on power-supply controllers.\u003c\/li\u003e\n\u003cli\u003eSequential Mode captures 125,000 frames of triggered events for fault-recovery and burst-mode analysis on intermittent power events.\u003c\/li\u003e\n\u003cli\u003eHigh-voltage differential probes (UT-P30\/P31\/P32\/P33), high-current probes (UT-P40\/P41\/P42\/P43), and the UT-ISOT isolation transformer all compatible.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO2304X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAnalog Bandwidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e300 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCalculated Rise Time (10% to 90%, typical)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤1.17 ns\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAnalog Channels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDigital Channels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 (with optional UT-M15 probe pod)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Real-Time Sample Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 GSa\/s (interleave) \/ 2.5 GSa\/s (non-interleave)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Digital Sample Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.25 GSa\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Memory Depth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 Mpts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVertical Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8-bit native; up to 12-bit via ERES\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandard Capture Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500,000 wfms\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSequential Mode Capture Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2,000,000 wfms\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHardware Real-Time Recording\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e125,000 frames\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum Detectable Pulse Width (digital)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 ps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrigger Types\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEdge, pulse width, ramp, runt pulse, over-amplitude pulse, delay, timeout, duration, setup \u0026amp; hold, Nth edge, code pattern, video, zone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtocol Decoding (Standard)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRS-232\/UART, I²C, SPI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtocol Decoding (Optional)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCAN, CAN-FD, LIN, FlexRay, SENT, Audio (I²S\/LJ\/RJ\/TDM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSpectrum Analyzer (FFT)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 Hz to 2.5 GHz, up to 4 Mpts FFT, 4 traces, 4 detections, waterfall\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAWG (Optional MSO2000X-AWG)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 MHz, 2 channels, 16-bit, 250 MSa\/s; includes Bode plot analyzer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Analysis (Optional MSO2000X-PWR)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower quality, harmonic analysis, surge current, ripple analysis, loop analysis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAutomated Measurements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e56 (analog channels); up to 27 displayed simultaneously\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDigital Voltmeter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4-digit (DC, AC RMS, DC+AC RMS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency Counter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7-digit hardware counter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10.1-inch 1280×800 capacitive multi-touch, 24-bit color\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterfaces\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSB 3.0 Host (3) \/ USB 3.0 Device (1) \/ LAN (VXI-11) \/ HDMI \/ Gen Out (2) \/ 10 MHz In\/Out \/ AUX Out\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRemote Control\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSCPI; built-in WebServer (PC and mobile)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Source\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100–240 VAC, 50\/60 Hz; 120 W max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4\u003eDownloads\u003c\/h4\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cbr\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/MSO3000X_-_MSO2000X_-_User_Manual_-_V1.2.pdf\" target=\"_blank\" title=\"MSO2000X Series Datasheet\" rel=\"noopener\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/pdf-icon-63x63_480x480.png\" style=\"float: left;\" alt=\"PDF\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/850009-i.pdf\" target=\"_blank\"\u003e\u003cbr\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/MSO3000X_-_MSO2000X_-_User_Manual_-_V1.2.pdf\"\u003eUNI-T MSO2000X Series Datasheet\u003c\/a\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cbr\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/MSO3000X_-_MSO2000X_-_User_Manual_-_V1.2.pdf\" target=\"_blank\" title=\"UNI-T MSO2000X Series Users Manual\" rel=\"noopener\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/pdf-icon-63x63_480x480.png\" style=\"float: left;\" alt=\"PDF\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/850009-i.pdf\" target=\"_blank\"\u003e\u003cbr\u003e\u003c\/a\u003e\u003ca rel=\"noopener\" title=\"UNI-T MSO3000X Series Users Manual\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/MSO3000X_-_MSO2000X_-_User_Manual_-_V1.2.pdf\" target=\"_blank\"\u003eUNI-T MSO2000X Series Users Manual\u003c\/a\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eOptions \u0026amp; Accessories\u003c\/h4\u003e\n\u003ch3\u003eIncluded\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUT-P06 (300 MHz, 10:1 \/ 1:1) × 4 passive probes (one per channel)\u003c\/li\u003e\n\u003cli\u003eUT-D30 USB 3.0 cable\u003c\/li\u003e\n\u003cli\u003eUT-L45 BNC-to-BNC direct-through cable\u003c\/li\u003e\n\u003cli\u003eUT-L02A BNC red and black alligator connecting wire\u003c\/li\u003e\n\u003cli\u003eNational-standard power cable\u003c\/li\u003e\n\u003cli\u003eQuick start guide\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAvailable Options\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMSO2000X-AWG — Dual-channel 50 MHz AWG with Bode plot analyzer\u003c\/li\u003e\n\u003cli\u003eMSO2000X-PWR — Power analysis package (5 measurement types)\u003c\/li\u003e\n\u003cli\u003eMSO2000X-BND — All serial-bus triggering and decoding (CAN, CAN-FD, LIN, FlexRay, SENT, Audio)\u003c\/li\u003e\n\u003cli\u003eMSO2000X-AUTO — Automotive serial bus bundle (CAN, CAN-FD, LIN, FlexRay, SENT)\u003c\/li\u003e\n\u003cli\u003eMSO2000X-CAN \/ MSO2000X-CAN-FD \/ MSO2000X-LIN \/ MSO2000X-FLEX \/ MSO2000X-SENT \/ MSO2000X-AUDIO — Individual protocol licenses\u003c\/li\u003e\n\u003cli\u003eBandwidth upgrades: MSO2000X-BW1MT2M (100→200), MSO2000X-BW1MT3M (100→300), MSO2000X-BW2MT3M (200→300)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eRecommended Accessories\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUT-M15 — 16-channel logic probe pod\u003c\/li\u003e\n\u003cli\u003eUT-P07A — 500 MHz high-resistance passive probe\u003c\/li\u003e\n\u003cli\u003eUT-P20 \/ UT-P21 — High-voltage probes\u003c\/li\u003e\n\u003cli\u003eUT-P30 \/ UT-P31 \/ UT-P32 \/ UT-P33 — High-voltage differential probes\u003c\/li\u003e\n\u003cli\u003eUT-P40 \/ UT-P41 \/ UT-P42 \/ UT-P43 \/ UT-P44 — Current probes\u003c\/li\u003e\n\u003cli\u003eUT-ISOT — Isolation transformer\u003c\/li\u003e\n\u003cli\u003eUT-M13X — Oscilloscope demo board\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSoftware Options\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMSO2000X-AUDIO — Serial Bus Trigger and Analysis Option (I2S, LJ, RJ, TDM)\u003c\/li\u003e\n\u003cli\u003eMSO2000X-AUTO — Serial Bus Trigger and Decode Option (CAN, CAN-FD, LIN, FlexRay, SENT)\u003c\/li\u003e\n\u003cli\u003eMSO2000X-AWG — Arbitrary Waveform Generator Option\u003c\/li\u003e\n\u003cli\u003eMSO2000X-BND — Serial Bus Trigger and Decode Bundle (incl. AUTO, AUDIO)\u003c\/li\u003e\n\u003cli\u003eMSO2000X-CAN — Automotive CAN Serial Bus Trigger and Analysis\u003c\/li\u003e\n\u003cli\u003eMSO2000X-CANFD — Automotive CAN-FD Serial Bus Trigger and Analysis\u003c\/li\u003e\n\u003cli\u003eMSO2000X-FLEX — Automotive FlexRay Serial Bus Trigger and Analysis\u003c\/li\u003e\n\u003cli\u003eMSO2000X-LIN — Automotive LIN Serial Bus Trigger and Analysis\u003c\/li\u003e\n\u003cli\u003eMSO2000X-PWR — Power Analysis Option\u003c\/li\u003e\n\u003cli\u003eMSO2000X-SENT — Automotive SENT Sensor Bus Trigger and Analysis\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFamily Members\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMSO2104X (100 MHz, 4-channel)\u003c\/li\u003e\n\u003cli\u003eMSO2204X (200 MHz, 4-channel)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFAQ's\u003c\/h4\u003e\n\u003ch3\u003eWhat’s the difference between standard capture rate and Sequential Mode capture rate?\u003c\/h3\u003e\n\u003cp\u003eStandard capture rate (500,000 wfms\/s) is the rate at which the MSO2304X acquires waveforms during continuous real-time operation. Sequential Mode (2,000,000 wfms\/s) uses segmented memory to condition captures on a trigger event, holding up to 125,000 frames of triggered acquisitions for post-capture replay. Use standard mode for general waveform observation; use Sequential Mode for rare-event hunting where the trigger condition is well-defined and the captures-per-second matter.\u003c\/p\u003e\n\u003ch3\u003eIs the MSO2304X a 12-bit oscilloscope?\u003c\/h3\u003e\n\u003cp\u003eNo. The MSO2304X has an 8-bit native ADC with up to 12-bit effective resolution via ERES (enhanced resolution) when bandwidth headroom is available. For native 12-bit acquisition at full bandwidth and full sample rate, see UNI-T’s HD-series oscilloscopes (UPO1000HD, UPO2000HD, MSO1000HD, MSO3000HD, MSO5000HD, MSO8000HD), which use the R12™ native 12-bit ADC architecture.\u003c\/p\u003e\n\u003ch3\u003eAre the 16 digital channels included?\u003c\/h3\u003e\n\u003cp\u003eThe 16-digital-channel logic-analyzer front end is built into the chassis, but using it requires the optional UT-M15 probe pod. Without the UT-M15, the MSO2304X operates as a 4-channel digital storage oscilloscope.\u003c\/p\u003e\n\u003ch3\u003eWhat’s included with the AWG option?\u003c\/h3\u003e\n\u003cp\u003eThe MSO2000X-AWG package adds a 50 MHz dual-channel function and arbitrary waveform generator with 16-bit vertical resolution, 250 MSa\/s sample rate, and 200 built-in arbitrary waveforms. The Bode plot analyzer is included with the AWG package — it uses the AWG for stimulus and the scope channels for response measurement.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Uni-Trend US","offers":[{"title":"181100300067X","offer_id":53265475928288,"sku":"181100300067X","price":1839.2,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/MSO2000X_1_sq_9d980de7-a36f-41da-8ca0-945a253cf473.jpg?v=1782858082"},{"product_id":"mso3054x-500-mhz-4ch-mixed-signal-oscilloscope","title":"MSO3054X 500 MHz 4Ch Mixed Signal Oscilloscope","description":"\u003ch1\u003eThe MSO3054X is a 500 MHz, four-channel mixed-signal oscilloscope.\u003c\/h1\u003e\n\u003cp\u003eWith 5 GSa\/s real-time sample rate, 500 Mpts of acquisition memory, 16 logic-analyzer channels (with the optional UT-M15 probe pod), and Ultra Phosphor 3.0 waveform mapping at up to 2,000,000 wfms\/s in Sequential Mode, the MSO3054X consolidates nine bench instruments into one 10.1-inch capacitive multi-touch footprint — oscilloscope, logic analyzer, AWG, spectrum analyzer, DVM, frequency counter, protocol analyzer, Bode plot, and power analyzer.\u003c\/p\u003e\n\u003cp\u003eFor wide-bandwidth power-electronics design, mixed-signal validation across faster MCU and FPGA silicon, switching-converter characterization at the 100s of MHz tier, and small-lab consolidation across multiple instrument categories, the MSO3054X is the top SKU in the MSO3000X line. Calculated rise time falls to ≤0.7 ns — fast enough to resolve the leading edges on wide-bandgap (GaN, SiC) switching devices and the rise-time content of high-speed digital signals where 350 MHz scopes start to round corners. The 12-protocol decode set extends to aerospace serial buses (MIL-STD-1553B, ARINC 429, Manchester) for design-phase work on avionics, defense electronics, and instrumentation systems.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e500 MHz Bandwidth, 4 Analog Channels\u003c\/strong\u003e — Four-channel acquisition at up to 500 MHz with 5 GSa\/s sample rate (interleave) and calculated rise time of ≤0.7 ns — fast enough to capture leading-edge content on GaN and SiC switching devices, high-speed digital interfaces, and full-bandwidth signal-integrity analysis.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e500 Mpts Memory Depth\u003c\/strong\u003e — Standard deep memory across all four channels for long capture windows without sample-rate trade.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUltra Phosphor 3.0 Display Technology\u003c\/strong\u003e — 256-level grayscale persistence with parallel FPGA mapping; up to 800,000 wfms\/s standard, 2,000,000 wfms\/s in Sequential Mode.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNine Instruments in One\u003c\/strong\u003e — Oscilloscope, 16-channel logic analyzer (optional probe), AWG (optional), 1.25 GHz spectrum analyzer, 4-digit DVM, 7-digit hardware frequency counter, protocol analyzer, Bode plot (with AWG), and six-measurement power analyzer (optional).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard Protocol Decoding\u003c\/strong\u003e — RS-232\/422\/485\/UART, I²C, and SPI included as standard.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptional Protocol Decoding\u003c\/strong\u003e — CAN, CAN-FD, LIN, FlexRay, SENT, Audio (I²S\/LJ\/RJ\/TDM), MIL-STD-1553B, ARINC 429, and Manchester — 12 protocols total across computer, automotive, audio, aerospace, and wireless domains.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e16 Digital Channels (Optional)\u003c\/strong\u003e — Add mixed-signal capability with the UT-M15 logic probe pod; 1.25 GSa\/s digital sample rate, 800 ps minimum detectable pulse width.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptional 50 MHz Dual-Channel AWG with Bode Plot\u003c\/strong\u003e — 16-bit, 250 MSa\/s arbitrary waveform generator with the Bode plot analyzer included for closed-loop frequency-response analysis.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eZone Triggering\u003c\/strong\u003e — Rectangle-drawn trigger conditions with Must Intersect \/ Must Not Intersect logic, plus eleven additional trigger types.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e54 Automated Measurements\u003c\/strong\u003e — Voltage, time, frequency, and statistical measurements with histogram and trend statistics; up to 27 displayed simultaneously.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e10.1-Inch Capacitive Multi-Touch\u003c\/strong\u003e — 1280×800 HD display with multi-window layout, gesture control, and HDMI output.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCPI and WebServer Remote Control\u003c\/strong\u003e — USB 3.0, LAN (VXI-11), and built-in browser-based control from PC or mobile.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFree Firmware Updates and No-Expiration License Unlocks\u003c\/strong\u003e — Firmware updates are free over the product’s lifetime; license unlocks for optional packages have no expiration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eDetailed Features\u003c\/h2\u003e\n\u003ch3\u003eNine Instruments in One\u003c\/h3\u003e\n\u003cp\u003eThe MSO3000X integrates nine instrument functions into one bench unit: digital storage oscilloscope, 16-channel logic analyzer (with the optional UT-M15 probe pod), 50 MHz dual-channel function and arbitrary waveform generator (optional), 1.25 GHz spectrum analyzer (FFT up to 4 Mpts), 4-digit DVM, 7-digit hardware frequency counter, multi-protocol serial-bus analyzer covering 12 bus types, Bode plot analyzer (optional, paired with the AWG for closed-loop sweep), and a six-measurement power-electronics analyzer (optional). For lab benches and small-lab consolidations covering scope, spectrum, protocol decode, AWG-driven stimulus, power analysis, and Bode-plot loop analysis — instruments that would otherwise occupy four to six rack slots and four to six calibration cycles — the integration condenses the bench footprint into one operator surface and one calibration event. For independent test labs validating customer designs across multiple categories, the consolidated nine-instrument view is the operational differentiator.\u003c\/p\u003e\n\u003ch3\u003eHigh-Speed Acquisition — 5 GSa\/s, 500 Mpts\u003c\/h3\u003e\n\u003cp\u003eThe 5 GSa\/s real-time sample rate (interleave) and 500 Mpts of acquisition memory hold full waveform fidelity across the 500 MHz analog bandwidth. Standard capture rate runs up to 800,000 wfms\/s; in Sequential Mode — the segmented-memory mode that conditions captures on a trigger event — capture rate climbs to 2,000,000 wfms\/s, recording up to 200,000 frames for post-capture replay and analysis.\u003c\/p\u003e\n\u003ch3\u003eDeep Memory — 500 Mpts Per Acquisition\u003c\/h3\u003e\n\u003cp\u003eThe 500 Mpts memory depth supports the deepest acquisition windows in the MSO3000X line at full sample rate — capturing tens of thousands of waveforms in a single acquisition for post-event analysis. With Sequential Mode recording up to 200,000 frames, rare-event hunting on high-traffic protocol buses and switching-converter transient capture across long fault-recovery cycles becomes a defined operation rather than a wait-and-watch exercise. For independent test labs validating customer designs, the deep-memory budget makes pass\/fail evidence reports comprehensive on the first capture.\u003c\/p\u003e\n\u003ch3\u003eVertical Resolution — 8-Bit Native with ERES to 12-Bit\u003c\/h3\u003e\n\u003cp\u003eThe MSO3054X uses an 8-bit native ADC with up to 12-bit effective resolution via ERES (enhanced resolution) when bandwidth headroom is available — useful for low-amplitude signal work where quantization noise would obscure detail on switching ripple, sensor outputs, or jitter analysis at the higher-bandwidth tier. For applications requiring native 12-bit resolution at full 500 MHz bandwidth, see UNI-T’s MSO3000HD-series scopes, which use the R12™ native 12-bit ADC architecture for power-electronics ripple-on-bias measurements where the signal-of-interest sits on a high-amplitude DC offset.\u003c\/p\u003e\n\u003ch3\u003eUltra Phosphor 3.0 — 256-Level Grayscale Persistence\u003c\/h3\u003e\n\u003cp\u003eUltra Phosphor 3.0 is UNI-T’s third-generation waveform-mapping architecture: parallel FPGA acquisition with 256-level grayscale intensity grading, a 20 Gbps internal data path, and sub-1 µs dead time. The scope captures fast-edge signals at 2,000,000 events per second in Sequential Mode without missing the rare-event bracket between redraws. Intensity grading shows frequency-of-occurrence directly — frequent waveforms appear brighter, infrequent ones dimmer — making intermittent faults easy to distinguish from normal behavior.\u003c\/p\u003e\n\u003ch3\u003eBuilt-In Spectrum Analyzer — FFT to 4 Mpts\u003c\/h3\u003e\n\u003cp\u003eThe standard enhanced-FFT spectrum analyzer covers 0 Hz to 1.25 GHz with up to 4 Mpts FFT length, four-channel analysis, four trace types (Normal, Average, Max Hold, Min Hold), and four detection modes. Markers plus a waterfall display track spectral activity over time — for harmonic ID, EMI pre-compliance sweeps, clock-purity verification, and modulated-signal analysis without the cable swap a separate spectrum analyzer requires.\u003c\/p\u003e\n\u003ch3\u003eProtocol Analysis — 12 Bus Types Across Five Domains\u003c\/h3\u003e\n\u003cp\u003eTwelve protocols across five bus domains: computer serial (RS-232\/422\/485\/UART, I²C, SPI — standard); automotive (CAN, CAN-FD, LIN, FlexRay, SENT — optional); audio (I²S, LJ, RJ, TDM — optional); aerospace (MIL-STD-1553B, ARINC 429 — optional); and Manchester wireless (optional). Triggering and decoding are integrated — trigger on a frame error, identifier match, CRC failure, or missing-ack condition, and the decode displays inline with the captured waveform. The aerospace and Manchester decode set differentiates this protocol envelope from mid-tier scopes that stop at automotive and audio.\u003c\/p\u003e\n\u003ch3\u003e50 MHz Dual-Channel AWG with Bode Plot (Optional)\u003c\/h3\u003e\n\u003cp\u003eThe optional MSO3000X-AWG package adds a 50 MHz dual-channel function\/arbitrary waveform generator (16-bit, 250 MSa\/s) plus the Bode plot analyzer for frequency-response, loop-stability, filter, and amplifier characterization. Built-in waveforms include sine, square, pulse, ramp, arbitrary, noise, and DC, with AM, FM, ASK, FSK, and sweep modulation. On-screen captures load directly into the AWG for stimulus-response replay.\u003c\/p\u003e\n\u003ch3\u003ePower Analysis (Optional) — Six Measurement Types\u003c\/h3\u003e\n\u003cp\u003eFor wide-bandwidth power-electronics validation on GaN and SiC switching converters, high-frequency motor drives, and full-bandwidth DC-DC characterization, the optional power-analysis package extends the four-channel scope acquisition into a working power analyzer: power quality measurement, harmonic analysis to the 50th order, switching loss across the cycle, ripple analysis on output rails, loop analysis (paired with the Bode plot included with the optional AWG) for closed-loop stability sweeps, and safe operating area visualization for device-stress validation. At 500 MHz of analog bandwidth, the package handles the switching frequencies that wide-bandgap converters and high-speed PoL designs operate at.\u003c\/p\u003e\n\u003ch3\u003eZone Triggering — Rectangle-Drawn Trigger Conditions\u003c\/h3\u003e\n\u003cp\u003eZone triggering isolates an occasional anomaly by trigger condition rather than waveform stability. Draw a rectangle on the display, set Must Intersect or Must Not Intersect, and the scope triggers when the waveform meets the spatial condition. With eleven additional trigger types (edge, pulse width, ramp, runt, over-amplitude, delay, timeout, duration, setup \u0026amp; hold, Nth edge, code pattern), zone triggering turns rare-event hunting into a defined acquisition.\u003c\/p\u003e\n\u003ch3\u003e54 Automated Measurements with Histogram and Trend Statistics\u003c\/h3\u003e\n\u003cp\u003e54 automated measurement parameters on the analog channels — voltage, time, frequency, statistical, and burst measurements — with up to 27 displayed simultaneously. Statistics include mean, max, min, standard deviation, count, tendency chart, and histogram. The burst function reports values across burst segments — useful for jitter analysis, long-capture characterization, and pass\/fail evidence reports.\u003c\/p\u003e\n\u003ch3\u003eFast Fuzzy Autoset\u003c\/h3\u003e\n\u003cp\u003eThe fuzzy-logic autoset algorithm uses the 7-digit hardware frequency counter and multi-channel parallel processing to lock onto unknown signals quickly: all-channel autoset in under 1.5 seconds, single-channel under 1 second — meaningful on production-line spot-check work and engineering benches that swap test articles often.\u003c\/p\u003e\n\u003ch3\u003e10.1-Inch Capacitive Multi-Touch UI\u003c\/h3\u003e\n\u003cp\u003eThe 10.1-inch 1280×800 HD capacitive multi-touch display supports standard touch gestures (click, slide, zoom, edit, drag) for direct waveform manipulation, plus rectangle-draw for zone triggering. Multi-window layout lets waveform, FFT, decode-list, and measurement-table panels be dragged and resized independently. Knob-and-key controls remain; HDMI output mirrors the display to an external monitor or projector.\u003c\/p\u003e\n\u003ch3\u003eConnectivity, SCPI, and WebServer Remote Control\u003c\/h3\u003e\n\u003cp\u003eUSB 3.0 Host (one front, two rear), USB 3.0 Device, LAN (10\/100\/1000 BASE-T, VXI-11), HDMI display output, two front-panel Gen Out connectors (paired with the optional AWG), 10 MHz reference In\/Out, and AUX Out (Trig Out \/ Pass-Fail \/ DVM). Full SCPI command set; the built-in WebServer provides browser-based remote control from PC or mobile without driver installation.\u003c\/p\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003ch3\u003eFor R\u0026amp;D Engineers\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFor wide-bandwidth R\u0026amp;D validation at 500 MHz, the MSO3054X covers ARM Cortex-A and FPGA-class silicon debug, four-channel time-correlated mixed-signal work (with the UT-M15 logic probe pod), and full-bandwidth protocol decode where the rise-time edge of the analog signal-integrity story matters — faster microcontroller reference designs, FPGA peripherals at higher data rates, embedded-Linux SoC validation, and high-speed digital bus characterization.\u003c\/li\u003e\n\u003cli\u003eTime-correlated mixed-signal capture across analog channels and 16 digital lines (with the UT-M15 probe pod) on the same instrument and the same trigger event.\u003c\/li\u003e\n\u003cli\u003e12-protocol decode set covering computer, automotive, audio, aerospace, and Manchester-wireless buses; up to four simultaneous decodes plus event list and search.\u003c\/li\u003e\n\u003cli\u003eZone triggering for rare-event hunting on intermittent timing anomalies, runts, and glitches; eleven trigger types cover the full embedded-systems debug envelope.\u003c\/li\u003e\n\u003cli\u003e500 Mpts memory captures long acquisition windows for protocol-event hunting and post-event analysis; Sequential Mode records up to 200,000 frames of triggered events.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFor Power Electronics Engineers\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFor wide-bandgap (GaN, SiC) power-electronics design, full-bandwidth motor-drive validation, high-speed DC-DC converter characterization, and fast-edge switching analysis, the MSO3054X pairs 500 MHz of analog bandwidth with the optional six-measurement power-analysis suite, the optional 50 MHz AWG and Bode plot analyzer for closed-loop stability sweeps, and 200,000-frame Sequential Mode for fault-event capture across long transient windows — the full converter-design workflow on one instrument.\u003c\/li\u003e\n\u003cli\u003eOptional six-measurement power-analysis package: power quality, harmonic analysis, switching loss, ripple analysis, loop analysis, and safe operating area visualization.\u003c\/li\u003e\n\u003cli\u003eFour-channel acquisition supports vIN \/ vOUT \/ IL \/ vGS measurement on switching converters and DC-DC supplies in a single time-correlated capture.\u003c\/li\u003e\n\u003cli\u003eOptional dual-channel 50 MHz AWG with Bode plot analyzer for closed-loop frequency-response and stability sweeps on power-supply controllers.\u003c\/li\u003e\n\u003cli\u003eSequential Mode captures 200,000 frames of triggered events for fault-recovery and burst-mode analysis on intermittent power events and load-step transients.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFor Test Labs and Design Consultancies\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFor independent test labs and design consultancies validating customer designs across multiple instrument categories, the MSO3054X consolidates oscilloscope, spectrum analyzer, protocol decoder, AWG, Bode plot analyzer, and power analyzer on one operator surface — reducing rack count and calibration overhead while covering the standard test-lab measurement envelope. The 12-protocol decode set (including MIL-STD-1553B, ARINC 429, and Manchester) supports aerospace and defense-electronics validation work that mid-tier scopes leave on the option list.\u003c\/li\u003e\n\u003cli\u003eNine-in-one consolidation reduces rack count and calibration overhead across scope, spectrum, protocol decode, AWG, Bode plot, and power-analysis categories on independent test benches.\u003c\/li\u003e\n\u003cli\u003e12-protocol decode set including aerospace (MIL-STD-1553B, ARINC 429) and Manchester-wireless covers customer-design validation work that mid-tier scopes leave on the option list.\u003c\/li\u003e\n\u003cli\u003eSCPI command set and WebServer remote control support script-driven automated test sequences and remote-bench workflows for distributed lab teams.\u003c\/li\u003e\n\u003cli\u003eSequential Mode 200,000-frame recording and 500 Mpts deep memory make pass\/fail evidence reports comprehensive on the first capture — reducing customer-bench rework.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO3054X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAnalog Bandwidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCalculated Rise Time (10% to 90%, typical)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤0.7 ns\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAnalog Channels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 (plus 1 external trigger channel)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDigital Channels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 (with optional UT-M15 probe pod)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Real-Time Sample Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 GSa\/s (interleave) \/ 2.5 GSa\/s (non-interleave)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Digital Sample Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.25 GSa\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Memory Depth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 Mpts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVertical Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8-bit native; up to 12-bit via ERES\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandard Capture Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800,000 wfms\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSequential Mode Capture Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2,000,000 wfms\/s (up to 200,000 frames recorded)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrigger Types\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEdge, pulse width, ramp, runt pulse, over-amplitude pulse, delay, timeout, duration, setup \u0026amp; hold, Nth edge, code pattern, video, zone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtocol Decoding (Standard)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRS-232\/422\/485\/UART, I²C, SPI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtocol Decoding (Optional)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCAN, CAN-FD, LIN, FlexRay, SENT, Audio (I²S\/LJ\/RJ\/TDM), MIL-STD-1553B, ARINC 429, Manchester\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSpectrum Analyzer (FFT)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 Hz to 1.25 GHz, up to 4 Mpts FFT, 4 traces, 4 detections, waterfall\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAWG (Optional MSO3000X-AWG)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 MHz, 2 channels, 16-bit, 250 MSa\/s; includes Bode plot analyzer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Analysis (Optional MSO3000X-PWR)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower quality, harmonic analysis, switching loss, ripple analysis, loop analysis, safe operating area\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAutomated Measurements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e54 (analog channels); up to 27 displayed simultaneously\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10.1-inch 1280×800 capacitive multi-touch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterfaces\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSB 3.0 Host (3) \/ USB 3.0 Device (1) \/ LAN (VXI-11) \/ HDMI \/ Gen Out (2) \/ 10 MHz In\/Out \/ AUX Out\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRemote Control\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSCPI; built-in WebServer (PC and mobile)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCE, cETLus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003e\u003c\/h4\u003e\n\u003ch4\u003eDownloads\u003c\/h4\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cbr\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/MSO3000X_-_MSO2000X_-_User_Manual_-_V1.2.pdf\" title=\"MSO3000X Series Datasheet\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg alt=\"PDF\" style=\"float: left;\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/pdf-icon-63x63_480x480.png\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/850009-i.pdf\" target=\"_blank\"\u003e\u003cbr\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/MSO3000X_-_MSO2000X_-_User_Manual_-_V1.2.pdf\"\u003eUNI-T MSO3000X Series Datasheet\u003c\/a\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cbr\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/MSO3000X_-_MSO2000X_-_User_Manual_-_V1.2.pdf\" title=\"UNI-T MSO3000X Series Users Manual\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg alt=\"PDF\" style=\"float: left;\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/pdf-icon-63x63_480x480.png\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/850009-i.pdf\" target=\"_blank\"\u003e\u003cbr\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/MSO3000X_-_MSO2000X_-_User_Manual_-_V1.2.pdf\" title=\"UNI-T MSO3000X Series Users Manual\" rel=\"noopener\" target=\"_blank\"\u003eUNI-T MSO3000X Series Users Manual\u003c\/a\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eOptions \u0026amp; Accessories\u003c\/h4\u003e\n\u003ch3\u003eIncluded\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUT-P07A (500 MHz, 10:1) × 4 passive probes (one per channel)\u003c\/li\u003e\n\u003cli\u003eUT-D30 USB 3.0 cable\u003c\/li\u003e\n\u003cli\u003eUT-L45 BNC-to-BNC direct-through cable\u003c\/li\u003e\n\u003cli\u003eUT-L02A BNC red and black alligator connecting wire\u003c\/li\u003e\n\u003cli\u003eNational-standard power cable\u003c\/li\u003e\n\u003cli\u003eQuick start guide\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAvailable Options\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMSO3000X-AWG — Dual-channel 50 MHz AWG with Bode plot analyzer\u003c\/li\u003e\n\u003cli\u003eMSO3000X-PWR — Power analysis package (6 measurement types)\u003c\/li\u003e\n\u003cli\u003eMSO3000X-BND — Full serial-bus triggering and decoding bundle (AUTO + AUDIO + MIL-STD + ARINC429 + MANCH)\u003c\/li\u003e\n\u003cli\u003eMSO3000X-AUTO — Automotive serial bus bundle (CAN, CAN-FD, LIN, FlexRay, SENT)\u003c\/li\u003e\n\u003cli\u003eIndividual protocol licenses: CAN, CAN-FD, LIN, FlexRay, SENT, AUDIO, MIL1553, ARINC429, MANCH\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eRecommended Accessories\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUT-M15 — 16-channel logic probe pod\u003c\/li\u003e\n\u003cli\u003eUT-PA2000 — 2 GHz active probe (auto-sense attenuation, ±8 V offset range)\u003c\/li\u003e\n\u003cli\u003eUT-P07A — 500 MHz high-resistance passive probe\u003c\/li\u003e\n\u003cli\u003eUT-P20 \/ UT-P21 — High-voltage probes\u003c\/li\u003e\n\u003cli\u003eUT-P30 \/ UT-P31 \/ UT-P32 \/ UT-P33 — High-voltage differential probes\u003c\/li\u003e\n\u003cli\u003eUT-P40 \/ UT-P41 \/ UT-P42 \/ UT-P43 \/ UT-P44 — Current probes\u003c\/li\u003e\n\u003cli\u003eUT-ISOT — Isolation transformer\u003c\/li\u003e\n\u003cli\u003eUT-M13X — Oscilloscope demo board\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSoftware Options\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMSO3000X-ARINC429 — Aerospace ARINC429 Serial Bus Trigger and Analysis\u003c\/li\u003e\n\u003cli\u003eMSO3000X-AUDIO — Serial Bus Trigger and Analysis Option (I2S, LJ, RJ, TDM)\u003c\/li\u003e\n\u003cli\u003eMSO3000X-AUTO — Serial Bus Trigger and Decode Bundle (CAN, CAN-FD, LIN, FlexRay, SENT)\u003c\/li\u003e\n\u003cli\u003eMSO3000X-AWG — Arbitrary Waveform Generator option\u003c\/li\u003e\n\u003cli\u003eMSO3000X-BND — Serial Bus Trigger and Decode Bundle (incl. AUTO, AUDIO, MIL-STD, ARINC429, MANCH)\u003c\/li\u003e\n\u003cli\u003eMSO3000X-CAN — Automotive CAN Serial Bus Trigger and Analysis\u003c\/li\u003e\n\u003cli\u003eMSO3000X-CANFD — Automotive CAN-FD Serial Bus Trigger and Analysis\u003c\/li\u003e\n\u003cli\u003eMSO3000X-FLEX — Automotive FlexRay Serial Bus Trigger and Analysis\u003c\/li\u003e\n\u003cli\u003eMSO3000X-LIN — Automotive LIN Serial Bus Trigger and Analysis\u003c\/li\u003e\n\u003cli\u003eMSO3000X-MANCH — Manchester Serial Bus Trigger and Analysis Option\u003c\/li\u003e\n\u003cli\u003eMSO3000X-MIL1553 — MIL-STD-1553 Serial Bus Trigger and Analysis Option\u003c\/li\u003e\n\u003cli\u003eMSO3000X-PWR — Power Analysis Option\u003c\/li\u003e\n\u003cli\u003eMSO3000X-SENT — Automotive SENT Sensor Bus Trigger and Analysis\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFamily Members and Related Scopes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMSO3034X (350 MHz, 4-channel)\u003c\/li\u003e\n\u003cli\u003eMSO7000X-series (1 GHz \/ 2 GHz)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFAQ's\u003c\/h4\u003e\n\u003ch3\u003eWhat’s the difference between standard capture rate and Sequential Mode capture rate?\u003c\/h3\u003e\n\u003cp\u003eStandard capture rate (800,000 wfms\/s) is the rate at which the MSO3054X acquires waveforms during continuous real-time operation. Sequential Mode (2,000,000 wfms\/s) uses segmented memory to condition captures on a trigger event, holding up to 200,000 frames of triggered acquisitions for post-capture replay. Use standard mode for general waveform observation; use Sequential Mode for rare-event hunting where the trigger condition is well-defined.\u003c\/p\u003e\n\u003ch3\u003eHow does the MSO3054X compare to the MSO3000HD-series scopes?\u003c\/h3\u003e\n\u003cp\u003eThe MSO3054X and the MSO3000HD-series share the same 4-channel mixed-signal platform at 200–500 MHz and the same 9-in-1 multi-instrument feature set. The architectural difference is the ADC: the MSO3054X uses an 8-bit native ADC with up to 12-bit ERES; the MSO3000HD-series uses UNI-T’s R12™ native 12-bit ADC at full bandwidth. Choose the MSO3054X when 500 MHz bandwidth and 12-protocol decode breadth (including aerospace buses) are the priorities. Choose an MSO3000HD-series scope when the design requires native 12-bit resolution at full bandwidth — for example, ripple-on-bias measurement on a 400 V DC rail where the signal of interest sits on a large DC offset that 8-bit dynamic range cannot resolve cleanly.\u003c\/p\u003e","brand":"Uni-Trend US","offers":[{"title":"181100300069X","offer_id":53265475993824,"sku":"181100300069X","price":2879.2,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/MSO3000X_1_sq_6dc04cea-6485-4657-92dd-d3112753ed24.jpg?v=1782858083"},{"product_id":"ut-p31-100-mhz-10-1-100-1-differential-oscilloscope-probe","title":"UT-P31 100 MHz 10:1\/100:1 Differential Oscilloscope Probe","description":"\u003ch1\u003e100 MHz differential oscilloscope probe (10:1\/100:1 attenuation) for safely measuring floating voltages across motor drives, power converters and bridge circuits.\u003c\/h1\u003e\n\u003cp\u003e\u003cstrong\u003eCompatible with UNI-T oscilloscopes and most oscilloscopes with BNC inputs.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e100MHz Bandwidth\u003c\/strong\u003e — Captures signal content up to 100MHz for accurate waveform measurement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e10:1\/100:1 Attenuation\u003c\/strong\u003e — Divides the input signal for measuring higher-voltage circuits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e1500Vpp Maximum Input Voltage\u003c\/strong\u003e — Rated input voltage for safe operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard BNC Connection\u003c\/strong\u003e — Compatible with UNI-T oscilloscopes and most oscilloscopes with BNC inputs.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCAT Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCAT III\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e69 × 26 × 165 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBandwidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe Attenuation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100:1, 1000:1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe Max Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1500Vpp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRise Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.5ns\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Capacitance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 pF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Impedance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 MΩ \/ 1 pF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 °C - 50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDifferential Input Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1500Vpp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommon Mode Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5kVrms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCMRR\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 80 dB @ 60 Hz, \u0026gt; 60 dB @ 100 Hz, \u0026gt; 50 dB @ 1 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Uni-Trend US","offers":[{"title":"Default Title","offer_id":53265476026592,"sku":"190500300015","price":699.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/UT-P31_1_sq.jpg?v=1782858082"},{"product_id":"mso5034hd-350-mhz-4ch-12-bit-mixed-signal-oscilloscope","title":"MSO5034HD 350 MHz 4Ch 12-Bit Mixed Signal Oscilloscope","description":"\u003ch4\u003eOverview\u003c\/h4\u003e\n\u003ch1\u003eThe MSO5034HD is a 350 MHz, 4-channel mixed signal oscilloscope built on UNI-T’s R12™ native 12-bit ADC architecture, with a 5 GSa\/s real-time sample rate (interleave mode), 500 Mpts standard memory depth, and a calculated rise time of ≤1.00 ns.\u003c\/h1\u003e\n\u003cp\u003eThe 12-bit resolution holds at the full 350 MHz bandwidth with no ERES averaging step or sample-rate trade-off, and Ultra Phosphor 3.0 acquisition delivers up to 800,000 wfms\/s standard — 1,500,000 wfms\/s in Sequential Mode. Sixteen digital channels are available with the UT-M15 logic probe pod, on a 10.1-inch capacitive multi-touch display.\u003c\/p\u003e\n\u003cp\u003eFor embedded prototyping with high-resolution requirements, four-channel mixed-signal debug in dedicated R\u0026amp;D groups, and lab benches that need real 12-bit acquisition without stepping up to a 1 GHz instrument, the MSO5034HD is the family-entry door into the HD-scope tier above MSO3000HD — double the sample rate (5 GSa\/s vs 2.5 GSa\/s), the same 500 Mpts memory, and the same nine-instrument workhorse platform, on a 10.1-inch capacitive multi-touch display.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e350 MHz Bandwidth, 4 Channels\u003c\/strong\u003e — 4-channel analog capture with 5 GSa\/s sample rate and 12-bit native vertical resolution, scaling to 16-bit with ERES.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e500 Mpts Memory Depth\u003c\/strong\u003e — Deep memory for extended captures without sample-rate trade-off; navigation and search across the full memory window.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e800,000 wfms\/s Standard, 1.5 M in Sequential Mode\u003c\/strong\u003e — Ultra Phosphor 3.0 intensity-graded display with 256 grayscale levels for rare-event hunting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eR12™ Native 12-Bit ADC\u003c\/strong\u003e — 4,096 vertical levels at full bandwidth, sixteen times the resolution of a conventional 8-bit oscilloscope.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSix Protocols Standard, Nine Optional\u003c\/strong\u003e — RS-232\/UART, I²C, SPI, CAN, LIN included; CAN-FD, CAN-XL, FlexRay, SENT, Audio, MIL-STD-1553B, ARINC 429, Manchester, 1-Wire, and I3C optional.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuilt-in 2.5 GHz Spectrum Analyzer\u003c\/strong\u003e — Enhanced FFT up to 4 Mpts, four traces and four detections, waterfall display.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptional 50 MHz Dual-Channel AWG\u003c\/strong\u003e — Built-in arbitrary waveform generator pairs with the optional Bode plot analyzer for closed-loop frequency-response measurement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptional Power Analysis Suite\u003c\/strong\u003e — Switching loss, harmonic analysis, SOA, R\u003csub\u003eDS(on)\u003c\/sub\u003e, modulation, slew rate, ripple analysis, and more.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e16 Digital Channels with UT-M15\u003c\/strong\u003e — Add the UT-M15 logic probe pod for time-correlated mixed-signal debug.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e56 Automated Measurements with Histogram and Trend\u003c\/strong\u003e — 27 measurements simultaneously displayed; 39-item single-channel parameter snapshot.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e10.1-Inch Capacitive Touchscreen\u003c\/strong\u003e — 1280×800 HD multi-touch with gesture support; full-SCPI WebServer for browser-based remote control.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eDetailed Features\u003c\/h2\u003e\n\u003ch3\u003eR12™ — Native 12-Bit at Full Bandwidth\u003c\/h3\u003e\n\u003cp\u003eR12™ is UNI-T’s native 12-bit ADC architecture: 4,096 vertical quantization levels — sixteen times the resolution of a conventional 8-bit oscilloscope — held at the full 350 MHz bandwidth and 5 GSa\/s sample rate, with no ERES averaging step and no sample-rate trade-off to get there. ERES (enhanced resolution) extends effective vertical resolution up to 16-bit when bandwidth headroom is available, but the baseline 12-bit performance is the front-end’s native characteristic, not a software boost. For low-amplitude signal work — switching ripple riding on a busy DC rail, sensor-bridge outputs into a noisy ADC, jitter analysis on a clock line — the difference between 8-bit quantization steps showing through the measurement and 12-bit fidelity disappearing them is the difference between a usable capture and a noisy one.\u003c\/p\u003e\n\u003ch3\u003eUltra Phosphor 3.0 — 800,000 wfms\/s, 1.5 M in Sequential Mode\u003c\/h3\u003e\n\u003cp\u003eUltra Phosphor 3.0 is UNI-T’s third-generation waveform-mapping architecture, combining parallel FPGA acquisition with 256-level grayscale intensity grading. Standard waveform capture rate is up to 800,000 wfms\/s — high enough to surface intermittent timing anomalies on a long capture window without missing them between screen redraws. In Sequential Mode — the segmented-memory acquisition mode that conditions captures on a trigger event — capture rate climbs to 1,500,000 wfms\/s, and the scope holds up to 400,000 frames of uninterrupted hardware real-time recording for post-capture replay and analysis. Rare-event hunting on a live system stops being a watch-and-wait exercise and starts being an analysis-after-capture exercise.\u003c\/p\u003e\n\u003ch3\u003eNine Instruments in One — The HD Workhorse Platform\u003c\/h3\u003e\n\u003cp\u003eThe MSO5000HD platform integrates nine instrument functions into one bench unit: digital storage oscilloscope, 16-channel logic analyzer (with the optional UT-M15 probe pod), 50 MHz dual-channel function and arbitrary waveform generator (optional), 2.5 GHz spectrum analyzer, 4-digit digital voltmeter, 7-digit hardware frequency counter, multi-protocol serial-bus analyzer, Bode plot analyzer (optional, paired with the AWG for closed-loop sweep), and power-electronics analyzer (optional). For small-lab consolidation and education-track lab benches, the integration replaces three to five separate instruments with one instrument footprint, one calibration chain, and one operator-training surface.\u003c\/p\u003e\n\u003ch3\u003eDeep Memory — 500 Mpts\u003c\/h3\u003e\n\u003cp\u003e500 Mpts of acquisition memory standard, with adjustable depths from Auto (5 Mpts) through 25 kpts, 250 kpts, 500 kpts, 5 Mpts, 50 Mpts, 100 Mpts, and 500 Mpts. Deep memory matters when the acquisition window is long — minutes-long captures looking for an intermittent fault, multi-frame protocol traces across a power-on sequence, or extended ripple analysis across a load-step transient — because the sample rate stays at 5 GSa\/s for far longer than a shallow-memory scope before forcing a sample-rate trade-off. Combined with the navigation-and-search function (event, time, and marker navigation modes), the deep memory is searchable: zoom into a specific glitch in a 500 Mpt capture without scrolling through the rest.\u003c\/p\u003e\n\u003ch3\u003e16 Digital Channels with the UT-M15 Probe Pod (Optional)\u003c\/h3\u003e\n\u003cp\u003eMixed-signal capability is hardware-standard in the MSO5000HD chassis — the 16-digital-channel logic-analyzer front end is built in. Adding the digital channels requires the optional UT-M15 logic probe pod, which provides separate high 8-bit and low 8-bit connections and connects directly to 8×2 square pins (2.54 mm) for fast attachment to development boards. Maximum digital sample rate is 1.25 GSa\/s with a minimum detectable pulse width of 800 ps, and threshold selection covers TTL, 5.0 V\/3.3 V\/2.5 V\/1.8 V CMOS, ECL, PECL, LVDS, and a custom level — covering essentially every common digital interface voltage on modern hardware. Digital and analog channels share the same time base, the same trigger system, and the same display, so a falling SPI clock edge and the analog-domain crosstalk it causes show up in the same frame.\u003c\/p\u003e\n\u003ch3\u003e15 Protocol Decoders — 6 Standard, 9 Optional\u003c\/h3\u003e\n\u003cp\u003eSix protocols decode standard with the MSO5000HD: RS-232\/422\/485\/UART, I²C, SPI, CAN, and LIN. Nine additional protocols are available as separately licensed options: CAN-FD, CAN-XL, FlexRay, SENT, Audio (I²S\/LJ\/RJ\/TDM), MIL-STD-1553B, ARINC 429, Manchester, 1-Wire, and I3C. The decoder runs on dedicated decode hardware, not a software post-processing path, so decode results display in real time during acquisition rather than after-the-fact on saved data — the difference between “debug a protocol stack interactively” and “capture, save, transfer, open in a separate tool, decode.” Trigger-and-decode operates pause-and-record modes for both interactive bring-up and unattended logging, and the event list plus search function lets you jump to a specific framed event across a 500 Mpt capture.\u003c\/p\u003e\n\u003ch3\u003eBuilt-In Spectrum Analyzer — 4 Mpts FFT to 2.5 GHz\u003c\/h3\u003e\n\u003cp\u003eThe MSO5000HD’s built-in spectrum analyzer leverages the 5 GSa\/s sample rate for a 0–2.5 GHz frequency range — useful for characterizing wideband signals, identifying spurious emissions, and verifying clock harmonics at frequencies beyond what 2.5 GSa\/s instruments can analyze. Enhanced FFT supports up to 4 Mpts with 4-channel parallel signal analysis, four traces and four detections, auto\/manual\/threshold marker types, marker point lists, and a waterfall-curve display mode for time-evolving spectra. For pre-compliance EMI screening, switching-supply noise hunting, and clock-quality verification, the integrated spectrum analyzer means one instrument covers both time-domain and frequency-domain measurement needs.\u003c\/p\u003e\n\u003ch3\u003ePower Analysis — Optional Multi-Class Suite\u003c\/h3\u003e\n\u003cp\u003eThe optional power-analysis package adds nine classes of power-electronics measurement to the MSO5000HD: power quality, surge current, safe operating area (SOA), harmonic analysis, R\u003csub\u003eDS(on)\u003c\/sub\u003e measurement, modulation analysis, switching-loss analysis, slew rate, and ripple analysis — with transient-response and power-efficiency measurements added in firmware updates. For early-stage power-converter design, the package replaces a separate power-analyzer instrument: the same scope that captures the gate-drive waveform calculates the switching loss across the cycle, and the same FFT mode that screens for spurs computes the harmonic spectrum on the AC input. Connect a voltage probe and a current probe, select the analysis type, and the calculations run on-instrument — no post-processing workflow, no separate software tool.\u003c\/p\u003e\n\u003ch3\u003e56 Automated Measurements with Histogram and Trend Statistics\u003c\/h3\u003e\n\u003cp\u003e56 automated measurement types cover voltage, time, frequency-domain, and area-under-curve calculations — with up to 27 measurements displayed simultaneously on screen and a 39-item single-channel parameter snapshot for production-style documentation. Histogram and trend-line displays show measurement statistics over time, useful for signal-integrity work where the parameter distribution matters as much as a single instantaneous value. The new top-and-bottom amplitude calculation strategy and the burst-region measurement function add capability for non-stationary signals where the measurement window has to be localized to a specific event rather than averaged across the full capture.\u003c\/p\u003e\n\u003ch3\u003eTiming Analyzer — Bus Timing Conformance Testing\u003c\/h3\u003e\n\u003cp\u003eThe timing analyzer function performs conformance-grade timing measurements on serial bus signals: pulse width, amplitude, edge characteristics, setup time, and hold time on I²C, SPI, CAN, and I²S buses. For consumer-electronics manufacturing — mobile phones, smart wearables, home appliances, multimedia audio-video equipment, and automotive electronics — bus-timing consistency is the difference between a board that passes audit and one that fails customer qualification. The MSO5000HD generates exportable conformance test reports, turning the scope into a documentation tool for design verification and test-lab compliance work.\u003c\/p\u003e\n\u003ch3\u003e10.1-Inch Touch UI, WebServer, and SCPI Automation\u003c\/h3\u003e\n\u003cp\u003eA 10.1-inch 1280×800 capacitive multi-touch display anchors the front-panel experience — touch, drag, pinch-to-zoom, and rectangle-drawing gestures for common waveform operations — while preserving the traditional knob-and-key controls that bench engineers want for fine adjustment. Mouse and keyboard are supported as additional input methods. For automation, the built-in WebServer provides browser-based instrument control over the network — SCPI commands, waveform export, and online user-manual access — from PC or mobile devices, and full SCPI compliance over LAN or USB Device enables programmatic control from LabVIEW, Python, or any SCPI-aware test framework. UNI-T’s free instrument manager runs on the PC side for graphical control without writing custom automation code.\u003c\/p\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003ch3\u003eR\u0026amp;D and Embedded Validation\u003c\/h3\u003e\n\u003cp\u003eFor R\u0026amp;D validation on multi-rail digital boards, the MSO5034HD’s 12-bit native resolution at 350 MHz keeps low-amplitude signal artifacts — switching ripple, crosstalk, return-path noise — visible at scale during overnight regression captures, with 500 Mpts memory enabling deep zoom-and-search across long capture windows.\u003c\/p\u003e\n\u003ch3\u003ePower Electronics Design and Validation\u003c\/h3\u003e\n\u003cp\u003eFor power-electronics design at moderate switching frequencies, the MSO5034HD pairs four-channel acquisition with optional power-analysis software for switching-loss, efficiency, and ripple measurement on switch-mode and battery-management designs — same instrument, no separate power analyzer required.\u003c\/p\u003e\n\u003ch3\u003eTest Laboratory and Consultancy Work\u003c\/h3\u003e\n\u003cp\u003eFor internal test labs documenting compliance and pre-compliance characterization, the MSO5034HD’s 56 automated measurements with histogram and trend statistics, paired with hardware-accelerated template testing, generate the kind of pass\/fail evidence reports that internal-audit and external-customer test packages require.\u003c\/p\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAnalog Bandwidth (50 Ω, −3 dB)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e350 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAnalog Bandwidth (1 MΩ, −3 dB)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e350 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChannels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 Analog + 16 Digital (with optional UT-M15 probe pod)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReal-Time Sample Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 GSa\/s (interleave mode) \/ 2.5 GSa\/s (non-interleave mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDigital Channel Sample Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.25 GSa\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVertical Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12-bit native (up to 16-bit with ERES)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMemory Depth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 Mpts maximum per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCapture Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800,000 wfms\/s standard; 1,500,000 wfms\/s in Sequential Mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCalculated Rise Time (10–90%, Typ.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤1.00 ns\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBackground Noise (full BW, Typ.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e75 µVrms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10.1 inches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1280 × 800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTouch Screen\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCapacitive multi-touch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSequential Sampling\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMaximum 400,000 frames; minimum two trigger intervals \u0026lt; 700 ns\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHardware Real-Time Waveform Recording\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400,000 frames\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrigger Modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 types: edge, pulse width, video, ramp, runt, over-amplitude, delay, timeout, duration, setup \u0026amp; hold, Nth edge, code pattern; Zone trigger\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtocol Triggering and Decoding\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 protocols total. \u003cstrong\u003eStandard:\u003c\/strong\u003e RS-232\/422\/485\/UART, I²C, SPI, CAN, LIN. \u003cstrong\u003eOptional:\u003c\/strong\u003e CAN-FD, CAN-XL, FlexRay, SENT, Audio, MIL-STD-1553B, ARINC 429, Manchester, 1-Wire, I3C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSpectrum Analyzer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0–2.5 GHz, enhanced FFT up to 4 Mpts, 4-channel parallel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBuilt-in AWG (Optional)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 MHz equivalent, dual-channel, 312.5 MSa\/s, 16-bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBode Plot Analyzer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOptional — frequency response, loop stability, filter, amplifier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Analyzer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOptional — switching loss, harmonics, ripple, slew rate, R\u003csub\u003eDS(on)\u003c\/sub\u003e, SOA, modulation, transient response, power efficiency\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAutomated Measurements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e56 types; up to 27 simultaneous; histogram and trend display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Input Voltage (1 MΩ)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400 V (DC + AC\u003csub\u003eVpk\u003c\/sub\u003e); 135 V\u003csub\u003eRMS\u003c\/sub\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Input Voltage (50 Ω)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 V\u003csub\u003eRMS\u003c\/sub\u003e max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnectivity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSB Host\/Device, LAN, EXT Trig, AUX Out (Trig Out \/ Pass-Fail \/ DVM), Gen Out, HDMI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRemote Control\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSCPI over LAN\/USB; built-in WebServer (browser, PC + mobile); UNI-T Instrument Manager\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRoHS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eDownloads\u003c\/h4\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cbr\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/MSO5000HD_Series_-_Data_Sheet.pdf\" title=\"MSO5000 Series Datasheet\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/pdf-icon-63x63_480x480.png\" style=\"float: left;\" alt=\"PDF\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/850009-i.pdf\" target=\"_blank\"\u003e\u003cbr\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/MSO5000HD_Series_-_Data_Sheet.pdf\"\u003eUNI-T MSO5000 Series Datasheet\u003c\/a\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cbr\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/MSO5000HD_Series_User_Manual.pdf\" title=\"UNI-T MSO5000 Series Users Manual\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/pdf-icon-63x63_480x480.png\" style=\"float: left;\" alt=\"PDF\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/850009-i.pdf\" target=\"_blank\"\u003e\u003cbr\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/MSO5000HD_Series_User_Manual.pdf\" title=\"UNI-T MSO5000 Series Users Manual\" rel=\"noopener\" target=\"_blank\"\u003eUNI-T MSO5000 Series Users Manual\u003c\/a\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eOptions \u0026amp; Accessories\u003c\/h4\u003e\n\u003ch3\u003eIncluded in Box\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePower cord (region-specific)\u003c\/li\u003e\n\u003cli\u003eUSB cable\u003c\/li\u003e\n\u003cli\u003eQuick start guide\u003c\/li\u003e\n\u003cli\u003eCalibration certificate\u003c\/li\u003e\n\u003cli\u003eProbe set: passive 10:1 voltage probes (4×) sized for the bandwidth of the analog front end\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eRecommended Add-Ons\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUT-M15 Logic Probe Pod — adds 16 digital channels with high\/low 8-bit connectors and direct 8×2 square-pin attachment.\u003c\/li\u003e\n\u003cli\u003eActive probes — for 50 Ω high-bandwidth signal-integrity work where a passive 10x probe limits visibility.\u003c\/li\u003e\n\u003cli\u003eCurrent probe(s) — for power-electronics work paired with the optional power-analysis suite; voltage and current probe simultaneously for switching-loss measurement.\u003c\/li\u003e\n\u003cli\u003eAWG license — activates the dual-channel 50 MHz arbitrary waveform generator hardware in the chassis.\u003c\/li\u003e\n\u003cli\u003eBode plot license — pairs with the AWG for closed-loop frequency-response sweep on amplifiers, filters, and power-supply control loops.\u003c\/li\u003e\n\u003cli\u003ePower analysis license — activates the multi-class power-electronics measurement suite.\u003c\/li\u003e\n\u003cli\u003eProtocol decoder licenses — CAN-FD, CAN-XL, FlexRay, SENT, Audio, MIL-STD-1553B, ARINC 429, Manchester, 1-Wire, I3C, available individually.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSoftware Options\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMSO5000HD-1WIRE — 1-Wire Serial Bus Trigger and Analysis Option\u003c\/li\u003e\n\u003cli\u003eMSO5000HD-ARINC429 — Aerospace ARINC429 Serial Bus Trigger and Analysis\u003c\/li\u003e\n\u003cli\u003eMSO5000HD-AUDIO — Audio Serial Bus Trigger and Analysis\u003c\/li\u003e\n\u003cli\u003eMSO5000HD-AUTO — Automotive Serial Bus Trigger and Analysis Option\u003c\/li\u003e\n\u003cli\u003eMSO5000HD-AWG — 50 MHz 2Ch Arbitrary Waveform Generator with Bode Plot\u003c\/li\u003e\n\u003cli\u003eMSO5000HD-BND — Complete Serial Analysis Bundle\u003c\/li\u003e\n\u003cli\u003eMSO5000HD-BW3M5T1G — 1GHz bandwidth upgrade\u003c\/li\u003e\n\u003cli\u003eMSO5000HD-BW5MT1G — 1GHz bandwidth upgrade\u003c\/li\u003e\n\u003cli\u003eMSO5000HD-CANFD — Automotive CAN-FD Serial Bus Trigger and Analysis\u003c\/li\u003e\n\u003cli\u003eMSO5000HD-CANXL — Automotive CAN-XL Serial Bus Trigger and Analysis\u003c\/li\u003e\n\u003cli\u003eMSO5000HD-FLEX — Automotive FlexRay Serial Bus Trigger and Analysis\u003c\/li\u003e\n\u003cli\u003eMSO5000HD-I3C — Embedded Systems I3C Serial Bus Trigger and Analysis\u003c\/li\u003e\n\u003cli\u003eMSO5000HD-MANCH — Manchester Serial Bus Trigger and Analysis Option\u003c\/li\u003e\n\u003cli\u003eMSO5000HD-MIL1553 — MIL-STD-1553 Serial Bus Trigger and Analysis Option\u003c\/li\u003e\n\u003cli\u003eMSO5000HD-PWR — Advanced Power Analysis\u003c\/li\u003e\n\u003cli\u003eMSO5000HD-SENT — Automotive SENT Serial Bus Trigger and Analysis\u003c\/li\u003e\n\u003cli\u003eMSO5000HD-TIMING — Advanced Timing Analysis\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4\u003eFAQ's\u003c\/h4\u003e\n\u003ch3\u003eWhat protocols are included with the MSO5000HD as standard?\u003c\/h3\u003e\n\u003cp\u003eRS-232\/422\/485, UART, I²C, SPI, CAN, and LIN are decoded standard with no additional license required. CAN-FD, CAN-XL, FlexRay, SENT, Audio (I²S\/LJ\/RJ\/TDM), MIL-STD-1553B, ARINC 429, Manchester, 1-Wire, and I3C are available as separately licensed options — activated on the same instrument with no firmware upgrade or reflash required.\u003c\/p\u003e\n\u003ch3\u003eWhat is the practical advantage of 12-bit native resolution over 8-bit?\u003c\/h3\u003e\n\u003cp\u003eA 12-bit ADC provides 4,096 vertical quantization levels compared to 256 for an 8-bit scope — sixteen times the resolution. In low-amplitude work (switching ripple riding on a DC rail, sensor outputs from a strain gauge, jitter on a clock line, or any signal where the amplitude of interest is much smaller than the channel’s full-scale range), 8-bit quantization steps show up as visible stair-stepping in the captured waveform. 12-bit acquisition keeps those steps below the front-end’s noise floor, so what you’re looking at on screen is the signal, not the digitization grid.\u003c\/p\u003e\n\u003ch3\u003eHow do I add 16 digital channels for mixed-signal work?\u003c\/h3\u003e\n\u003cp\u003eThe 16-digital-channel logic-analyzer front end is built into every MSO5000HD chassis as hardware-standard. To use it, add the optional UT-M15 logic probe pod, which provides separate high 8-bit and low 8-bit pin connections and attaches directly to standard 2.54 mm 8×2 square-pin headers on development boards. Maximum digital sample rate is 1.25 GSa\/s with an 800 ps minimum detectable pulse width.\u003c\/p\u003e\n\u003ch3\u003eWhat is the difference between Ultra Phosphor 3.0’s 800,000 wfms\/s standard rate and the 1,500,000 wfms\/s sequential-mode rate?\u003c\/h3\u003e\n\u003cp\u003eThe 800,000 wfms\/s rate is the continuous waveform-capture rate during normal acquisition — the rate at which the scope acquires, processes, and displays new waveforms back-to-back during live operation. The 1,500,000 wfms\/s sequential-mode rate applies in segmented-memory acquisition where the scope captures only a short window around each trigger event, then re-arms quickly for the next trigger; this maximizes capture density when chasing intermittent events at the cost of dead time between captures. In practical terms: continuous 800K for general-purpose acquisition, sequential 1.5M for rare-event hunting on a triggered signal.\u003c\/p\u003e\n\u003ch3\u003eIs the AWG (arbitrary waveform generator) included or optional?\u003c\/h3\u003e\n\u003cp\u003eThe AWG hardware is built into every MSO5000HD chassis as hardware-standard, but activation requires the AWG software license. Once activated, it provides dual-channel 50 MHz output with sine, square, pulse, ramp, arbitrary, noise, and DC waveforms; AM, FM, ASK, FSK, and sweep modulation; and the ability to load on-screen captured waveforms back to the Gen output for replay-style stimulus testing. The optional Bode plot analyzer pairs with the AWG for closed-loop frequency-response measurement.\u003c\/p\u003e\n\u003ch3\u003eCan I control the MSO5000HD remotely without installing local software?\u003c\/h3\u003e\n\u003cp\u003eYes. The built-in WebServer provides full instrument control through any standard web browser on a PC, tablet, or mobile device on the same network — no client install, no driver download. Common operations (waveform capture, screenshot, parameter readback, settings changes, file export) work directly through the browser. For programmatic control, the same interface accepts SCPI commands over LAN or USB, compatible with LabVIEW, Python, MATLAB, and any SCPI-aware automation framework. UNI-T also provides a free instrument-manager application for users who prefer a graphical desktop client.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Uni-Trend US","offers":[{"title":"Default Title","offer_id":53265476059360,"sku":"181100300116X","price":3144.15,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/MSO5104_1.png?v=1782858082"},{"product_id":"mso2104x-100-mhz-4ch-mixed-signal-oscilloscope","title":"MSO2104X 100 MHz 4Ch Mixed Signal Oscilloscope","description":"\u003ch1\u003eThe MSO2104X is a 100 MHz, four-channel mixed-signal oscilloscope.\u003c\/h1\u003e\n\u003cp\u003eWith 5 GSa\/s real-time sample rate, 100 Mpts of memory depth, 16 logic-analyzer channels (with the optional UT-M15 probe pod), and Ultra Phosphor 3.0 waveform mapping at up to 2,000,000 wfms\/s in Sequential Mode, the MSO2104X integrates nine bench instruments into one 10.1-inch capacitive multi-touch footprint — oscilloscope, logic analyzer, AWG, spectrum analyzer, DVM, frequency counter, protocol analyzer, Bode plot, and power analyzer.\u003c\/p\u003e\n\u003cp\u003eFor embedded prototyping, four-channel mixed-signal debug at the entry-tier price point, and curriculum-grade lab benches running through analog-and-digital fundamentals, the MSO2104X is the entry SKU into the MSO2000X line — opening into a real nine-instrument bench at 5 GSa\/s sample rate, 100 Mpts memory, and the same 10.1-inch capacitive touchscreen that the higher-bandwidth siblings carry. For embedded-systems teams who would otherwise stack a basic 100 MHz scope alongside a separate AWG, spectrum analyzer, and protocol decoder, the integration replaces three or four bench instruments with one footprint.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e100 MHz Bandwidth, 4 Analog Channels\u003c\/strong\u003e — Four-channel acquisition at up to 100 MHz with 5 GSa\/s sample rate (interleave) and calculated rise time of ≤3.50 ns.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e100 Mpts Memory Depth\u003c\/strong\u003e — Standard deep memory across all four channels for long capture windows without sample-rate trade.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUltra Phosphor 3.0 Display Technology\u003c\/strong\u003e — 256-level grayscale persistence with parallel FPGA mapping; up to 500,000 wfms\/s standard, 2,000,000 wfms\/s in Sequential Mode.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNine Instruments in One\u003c\/strong\u003e — Oscilloscope, 16-channel logic analyzer (optional probe), AWG (optional), 2.5 GHz spectrum analyzer, 4-digit DVM, 7-digit hardware frequency counter, protocol analyzer, Bode plot (with AWG), and power analyzer (optional).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard Protocol Decoding\u003c\/strong\u003e — RS-232\/UART, I²C, and SPI included as standard.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptional Protocols\u003c\/strong\u003e — CAN, CAN-FD, LIN, FlexRay, SENT, and Audio (I²S\/LJ\/RJ\/TDM) available as software licenses.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e16 Digital Channels (Optional)\u003c\/strong\u003e — Add mixed-signal capability with the UT-M15 logic probe pod; 1.25 GSa\/s digital sample rate, 800 ps minimum detectable pulse width.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptional 50 MHz Dual-Channel AWG\u003c\/strong\u003e — 16-bit, 250 MSa\/s arbitrary waveform generator with 200 built-in waveforms; Bode plot analyzer included with the AWG package.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eZone Triggering\u003c\/strong\u003e — Rectangle-drawn trigger conditions with Must Intersect \/ Must Not Intersect logic.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e56 Automated Measurements\u003c\/strong\u003e — Voltage, time, frequency, and statistical measurements with histogram and trend statistics; up to 27 displayed simultaneously.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e10.1-Inch Capacitive Multi-Touch\u003c\/strong\u003e — 1280×800 HD display with multi-window layout, gesture control, and HDMI output.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCPI and WebServer Remote Control\u003c\/strong\u003e — USB 3.0, LAN (VXI-11), and built-in browser-based control from PC or mobile.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFree Firmware Updates and No-Expiration License Unlocks\u003c\/strong\u003e — Firmware updates are free over the product’s lifetime; license unlocks for optional packages have no expiration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eDetailed Features\u003c\/h2\u003e\n\u003ch3\u003eNine Instruments in One\u003c\/h3\u003e\n\u003cp\u003eThe MSO2000X platform integrates nine instrument functions into one bench unit: digital storage oscilloscope, 16-channel logic analyzer (with the optional UT-M15 probe pod), 50 MHz dual-channel function and arbitrary waveform generator (optional), 2.5 GHz spectrum analyzer (FFT up to 4 Mpts), 4-digit digital voltmeter, 7-digit hardware frequency counter, multi-protocol serial-bus analyzer, Bode plot analyzer (optional, paired with the AWG for closed-loop sweep), and power-electronics analyzer (optional). For teaching-lab and embedded-prototyping benches where rack space and budget cap the instrument count, the integration is the differentiator: one instrument trains one operator workflow instead of four, and one calibration cycle covers the full feature set.\u003c\/p\u003e\n\u003ch3\u003eHigh-Speed Acquisition — 5 GSa\/s, 100 Mpts\u003c\/h3\u003e\n\u003cp\u003eThe 5 GSa\/s real-time sample rate (interleave mode) and 100 Mpts of acquisition memory hold full waveform fidelity across the 100 MHz analog bandwidth. Standard capture rate runs up to 500,000 wfms\/s; in Sequential Mode — the segmented-memory acquisition mode that conditions captures on a trigger event — capture rate climbs to 2,000,000 wfms\/s, holding up to 125,000 frames of uninterrupted hardware real-time waveform recording for post-capture replay and analysis.\u003c\/p\u003e\n\u003cp\u003eERES (enhanced resolution) extends effective vertical resolution from the 8-bit native ADC up to 12-bit when bandwidth headroom is available — useful for low-amplitude work where quantization noise would otherwise obscure detail on switching ripple, sensor outputs, or jitter analysis.\u003c\/p\u003e\n\u003ch3\u003eUltra Phosphor 3.0 — 256-Level Grayscale Persistence\u003c\/h3\u003e\n\u003cp\u003eUltra Phosphor 3.0 is UNI-T’s third-generation waveform-mapping architecture, combining parallel FPGA acquisition with 256-level grayscale intensity grading. Throughput is five to ten times higher than the previous-generation pipeline, and acquisition dead time drops below 1 µs — the scope captures 1.17 ns fast-edge signals at 2,000,000 events per second in Sequential Mode without missing the rare-event bracket between redraws. The 256-level intensity grading shows signal frequency-of-occurrence directly: frequent waveforms appear brighter, infrequent ones dimmer, making it intuitive to distinguish normal behavior from intermittent faults during long bench captures.\u003c\/p\u003e\n\u003ch3\u003eBuilt-In Spectrum Analyzer — FFT to 4 Mpts\u003c\/h3\u003e\n\u003cp\u003eThe standard enhanced-FFT spectrum analyzer covers 0 Hz to 2.5 GHz with up to 4 Mpts of FFT length, four-channel signal analysis, four trace types (Normal, Average, Max Hold, Min Hold), and four detection modes. Marker functions cover Auto, Manual, and Threshold with a marker-point list, plus a waterfall display for tracking spectral activity over time. Use it to identify harmonics, characterize EMI signatures during pre-compliance sweeps, verify clock-signal purity on embedded designs, or analyze modulated signals — without paying for a separate spectrum analyzer.\u003c\/p\u003e\n\u003ch3\u003eProtocol Analysis — 9 Bus Types Across Four Domains\u003c\/h3\u003e\n\u003cp\u003eThe MSO2000X covers nine protocol types across four bus domains: computer serial (RS-232\/UART, I²C, SPI — standard), automotive serial (CAN, CAN-FD, LIN, FlexRay — optional), automotive sensor (SENT — optional), and audio (I²S, Left-Justified, Right-Justified, TDM — optional). Triggering and decoding are integrated: trigger on a frame error, an identifier match, a CRC failure, or a missing-ack condition, and the decode displays inline with the captured waveform. Up to four simultaneous decodes plus parallel-bus decoding (up to 18 bits, mixed analog and digital channels) cover most embedded-systems and automotive bus-validation workflows in one instrument.\u003c\/p\u003e\n\u003ch3\u003e50 MHz Dual-Channel AWG with Bode Plot (Optional)\u003c\/h3\u003e\n\u003cp\u003eThe optional MSO2000X-AWG package adds a 50 MHz dual-channel function and arbitrary waveform generator with 16-bit vertical resolution and 250 MSa\/s sample rate, plus the Bode plot analyzer for frequency-response, loop-stability, filter, and amplifier characterization. Built-in waveforms include sine, square, pulse, ramp, arbitrary, noise, and DC, with 200 standard arbitrary waveforms (Sinc, ExpRise, ExpFall, Cardiac, Gauss, Lorentz, HaverSine, and others). AM, FM, ASK, FSK, and sweep modulation are supported, and on-screen oscilloscope captures can be loaded directly into the AWG for stimulus-response replay.\u003c\/p\u003e\n\u003ch3\u003ePower Analysis (Optional) — Five Measurement Types\u003c\/h3\u003e\n\u003cp\u003eFor curriculum coverage of power-quality and switching-mode-supply fundamentals, the optional power-analysis package adds power quality, harmonic analysis, surge-current characterization, ripple analysis, and loop analysis to the existing four-channel acquisition path. The same scope used for protocol decode and AWG-driven stimulus also computes harmonic distortion on the AC line and characterizes switching loss across a converter cycle — useful for power-electronics introductions and senior-design coursework where a separate power analyzer is not in the budget.\u003c\/p\u003e\n\u003ch3\u003eZone Triggering — Rectangle-Drawn Trigger Conditions\u003c\/h3\u003e\n\u003cp\u003eZone triggering isolates an occasional anomaly by trigger condition rather than waveform stability. Draw a rectangle on the display, set Must Intersect or Must Not Intersect, and the scope triggers when the waveform meets the spatial condition — two zones supported, sourced from any of CH1 through CH4. Combined with the eleven trigger types (edge, pulse width, ramp, runt pulse, over-amplitude pulse, delay, timeout, duration, setup \u0026amp; hold, Nth edge, code pattern), the zone trigger turns rare-event hunting into a defined acquisition condition rather than a wait-and-watch exercise.\u003c\/p\u003e\n\u003ch3\u003e56 Automated Measurements with Histogram and Trend Statistics\u003c\/h3\u003e\n\u003cp\u003eThe MSO2000X provides 56 automated measurement parameters on the analog channels — voltage, time, frequency, statistical, and burst measurements — with up to 27 measurements displayed simultaneously and per-channel parameter snapshots showing 39 single-channel measurements at once. Measurement statistics include mean, maximum, minimum, standard deviation, count, tendency chart, and bar chart (histogram) views. The histogram surfaces parameter distribution visually; the tendency chart shows parameter drift over time — useful for jitter analysis, long-capture characterization, and pass\/fail evidence reports.\u003c\/p\u003e\n\u003ch3\u003eFast Fuzzy Autoset — Sub-Second All-Channel Setup\u003c\/h3\u003e\n\u003cp\u003eThe MSO2000X uses a fuzzy-logic autoset algorithm built around the 7-digit hardware frequency counter and multi-channel parallel processing. All-channel autoset completes in under 1.5 seconds; single-channel autoset completes in under 1 second — useful on production-line spot-check work and education-track lab benches with frequent setup changes.\u003c\/p\u003e\n\u003ch3\u003e10.1-Inch Capacitive Multi-Touch UI\u003c\/h3\u003e\n\u003cp\u003eThe 10.1-inch 1280×800 HD capacitive multi-touch display supports the standard touch gestures (click, slide, zoom, edit, drag) for direct waveform manipulation, plus rectangle-draw for zone triggering. Multi-window layout lets multiple display panels (waveform, FFT, decode list, measurement table) be dragged and resized independently. Traditional knob-and-key controls remain for engineers who prefer them, and external mouse and keyboard input is supported via USB. HDMI output mirrors the display to an external monitor or projector — useful for instructor-led demonstrations and engineering team reviews.\u003c\/p\u003e\n\u003ch3\u003eConnectivity, SCPI, and WebServer Remote Control\u003c\/h3\u003e\n\u003cp\u003eUSB 3.0 Host (one front, two rear), USB 3.0 Device (rear), LAN (10\/100\/1000 BASE-T, VXI-11), HDMI display output, two front-panel Gen Out connectors (paired with the optional AWG), 10 MHz reference In\/Out, and AUX Out (Trig Out \/ Pass-Fail \/ DVM). The instrument supports the full SCPI command set, and the built-in WebServer provides browser-based remote control from PC or mobile.\u003c\/p\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003ch3\u003eFor R\u0026amp;D Engineers\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFor embedded-systems prototyping at 100 MHz, the MSO2104X covers ARM Cortex-M and RISC-V microcontroller debug, four-channel timing-correlated mixed-signal work (with the UT-M15 logic probe pod), and SPI\/I²C\/UART protocol decode in one instrument — the typical entry-tier R\u0026amp;D bench in a single footprint.\u003c\/li\u003e\n\u003cli\u003eTime-correlated mixed-signal capture across analog channels and 16 digital lines (with the UT-M15 probe pod) on the same instrument and the same trigger event.\u003c\/li\u003e\n\u003cli\u003eStandard SPI, I²C, and RS-232\/UART decoding inline with captured waveforms; up to four simultaneous decodes plus parallel-bus decoding for custom protocols.\u003c\/li\u003e\n\u003cli\u003eZone triggering for rare-event hunting on intermittent timing anomalies, runts, and glitches.\u003c\/li\u003e\n\u003cli\u003e56 automated measurements with histogram and trend statistics for jitter analysis and long-capture characterization.\u003c\/li\u003e\n\u003cli\u003eFree firmware updates over the product’s lifetime; license unlocks for optional packages have no expiration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFor Education and Teaching Labs\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFor teaching labs running embedded-systems, instrumentation, or introductory electronics courses, the MSO2104X delivers a real four-channel scope plus an integrated AWG (optional), spectrum analyzer, protocol analyzer, and DVM — covering most of the bench-instrument curriculum on one operator-training surface, with HDMI projection for instructor-led demos.\u003c\/li\u003e\n\u003cli\u003eNine integrated instruments cover most of the bench-instrument curriculum on one operator-training surface, from analog-and-digital fundamentals through introductory power-electronics topics.\u003c\/li\u003e\n\u003cli\u003eHDMI output mirrors the display to a projector or external monitor for instructor-led demonstrations.\u003c\/li\u003e\n\u003cli\u003eWebServer remote access lets students view captures and run measurements from networked classroom devices without crowding the bench.\u003c\/li\u003e\n\u003cli\u003eCapacitive multi-touch UI plus traditional knob-and-key controls support a range of student comfort levels with bench-instrument operation.\u003c\/li\u003e\n\u003cli\u003e10.1-inch display with multi-window layout makes simultaneous waveform, FFT, decode, and measurement views visible during course exercises.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO2104X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAnalog Bandwidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCalculated Rise Time (10% to 90%, typical)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤3.50 ns\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAnalog Channels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDigital Channels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 (with optional UT-M15 probe pod)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Real-Time Sample Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 GSa\/s (interleave) \/ 2.5 GSa\/s (non-interleave)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Digital Sample Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.25 GSa\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Memory Depth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 Mpts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVertical Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8-bit native; up to 12-bit via ERES\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandard Capture Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500,000 wfms\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSequential Mode Capture Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2,000,000 wfms\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHardware Real-Time Recording\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e125,000 frames\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum Detectable Pulse Width (digital)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 ps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrigger Types\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEdge, pulse width, ramp, runt pulse, over-amplitude pulse, delay, timeout, duration, setup \u0026amp; hold, Nth edge, code pattern, video, zone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtocol Decoding (Standard)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRS-232\/UART, I²C, SPI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtocol Decoding (Optional)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCAN, CAN-FD, LIN, FlexRay, SENT, Audio (I²S\/LJ\/RJ\/TDM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSpectrum Analyzer (FFT)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 Hz to 2.5 GHz, up to 4 Mpts FFT, 4 traces, 4 detections, waterfall\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAWG (Optional MSO2000X-AWG)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 MHz, 2 channels, 16-bit, 250 MSa\/s; includes Bode plot analyzer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Analysis (Optional MSO2000X-PWR)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower quality, harmonic analysis, surge current, ripple analysis, loop analysis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAutomated Measurements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e56 (analog channels); up to 27 displayed simultaneously\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDigital Voltmeter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4-digit (DC, AC RMS, DC+AC RMS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency Counter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7-digit hardware counter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10.1-inch 1280×800 capacitive multi-touch, 24-bit color\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterfaces\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSB 3.0 Host (3) \/ USB 3.0 Device (1) \/ LAN (VXI-11) \/ HDMI \/ Gen Out (2) \/ 10 MHz In\/Out \/ AUX Out\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRemote Control\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSCPI; built-in WebServer (PC and mobile)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Source\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100–240 VAC, 50\/60 Hz; 120 W max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eAccessories \u0026amp; In the Box\u003c\/h4\u003e\n\u003ch3\u003eIncluded\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUT-P04 (100 MHz, 10:1 \/ 1:1) × 4 passive probes (one per channel)\u003c\/li\u003e\n\u003cli\u003eUT-D30 USB 3.0 cable\u003c\/li\u003e\n\u003cli\u003eUT-L45 BNC-to-BNC direct-through cable\u003c\/li\u003e\n\u003cli\u003eUT-L02A BNC red and black alligator connecting wire\u003c\/li\u003e\n\u003cli\u003eNational-standard power cable\u003c\/li\u003e\n\u003cli\u003eQuick start guide\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAvailable Options\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMSO2000X-AWG — Dual-channel 50 MHz AWG with Bode plot analyzer\u003c\/li\u003e\n\u003cli\u003eMSO2000X-PWR — Power analysis package (5 measurement types)\u003c\/li\u003e\n\u003cli\u003eMSO2000X-BND — All serial-bus triggering and decoding (CAN, CAN-FD, LIN, FlexRay, SENT, Audio)\u003c\/li\u003e\n\u003cli\u003eMSO2000X-AUTO — Automotive serial bus bundle (CAN, CAN-FD, LIN, FlexRay, SENT)\u003c\/li\u003e\n\u003cli\u003eMSO2000X-CAN \/ MSO2000X-CAN-FD \/ MSO2000X-LIN \/ MSO2000X-FLEX \/ MSO2000X-SENT \/ MSO2000X-AUDIO — Individual protocol licenses\u003c\/li\u003e\n\u003cli\u003eBandwidth upgrades: MSO2000X-BW1MT2M (100→200), MSO2000X-BW1MT3M (100→300), MSO2000X-BW2MT3M (200→300)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eRecommended Accessories\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUT-M15 — 16-channel logic probe pod\u003c\/li\u003e\n\u003cli\u003eUT-P07A — 500 MHz high-resistance passive probe\u003c\/li\u003e\n\u003cli\u003eUT-P20 \/ UT-P21 — High-voltage probes\u003c\/li\u003e\n\u003cli\u003eUT-P30 \/ UT-P31 \/ UT-P32 \/ UT-P33 — High-voltage differential probes\u003c\/li\u003e\n\u003cli\u003eUT-P40 \/ UT-P41 \/ UT-P42 \/ UT-P43 \/ UT-P44 — Current probes\u003c\/li\u003e\n\u003cli\u003eUT-ISOT — Isolation transformer\u003c\/li\u003e\n\u003cli\u003eUT-M13X — Oscilloscope demo board\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSoftware Options\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMSO2000X-AUDIO — Serial Bus Trigger and Analysis Option (I2S, LJ, RJ, TDM)\u003c\/li\u003e\n\u003cli\u003eMSO2000X-AUTO — Serial Bus Trigger and Decode Option (CAN, CAN-FD, LIN, FlexRay, SENT)\u003c\/li\u003e\n\u003cli\u003eMSO2000X-AWG — Arbitrary Waveform Generator Option\u003c\/li\u003e\n\u003cli\u003eMSO2000X-BND — Serial Bus Trigger and Decode Bundle (incl. AUTO, AUDIO)\u003c\/li\u003e\n\u003cli\u003eMSO2000X-CAN — Automotive CAN Serial Bus Trigger and Analysis\u003c\/li\u003e\n\u003cli\u003eMSO2000X-CANFD — Automotive CAN-FD Serial Bus Trigger and Analysis\u003c\/li\u003e\n\u003cli\u003eMSO2000X-FLEX — Automotive FlexRay Serial Bus Trigger and Analysis\u003c\/li\u003e\n\u003cli\u003eMSO2000X-LIN — Automotive LIN Serial Bus Trigger and Analysis\u003c\/li\u003e\n\u003cli\u003eMSO2000X-PWR — Power Analysis Option\u003c\/li\u003e\n\u003cli\u003eMSO2000X-SENT — Automotive SENT Sensor Bus Trigger and Analysis\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFamily Members\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMSO2204X (200 MHz, 4-channel)\u003c\/li\u003e\n\u003cli\u003eMSO2304X (300 MHz, 4-channel)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFAQ's\u003c\/h4\u003e\n\u003ch3\u003eWhat’s the difference between standard capture rate and Sequential Mode capture rate?\u003c\/h3\u003e\n\u003cp\u003eStandard capture rate (500,000 wfms\/s) is the rate at which the MSO2104X acquires waveforms during continuous real-time operation. Sequential Mode (2,000,000 wfms\/s) uses segmented memory to condition captures on a trigger event, holding up to 125,000 frames of triggered acquisitions for post-capture replay. Use standard mode for general waveform observation; use Sequential Mode for rare-event hunting where the trigger condition is well-defined and the captures-per-second matter.\u003c\/p\u003e\n\u003ch3\u003eIs the MSO2104X a 12-bit oscilloscope?\u003c\/h3\u003e\n\u003cp\u003eNo. The MSO2104X has an 8-bit native ADC with up to 12-bit effective resolution via ERES (enhanced resolution) when bandwidth headroom is available. For native 12-bit acquisition at full bandwidth and full sample rate, see UNI-T’s HD-series oscilloscopes (UPO1000HD, UPO2000HD, MSO1000HD, MSO3000HD, MSO5000HD, MSO8000HD), which use the R12™ native 12-bit ADC architecture.\u003c\/p\u003e\n\u003ch3\u003eAre the 16 digital channels included?\u003c\/h3\u003e\n\u003cp\u003eThe 16-digital-channel logic-analyzer front end is built into the chassis, but using it requires the optional UT-M15 probe pod. Without the UT-M15, the MSO2104X operates as a 4-channel digital storage oscilloscope.\u003c\/p\u003e\n\u003ch3\u003eWhat’s included with the AWG option?\u003c\/h3\u003e\n\u003cp\u003eThe MSO2000X-AWG package adds a 50 MHz dual-channel function and arbitrary waveform generator with 16-bit vertical resolution, 250 MSa\/s sample rate, and 200 built-in arbitrary waveforms. The Bode plot analyzer is included with the AWG package — it uses the AWG for stimulus and the scope channels for response measurement.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Uni-Trend US","offers":[{"title":"Default Title","offer_id":53265476124896,"sku":"181100300066X","price":1263.2,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/MSO2000X_1_sq.jpg?v=1782858082"},{"product_id":"upo2202hd-200-mhz-2ch-12-bit-high-resolution-oscilloscope","title":"UPO2202HD 200 MHz 2Ch 12-Bit High-Resolution Oscilloscope","description":"\u003ch1\u003eThe UNI-T UPO2202HD is a 200 MHz 2-channel 12-bit high-resolution oscilloscope built around the R12™ native 12-bit ADC.\u003c\/h1\u003e\n\u003cp\u003eIt samples at 2.5 GSa\/s with 100 Mpts memory depth standard, and Ultra Phosphor 3.0 acquisition pushes the waveform capture rate to 1,000,000 wfms\/s in sequence mode — sixteen times the vertical detail of an 8-bit scope, held at full bandwidth without ERES averaging or sample-rate trade-offs. The 10.1-inch capacitive multi-touch display, on-instrument 4 Mpts FFT, 9 standard protocol decoders, and built-in WebServer round out a six-instrument bench in a single chassis.\u003c\/p\u003e\n\u003cp\u003eFor power-electronics validation at the top of this family's bandwidth, the UPO2202HD pairs 200 MHz analog bandwidth with 70 µVrms background noise so that 12-bit resolution actually shows up on the screen instead of being buried in the noise floor. On a GaN\/SiC half-bridge measurement where switching-node ringing and DC-bias content compete for vertical headroom, the resolution gain is the difference between a debug session and an afternoon.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eR12™ 12-bit native ADC\u003c\/strong\u003e — 4,096 vertical levels held at the full 200 MHz bandwidth. No ERES averaging, no sample-rate trade-off.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e200 MHz bandwidth, 2 analog channels\u003c\/strong\u003e — 2.5 GSa\/s real-time sample rate, 100 Mpts standard memory depth. Full-bandwidth 12-bit resolution with 70 µVrms noise floor for power-electronics work.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUltra Phosphor 3.0 — 1,000,000 wfms\/s\u003c\/strong\u003e — Sequence-mode capture rate with 256-level grayscale persistence; surfaces intermittent and rare events.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e6 instruments in one\u003c\/strong\u003e — Oscilloscope, spectrum analyzer, digital voltmeter, hardware frequency meter, protocol analyzer, and optional power analysis on a single chassis.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e9 protocol decoders standard\u003c\/strong\u003e — RS-232\/UART, I²C, SPI, CAN, CAN-FD, LIN, FlexRay, SENT, and Audio. No license fees, no time-boxed unlocks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e10.1-inch capacitive touchscreen\u003c\/strong\u003e — 1280×800 multi-touch with pinch, drag, zoom, and rectangle-draw gestures. Mouse and keyboard supported in parallel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e4 Mpts enhanced FFT, 56 automated measurements, hardware mask test, zone trigger, ERES up to 4-bit\u003c\/strong\u003e — standard.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eDetailed Features\u003c\/h2\u003e\n\u003ch3\u003eR12™ — Native 12-Bit ADC at Full Bandwidth\u003c\/h3\u003e\n\u003cp\u003eR12™ is UNI-T's native 12-bit ADC architecture, holding 4,096 quantization levels at the full 200 MHz bandwidth and 2.5 GSa\/s sample rate without ERES averaging or sample-rate trade-off. Background noise is 70 µVrms at full bandwidth — low enough that the 12-bit resolution actually shows up on the screen instead of being buried in the noise floor. For power-electronics validation where µV-scale ripple rides on a 400V bias rail, that headroom is the measurement.\u003c\/p\u003e\n\u003ch3\u003eUltra Phosphor 3.0 — 1,000,000 wfms\/s Acquisition\u003c\/h3\u003e\n\u003cp\u003eUltra Phosphor 3.0 is UNI-T's third-generation acquisition engine. Eight-channel parallel graphics processing at up to 20 Gbps drives a continuous capture rate of 250,000 wfms\/s, with sequence mode pushing the rate to 1,000,000 wfms\/s for trigger-conditioned events. 256-level grayscale persistence makes intermittent runts, glitches, and jitter visible as density gradients on screen rather than as occasional flashes that the eye misses. The same engine drives the digital trigger system — high sensitivity, low jitter, and zone trigger for isolating non-repeating signals.\u003c\/p\u003e\n\u003ch3\u003e6 Instruments in One\u003c\/h3\u003e\n\u003cp\u003eThe UPO2202HD integrates six instrument functions into a single chassis: high-resolution oscilloscope, FFT spectrum analyzer with 4 Mpts and waterfall display, 4-digit digital voltmeter with DC\/AC RMS modes, 7-digit hardware frequency meter, 9-protocol decoder and trigger engine, and the optional 12-parameter power analysis suite. For 2-channel benchwork where rack space and budget both matter, the consolidation eliminates instrument switching and context loss during a single debug session.\u003c\/p\u003e\n\u003ch3\u003eDeep Memory — 100 Mpts Standard\u003c\/h3\u003e\n\u003cp\u003e100 Mpts of memory comes standard, not as an upgrade. At 2.5 GSa\/s that captures 40 ms of full-rate signal in a single acquisition — long enough to record a complete soft-start sequence, a fault-recovery transient, or a multi-frame burst without re-arming. Combined with hardware-accelerated mask testing, the 4-bit ERES enhanced-resolution mode, and uninterrupted recording of up to 125,000 frames, the deep memory turns long-running events from a sampling problem into a navigation problem.\u003c\/p\u003e\n\u003ch3\u003eAll Protocols Included Standard\u003c\/h3\u003e\n\u003cp\u003eNine serial-bus protocol decoders are included with every UPO2202HD: RS-232\/UART, I²C, SPI, CAN, CAN-FD, LIN, FlexRay, SENT, and Audio. Each protocol supports both triggering and decoding, with event-list and search functions for navigating long captures. Decoded data appears alongside the analog waveform on the same trace — correlate a misbehaving I²C transaction with the supply-rail glitch that caused it, or align CAN-FD frames with the gate-drive event that triggered the fault recovery. No license fees, no time-boxed unlocks — the protocols are standard.\u003c\/p\u003e\n\u003ch3\u003ePower Analysis — Optional 12-Parameter Suite\u003c\/h3\u003e\n\u003cp\u003eThe optional power-analysis package adds 12 measurement and analysis functions to the UPO2202HD: power quality, harmonic analysis, current harmonics, R\u003csub\u003eDS(on)\u003c\/sub\u003e, switching loss, slew rate, safe operating area, modulation analysis, output ripple, startup\/shutdown time, transient response, and power efficiency. Connect a voltage probe and a current probe, select the analysis type, and the UPO2202HD renders the results without external post-processing — the metrics that drive switching-converter design decisions, on the bench, alongside the time-domain trace.\u003c\/p\u003e\n\u003ch3\u003eBuilt-In Spectrum Analyzer — FFT to 4 Mpts\u003c\/h3\u003e\n\u003cp\u003eStandard enhanced FFT analysis runs at up to 4 Mpts across all channels with a frequency range from 0 to 1.25 GHz, four traces, four detection modes, and a waterfall display for tracking spectrum changes over time. Auto, manual, and threshold marker modes locate harmonics, spurs, and EMI sources without switching to a separate spectrum analyzer. For pre-compliance spot checks during board bring-up and switching-noise investigation during converter design, the on-instrument FFT closes a common bench-workflow gap.\u003c\/p\u003e\n\u003ch3\u003e56 Automated Measurements with Statistics\u003c\/h3\u003e\n\u003cp\u003e56 parameter measurements run continuously on every channel, with up to 27 measurements visible on screen and 39 single-channel parameters in the snapshot view. Statistics, histograms, and trend charts visualize each parameter's distribution over time. The new amplitude calculation strategy with top\/bottom and burst-parameter handling makes the numbers correct on signals where naive measurement engines pick the wrong reference levels. No post-processing, no spreadsheet export — the answer is on the screen.\u003c\/p\u003e\n\u003ch3\u003e10.1-Inch Touch UI and Full Connectivity\u003c\/h3\u003e\n\u003cp\u003eThe 10.1-inch 1280×800 capacitive multi-touch display supports pinch, drag, zoom, rectangle-draw, and edit gestures alongside the traditional knobs and one-touch front-panel keys. Mouse and keyboard are supported in parallel. The peripheral set includes USB Host, USB Device, LAN, EXT Trig, AUX Out (Trig Out \/ Pass-Fail), and HDMI for projector or external-monitor display. SCPI is standard, the built-in WebServer enables browser-based remote control from a PC or mobile device, and firmware updates are free over the product's lifetime. For automated power-converter qualification benches, the SCPI command set drives waveform capture, mask-test pass\/fail, and long-record export from a Python or LabVIEW test harness.\u003c\/p\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003ch3\u003eR\u0026amp;D Engineer (Embedded \/ Hardware \/ Analog Design)\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower-Electronics Validation\u003c\/strong\u003e — GaN\/SiC half-bridge characterization, switching-node ringing analysis, and µV-scale ripple-on-bias measurement at 200 MHz bandwidth with 70 µVrms noise floor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSerial-Bus Debug\u003c\/strong\u003e — Time-correlated analog and protocol-decode views in the same trace; 9 protocols included standard.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal-Integrity Spot Checks\u003c\/strong\u003e — On-instrument 4 Mpts FFT identifies harmonics, clock spurs, and EMI sources without switching to a separate spectrum analyzer.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLong-Capture Investigation\u003c\/strong\u003e — 100 Mpts memory plus 125,000-frame waveform recording captures complete soft-start, fault-recovery, and burst-mode events without re-arming.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePower Electronics Engineer\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFocused Switching-Node Characterization\u003c\/strong\u003e — 200 MHz bandwidth with 70 µVrms noise floor resolves GaN\/SiC switching-edge ringing and µV-scale ripple in the same acquisition.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptional 12-Parameter Power Analysis\u003c\/strong\u003e — Power quality, switching loss, R\u003csub\u003eDS(on)\u003c\/sub\u003e, SOA, transient response, and ripple analysis on the same instrument as the time-domain trace.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHardware-Accelerated Mask Testing\u003c\/strong\u003e — Pass\/fail validation against switching-waveform templates completes in seconds; AUX Out drives an alarm or DUT shutdown on out-of-mask events.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLong-Transient Capture\u003c\/strong\u003e — 100 Mpts captures complete soft-start and fault-recovery sequences in one trigger; 125,000-frame waveform recorder for repetitive burst-mode operation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBandwidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChannels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 Analog\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSample Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.5 GSa\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVertical Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 bits (R12™ native)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMemory Depth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 Mpts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCapture Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1,000,000 wfms\/s (sequence mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10.1-inch capacitive touchscreen, 1280×800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTouch Screen\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrigger Modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEdge, pulse width, video, ramp, runt, over-amplitude, delay, timeout, duration, setup\/hold, Nth edge, code pattern\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZone Trigger\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes — 2 zones, must-intersect \/ must-not-intersect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtocol Decoding (Standard)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRS-232\/UART, I²C, SPI, CAN, CAN-FD, LIN, FlexRay, SENT, Audio\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBuilt-In FFT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes — up to 4 Mpts, 0 to 1.25 GHz, 4 traces, waterfall\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBuilt-In Power Analysis\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOptional — 12 parameters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBuilt-In Spectrum Analyzer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes (standard FFT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDigital Voltmeter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4-digit; DC, AC RMS, AC+DC RMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency Meter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7-digit hardware\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAutomated Measurements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e56 with statistics, histogram, and trend\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eERES (Enhanced Resolution)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 4-bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMask Testing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHardware-accelerated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWaveform Recording\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 125,000 frames; USB export\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSB Host \/ USB Device \/ LAN \/ EXT Trig \/ AUX Out \/ HDMI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRemote Control\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSCPI standard; built-in WebServer (browser access)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRoHS Compliant\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCE, cETLus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eDownloads\u003c\/h4\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cbr\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/UPO2000HD_-_Data_Sheet_-_V1.1.pdf\" title=\"UPO2000 Series Datasheet\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/pdf-icon-63x63_480x480.png\" style=\"float: left;\" alt=\"PDF\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/850009-i.pdf\" target=\"_blank\"\u003e\u003cbr\u003e\u003c\/a\u003e\u003ca rel=\"noopener\" title=\"UNI-T UPO1000 Series Datasheet\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/UPO2000HD_-_Data_Sheet_-_V1.1.pdf?v=1783018853\" target=\"_blank\"\u003eUNI-T UPO2000HD Series Datasheet\u003c\/a\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cbr\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/UPO2000HD_-_User_Manual_-_V1.1.pdf\" title=\"UNI-T UPO2000HD Series Users Manual\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/pdf-icon-63x63_480x480.png\" style=\"float: left;\" alt=\"PDF\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/850009-i.pdf\" target=\"_blank\"\u003e\u003cbr\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/UPO2000HD_-_User_Manual_-_V1.1.pdf\" title=\"UN I-T UPO1000 Series Users Manual\" rel=\"noopener\" target=\"_blank\"\u003eUNI-T UPO2000HD Series Users Manual\u003c\/a\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eOptions \u0026amp; Accessories\u003c\/h4\u003e\n\u003ch3\u003eIncluded with the Instrument\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUPO2202HD oscilloscope\u003c\/li\u003e\n\u003cli\u003e2 × passive probes (1:1 \/ 10:1 switchable, bandwidth matched to instrument)\u003c\/li\u003e\n\u003cli\u003eUSB cable (USB-A to USB-B)\u003c\/li\u003e\n\u003cli\u003ePower cord (region-appropriate)\u003c\/li\u003e\n\u003cli\u003eQuick-start guide\u003c\/li\u003e\n\u003cli\u003eFactory calibration certificate\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eRecommended Accessories\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUPO2000HD-PWR — optional 12-parameter power-analysis package activation\u003c\/li\u003e\n\u003cli\u003eUT-P07A — 500 MHz passive probe for higher-bandwidth applications\u003c\/li\u003e\n\u003cli\u003eUT-P20, UT-P21, UT-V23 — high-voltage passive probes\u003c\/li\u003e\n\u003cli\u003eUT-P30, UT-P31, UT-P32, UT-P33 — differential probes for floating measurements\u003c\/li\u003e\n\u003cli\u003eUT-P40, UT-P41, UT-P42, UT-P43, UT-P44 — current probes for power-stage and switching-loss measurement\u003c\/li\u003e\n\u003cli\u003eUT-ISOT — isolation transformer for safe line-powered measurements\u003c\/li\u003e\n\u003cli\u003eUT-M13X — oscilloscope demo board for protocol decoding practice and curriculum modules\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSoftware Options\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUPO2000HD-PWR — Power Analysis Option for UPO2000HD\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eNeed different bandwidth or channel-count? Compare with family-mates: UPO2204HD, UPO2102HD, UPO2072HD.\u003c\/p\u003e\n\u003ch4\u003eFAQ's\u003c\/h4\u003e\n\u003ch3\u003eWhat protocols are included with the UPO2202HD?\u003c\/h3\u003e\n\u003cp\u003eRS-232\/UART, I²C, SPI, CAN, CAN-FD, LIN, FlexRay, SENT, and Audio decoding are included standard at no additional cost. All nine supported protocols are available out of the box — no optional licenses required, no time-boxed unlocks.\u003c\/p\u003e\n\u003ch3\u003eWhat is the advantage of native 12-bit resolution?\u003c\/h3\u003e\n\u003cp\u003eA 12-bit ADC provides 4,096 vertical levels compared to 256 for an 8-bit scope — sixteen times greater detail. This reveals small signals riding on large ones, reduces quantization noise, and improves measurement accuracy on low-amplitude signals like power-supply ripple, sensor outputs, and precision analog circuits. R12™ holds the 12-bit resolution at the full bandwidth and sample rate, with no ERES averaging or sample-rate trade-off.\u003c\/p\u003e\n\u003ch3\u003eCan I add power-supply analysis?\u003c\/h3\u003e\n\u003cp\u003eYes. The optional power-analysis package adds 12 measurements: power quality, harmonic analysis, current harmonics, R\u003csub\u003eDS(on)\u003c\/sub\u003e, switching loss, slew rate, safe operating area, modulation analysis, output ripple, startup\/shutdown time, transient response, and power efficiency. The UPO2000HD-PWR activation unlocks the package on any UPO2000HD-series oscilloscope.\u003c\/p\u003e\n\u003ch3\u003eHow does the touchscreen handle daily lab use?\u003c\/h3\u003e\n\u003cp\u003eThe 10.1-inch capacitive multi-touch display supports pinch, drag, zoom, rectangle-draw, and edit gestures alongside the traditional knobs and one-touch front-panel keys. Mouse and keyboard are supported in parallel. For lab settings where students or engineers cycle through the instrument frequently, the gesture set is familiar from consumer devices; for production-style workflows where physical controls are preferred, the front panel still does what front panels do.\u003c\/p\u003e\n\u003ch3\u003eHow does the UPO2202HD compare to 8-bit oscilloscopes at similar bandwidth?\u003c\/h3\u003e\n\u003cp\u003eThe 12-bit ADC delivers 16× the vertical resolution of an 8-bit scope at the same bandwidth, with no ERES averaging or sample-rate trade-off. Low-amplitude signals — switching ripple, sensor outputs, precision analog circuits — that 8-bit scopes flatten into quantization noise show up clearly on the 12-bit display. For analog precision work and switching-converter validation, the resolution advantage is structural, not a marketing comparison.\u003c\/p\u003e\n\u003ch3\u003eIs the firmware field-upgradable?\u003c\/h3\u003e\n\u003cp\u003eYes. Firmware updates are free over the product's lifetime and install via USB drive or LAN transfer. Optional license unlocks (such as the power-analysis package) have no expiration.\u003c\/p\u003e\n\u003ch3\u003eCan the instrument be controlled from a PC or from a browser?\u003c\/h3\u003e\n\u003cp\u003eBoth. SCPI is supported standard via USB Device or LAN for automated test scripts and PC-side instrument-management software. The built-in WebServer enables direct browser-based control from a PC or mobile device on the same network — no PC-side software install required.\u003c\/p\u003e\n\u003cp\u003ePart of the UPO2000HD oscilloscope series. All models share the R12™ native 12-bit ADC, 2.5 GSa\/s sample rate, 100 Mpts memory, Ultra Phosphor 3.0 acquisition, and 9 standard protocol decoders. Bandwidth options span 70 \/ 100 \/ 200 MHz; channel options are 2-channel and 4-channel. \u003c\/p\u003e","brand":"Uni-Trend US","offers":[{"title":"Default Title","offer_id":53265476157664,"sku":"181100200140X","price":924.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/UPO2202HD_1_sq.jpg?v=1782858082"},{"product_id":"mso2204x-200-mhz-4ch-mixed-signal-oscilloscope","title":"MSO2204X 200 MHz 4Ch Mixed Signal Oscilloscope","description":"\u003ch1\u003eThe MSO2204X is a 200 MHz, four-channel mixed-signal oscilloscope.\u003c\/h1\u003e\n\u003cp\u003eWith 5 GSa\/s real-time sample rate, 100 Mpts of memory depth, 16 logic-analyzer channels (with the optional UT-M15 probe pod), and Ultra Phosphor 3.0 waveform mapping at up to 2,000,000 wfms\/s in Sequential Mode, the MSO2204X integrates nine bench instruments into one 10.1-inch capacitive multi-touch footprint — oscilloscope, logic analyzer, AWG, spectrum analyzer, DVM, frequency counter, protocol analyzer, Bode plot, and power analyzer.\u003c\/p\u003e\n\u003cp\u003eFor mainstream R\u0026amp;D validation at 200 MHz, four-channel mixed-signal debug across faster MCU and FPGA silicon, and consolidation-tier lab benches that need spectrum, AWG, and protocol decode alongside scope acquisition, the MSO2204X is the mid SKU in the MSO2000X line — bridging bandwidth between the 100 MHz entry and the 300 MHz top. Same 5 GSa\/s sample rate and 100 Mpts memory as the rest of the family; same nine-instrument integration; 200 MHz of analog headroom fits the rise-time measurements that 100 MHz starts to round.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e200 MHz Bandwidth, 4 Analog Channels\u003c\/strong\u003e — Four-channel acquisition at up to 200 MHz with 5 GSa\/s sample rate (interleave) and calculated rise time of ≤1.80 ns.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e100 Mpts Memory Depth\u003c\/strong\u003e — Standard deep memory across all four channels for long capture windows without sample-rate trade.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUltra Phosphor 3.0 Display Technology\u003c\/strong\u003e — 256-level grayscale persistence with parallel FPGA mapping; up to 500,000 wfms\/s standard, 2,000,000 wfms\/s in Sequential Mode.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNine Instruments in One\u003c\/strong\u003e — Oscilloscope, 16-channel logic analyzer (optional probe), AWG (optional), 2.5 GHz spectrum analyzer, 4-digit DVM, 7-digit hardware frequency counter, protocol analyzer, Bode plot (with AWG), and power analyzer (optional).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard Protocol Decoding\u003c\/strong\u003e — RS-232\/UART, I²C, and SPI included as standard.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptional Protocols\u003c\/strong\u003e — CAN, CAN-FD, LIN, FlexRay, SENT, and Audio (I²S\/LJ\/RJ\/TDM) available as software licenses.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e16 Digital Channels (Optional)\u003c\/strong\u003e — Add mixed-signal capability with the UT-M15 logic probe pod; 1.25 GSa\/s digital sample rate, 800 ps minimum detectable pulse width.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptional 50 MHz Dual-Channel AWG\u003c\/strong\u003e — 16-bit, 250 MSa\/s arbitrary waveform generator with 200 built-in waveforms; Bode plot analyzer included with the AWG package.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eZone Triggering\u003c\/strong\u003e — Rectangle-drawn trigger conditions with Must Intersect \/ Must Not Intersect logic.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e56 Automated Measurements\u003c\/strong\u003e — Voltage, time, frequency, and statistical measurements with histogram and trend statistics; up to 27 displayed simultaneously.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e10.1-Inch Capacitive Multi-Touch\u003c\/strong\u003e — 1280×800 HD display with multi-window layout, gesture control, and HDMI output.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCPI and WebServer Remote Control\u003c\/strong\u003e — USB 3.0, LAN (VXI-11), and built-in browser-based control from PC or mobile.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFree Firmware Updates and No-Expiration License Unlocks\u003c\/strong\u003e — Firmware updates are free over the product’s lifetime; license unlocks for optional packages have no expiration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eDetailed Features\u003c\/h2\u003e\n\u003ch3\u003eNine Instruments in One\u003c\/h3\u003e\n\u003cp\u003eThe MSO2000X platform integrates nine instrument functions into one bench unit: digital storage oscilloscope, 16-channel logic analyzer (with the optional UT-M15 probe pod), 50 MHz dual-channel function and arbitrary waveform generator (optional), 2.5 GHz spectrum analyzer (FFT up to 4 Mpts), 4-digit digital voltmeter, 7-digit hardware frequency counter, multi-protocol serial-bus analyzer, Bode plot analyzer (optional, paired with the AWG for closed-loop sweep), and power-electronics analyzer (optional).\u003c\/p\u003e\n\u003cp\u003eFor lab benches consolidating across protocol decode, RF spectral analysis, and four-channel scope work in the same session, the integration eliminates the cable-swap-and-instrument-handoff cycle that breaks engineering flow on multi-instrument bench setups.\u003c\/p\u003e\n\u003ch3\u003eHigh-Speed Acquisition — 5 GSa\/s, 100 Mpts\u003c\/h3\u003e\n\u003cp\u003eThe 5 GSa\/s real-time sample rate (interleave mode) and 100 Mpts of acquisition memory hold full waveform fidelity across the 200 MHz analog bandwidth. Standard capture rate runs up to 500,000 wfms\/s; in Sequential Mode — the segmented-memory acquisition mode that conditions captures on a trigger event — capture rate climbs to 2,000,000 wfms\/s, holding up to 125,000 frames of uninterrupted hardware real-time waveform recording for post-capture replay and analysis.\u003c\/p\u003e\n\u003cp\u003eERES (enhanced resolution) extends effective vertical resolution from the 8-bit native ADC up to 12-bit when bandwidth headroom is available — useful for low-amplitude work where quantization noise would otherwise obscure detail on switching ripple, sensor outputs or jitter analysis.\u003c\/p\u003e\n\u003ch3\u003eUltra Phosphor 3.0 — 256-Level Grayscale Persistence\u003c\/h3\u003e\n\u003cp\u003eUltra Phosphor 3.0 is UNI-T’s third-generation waveform-mapping architecture, combining parallel FPGA acquisition with 256-level grayscale intensity grading. Throughput is five to ten times higher than the previous-generation pipeline, and acquisition dead time drops below 1 µs — the scope captures 1.17 ns fast-edge signals at 2,000,000 events per second in Sequential Mode without missing the rare-event bracket between redraws. The 256-level intensity grading shows signal frequency-of-occurrence directly: frequent waveforms appear brighter, infrequent ones dimmer, making it intuitive to distinguish normal behavior from intermittent faults during long bench captures.\u003c\/p\u003e\n\u003ch3\u003eBuilt-In Spectrum Analyzer — FFT to 4 Mpts\u003c\/h3\u003e\n\u003cp\u003eThe standard enhanced-FFT spectrum analyzer covers 0 Hz to 2.5 GHz with up to 4 Mpts of FFT length, four-channel signal analysis, four trace types (Normal, Average, Max Hold, Min Hold), and four detection modes. Marker functions cover Auto, Manual, and Threshold with a marker-point list, plus a waterfall display for tracking spectral activity over time. Use it to identify harmonics, characterize EMI signatures during pre-compliance sweeps, verify clock-signal purity on embedded designs, or analyze modulated signals — without paying for a separate spectrum analyzer.\u003c\/p\u003e\n\u003ch3\u003eProtocol Analysis — 9 Bus Types Across Four Domains\u003c\/h3\u003e\n\u003cp\u003eThe MSO2000X covers nine protocol types across four bus domains: computer serial (RS-232\/UART, I²C, SPI — standard), automotive serial (CAN, CAN-FD, LIN, FlexRay — optional), automotive sensor (SENT — optional), and audio (I²S, Left-Justified, Right-Justified, TDM — optional). Triggering and decoding are integrated: trigger on a frame error, an identifier match, a CRC failure, or a missing-ack condition, and the decode displays inline with the captured waveform. Up to four simultaneous decodes plus parallel-bus decoding (up to 18 bits, mixed analog and digital channels) cover most embedded-systems and automotive bus-validation workflows in one instrument.\u003c\/p\u003e\n\u003ch3\u003e50 MHz Dual-Channel AWG with Bode Plot (Optional)\u003c\/h3\u003e\n\u003cp\u003eThe optional MSO2000X-AWG package adds a 50 MHz dual-channel function and arbitrary waveform generator with 16-bit vertical resolution and 250 MSa\/s sample rate, plus the Bode plot analyzer for frequency-response, loop-stability, filter, and amplifier characterization. Built-in waveforms include sine, square, pulse, ramp, arbitrary, noise, and DC, with 200 standard arbitrary waveforms (Sinc, ExpRise, ExpFall, Cardiac, Gauss, Lorentz, HaverSine, and others). AM, FM, ASK, FSK, and sweep modulation are supported, and on-screen oscilloscope captures can be loaded directly into the AWG for stimulus-response replay.\u003c\/p\u003e\n\u003ch3\u003ePower Analysis (Optional) — Five Measurement Types\u003c\/h3\u003e\n\u003cp\u003eFor switching-power-supply validation at moderate frequencies and load-step transient analysis on point-of-load converters, the optional power-analysis package adds power quality, harmonic analysis, surge-current characterization, ripple analysis, and loop analysis to the four-channel acquisition path. The same scope that captures the gate-drive waveform also computes the switching loss across the cycle, replacing a separate power analyzer for early-stage characterization on switching converters and point-of-load designs.\u003c\/p\u003e\n\u003ch3\u003eZone Triggering — Rectangle-Drawn Trigger Conditions\u003c\/h3\u003e\n\u003cp\u003eZone triggering isolates an occasional anomaly by trigger condition rather than waveform stability. Draw a rectangle on the display, set Must Intersect or Must Not Intersect, and the scope triggers when the waveform meets the spatial condition — two zones supported, sourced from any of CH1 through CH4. Combined with the eleven trigger types (edge, pulse width, ramp, runt pulse, over-amplitude pulse, delay, timeout, duration, setup \u0026amp; hold, Nth edge, code pattern), the zone trigger turns rare-event hunting into a defined acquisition condition rather than a wait-and-watch exercise.\u003c\/p\u003e\n\u003ch3\u003e56 Automated Measurements with Histogram and Trend Statistics\u003c\/h3\u003e\n\u003cp\u003eThe MSO2000X provides 56 automated measurement parameters on the analog channels — voltage, time, frequency, statistical, and burst measurements — with up to 27 measurements displayed simultaneously and per-channel parameter snapshots showing 39 single-channel measurements at once. Measurement statistics include mean, maximum, minimum, standard deviation, count, tendency chart, and bar chart (histogram) views. The histogram surfaces parameter distribution visually; the tendency chart shows parameter drift over time — useful for jitter analysis, long-capture characterization, and pass\/fail evidence reports.\u003c\/p\u003e\n\u003ch3\u003eFast Fuzzy Autoset — Sub-Second All-Channel Setup\u003c\/h3\u003e\n\u003cp\u003eThe MSO2000X uses a fuzzy-logic autoset algorithm built around the 7-digit hardware frequency counter and multi-channel parallel processing. All-channel autoset completes in under 1.5 seconds; single-channel autoset completes in under 1 second — useful on production-line spot-check work and education-track lab benches with frequent setup changes.\u003c\/p\u003e\n\u003ch3\u003e10.1-Inch Capacitive Multi-Touch UI\u003c\/h3\u003e\n\u003cp\u003eThe 10.1-inch 1280×800 HD capacitive multi-touch display supports the standard touch gestures (click, slide, zoom, edit, drag) for direct waveform manipulation, plus rectangle-draw for zone triggering. Multi-window layout lets multiple display panels (waveform, FFT, decode list, measurement table) be dragged and resized independently. Traditional knob-and-key controls remain for engineers who prefer them, and external mouse and keyboard input is supported via USB. HDMI output mirrors the display to an external monitor or projector — useful for instructor-led demonstrations and engineering team reviews.\u003c\/p\u003e\n\u003ch3\u003eConnectivity, SCPI, and WebServer Remote Control\u003c\/h3\u003e\n\u003cp\u003eUSB 3.0 Host (one front, two rear), USB 3.0 Device (rear), LAN (10\/100\/1000 BASE-T, VXI-11), HDMI display output, two front-panel Gen Out connectors (paired with the optional AWG), 10 MHz reference In\/Out, and AUX Out (Trig Out \/ Pass-Fail \/ DVM). The instrument supports the full SCPI command set, and the built-in WebServer provides browser-based remote control from PC or mobile.\u003c\/p\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003ch3\u003eFor R\u0026amp;D Engineers\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFor R\u0026amp;D validation at 200 MHz, the MSO2204X covers ARM Cortex-M and faster ARM Cortex-A microcontroller debug, four-channel mixed-signal work on FPGA reference designs, and higher-bandwidth protocol decode where 100 MHz starts to limit visibility into rise-time and overshoot detail. With 16 digital channels via the UT-M15 logic probe pod, the same instrument captures analog-domain signal integrity and digital-domain protocol behavior in one time-correlated view.\u003c\/li\u003e\n\u003cli\u003eTime-correlated mixed-signal capture across analog channels and 16 digital lines (with the UT-M15 probe pod) on the same instrument and the same trigger event.\u003c\/li\u003e\n\u003cli\u003eStandard SPI, I²C, and RS-232\/UART decoding inline with captured waveforms; up to four simultaneous decodes plus parallel-bus decoding for custom protocols.\u003c\/li\u003e\n\u003cli\u003eZone triggering for rare-event hunting on intermittent timing anomalies, runts, and glitches.\u003c\/li\u003e\n\u003cli\u003e56 automated measurements with histogram and trend statistics for jitter analysis and long-capture characterization.\u003c\/li\u003e\n\u003cli\u003eFree firmware updates over the product’s lifetime; license unlocks for optional packages have no expiration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFor Education and Teaching Labs\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFor undergraduate and graduate-track engineering labs running advanced courses in embedded systems, communications, and signals-and-systems, the MSO2204X provides 200 MHz of analog bandwidth alongside the integrated nine-instrument suite — covering scope, FFT-based spectrum analysis, protocol decode, and AWG-driven stimulus work in one teaching-bench footprint, with HDMI projection for instructor-led demonstrations.\u003c\/li\u003e\n\u003cli\u003eNine integrated instruments cover most of the bench-instrument curriculum on one operator-training surface, from analog-and-digital fundamentals through introductory power-electronics topics.\u003c\/li\u003e\n\u003cli\u003eHDMI output mirrors the display to a projector or external monitor for instructor-led demonstrations.\u003c\/li\u003e\n\u003cli\u003eWebServer remote access lets students view captures and run measurements from networked classroom devices without crowding the bench.\u003c\/li\u003e\n\u003cli\u003eCapacitive multi-touch UI plus traditional knob-and-key controls support a range of student comfort levels with bench-instrument operation.\u003c\/li\u003e\n\u003cli\u003e10.1-inch display with multi-window layout makes simultaneous waveform, FFT, decode, and measurement views visible during course exercises.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO2204X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAnalog Bandwidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCalculated Rise Time (10% to 90%, typical)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤1.80 ns\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAnalog Channels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDigital Channels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 (with optional UT-M15 probe pod)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Real-Time Sample Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 GSa\/s (interleave) \/ 2.5 GSa\/s (non-interleave)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Digital Sample Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.25 GSa\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Memory Depth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 Mpts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVertical Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8-bit native; up to 12-bit via ERES\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandard Capture Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500,000 wfms\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSequential Mode Capture Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2,000,000 wfms\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHardware Real-Time Recording\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e125,000 frames\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum Detectable Pulse Width (digital)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 ps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrigger Types\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEdge, pulse width, ramp, runt pulse, over-amplitude pulse, delay, timeout, duration, setup \u0026amp; hold, Nth edge, code pattern, video, zone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtocol Decoding (Standard)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRS-232\/UART, I²C, SPI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtocol Decoding (Optional)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCAN, CAN-FD, LIN, FlexRay, SENT, Audio (I²S\/LJ\/RJ\/TDM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSpectrum Analyzer (FFT)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 Hz to 2.5 GHz, up to 4 Mpts FFT, 4 traces, 4 detections, waterfall\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAWG (Optional MSO2000X-AWG)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 MHz, 2 channels, 16-bit, 250 MSa\/s; includes Bode plot analyzer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Analysis (Optional MSO2000X-PWR)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower quality, harmonic analysis, surge current, ripple analysis, loop analysis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAutomated Measurements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e56 (analog channels); up to 27 displayed simultaneously\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDigital Voltmeter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4-digit (DC, AC RMS, DC+AC RMS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency Counter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7-digit hardware counter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10.1-inch 1280×800 capacitive multi-touch, 24-bit color\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterfaces\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSB 3.0 Host (3) \/ USB 3.0 Device (1) \/ LAN (VXI-11) \/ HDMI \/ Gen Out (2) \/ 10 MHz In\/Out \/ AUX Out\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRemote Control\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSCPI; built-in WebServer (PC and mobile)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Source\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100–240 VAC, 50\/60 Hz; 120 W max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4\u003eDownloads\u003c\/h4\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cbr\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cstrong\u003e\u003ca rel=\"noopener\" title=\"MSO2000X Series Datasheet\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/MSO2000X_-_Data_Sheet_-_V1.2.pdf\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/pdf-icon-63x63_480x480.png\" style=\"float: left;\" alt=\"PDF\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/850009-i.pdf\" target=\"_blank\"\u003e\u003cbr\u003e\u003c\/a\u003e\u003ca rel=\"noopener\" title=\"UNI-T MSO2000X Series Datasheet\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/MSO2000X_-_Data_Sheet_-_V1.2.pdf\" target=\"_blank\"\u003eUNI-T MSO2000X Series Datasheet\u003c\/a\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cbr\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/MSO3000X_-_MSO2000X_-_User_Manual_-_V1.2.pdf\" title=\"UNI-T MSO2000X Series Users Manual\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/pdf-icon-63x63_480x480.png\" style=\"float: left;\" alt=\"PDF\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/850009-i.pdf\" target=\"_blank\"\u003e\u003cbr\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/MSO3000X_-_MSO2000X_-_User_Manual_-_V1.2.pdf\" title=\"UNI-T MSO2000X Series Users Manual\" rel=\"noopener\" target=\"_blank\"\u003eUNI-T MSO2000X Series Users Manual\u003c\/a\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eOptions \u0026amp; Accessories\u003c\/h4\u003e\n\u003ch3\u003eIncluded\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUT-P05 (200 MHz, 10:1 \/ 1:1) × 4 passive probes (one per channel)\u003c\/li\u003e\n\u003cli\u003eUT-D30 USB 3.0 cable\u003c\/li\u003e\n\u003cli\u003eUT-L45 BNC-to-BNC direct-through cable\u003c\/li\u003e\n\u003cli\u003eUT-L02A BNC red and black alligator connecting wire\u003c\/li\u003e\n\u003cli\u003eNational-standard power cable\u003c\/li\u003e\n\u003cli\u003eQuick start guide\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAvailable Options\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMSO2000X-AWG — Dual-channel 50 MHz AWG with Bode plot analyzer\u003c\/li\u003e\n\u003cli\u003eMSO2000X-PWR — Power analysis package (5 measurement types)\u003c\/li\u003e\n\u003cli\u003eMSO2000X-BND — All serial-bus triggering and decoding (CAN, CAN-FD, LIN, FlexRay, SENT, Audio)\u003c\/li\u003e\n\u003cli\u003eMSO2000X-AUTO — Automotive serial bus bundle (CAN, CAN-FD, LIN, FlexRay, SENT)\u003c\/li\u003e\n\u003cli\u003eMSO2000X-CAN \/ MSO2000X-CAN-FD \/ MSO2000X-LIN \/ MSO2000X-FLEX \/ MSO2000X-SENT \/ MSO2000X-AUDIO — Individual protocol licenses\u003c\/li\u003e\n\u003cli\u003eBandwidth upgrades: MSO2000X-BW1MT2M (100→200), MSO2000X-BW1MT3M (100→300), MSO2000X-BW2MT3M (200→300)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eRecommended Accessories\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUT-M15 — 16-channel logic probe pod\u003c\/li\u003e\n\u003cli\u003eUT-P07A — 500 MHz high-resistance passive probe\u003c\/li\u003e\n\u003cli\u003eUT-P20 \/ UT-P21 — High-voltage probes\u003c\/li\u003e\n\u003cli\u003eUT-P30 \/ UT-P31 \/ UT-P32 \/ UT-P33 — High-voltage differential probes\u003c\/li\u003e\n\u003cli\u003eUT-P40 \/ UT-P41 \/ UT-P42 \/ UT-P43 \/ UT-P44 — Current probes\u003c\/li\u003e\n\u003cli\u003eUT-ISOT — Isolation transformer\u003c\/li\u003e\n\u003cli\u003eUT-M13X — Oscilloscope demo board\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSoftware Options\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMSO2000X-AUDIO — Serial Bus Trigger and Analysis Option (I2S, LJ, RJ, TDM)\u003c\/li\u003e\n\u003cli\u003eMSO2000X-AUTO — Serial Bus Trigger and Decode Option (CAN, CAN-FD, LIN, FlexRay, SENT)\u003c\/li\u003e\n\u003cli\u003eMSO2000X-AWG — Arbitrary Waveform Generator Option\u003c\/li\u003e\n\u003cli\u003eMSO2000X-BND — Serial Bus Trigger and Decode Bundle (incl. AUTO, AUDIO)\u003c\/li\u003e\n\u003cli\u003eMSO2000X-CAN — Automotive CAN Serial Bus Trigger and Analysis\u003c\/li\u003e\n\u003cli\u003eMSO2000X-CANFD — Automotive CAN-FD Serial Bus Trigger and Analysis\u003c\/li\u003e\n\u003cli\u003eMSO2000X-FLEX — Automotive FlexRay Serial Bus Trigger and Analysis\u003c\/li\u003e\n\u003cli\u003eMSO2000X-LIN — Automotive LIN Serial Bus Trigger and Analysis\u003c\/li\u003e\n\u003cli\u003eMSO2000X-PWR — Power Analysis Option\u003c\/li\u003e\n\u003cli\u003eMSO2000X-SENT — Automotive SENT Sensor Bus Trigger and Analysis\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFamily Members\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMSO2104X (100 MHz, 4-channel)\u003c\/li\u003e\n\u003cli\u003eMSO2304X (300 MHz, 4-channel)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFAQ's\u003c\/h4\u003e\n\u003ch3\u003eWhat’s the difference between standard capture rate and Sequential Mode capture rate?\u003c\/h3\u003e\n\u003cp\u003eStandard capture rate (500,000 wfms\/s) is the rate at which the MSO2204X acquires waveforms during continuous real-time operation. Sequential Mode (2,000,000 wfms\/s) uses segmented memory to condition captures on a trigger event, holding up to 125,000 frames of triggered acquisitions for post-capture replay. Use standard mode for general waveform observation; use Sequential Mode for rare-event hunting where the trigger condition is well-defined and the captures-per-second matter.\u003c\/p\u003e\n\u003ch3\u003eIs the MSO2204X a 12-bit oscilloscope?\u003c\/h3\u003e\n\u003cp\u003eNo. The MSO2204X has an 8-bit native ADC with up to 12-bit effective resolution via ERES (enhanced resolution) when bandwidth headroom is available. For native 12-bit acquisition at full bandwidth and full sample rate, see UNI-T’s HD-series oscilloscopes (UPO1000HD, UPO2000HD, MSO1000HD, MSO3000HD, MSO5000HD, MSO8000HD), which use the R12™ native 12-bit ADC architecture.\u003c\/p\u003e\n\u003ch3\u003eAre the 16 digital channels included?\u003c\/h3\u003e\n\u003cp\u003eThe 16-digital-channel logic-analyzer front end is built into the chassis, but using it requires the optional UT-M15 probe pod. Without the UT-M15, the MSO2204X operates as a 4-channel digital storage oscilloscope.\u003c\/p\u003e\n\u003ch3\u003eWhat’s included with the AWG option?\u003c\/h3\u003e\n\u003cp\u003eThe MSO2000X-AWG package adds a 50 MHz dual-channel function and arbitrary waveform generator with 16-bit vertical resolution, 250 MSa\/s sample rate, and 200 built-in arbitrary waveforms. The Bode plot analyzer is included with the AWG package. It uses the AWG for stimulus and the scope channels for response measurement.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Uni-Trend US","offers":[{"title":"Default Title","offer_id":53265476288736,"sku":"181100300065X","price":1599.2,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/MSO2000X_1_sq_69a7370b-a5b0-4c15-bbcd-61eb7be10dc2.jpg?v=1782858083"},{"product_id":"mso3024hd-200-mhz-4ch-12-bit-mixed-signal-oscilloscope","title":"MSO3024HD 200 MHz 4Ch 12-Bit Mixed Signal Oscilloscope","description":"\u003ch1\u003eThe MSO3024HD is a 200 MHz, 4-channel mixed signal oscilloscope built on the R12™ native 12-bit ADC architecture, with 2.5 GSa\/s sample rate and 500 Mpts standard memory depth.\u003c\/h1\u003e\n\u003cp\u003e12-bit resolution holds at full bandwidth without ERES averaging or sample-rate trade-offs, and Ultra Phosphor 3.0 acquisition delivers 500,000 wfms\/s standard — 1,500,000 wfms\/s in Sequential Mode. Sixteen digital channels are available with the UT-M15 logic probe pod, on a 10.1-inch capacitive multi-touch display.\u003c\/p\u003e\n\u003cp\u003eFor embedded prototyping, MCU validation, and mixed-signal debug in small R\u0026amp;D groups, the MSO3024HD brings the full HD-scope spec story — native 12-bit, 500 Mpts memory, the nine-instrument workhorse platform — to the family entry price. Switching-supply ripple riding on a noisy DC rail, sensor-bridge outputs that disappear into 8-bit quantization, and gate-drive timing across four channels all show up clearly on the screen instead of inside the noise floor.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e200 MHz Bandwidth, 4 Analog Channels\u003c\/strong\u003e — Full 200 MHz on every channel with a calculated rise time of ≤1.80 ns, the family entry into native 12-bit work.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eR12™ Native 12-Bit ADC\u003c\/strong\u003e — 4,096 quantization levels held at full bandwidth and full sample rate — no ERES averaging required, no sample-rate trade. Up to 16-bit effective resolution with ERES enabled.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e2.5 GSa\/s Sample Rate, 500 Mpts Memory\u003c\/strong\u003e — Real-time sampling up to 2.5 GSa\/s (interleave) with 500 Mpts maximum storage per channel for long-window capture without sample-rate compromise.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUltra Phosphor 3.0 Acquisition\u003c\/strong\u003e — 500,000 wfms\/s standard capture rate; 1,500,000 wfms\/s in Sequential Mode for trigger-conditioned anomaly hunting. 256-level intensity grading reveals rare events that slower scopes miss.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNine Instruments in One\u003c\/strong\u003e — Oscilloscope, logic analyzer, function\/AWG, spectrum analyzer, digital voltmeter, frequency counter, Bode plot analyzer, protocol analyzer, and power analyzer — integrated into a single bench instrument.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e16 Digital Channels (Optional)\u003c\/strong\u003e — Add the UT-M15 logic probe pod for full mixed-signal debug across analog and digital domains with time-correlated triggering and decoding.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e12 Protocol Decoders\u003c\/strong\u003e — Standard: RS-232\/UART, RS-422\/485, I²C, SPI, CAN. Optional: CAN-FD, LIN, FlexRay, SENT, Audio, MIL-STD-1553B, ARINC 429, Manchester.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e54 Automated Measurements with Statistics\u003c\/strong\u003e — Voltage, time, and frequency-domain measurements with histogram and trend-line display. Up to 27 simultaneous on-screen measurements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptional 50 MHz Dual-Channel AWG\u003c\/strong\u003e — Add a built-in 16-bit dual-channel arbitrary waveform generator with Bode plot loop-stability analysis. Drive stimulus-response testing from the same instrument that captures the response.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e10.1-Inch Multi-Touch Display + WebServer + SCPI\u003c\/strong\u003e — 1280 × 800 capacitive touchscreen with gesture control, browser-based remote access, and full SCPI automation over USB 3.0, LAN, and HDMI export.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eDetailed Features\u003c\/h2\u003e\n\u003ch3\u003eR12™ — Native 12-Bit at Full Bandwidth\u003c\/h3\u003e\n\u003cp\u003eR12™ is UNI-T’s native 12-bit ADC architecture: 4,096 vertical quantization levels — sixteen times the resolution of a conventional 8-bit oscilloscope — held at the full 200 MHz bandwidth and 2.5 GSa\/s sample rate, with no ERES averaging step and no sample-rate trade-off to claim it. For embedded prototyping where the alternative at this price is an 8-bit scope, R12 means quantization steps disappear from low-amplitude signals: switching-supply ripple riding on a noisy DC rail, thermistor curves on a sensor bench, current-shunt waveforms on a DUT — all resolve into clean traces instead of staircases on the screen.\u003c\/p\u003e\n\u003ch3\u003eUltra Phosphor 3.0 — 1,500,000 wfms\/s in Sequential Mode\u003c\/h3\u003e\n\u003cp\u003eUltra Phosphor 3.0 is UNI-T’s third-generation waveform-mapping architecture, combining parallel FPGA acquisition with 256-level grayscale intensity grading. Standard waveform capture rate is 500,000 wfms\/s — high enough to surface intermittent timing anomalies on a long capture window. In Sequential Mode — the segmented-memory acquisition mode that conditions captures on a trigger event — capture rate climbs to 1,500,000 wfms\/s, and the scope holds up to 125,000 frames of uninterrupted hardware real-time recording for post-capture replay and analysis. Rare-event hunting on a live system stops being a watch-and-wait exercise and starts being a hunt with the right tool for it.\u003c\/p\u003e\n\u003ch3\u003eNine Instruments in One — The HD Workhorse\u003c\/h3\u003e\n\u003cp\u003eThe MSO3024HD integrates nine instruments in a single chassis: digital oscilloscope, 16-channel logic analyzer (with optional UT-M15 probe), 50 MHz dual-channel function\/arbitrary waveform generator (optional), 4 Mpts FFT spectrum analyzer, 4-digit digital voltmeter, 7-digit hardware frequency counter, Bode plot analyzer (with AWG option), protocol analyzer, and power analyzer (optional). For an entry-tier R\u0026amp;D bench where rack space, instrument budget, and bench cabling all compete with the work, that consolidation matters: an MCU project can move from prototype to validation without acquiring three additional instruments to do it.\u003c\/p\u003e\n\u003ch3\u003eDeep Memory — 500 Mpts Per Channel\u003c\/h3\u003e\n\u003cp\u003e500 Mpts maximum storage depth per channel is the deepest memory in this product class. On a long-window acquisition, the alternative on shallow-memory scopes is the sample-rate trade-off: extend the time base, lose sample rate, lose the high-frequency content that mattered. The MSO3000HD’s memory budget eliminates that trade for capture windows up to 200 ms at the full 2.5 GSa\/s sample rate. Boot-sequence captures on a microcontroller, full power-on transient analysis on a switching converter, multi-frame protocol traces — the memory holds the whole event at full resolution. Selectable depths from 25 kpts up to 500 Mpts let the engineer match memory to workflow without leaving the instrument.\u003c\/p\u003e\n\u003ch3\u003e16 Digital Channels with the UT-M15 Logic Probe\u003c\/h3\u003e\n\u003cp\u003e16 digital channels are hardware-standard on the MSO3024HD — the acquisition path, channel-to-channel correlation, and trigger system are all built in. Adding the optional UT-M15 logic probe pod activates the digital input front end. The probe pod uses high 8-bit and low 8-bit signal groupings on a 2.54 mm pin header, with 101 kΩ input impedance and 9.0 pF capacitive loading — light enough not to perturb the DUT, fast enough to resolve 800 ps minimum pulse width at the full 1.25 GSa\/s digital sample rate. Time-correlated triggering across analog and digital channels turns the MSO3024HD into a full mixed-signal debug instrument for embedded systems where the bug lives at the boundary between the firmware and the analog rail.\u003c\/p\u003e\n\u003ch3\u003e12 Protocol Decoders — 3 Standard, 9 Optional\u003c\/h3\u003e\n\u003cp\u003eTwelve protocol decoders cover embedded, automotive, audio, and aerospace applications. Three are standard: RS-232\/UART, RS-422\/485, I²C, SPI, and CAN ship with the instrument and decode at no additional cost. Nine are field-upgradable license unlocks: CAN-FD, LIN, FlexRay, SENT, Audio, MIL-STD-1553B, ARINC 429, and Manchester — one license per protocol family, no expiration, no subscription. Decoded frames overlay the analog waveform with field-level annotation, and the event list and search functions navigate captured traffic without leaving the instrument. Up to four protocols can decode simultaneously; up to 18 bits of parallel-bus decoding combines analog and digital channels for legacy buses.\u003c\/p\u003e\n\u003ch3\u003eBuilt-In Spectrum Analyzer — 4 Mpts FFT to 2.5 GHz\u003c\/h3\u003e\n\u003cp\u003eAn enhanced FFT engine of up to 4 Mpts runs as a dedicated frequency-domain analysis mode on the instrument. Frequency range covers 0 to 2.5 GHz, four traces and four detection types (positive peak, negative peak, sample, average) display simultaneously, and the waterfall view tracks spectral content over time for intermittent emissions. Three marker types (auto, manual, threshold) and a marker-point list support EMI pre-screen, harmonic analysis, signal-purity checks, and switching-noise characterization. The same channel that captures the time-domain trace runs the FFT — no signal transfer, no recapture, no de-synchronized traces between two instruments.\u003c\/p\u003e\n\u003ch3\u003ePower Analysis — Optional 6-Class Suite\u003c\/h3\u003e\n\u003cp\u003eThe optional Power Analysis package adds six classes of power-electronics measurement to the MSO3024HD: switching-loss analysis, output ripple, harmonic analysis, slew rate, modulation analysis, and safe operating area (SOA). For early-stage power-converter design, the package replaces a separate power-analyzer instrument: the same scope that captures the gate-drive waveform calculates the switching loss across the cycle, and the same FFT mode that screens for spurs computes the harmonic spectrum on the AC input. Connect a voltage probe and a current probe, select the analysis type, and the calculations run on-instrument.\u003c\/p\u003e\n\u003ch3\u003e54 Automated Measurements with Statistics\u003c\/h3\u003e\n\u003cp\u003e54 automated measurement types cover voltage, time, frequency-domain, and area-under-curve calculations — with up to 27 measurements displayed simultaneously on screen and a 39-item single-channel parameter snapshot for production-style documentation. Histogram and trend-line displays show measurement statistics over time for jitter analysis, drift characterization, and long-window validation runs. Measurements run continuously during acquisition, refresh in real time, and stay correlated with the cursor position when manual analysis takes over.\u003c\/p\u003e\n\u003ch3\u003e10.1-Inch Touch UI, WebServer, and SCPI Automation\u003c\/h3\u003e\n\u003cp\u003eThe 10.1-inch capacitive multi-touch display (1280 × 800) supports gesture control — tap, slide, pinch-zoom, drag-and-drop — alongside traditional knob, key, and mouse\/keyboard input. The built-in WebServer exposes the instrument over a browser for cross-platform remote access (PC, tablet, phone), with full waveform export and online user-manual browsing built in. SCPI over USB 3.0 and LAN drops the MSO3024HD into automated bench scripts, and HDMI output mirrors the screen to an external display for teaching, presentation, or large-screen analysis. Mask (template) testing accelerates production go\/no-go cycles in hardware, and the 7-bit precision Autoset uses fuzzy logic to find the right scale and time base across multi-channel inputs in a single button press.\u003c\/p\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003ch3\u003eR\u0026amp;D and Embedded Engineering\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMicrocontroller bring-up and embedded validation\u003c\/strong\u003e — 4-channel 12-bit capture across UART, SPI, I²C, and the analog rail keeps firmware-to-hardware boundary debug on one instrument; the 200 MHz bandwidth covers the clock rates that current-generation MCUs actually run at.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMixed-signal debug across analog and digital domains\u003c\/strong\u003e — with the optional UT-M15 16-channel logic probe pod, the MSO3024HD time-correlates firmware events with analog rails for bug isolation at the boundary.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtocol bring-up and bus traffic analysis\u003c\/strong\u003e — standard RS-232\/UART, I²C, SPI, CAN decoding (plus optional CAN-FD, LIN, FlexRay, etc.) with frame-level annotation on the analog waveform.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLong-window event capture for intermittent bugs\u003c\/strong\u003e — 500 Mpts memory and 125,000-frame Sequential Mode hold the full event window at full sample rate, so the bug doesn’t have to recur during a manual capture window.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePower Electronics\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitching-supply ripple and DC-rail analysis\u003c\/strong\u003e — 12-bit native resolution surfaces µV-scale ripple riding on the DC rail without the quantization noise that obscures it on 8-bit instruments, with the optional Power Analysis package adding integrated switching-loss measurement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMI pre-screen on switching converters\u003c\/strong\u003e — 4 Mpts FFT to 2.5 GHz with waterfall display surfaces conducted-emission spurs before the chamber visit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoop-stability validation with optional Bode plot analysis\u003c\/strong\u003e — with the AWG option enabled, drive small-signal injection and measure the closed-loop response from one instrument across 50 Hz to 50 MHz.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMulti-rail correlation\u003c\/strong\u003e — four analog channels capture input, output, reference, and feedback signals on a complex switching topology in a single time-aligned acquisition.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTeaching Labs and Curriculum Use\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurriculum-friendly multi-instrument teaching\u003c\/strong\u003e — one oscilloscope per bench replaces three or four legacy instruments in a teaching lab, with WebServer access for instructor mirroring across student stations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVisual demonstration of frequency-domain analysis\u003c\/strong\u003e — the built-in 4 Mpts FFT spectrum analyzer makes time-frequency duality demonstrable on the same instrument students already know.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMixed-signal lab work without a separate logic analyzer\u003c\/strong\u003e — with the optional UT-M15 probe pod, students capture analog and digital signals on one screen for embedded-systems coursework.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRepeatable lab exercises with SCPI automation\u003c\/strong\u003e — instructor-prepared Python scripts drive consistent measurements across student bench stations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBandwidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChannels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 Analog + 16 Digital (optional UT-M15 probe)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSample Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.5 GSa\/s (interleave) \/ 1.25 GSa\/s (non-interleave)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVertical Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12-bit (up to 16-bit with ERES)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMemory Depth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 Mpts maximum per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCapture Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500,000 wfms\/s standard; 1,500,000 wfms\/s in Sequential Mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCalculated Rise Time (Typ.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤1.80 ns\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBackground Noise (full BW, Typ.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e70 µVrms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10.1 inches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1280 × 800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTouch Screen\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCapacitive multi-touch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrigger Modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEdge, Pulse Width, Video, Slope, Runt, Over-Amplitude, Delay, Timeout, Duration, Setup \u0026amp; Hold, Nth Edge, Pattern, Zone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtocol Decoders — Standard\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRS-232\/UART, RS-422\/485, I²C, SPI, CAN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtocol Decoders — Optional\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCAN-FD, LIN, FlexRay, SENT, Audio, MIL-STD-1553B, ARINC 429, Manchester\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFFT (Spectrum Analyzer)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 4 Mpts; 0 to 2.5 GHz; 4 traces, 4 detections, waterfall\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Analysis (Optional)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 classes: switching loss, ripple, harmonics, slew rate, modulation, SOA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBuilt-In AWG (Optional)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 MHz dual-channel, 16-bit, 250 MSa\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBode Plot (with AWG option)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 Hz to 50 MHz, 1–1000 points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDVM\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4-digit; DC, AC RMS, AC+DC RMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency Counter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7-digit hardware\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAutomated Measurements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e54 types; up to 27 simultaneous on-screen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSequential Mode Frames\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 125,000 frames\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSB 3.0 Host, USB Device, LAN, HDMI, AUX (Trig Out \/ Pass-Fail \/ DVM), Gen Out × 2, 10 MHz In\/Out, EXT Trig\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRemote Control\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWebServer (browser-based), SCPI over USB \/ LAN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCE, cETLus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4\u003eDownloads\u003c\/h4\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cbr\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cstrong\u003e\u003ca rel=\"noopener\" title=\"MSO3000HD Series Datasheet\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/MSO3000HD_-_Data_Sheet_-_V1.2.pdf\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/pdf-icon-63x63_480x480.png\" style=\"float: left;\" alt=\"PDF\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/850009-i.pdf\" target=\"_blank\"\u003e\u003cbr\u003e\u003c\/a\u003e\u003ca rel=\"noopener\" title=\"UNI-T MSO3000HD Series Datasheet\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/MSO3000HD_-_Data_Sheet_-_V1.2.pdf\" target=\"_blank\"\u003eUNI-T MSO3000 Series Datasheet\u003c\/a\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cbr\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cstrong\u003e\u003ca rel=\"noopener\" title=\"UNI-T UPO1000 Series Users Manual\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/UPO1000_-_User_Manual_-_V1.0.pdf?v=1782927452\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/pdf-icon-63x63_480x480.png\" style=\"float: left;\" alt=\"PDF\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/850009-i.pdf\" target=\"_blank\"\u003e\u003cbr\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/UPO1000_-_User_Manual_-_V1.0.pdf\" title=\"UN I-T UPO1000 Series Users Manual\" rel=\"noopener\" target=\"_blank\"\u003eUNI-T MSO3000 Series Users Manual\u003c\/a\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4\u003eAccessories \u0026amp; In the Box\u003c\/h4\u003e\n\u003ch3\u003eIncluded\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMSO3024HD mixed signal oscilloscope\u003c\/li\u003e\n\u003cli\u003e4 × UT-P05 100 MHz, 10:1\/1:1 passive probes (200 MHz family) or UT-P06 200 MHz, 10:1\/1:1 passive probes (350\/500 MHz family)\u003c\/li\u003e\n\u003cli\u003eAC power cord (region-specific)\u003c\/li\u003e\n\u003cli\u003eUSB cable, certificate of conformity, quick start guide\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eRecommended Accessories\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUT-M15 16-channel logic analyzer probe pod — activate s the 16 standard digital channels for mixed-signal debug.\u003c\/li\u003e\n\u003cli\u003eUT-P series passive, differential, and current probes — matched probes for high-voltage, high-current, and differential measurements.\u003c\/li\u003e\n\u003cli\u003eOptional protocol decode licenses (CAN-FD, LIN, FlexRay, SENT, Audio, MIL-STD-1553B, ARINC 429, Manchester) — field-upgradable, no expiration.\u003c\/li\u003e\n\u003cli\u003eOptional 50 MHz dual-channel AWG license — adds stimulus-response and Bode plot capability to the same instrument.\u003c\/li\u003e\n\u003cli\u003eOptional Power Analysis package — six-class power-electronics measurement suite.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSoftware Options\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMSO3000HD-ARINC429 — Aerospace ARINC429 Serial Bus Trigger and Analysis\u003c\/li\u003e\n\u003cli\u003eMSO3000HD-AUDIO — Serial Bus Trigger and Analysis Option (I2S, LJ, RJ, TDM)\u003c\/li\u003e\n\u003cli\u003eMSO3000HD-AUTO — Serial Bus Trigger and Decode Bundle (CAN, CAN-FD, LIN, FlexRay, SENT)\u003c\/li\u003e\n\u003cli\u003eMSO3000HD-AWG — Arbitrary Waveform Generator option\u003c\/li\u003e\n\u003cli\u003eMSO3000HD-BND — Serial Bus Trigger and Decode Bundle (incl. AUTO, AUDIO, MIL-STD, ARINC429, MANCH)\u003c\/li\u003e\n\u003cli\u003eMSO3000HD-BW2MT3M5 — 350MHz Bandwidth Upgrade\u003c\/li\u003e\n\u003cli\u003eMSO3000HD-CAN — Automotive CAN Serial Bus Trigger and Analysis\u003c\/li\u003e\n\u003cli\u003eMSO3000HD-CANFD — Automotive CAN-FD Serial Bus Trigger and Analysis\u003c\/li\u003e\n\u003cli\u003eMSO3000HD-FLEX — Automotive FlexRay Serial Bus Trigger and Analysis\u003c\/li\u003e\n\u003cli\u003eMSO3000HD-LIN — Automotive LIN Serial Bus Trigger and Analysis\u003c\/li\u003e\n\u003cli\u003eMSO3000HD-MANCH — Manchester Serial Bus Trigger and Analysis Option\u003c\/li\u003e\n\u003cli\u003eMSO3000HD-MIL1553 — MIL-STD-1553 Serial Bus Trigger and Analysis Option\u003c\/li\u003e\n\u003cli\u003eMSO3000HD-PWR — Power Analysis Option\u003c\/li\u003e\n\u003cli\u003eMSO3000HD-SENT — Automotive SENT Sensor Bus Trigger and Analysis\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFamily Members\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMSO3034HD — 350 MHz, 4ch — bandwidth headroom for faster MCU clocks and switching nodes\u003c\/li\u003e\n\u003cli\u003eMSO3054HD — 500 MHz, 4ch — full family flagship with 70 µVrms noise floor\u003c\/li\u003e\n\u003cli\u003eMSO1254HD — 250 MHz, 2ch HD — step-down for 2-channel work\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFAQ's\u003c\/h4\u003e\n\u003ch3\u003e\n\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003eWhat protocols are included standard, and what are optional?\u003c\/h3\u003e\n\u003cp\u003eStandard decoders: RS-232\/UART, RS-422\/485, I²C, SPI, and CAN. Optional license unlocks: CAN-FD, LIN, FlexRay, SENT, Audio, MIL-STD-1553B, ARINC 429, and Manchester. Optional licenses do not expire; firmware updates are free over the product’s lifetime.\u003c\/p\u003e\n\u003ch3\u003eWhat does R12™ mean in practice?\u003c\/h3\u003e\n\u003cp\u003eR12™ is UNI-T’s native 12-bit ADC architecture — 4,096 vertical quantization levels, sixteen times the resolution of an 8-bit ADC, held at the full bandwidth and sample rate with no ERES averaging required. ERES is available as an enhancement on top of R12 (up to 16-bit effective resolution); on competing scopes, ERES is required to claim 12-bit at all and trades bandwidth or sample rate to do it.\u003c\/p\u003e\n\u003ch3\u003eCan I add the AWG and logic-analyzer capabilities later?\u003c\/h3\u003e\n\u003cp\u003eYes. The 16-channel logic analyzer is hardware-standard; activating it requires the optional UT-M15 logic probe pod. The 50 MHz dual-channel AWG (with Bode plot) is a license unlock. Both are field-upgradable on instruments already in service. License unlocks do not expire.\u003c\/p\u003e\n\u003ch3\u003eWhat’s the difference between the standard 500,000 wfms\/s and Sequential Mode’s 1,500,000 wfms\/s?\u003c\/h3\u003e\n\u003cp\u003e500,000 wfms\/s is the continuous capture rate the instrument sustains across normal operation. Sequential Mode is a segmented-memory acquisition mode that conditions captures on a trigger event and uses the memory budget to record up to 125,000 frames of trigger-aligned waveforms back-to-back; the 1,500,000 wfms\/s figure is the effective capture rate during Sequential Mode operation. Sequential Mode is the right tool for hunting rare or intermittent events; the standard mode is the right tool for continuous monitoring.\u003c\/p\u003e\n\u003ch3\u003eShould I size up to the MSO3034HD or MSO3054HD instead?\u003c\/h3\u003e\n\u003cp\u003eThe MSO3024HD is the family entry at 200 MHz, and that bandwidth covers the majority of current-generation MCU clocks, embedded-bus transactions, and switching-supply work where the switching frequency stays below ~50 MHz. If your application involves wide-bandgap (GaN\/SiC) gate drives at higher switching frequencies, faster MCU silicon (above ~200 MHz core clock), or DDR-class signal-integrity work, the MSO3034HD (350 MHz) or MSO3054HD (500 MHz) are worth the bandwidth headroom. Memory, sample rate, and the rest of the platform are identical across the family.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Uni-Trend US","offers":[{"title":"181100300079X","offer_id":53265476190432,"sku":"181100300079X","price":2079.2,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/MSO3024HD_1_sq.jpg?v=1782858082"},{"product_id":"mso3034hd-350-mhz-4ch-12-bit-mixed-signal-oscilloscope","title":"MSO3034HD 350 MHz 4Ch 12-Bit Mixed Signal Oscilloscope","description":"\u003ch1\u003eThe MSO3034HD is a 350 MHz, 4-channel mixed signal oscilloscope built on the R12™ native 12-bit ADC architecture, with 2.5 GSa\/s sample rate, 500 Mpts standard memory depth and a calculated rise time of ≤1.00 ns.\u003c\/h1\u003e\n\u003cp\u003eSixteen digital channels are available with the UT-M15 logic probe pod, and Ultra Phosphor 3.0 acquisition delivers 500,000 wfms\/s standard — 1,500,000 wfms\/s in Sequential Mode — on a 10.1-inch capacitive multi-touch display.\u003c\/p\u003e\n\u003cp\u003eFor wide-bandgap power-electronics validation, faster MCU bring-up, and four-channel mixed-signal debug, the MSO3034HD adds bandwidth headroom over the family entry without giving up native 12-bit fidelity. GaN\/SiC gate drives at higher switching frequencies, USB-C power delivery negotiations on faster MCU silicon, and ripple analysis on dense multi-rail boards all stay inside the bandwidth envelope while the 12-bit ADC keeps quantization noise out of the measurement.\u003c\/p\u003e\n\u003cdiv class=\"product-key-features\"\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e350 MHz Bandwidth, 4 Analog Channels\u003c\/strong\u003e — Full 350 MHz on every channel with a calculated rise time of ≤1.00 ns, sized for fast switching nodes and next-edge MCU clocks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eR12™ Native 12-Bit ADC\u003c\/strong\u003e — 4,096 quantization levels held at full bandwidth and full sample rate — no ERES averaging required, no sample-rate trade. Up to 16-bit effective resolution with ERES enabled.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e2.5 GSa\/s Sample Rate, 500 Mpts Memory\u003c\/strong\u003e — Real-time sampling up to 2.5 GSa\/s (interleave) with 500 Mpts maximum storage per channel for long-window capture without sample-rate compromise.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUltra Phosphor 3.0 Acquisition\u003c\/strong\u003e — 500,000 wfms\/s standard capture rate; 1,500,000 wfms\/s in Sequential Mode for trigger-conditioned anomaly hunting. 256-level intensity grading reveals rare events that slower scopes miss.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNine Instruments in One\u003c\/strong\u003e — Oscilloscope, logic analyzer, function\/AWG, spectrum analyzer, digital voltmeter, frequency counter, Bode plot analyzer, protocol analyzer, and power analyzer — integrated into a single bench instrument.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e16 Digital Channels (Optional)\u003c\/strong\u003e — Add the UT-M15 logic probe pod for full mixed-signal debug across analog and digital domains with time-correlated triggering and decoding.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e12 Protocol Decoders\u003c\/strong\u003e — Standard: RS-232\/UART, RS-422\/485, I²C, SPI, CAN. Optional: CAN-FD, LIN, FlexRay, SENT, Audio, MIL-STD-1553B, ARINC 429, Manchester.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e54 Automated Measurements with Statistics\u003c\/strong\u003e — Voltage, time, and frequency-domain measurements with histogram and trend-line display. Up to 27 simultaneous on-screen measurements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptional 50 MHz Dual-Channel AWG\u003c\/strong\u003e — Add a built-in 16-bit dual-channel arbitrary waveform generator with Bode plot loop-stability analysis. Drive stimulus-response testing from the same instrument that captures the response.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e10.1-Inch Multi-Touch Display + WebServer + SCPI\u003c\/strong\u003e — 1280 × 800 capacitive touchscreen with gesture control, browser-based remote access, and full SCPI automation over USB 3.0, LAN, and HDMI export.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eDetailed Features\u003c\/h2\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003ch3\u003eR12™ — Native 12-Bit at Full Bandwidth\u003c\/h3\u003e\n\u003cp\u003eR12™ is UNI-T’s native 12-bit ADC architecture: 4,096 vertical quantization levels at the full 350 MHz bandwidth and 2.5 GSa\/s sample rate, with no ERES averaging and no sample-rate trade. For wide-bandgap power-electronics work where switching transients and rail-noise content compete for the same channel, the 12-bit headroom matters: the µV-scale ripple riding on a 400 V GaN node stays inside the measurement window instead of being lost to 8-bit quantization noise. Enable ERES for further bandwidth-traded enhancement — up to 16-bit effective resolution — when the application can spare the bandwidth.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003e\n\u003cbr\u003eUltra Phosphor 3.0 — 1,500,000 wfms\/s in Sequential Mode\u003c\/h3\u003e\n\u003cp\u003eUltra Phosphor 3.0 is UNI-T’s third-generation waveform-mapping architecture, combining parallel FPGA acquisition with 256-level grayscale intensity grading. Standard waveform capture rate is 500,000 wfms\/s — high enough to surface intermittent timing anomalies on a long capture window. In Sequential Mode — the segmented-memory acquisition mode that conditions captures on a trigger event — capture rate climbs to 1,500,000 wfms\/s, and the scope holds up to 125,000 frames of uninterrupted hardware real-time recording for post-capture replay and analysis. Rare-event hunting on a live system stops being a watch-and-wait exercise and starts being a hunt with the right tool for it.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003ch3\u003eNine Instruments in One — The HD Workhorse\u003c\/h3\u003e\n\u003cp\u003eThe MSO3034HD integrates nine instruments in a single chassis — oscilloscope, 16-channel logic analyzer, 50 MHz dual-channel AWG (optional), 4 Mpts FFT spectrum analyzer, DVM, frequency counter, Bode plot analyzer, protocol analyzer, and power analyzer — with the bandwidth headroom to qualify next-generation switching designs and faster mixed-signal silicon. Bode plots run from the same instrument that captures the loop response, FFT runs on the same channel that captures the time-domain signal, and protocol decoding correlates with the analog rail being measured. The design-validation cycle stays on one bench.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch3\u003e\n\u003cbr\u003eDeep Memory — 500 Mpts Per Channel\u003c\/h3\u003e\n\u003cp\u003e500 Mpts maximum storage depth per channel is the deepest memory in this product class. On a long-window acquisition, the alternative on shallow-memory scopes is the sample-rate trade-off: extend the time base, lose sample rate, lose the high-frequency content that mattered. The MSO3000HD’s memory budget eliminates that trade for capture windows up to 200 ms at the full 2.5 GSa\/s sample rate. Boot-sequence captures on a microcontroller, full power-on transient analysis on a switching converter, multi-frame protocol traces — the memory holds the whole event at full resolution. Selectable depths from 25 kpts up to 500 Mpts let the engineer match memory to workflow without leaving the instrument.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch3\u003e\n\u003cbr\u003e16 Digital Channels with the UT-M15 Logic Probe\u003c\/h3\u003e\n\u003cp\u003e16 digital channels are hardware-standard on the MSO3034HD — the acquisition path, channel-to-channel correlation, and trigger system are all built in. Adding the optional UT-M15 logic probe pod activates the digital input front end. The probe pod uses high 8-bit and low 8-bit signal groupings on a 2.54 mm pin header, with 101 kΩ input impedance and 9.0 pF capacitive loading — light enough not to perturb the DUT, fast enough to resolve 800 ps minimum pulse width at the full 1.25 GSa\/s digital sample rate. Time-correlated triggering across analog and digital channels turns the MSO3034HD into a full mixed-signal debug instrument for embedded systems where the bug lives at the boundary between the firmware and the analog rail.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003e\n\u003cbr\u003e12 Protocol Decoders — 3 Standard, 9 Optional\u003c\/h3\u003e\n\u003cp\u003eTwelve protocol decoders cover embedded, automotive, audio, and aerospace applications. Three are standard: RS-232\/UART, RS-422\/485, I²C, SPI, and CAN ship with the instrument and decode at no additional cost. Nine are field-upgradable license unlocks: CAN-FD, LIN, FlexRay, SENT, Audio, MIL-STD-1553B, ARINC 429, and Manchester — one license per protocol family, no expiration, no subscription. Decoded frames overlay the analog waveform with field-level annotation, and the event list and search functions navigate captured traffic without leaving the instrument. Up to four protocols can decode simultaneously; up to 18 bits of parallel-bus decoding combines analog and digital channels for legacy buses.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003ch3\u003eBuilt-In Spectrum Analyzer — 4 Mpts FFT to 2.5 GHz\u003c\/h3\u003e\n\u003cp\u003eAn enhanced FFT engine of up to 4 Mpts runs as a dedicated frequency-domain analysis mode on the instrument. Frequency range covers 0 to 2.5 GHz, four traces and four detection types (positive peak, negative peak, sample, average) display simultaneously, and the waterfall view tracks spectral content over time for intermittent emissions. Three marker types (auto, manual, threshold) and a marker-point list support EMI pre-screen, harmonic analysis, signal-purity checks, and switching-noise characterization. The same channel that captures the time-domain trace runs the FFT — no signal transfer, no recapture, no de-synchronized traces between two instruments.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003e\n\u003cbr\u003ePower Analysis — Optional 6-Class Suite\u003c\/h3\u003e\n\u003cp\u003eThe optional Power Analysis package adds six classes of power-electronics measurement to the MSO3034HD: switching-loss analysis, output ripple, harmonic analysis, slew rate, modulation analysis, and SOA. For mid-bandwidth GaN\/SiC validation work where the switching node sits in the 50 to 150 MHz envelope, the MSO3034HD’s 350 MHz bandwidth captures the rising edge and the ringing behavior on the same trace the analysis runs against. Switching-loss integration over the full event window is fast and consistent — no exporting to spreadsheet, no script-driven post-processing.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003ch3\u003e54 Automated Measurements with Statistics\u003c\/h3\u003e\n\u003cp\u003e54 automated measurement types cover voltage, time, frequency-domain, and area-under-curve calculations — with up to 27 measurements displayed simultaneously on screen and a 39-item single-channel parameter snapshot for production-style documentation. Histogram and trend-line displays show measurement statistics over time for jitter analysis, drift characterization, and long-window validation runs. Measurements run continuously during acquisition, refresh in real time, and stay correlated with the cursor position when manual analysis takes over.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch3\u003e\n\u003cbr\u003e10.1-Inch Touch UI, WebServer, and SCPI Automation\u003c\/h3\u003e\n\u003cp\u003eThe 10.1-inch capacitive multi-touch display (1280 × 800) supports gesture control — tap, slide, pinch-zoom, drag-and-drop — alongside traditional knob, key, and mouse\/keyboard input. The built-in WebServer exposes the instrument over a browser for cross-platform remote access (PC, tablet, phone), with full waveform export and online user-manual browsing built in. SCPI over USB 3.0 and LAN drops the MSO3034HD into automated bench scripts, and HDMI output mirrors the screen to an external display for teaching, presentation, or large-screen analysis. Mask (template) testing accelerates production go\/no-go cycles in hardware, and the 7-bit precision Autoset uses fuzzy logic to find the right scale and time base across multi-channel inputs in a single button press.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003e\n\u003cbr\u003eApplications\u003c\/h2\u003e\n\u003ch3\u003eR\u0026amp;D and Embedded Engineering\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMixed-signal validation on faster MCUs and FPGA prototypes\u003c\/strong\u003e — 350 MHz bandwidth and 500 Mpts deep memory capture multi-cycle bus transactions on high-speed parallel buses, while four analog channels follow the supply-rail behavior during the same window.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMixed-signal debug across analog and digital domains\u003c\/strong\u003e — with the optional UT-M15 16-channel logic probe pod, the MSO3034HD time-correlates firmware events with analog rails for bug isolation at the boundary.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtocol bring-up and bus traffic analysis\u003c\/strong\u003e — standard RS-232\/UART, I²C, SPI, CAN decoding (plus optional CAN-FD, LIN, FlexRay, etc.) with frame-level annotation on the analog waveform.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLong-window event capture for intermittent bugs\u003c\/strong\u003e — 500 Mpts memory and 125,000-frame Sequential Mode hold the full event window at full sample rate, so the bug doesn’t have to recur during a manual capture window.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePower Electronics\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWide-bandgap gate-drive characterization\u003c\/strong\u003e — 350 MHz bandwidth captures GaN and SiC gate-drive edges and ringing behavior on the same trace the optional Power Analysis package integrates, with the 12-bit ADC keeping the µV-scale ripple on the supply rail measurable.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMI pre-screen on switching converters\u003c\/strong\u003e — 4 Mpts FFT to 2.5 GHz with waterfall display surfaces conducted-emission spurs before the chamber visit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoop-stability validation with optional Bode plot analysis\u003c\/strong\u003e — with the AWG option enabled, drive small-signal injection and measure the closed-loop response from one instrument across 50 Hz to 50 MHz.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMulti-rail correlation\u003c\/strong\u003e — four analog channels capture input, output, reference, and feedback signals on a complex switching topology in a single time-aligned acquisition.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTeaching Labs and Curriculum Use\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMulti-station teaching labs and bench scalability\u003c\/strong\u003e — the WebServer browser interface lets an instructor mirror a single bench’s display to a classroom-wide projection, and SCPI scripting prepares advanced courses for automated-measurement curricula.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVisual demonstration of frequency-domain analysis\u003c\/strong\u003e — the built-in 4 Mpts FFT spectrum analyzer makes time-frequency duality demonstrable on the same instrument students already know.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMixed-signal lab work without a separate logic analyzer\u003c\/strong\u003e — with the optional UT-M15 probe pod, students capture analog and digital signals on one screen for embedded-systems coursework.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRepeatable lab exercises with SCPI automation\u003c\/strong\u003e — instructor-prepared Python scripts drive consistent measurements across student bench stations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBandwidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e350 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChannels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 Analog + 16 Digital (optional UT-M15 probe)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSample Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.5 GSa\/s (interleave) \/ 1.25 GSa\/s (non-interleave)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVertical Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12-bit (up to 16-bit with ERES)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMemory Depth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 Mpts maximum per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCapture Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500,000 wfms\/s standard; 1,500,000 wfms\/s in Sequential Mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCalculated Rise Time (Typ.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤1.00 ns\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBackground Noise (full BW, Typ.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e70 µVrms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10.1 inches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1280 × 800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTouch Screen\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCapacitive multi-touch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrigger Modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEdge, Pulse Width, Video, Slope, Runt, Over-Amplitude, Delay, Timeout, Duration, Setup \u0026amp; Hold, Nth Edge, Pattern, Zone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtocol Decoders — Standard\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRS-232\/UART, RS-422\/485, I²C, SPI, CAN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtocol Decoders — Optional\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCAN-FD, LIN, FlexRay, SENT, Audio, MIL-STD-1553B, ARINC 429, Manchester\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFFT (Spectrum Analyzer)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 4 Mpts; 0 to 2.5 GHz; 4 traces, 4 detections, waterfall\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Analysis (Optional)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 classes: switching loss, ripple, harmonics, slew rate, modulation, SOA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBuilt-In AWG (Optional)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 MHz dual-channel, 16-bit, 250 MSa\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBode Plot (with AWG option)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 Hz to 50 MHz, 1–1000 points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDVM\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4-digit; DC, AC RMS, AC+DC RMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency Counter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7-digit hardware\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAutomated Measurements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e54 types; up to 27 simultaneous on-screen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSequential Mode Frames\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 125,000 frames\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSB 3.0 Host, USB Device, LAN, HDMI, AUX (Trig Out \/ Pass-Fail \/ DVM), Gen Out × 2, 10 MHz In\/Out, EXT Trig\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRemote Control\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWebServer (browser-based), SCPI over USB \/ LAN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCE, cETLus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4\u003eDownloads\u003c\/h4\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cbr\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cstrong\u003e\u003ca rel=\"noopener\" title=\"MSO3000 Series Datasheet\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/MSO3000HD_-_Data_Sheet_-_V1.2.pdf\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/pdf-icon-63x63_480x480.png\" style=\"float: left;\" alt=\"PDF\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/850009-i.pdf\" target=\"_blank\"\u003e\u003cbr\u003e\u003c\/a\u003e\u003ca rel=\"noopener\" title=\"UNI-T MSO3000 Series Datasheet\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/MSO3000HD_-_Data_Sheet_-_V1.2.pdf\" target=\"_blank\"\u003eUNI-T MSO3000 Series Datasheet\u003c\/a\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cbr\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cstrong\u003e\u003ca rel=\"noopener\" title=\"UNI-T MSO3000 Series Users Manual\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/MSO3000HD_-_User_Manual_-_V1.2.pdf\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/pdf-icon-63x63_480x480.png\" style=\"float: left;\" alt=\"PDF\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/850009-i.pdf\" target=\"_blank\"\u003e\u003cbr\u003e\u003c\/a\u003e\u003ca rel=\"noopener\" title=\"UN I-T MSO3000 Series Users Manual\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/MSO3000HD_-_User_Manual_-_V1.2.pdf\" target=\"_blank\"\u003eUNI-T MSO3000 Series Users Manual\u003c\/a\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eOptions \u0026amp; Accessories\u003c\/h4\u003e\n\u003ch3\u003eIncluded\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMSO3034HD mixed signal oscilloscope\u003c\/li\u003e\n\u003cli\u003e4 × UT-P05 100 MHz, 10:1\/1:1 passive probes (200 MHz family) or UT-P06 200 MHz, 10:1\/1:1 passive probes (350\/500 MHz family)\u003c\/li\u003e\n\u003cli\u003eAC power cord (region-specific)\u003c\/li\u003e\n\u003cli\u003eUSB cable, certificate of conformity, quick start guide\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eRecommended Accessories\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUT-M15 16-channel logic analyzer probe pod — activates the 16 standard digital channels for mixed-signal debug.\u003c\/li\u003e\n\u003cli\u003eUT-P series passive, differential, and current probes — matched probes for high-voltage, high-current, and differential measurements.\u003c\/li\u003e\n\u003cli\u003eOptional protocol decode licenses (CAN-FD, LIN, FlexRay, SENT, Audio, MIL-STD-1553B, ARINC 429, Manchester) — field-upgradable, no expiration.\u003c\/li\u003e\n\u003cli\u003eOptional 50 MHz dual-channel AWG license — adds stimulus-response and Bode plot capability to the same instrument.\u003c\/li\u003e\n\u003cli\u003eOptional Power Analysis package — six-class power-electronics measurement suite.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSoftware Options\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMSO3000HD-ARINC429 — Aerospace ARINC429 Serial Bus Trigger and Analysis\u003c\/li\u003e\n\u003cli\u003eMSO3000HD-AUDIO — Serial Bus Trigger and Analysis Option (I2S, LJ, RJ, TDM)\u003c\/li\u003e\n\u003cli\u003eMSO3000HD-AUTO — Serial Bus Trigger and Decode Bundle (CAN, CAN-FD, LIN, FlexRay, SENT)\u003c\/li\u003e\n\u003cli\u003eMSO3000HD-AWG — Arbitrary Waveform Generator option\u003c\/li\u003e\n\u003cli\u003eMSO3000HD-BND — Serial Bus Trigger and Decode Bundle (incl. AUTO, AUDIO, MIL-STD, ARINC429, MANCH)\u003c\/li\u003e\n\u003cli\u003eMSO3000HD-BW2MT3M5 — 350MHz Bandwidth Upgrade\u003c\/li\u003e\n\u003cli\u003eMSO3000HD-CAN — Automotive CAN Serial Bus Trigger and Analysis\u003c\/li\u003e\n\u003cli\u003eMSO3000HD-CANFD — Automotive CAN-FD Serial Bus Trigger and Analysis\u003c\/li\u003e\n\u003cli\u003eMSO3000HD-FLEX — Automotive FlexRay Serial Bus Trigger and Analysis\u003c\/li\u003e\n\u003cli\u003eMSO3000HD-LIN — Automotive LIN Serial Bus Trigger and Analysis\u003c\/li\u003e\n\u003cli\u003eMSO3000HD-MANCH — Manchester Serial Bus Trigger and Analysis Option\u003c\/li\u003e\n\u003cli\u003eMSO3000HD-MIL1553 — MIL-STD-1553 Serial Bus Trigger and Analysis Option\u003c\/li\u003e\n\u003cli\u003eMSO3000HD-PWR — Power Analysis Option\u003c\/li\u003e\n\u003cli\u003eMSO3000HD-SENT — Automotive SENT Sensor Bus Trigger and Analysis\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFamily Members\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMSO3054HD — 500 MHz, 4ch — full family flagship with the lowest noise floor\u003c\/li\u003e\n\u003cli\u003eMSO3024HD — 200 MHz, 4ch — same family at the entry price\u003c\/li\u003e\n\u003cli\u003eMSO3354E — 350 MHz, 4ch legacy 8-bit MSO — predecessor reference\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch4\u003eFAQ's\u003c\/h4\u003e\n\u003ch3\u003eWhat protocols are included standard, and what are optional?\u003c\/h3\u003e\n\u003cp\u003eStandard decoders: RS-232\/UART, RS-422\/485, I²C, SPI, and CAN. Optional license unlocks: CAN-FD, LIN, FlexRay, SENT, Audio, MIL-STD-1553B, ARINC 429, and Manchester. Optional licenses do not expire; firmware updates are free over the product’s lifetime.\u003c\/p\u003e\n\u003ch3\u003eWhat does R12™ mean in practice?\u003c\/h3\u003e\n\u003cp\u003eR12™ is UNI-T’s native 12-bit ADC architecture — 4,096 vertical quantization levels, sixteen times the resolution of an 8-bit ADC, held at the full bandwidth and sample rate with no ERES averaging required. ERES is available as an enhancement on top of R12 (up to 16-bit effective resolution); on competing scopes, ERES is required to claim 12-bit at all and trades bandwidth or sample rate to do it.\u003c\/p\u003e\n\u003ch3\u003eCan I add the AWG and logic-analyzer capabilities later?\u003c\/h3\u003e\n\u003cp\u003eYes. The 16-channel logic analyzer is hardware-standard; activating it requires the optional UT-M15 logic probe pod. The 50 MHz dual-channel AWG (with Bode plot) is a license unlock. Both are field-upgradable on instruments already in service. License unlocks do not expire.\u003c\/p\u003e\n\u003ch3\u003eWhat’s the difference between the standard 500,000 wfms\/s and Sequential Mode’s 1,500,000 wfms\/s?\u003c\/h3\u003e\n\u003cp\u003e500,000 wfms\/s is the continuous capture rate the instrument sustains across normal operation. Sequential Mode is a segmented-memory acquisition mode that conditions captures on a trigger event and uses the memory budget to record up to 125,000 frames of trigger-aligned waveforms back-to-back; the 1,500,000 wfms\/s figure is the effective capture rate during Sequential Mode operation. Sequential Mode is the right tool for hunting rare or intermittent events; the standard mode is the right tool for continuous monitoring.\u003c\/p\u003e\n\u003ch3\u003eWhen should I choose the MSO3034HD over the MSO3024HD or MSO3054HD?\u003c\/h3\u003e\n\u003cp\u003eThe MSO3034HD is the mid-tier of the family. Choose it over the MSO3024HD when your work involves GaN\/SiC switching nodes, faster MCU silicon, or higher-speed mixed-signal validation that needs the 350 MHz envelope. Choose it over the MSO3054HD when 500 MHz is more headroom than your application requires — the MSO3034HD hits the same noise floor and the same 12-bit native resolution as the flagship at lower bandwidth, with budget redirected toward probes, software, or a second instrument.\u003c\/p\u003e\n\u003ch4\u003eVideos\u003c\/h4\u003e\n\u003cp\u003e\u003ciframe title=\"YouTube video player\" src=\"https:\/\/www.youtube.com\/embed\/cV9Jh-qsuPI?si=y1nCrbHmS-M7_Kni\" height=\"315\" width=\"560\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Uni-Trend US","offers":[{"title":"181100300081X","offer_id":53265476223200,"sku":"181100300081X","price":2399.2,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/MSO3034HD_1_sq.jpg?v=1782858082"},{"product_id":"mso5054hd-500-mhz-4ch-12-bit-mixed-signal-oscilloscope","title":"MSO5054HD 500 MHz 4Ch 12-Bit Mixed Signal Oscilloscope","description":"\u003ch1\u003eThe MSO5054HD is a 500 MHz, 4-channel mixed signal oscilloscope built on UNI-T’s R12™ native 12-bit ADC architecture, with a 5 GSa\/s real-time sample rate (interleave mode), 500 Mpts standard memory depth, and a calculated rise time of ≤0.70 ns. \u003c\/h1\u003e\n\u003cp\u003eThe 12-bit resolution holds at the full 500 MHz bandwidth with no ERES averaging step or sample-rate trade-off, and Ultra Phosphor 3.0 acquisition delivers up to 800,000 wfms\/s standard — 1,500,000 wfms\/s in Sequential Mode. Sixteen digital channels are available with the UT-M15 logic probe pod, on a 10.1-inch capacitive multi-touch display.\u003c\/p\u003e\n\u003cp\u003eFor wide-bandgap power-electronics validation at higher switching frequencies, multi-channel power-supply characterization, and four-channel mixed-signal work on faster MCU and FPGA silicon, the MSO5054HD adds 150 MHz of bandwidth headroom over the family entry while preserving the same native 12-bit ADC, 5 GSa\/s sample rate, and 500 Mpts memory. Calculated rise time falls to ≤0.70 ns — fast enough to capture GaN gate-edge transitions at scale — and the nine-instrument platform stays intact across the upgrade.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e500 MHz Bandwidth, 4 Channels\u003c\/strong\u003e — 4-channel analog capture with 5 GSa\/s sample rate and 12-bit native vertical resolution, scaling to 16-bit with ERES.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e500 Mpts Memory Depth\u003c\/strong\u003e — Deep memory for extended captures without sample-rate trade-off; navigation and search across the full memory window.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e800,000 wfms\/s Standard, 1.5 M in Sequential Mode\u003c\/strong\u003e — Ultra Phosphor 3.0 intensity-graded display with 256 grayscale levels for rare-event hunting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eR12™ Native 12-Bit ADC\u003c\/strong\u003e — 4,096 vertical levels at full bandwidth, sixteen times the resolution of a conventional 8-bit oscilloscope.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSix Protocols Standard, Nine Optional\u003c\/strong\u003e — RS-232\/UART, I²C, SPI, CAN, LIN included; CAN-FD, CAN-XL, FlexRay, SENT, Audio, MIL-STD-1553B, ARINC 429, Manchester, 1-Wire, and I3C optional.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuilt-in 2.5 GHz Spectrum Analyzer\u003c\/strong\u003e — Enhanced FFT up to 4 Mpts, four traces and four detections, waterfall display.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptional 50 MHz Dual-Channel AWG\u003c\/strong\u003e — Built-in arbitrary waveform generator pairs with the optional Bode plot analyzer for closed-loop frequency-response measurement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptional Power Analysis Suite\u003c\/strong\u003e — Switching loss, harmonic analysis, SOA, R\u003csub\u003eDS(on)\u003c\/sub\u003e, modulation, slew rate, ripple analysis, and more.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e16 Digital Channels with UT-M15\u003c\/strong\u003e — Add the UT-M15 logic probe pod for time-correlated mixed-signal debug.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e56 Automated Measurements with Histogram and Trend\u003c\/strong\u003e — 27 measurements simultaneously displayed; 39-item single-channel parameter snapshot.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e10.1-Inch Capacitive Touchscreen\u003c\/strong\u003e — 1280×800 HD multi-touch with gesture support; full-SCPI WebServer for browser-based remote control.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eDetailed Features\u003c\/h2\u003e\n\u003ch3\u003eR12™ — Native 12-Bit at Full Bandwidth\u003c\/h3\u003e\n\u003cp\u003eR12™ is UNI-T’s native 12-bit ADC architecture: 4,096 vertical quantization levels — sixteen times the resolution of a conventional 8-bit oscilloscope — held at the full 500 MHz bandwidth and 5 GSa\/s sample rate, with no ERES averaging step and no sample-rate trade-off to get there. ERES (enhanced resolution) extends effective vertical resolution up to 16-bit when bandwidth headroom is available, but the baseline 12-bit performance is the front-end’s native characteristic, not a software boost. For low-amplitude signal work — switching ripple riding on a busy DC rail, sensor-bridge outputs into a noisy ADC, jitter analysis on a clock line — the difference between 8-bit quantization steps showing through the measurement and 12-bit fidelity disappearing them is the difference between a usable capture and a noisy one.\u003c\/p\u003e\n\u003ch3\u003eUltra Phosphor 3.0 — 800,000 wfms\/s, 1.5 M in Sequential Mode\u003c\/h3\u003e\n\u003cp\u003eUltra Phosphor 3.0 is UNI-T’s third-generation waveform-mapping architecture, combining parallel FPGA acquisition with 256-level grayscale intensity grading. Standard waveform capture rate is up to 800,000 wfms\/s — high enough to surface intermittent timing anomalies on a long capture window without missing them between screen redraws. In Sequential Mode — the segmented-memory acquisition mode that conditions captures on a trigger event — capture rate climbs to 1,500,000 wfms\/s, and the scope holds up to 400,000 frames of uninterrupted hardware real-time recording for post-capture replay and analysis. Rare-event hunting on a live system stops being a watch-and-wait exercise and starts being an analysis-after-capture exercise.\u003c\/p\u003e\n\u003ch3\u003eNine Instruments in One — The HD Workhorse Platform\u003c\/h3\u003e\n\u003cp\u003eThe MSO5000HD platform integrates nine instrument functions into one bench unit: digital storage oscilloscope, 16-channel logic analyzer (with the optional UT-M15 probe pod), 50 MHz dual-channel function and arbitrary waveform generator (optional), 2.5 GHz spectrum analyzer, 4-digit digital voltmeter, 7-digit hardware frequency counter, multi-protocol serial-bus analyzer, Bode plot analyzer (optional, paired with the AWG for closed-loop sweep), and power-electronics analyzer (optional). For small-lab consolidation and education-track lab benches, the integration replaces three to five separate instruments with one instrument footprint, one calibration chain, and one operator-training surface\u003c\/p\u003e\n\u003ch3\u003e16 Digital Channels with the UT-M15 Probe Pod (Optional)\u003c\/h3\u003e\n\u003cp\u003eMixed-signal capability is hardware-standard in the MSO5000HD chassis — the 16-digital-channel logic-analyzer front end is built in. Adding the digital channels requires the optional UT-M15 logic probe pod, which provides separate high 8-bit and low 8-bit connections and connects directly to 8×2 square pins (2.54 mm) for fast attachment to development boards. Maximum digital sample rate is 1.25 GSa\/s with a minimum detectable pulse width of 800 ps, and threshold selection covers TTL, 5.0 V\/3.3 V\/2.5 V\/1.8 V CMOS, ECL, PECL, LVDS, and a custom level — covering essentially every common digital interface voltage on modern hardware. Digital and analog channels share the same time base, the same trigger system, and the same display, so a falling SPI clock edge and the analog-domain crosstalk it causes show up in the same frame.\u003c\/p\u003e\n\u003ch3\u003e15 Protocol Decoders — 6 Standard, 9 Optional\u003c\/h3\u003e\n\u003cp\u003eSix protocols decode standard with the MSO5000HD: RS-232\/422\/485\/UART, I²C, SPI, CAN, and LIN. Nine additional protocols are available as separately licensed options: CAN-FD, CAN-XL, FlexRay, SENT, Audio (I²S\/LJ\/RJ\/TDM), MIL-STD-1553B, ARINC 429, Manchester, 1-Wire, and I3C. The decoder runs on dedicated decode hardware, not a software post-processing path, so decode results display in real time during acquisition rather than after-the-fact on saved data — the difference between “debug a protocol stack interactively” and “capture, save, transfer, open in a separate tool, decode.” Trigger-and-decode operates pause-and-record modes for both interactive bring-up and unattended logging, and the event list plus search function lets you jump to a specific framed event across a 500 Mpt capture.\u003c\/p\u003e\n\u003ch3\u003eBuilt-In Spectrum Analyzer — 4 Mpts FFT to 2.5 GHz\u003c\/h3\u003e\n\u003cp\u003eThe MSO5000HD’s built-in spectrum analyzer leverages the 5 GSa\/s sample rate for a 0–2.5 GHz frequency range — useful for characterizing wideband signals, identifying spurious emissions, and verifying clock harmonics at frequencies beyond what 2.5 GSa\/s instruments can analyze. Enhanced FFT supports up to 4 Mpts with 4-channel parallel signal analysis, four traces and four detections, auto\/manual\/threshold marker types, marker point lists, and a waterfall-curve display mode for time-evolving spectra. For pre-compliance EMI screening, switching-supply noise hunting, and clock-quality verification, the integrated spectrum analyzer means one instrument covers both time-domain and frequency-domain measurement needs.\u003c\/p\u003e\n\u003ch3\u003ePower Analysis — Optional Multi-Class Suite\u003c\/h3\u003e\n\u003cdiv\u003eThe optional power-analysis package adds nine classes of power-electronics measurement to the MSO5000HD: power quality, surge current, safe operating area (SOA), harmonic analysis, R\u003csub\u003eDS(on)\u003c\/sub\u003e measurement, modulation analysis, switching-loss analysis, slew rate, and ripple analysis — with transient-response and power-efficiency measurements added in firmware updates. For early-stage power-converter design, the package replaces a separate power-analyzer instrument: the same scope that captures the gate-drive waveform calculates the switching loss across the cycle, and the same FFT mode that screens for spurs computes the harmonic spectrum on the AC input.\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\nConnect a voltage probe and a current probe, select the analysis type, and the calculations run on-instrument — no post-processing workflow, no separate software tool.500 Mpts of acquisition memory standard, with adjustable depths from Auto (5 Mpts) through 25 kpts, 250 kpts, 500 kpts, 5 Mpts, 50 Mpts, 100 Mpts, and 500 Mpts. Deep memory matters when the acquisition window is long — minutes-long captures looking for an intermittent fault, multi-frame protocol traces across a power-on sequence, or extended ripple analysis across a load-step transient — because the sample rate stays at 5 GSa\/s for far longer than a shallow-memory scope before forcing a sample-rate trade-off. Combined with the navigation-and-search function (event, time, and marker navigation modes), the deep memory is searchable: zoom into a specific glitch in a 500 Mpt capture without scrolling through the rest.\n\u003ch3\u003e\n\u003cbr\u003e56 Automated Measurements with Histogram and Trend Statistics\u003c\/h3\u003e\n\u003cp\u003e56 automated measurement types cover voltage, time, frequency-domain, and area-under-curve calculations — with up to 27 measurements displayed simultaneously on screen and a 39-item single-channel parameter snapshot for production-style documentation. Histogram and trend-line displays show measurement statistics over time, useful for signal-integrity work where the parameter distribution matters as much as a single instantaneous value. The new top-and-bottom amplitude calculation strategy and the burst-region measurement function add capability for non-stationary signals where the measurement window has to be localized to a specific event rather than averaged across the full capture\u003c\/p\u003e\n\u003ch3\u003eTiming Analyzer — Bus Timing Conformance Testing\u003c\/h3\u003e\n\u003cp\u003eThe timing analyzer function performs conformance-grade timing measurements on serial bus signals: pulse width, amplitude, edge characteristics, setup time, and hold time on I²C, SPI, CAN, and I²S buses. For consumer-electronics manufacturing — mobile phones, smart wearables, home appliances, multimedia audio-video equipment, and automotive electronics — bus-timing consistency is the difference between a board that passes audit and one that fails customer qualification. The MSO5000HD generates exportable conformance test reports, turning the scope into a documentation tool for design verification and test-lab compliance work.\u003c\/p\u003e\n\u003ch3\u003e10.1-Inch Touch UI, WebServer, and SCPI Automation\u003c\/h3\u003e\n\u003cp\u003eA 10.1-inch 1280×800 capacitive multi-touch display anchors the front-panel experience — touch, drag, pinch-to-zoom, and rectangle-drawing gestures for common waveform operations — while preserving the traditional knob-and-key controls that bench engineers want for fine adjustment. Mouse and keyboard are supported as additional input methods. For automation, the built-in WebServer provides browser-based instrument control over the network — SCPI commands, waveform export, and online user-manual access — from PC or mobile devices, and full SCPI compliance over LAN or USB Device enables programmatic control from LabVIEW, Python, or any SCPI-aware test framework. UNI-T’s free instrument manager runs on the PC side for graphical control without writing custom automation code.\u003c\/p\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003ch3\u003eR\u0026amp;D and Embedded Validation\u003c\/h3\u003e\n\u003cp\u003eFor R\u0026amp;D validation at the 500 MHz bandwidth tier, the MSO5054HD delivers fast-edge capture and four-channel timing-correlated analog plus digital views (with the UT-M15 logic probe pod) on faster ARM and RISC-V silicon, PCIe Gen2 reference clocks, and high-speed serial peripherals where 350 MHz starts to limit visibility into rise-time and overshoot detail.\u003c\/p\u003e\n\u003ch3\u003ePower Electronics Design and Validation\u003c\/h3\u003e\n\u003cp\u003eFor GaN\/SiC power-stage validation, the 500 MHz bandwidth and ≤0.70 ns rise time capture switching-edge detail at frequencies where slower scopes start to round corners — useful for switching-loss measurement, EMI root-cause work, and gate-driver characterization on dense converter boards.\u003c\/p\u003e\n\u003ch3\u003eTest Laboratory and Consultancy Work\u003c\/h3\u003e\n\u003cp\u003eFor external test-lab work characterizing customer-supplied DUTs across mixed power and signal-integrity scopes, the MSO5054HD’s 12-bit acquisition plus 2.5 GHz spectrum analyzer plus optional Bode plot bring three classes of measurement under one instrument cover for compact bench setups.\u003c\/p\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAnalog Bandwidth (50 Ω, −3 dB)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAnalog Bandwidth (1 MΩ, −3 dB)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChannels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 Analog + 16 Digital (with optional UT-M15 probe pod)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReal-Time Sample Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 GSa\/s (interleave mode) \/ 2.5 GSa\/s (non-interleave mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDigital Channel Sample Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.25 GSa\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVertical Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12-bit native (up to 16-bit with ERES)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMemory Depth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 Mpts maximum per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCapture Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800,000 wfms\/s standard; 1,500,000 wfms\/s in Sequential Mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCalculated Rise Time (10–90%, Typ.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤0.70 ns\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBackground Noise (full BW, Typ.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e75 µVrms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10.1 inches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1280 × 800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTouch Screen\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCapacitive multi-touch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSequential Sampling\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMaximum 400,000 frames; minimum two trigger intervals \u0026lt; 700 ns\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHardware Real-Time Waveform Recording\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400,000 frames\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrigger Modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 types: edge, pulse width, video, ramp, runt, over-amplitude, delay, timeout, duration, setup \u0026amp; hold, Nth edge, code pattern; Zone trigger\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtocol Triggering and Decoding\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 protocols total. \u003cstrong\u003eStandard:\u003c\/strong\u003e RS-232\/422\/485\/UART, I²C, SPI, CAN, LIN. \u003cstrong\u003eOptional:\u003c\/strong\u003e CAN-FD, CAN-XL, FlexRay, SENT, Audio, MIL-STD-1553B, ARINC 429, Manchester, 1-Wire, I3C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSpectrum Analyzer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0–2.5 GHz, enhanced FFT up to 4 Mpts, 4-channel parallel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBuilt-in AWG (Optional)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 MHz equivalent, dual-channel, 312.5 MSa\/s, 16-bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBode Plot Analyzer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOptional — frequency response, loop stability, filter, amplifier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Analyzer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOptional — switching loss, harmonics, ripple, slew rate, R\u003csub\u003eDS(on)\u003c\/sub\u003e, SOA, modulation, transient response, power efficiency\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAutomated Measurements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e56 types; up to 27 simultaneous; histogram and trend display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Input Voltage (1 MΩ)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400 V (DC + AC\u003csub\u003eVpk\u003c\/sub\u003e); 135 V\u003csub\u003eRMS\u003c\/sub\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Input Voltage (50 Ω)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 V\u003csub\u003eRMS\u003c\/sub\u003e max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnectivity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSB Host\/Device, LAN, EXT Trig, AUX Out (Trig Out \/ Pass-Fail \/ DVM), Gen Out, HDMI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRemote Control\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSCPI over LAN\/USB; built-in WebServer (browser, PC + mobile); UNI-T Instrument Manager\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRoHS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003eDownloads\u003c\/h4\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cbr\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/MSO5000HD_Series_-_Data_Sheet.pdf\" title=\"MSO5000 Series Datasheet\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/pdf-icon-63x63_480x480.png\" style=\"float: left;\" alt=\"PDF\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/850009-i.pdf\" target=\"_blank\"\u003e\u003cbr\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/MSO5000HD_Series_-_Data_Sheet.pdf\"\u003eUNI-T MSO5000 Series Datasheet\u003c\/a\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cbr\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/MSO5000HD_Series_User_Manual.pdf\" title=\"UNI-T MSO5000 Series Users Manual\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/pdf-icon-63x63_480x480.png\" style=\"float: left;\" alt=\"PDF\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/850009-i.pdf\" target=\"_blank\"\u003e\u003cbr\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/MSO5000HD_Series_User_Manual.pdf\" title=\"UNI-T MSO5000 Series Users Manual\" rel=\"noopener\" target=\"_blank\"\u003eUNI-T MSO5000 Series Users Manual\u003c\/a\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eFAQ's\u003c\/h4\u003e\n\u003ch3\u003eWhat protocols are included with the MSO5000HD as standard?\u003c\/h3\u003e\n\u003cp\u003eRS-232\/422\/485, UART, I²C, SPI, CAN, and LIN are decoded standard with no additional license required. CAN-FD, CAN-XL, FlexRay, SENT, Audio (I²S\/LJ\/RJ\/TDM), MIL-STD-1553B, ARINC 429, Manchester, 1-Wire, and I3C are available as separately licensed options — activated on the same instrument with no firmware upgrade or reflash required.\u003c\/p\u003e\n\u003ch3\u003eWhat is the practical advantage of 12-bit native resolution over 8-bit?\u003c\/h3\u003e\n\u003cp\u003eA 12-bit ADC provides 4,096 vertical quantization levels compared to 256 for an 8-bit scope — sixteen times the resolution. In low-amplitude work (switching ripple riding on a DC rail, sensor outputs from a strain gauge, jitter on a clock line, or any signal where the amplitude of interest is much smaller than the channel’s full-scale range), 8-bit quantization steps show up as visible stair-stepping in the captured waveform. 12-bit acquisition keeps those steps below the front-end’s noise floor, so what you’re looking at on screen is the signal, not the digitization grid.\u003c\/p\u003e\n\u003ch3\u003eHow do I add 16 digital channels for mixed-signal work?\u003c\/h3\u003e\n\u003cp\u003eThe 16-digital-channel logic-analyzer front end is built into every MSO5000HD chassis as hardware-standard. To use it, add the optional UT-M15 logic probe pod, which provides separate high 8-bit and low 8-bit pin connections and attaches directly to standard 2.54 mm 8×2 square-pin headers on development boards. Maximum digital sample rate is 1.25 GSa\/s with an 800 ps minimum detectable pulse width.\u003c\/p\u003e\n\u003ch3\u003eWhat is the difference between Ultra Phosphor 3.0’s 800,000 wfms\/s standard rate and the 1,500,000 wfms\/s sequential-mode rate?\u003c\/h3\u003e\n\u003cp\u003eThe 800,000 wfms\/s rate is the continuous waveform-capture rate during normal acquisition — the rate at which the scope acquires, processes, and displays new waveforms back-to-back during live operation. The 1,500,000 wfms\/s sequential-mode rate applies in segmented-memory acquisition where the scope captures only a short window around each trigger event, then re-arms quickly for the next trigger; this maximizes capture density when chasing intermittent events at the cost of dead time between captures. In practical terms: continuous 800K for general-purpose acquisition, sequential 1.5M for rare-event hunting on a triggered signal.\u003c\/p\u003e\n\u003ch3\u003eIs the AWG (arbitrary waveform generator) included or optional?\u003c\/h3\u003e\n\u003cp\u003eThe AWG hardware is built into every MSO5000HD chassis as hardware-standard, but activation requires the AWG software license. Once activated, it provides dual-channel 50 MHz output with sine, square, pulse, ramp, arbitrary, noise, and DC waveforms; AM, FM, ASK, FSK, and sweep modulation; and the ability to load on-screen captured waveforms back to the Gen output for replay-style stimulus testing. The optional Bode plot analyzer pairs with the AWG for closed-loop frequency-response measurement.\u003c\/p\u003e\n\u003ch3\u003eCan I control the MSO5000HD remotely without installing local software?\u003c\/h3\u003e\n\u003cp\u003eYes. The built-in WebServer provides full instrument control through any standard web browser on a PC, tablet, or mobile device on the same network — no client install, no driver download. Common operations (waveform capture, screenshot, parameter readback, settings changes, file export) work directly through the browser. For programmatic control, the same interface accepts SCPI commands over LAN or USB, compatible with LabVIEW, Python, MATLAB, and any SCPI-aware automation framework. UNI-T also provides a free instrument-manager application for users who prefer a graphical desktop client.\u003c\/p\u003e\n\u003ch4\u003eOptions \u0026amp; Accessories\u003c\/h4\u003e\n\u003ch3\u003eIncluded\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePower cord\u003c\/li\u003e\n\u003cli\u003eUSB3.0 printing cable\u003c\/li\u003e\n\u003cli\u003eEnglish download guide\u003c\/li\u003e\n\u003cli\u003emulti-language safety manual\u003c\/li\u003e\n\u003cli\u003ecalibration report (COC)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eRecommended Add-Ons\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUT-M15 Logic Probe Pod — adds 16 digital channels with high\/low 8-bit connectors and direct 8×2 square-pin attachment.\u003c\/li\u003e\n\u003cli\u003eActive probes — for 50 Ω high-bandwidth signal-integrity work where a passive 10x probe limits visibility.\u003c\/li\u003e\n\u003cli\u003eCurrent probe(s) — for power-electronics work paired with the optional power-analysis suite; voltage and current probe simultaneously for switching-loss measurement.\u003c\/li\u003e\n\u003cli\u003eAWG license — activates the dual-channel 50 MHz arbitrary waveform generator hardware in the chassis.\u003c\/li\u003e\n\u003cli\u003eBode plot license — pairs with the AWG for closed-loop frequency-response sweep on amplifiers, filters, and power-supply control loops.\u003c\/li\u003e\n\u003cli\u003ePower analysis license — activates the multi-class power-electronics measurement suite.\u003c\/li\u003e\n\u003cli\u003eProtocol decoder licenses — CAN-FD, CAN-XL, FlexRay, SENT, Audio, MIL-STD-1553B, ARINC 429, Manchester, 1-Wire, I3C, available individually.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSoftware Options\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMSO5000HD-1WIRE — 1-Wire Serial Bus Trigger and Analysis Option\u003c\/li\u003e\n\u003cli\u003eMSO5000HD-ARINC429 — Aerospace ARINC429 Serial Bus Trigger and Analysis\u003c\/li\u003e\n\u003cli\u003eMSO5000HD-AUDIO — Audio Serial Bus Trigger and Analysis\u003c\/li\u003e\n\u003cli\u003eMSO5000HD-AUTO — Automotive Serial Bus Trigger and Analysis Option\u003c\/li\u003e\n\u003cli\u003eMSO5000HD-AWG — 50 MHz 2Ch Arbitrary Waveform Generator with Bode Plot\u003c\/li\u003e\n\u003cli\u003eMSO5000HD-BND — Complete Serial Analysis Bundle\u003c\/li\u003e\n\u003cli\u003eMSO5000HD-BW3M5T1G — 1GHz bandwidth upgrade\u003c\/li\u003e\n\u003cli\u003eMSO5000HD-BW5MT1G — 1GHz bandwidth upgrade\u003c\/li\u003e\n\u003cli\u003eMSO5000HD-CANFD — Automotive CAN-FD Serial Bus Trigger and Analysis\u003c\/li\u003e\n\u003cli\u003eMSO5000HD-CANXL — Automotive CAN-XL Serial Bus Trigger and Analysis\u003c\/li\u003e\n\u003cli\u003eMSO5000HD-FLEX — Automotive FlexRay Serial Bus Trigger and Analysis\u003c\/li\u003e\n\u003cli\u003eMSO5000HD-I3C — Embedded Systems I3C Serial Bus Trigger and Analysis\u003c\/li\u003e\n\u003cli\u003eMSO5000HD-MANCH — Manchester Serial Bus Trigger and Analysis Option\u003c\/li\u003e\n\u003cli\u003eMSO5000HD-MIL1553 — MIL-STD-1553 Serial Bus Trigger and Analysis Option\u003c\/li\u003e\n\u003cli\u003eMSO5000HD-PWR — Advanced Power Analysis\u003c\/li\u003e\n\u003cli\u003eMSO5000HD-SENT — Automotive SENT Serial Bus Trigger and Analysis\u003c\/li\u003e\n\u003cli\u003eMSO5000HD-TIMING — Advanced Timing Analysis\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eVideos\u003c\/h4\u003e\n\u003cp\u003e\u003ciframe title=\"YouTube video player\" src=\"https:\/\/www.youtube.com\/embed\/uxqJIwhyzmU?si=qQ-8dIBYZfgtv6cA\" height=\"315\" width=\"560\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Uni-Trend US","offers":[{"title":"Default Title","offer_id":53265476255968,"sku":"181100300115X","price":3994.15,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/mso5054hd-500-mhz-4ch-12-bit-mixed-signal-oscilloscope-181100300115x-1083288.png?v=1782890831"},{"product_id":"upo1104-100-mhz-4ch-digital-storage-oscilloscope","title":"UPO1104 100 MHz 4Ch Digital Storage Oscilloscope","description":"\u003ch1\u003eThe UNI-T UPO1104 is a 100 MHz, four-channel digital storage oscilloscope with 2 GSa\/s real-time sample rate, 56 Mpts memory depth, and a 500,000 wfms\/s waveform capture rate (Fast Acquire mode).\u003c\/h1\u003e\n\u003cp\u003eUltra Phosphor 2.0 display technology drives 256-level intensity grading on a 7-inch WVGA TFT LCD, making it straightforward to distinguish frequent signal behavior from rare anomalies at a glance. Four channels, 56 Mpts of memory, an independent DVM module, an enhanced 1 Mpts FFT, and three serial bus protocols decoded as standard — features that typically migrate to mid-tier scopes. The UPO1104 keeps them on the value-tier bench, which is the value proposition for teaching labs running twenty stations and engineering teams sourcing a second scope without sacrificing capability.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e100 MHz bandwidth, 4 channels\u003c\/strong\u003e — 2 GSa\/s real-time sample rate (2 GSa\/s on a single channel; 1 GSa\/s on two; 500 MSa\/s on all four), ≤ 3.5 ns calculated rise time.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e56 Mpts memory depth\u003c\/strong\u003e — capture full switching cycles and long protocol sequences without trading sample rate for record length.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e500,000 wfms\/s waveform capture rate\u003c\/strong\u003e — Ultra Phosphor 2.0 with 256-level intensity grading, in Fast Acquire mode. Fast enough to surface intermittent events that slower scopes spend hours missing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e1 Mpts enhanced FFT\u003c\/strong\u003e — frequency-domain analysis with frequency setting, demodulation mode, waterfall display, and marker measurement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndependent DVM module\u003c\/strong\u003e — dedicated AC\/DC True RMS digital voltmeter, operating in parallel with scope acquisition.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e7-digit hardware frequency counter\u003c\/strong\u003e — hardware-accelerated counter alongside the scope channels.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e3 serial bus decoders standard\u003c\/strong\u003e — RS-232\/UART, I²C, and SPI trigger and decode included; full-memory hardware decoding turns multi-second decode times into milliseconds.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e36 automated measurements\u003c\/strong\u003e — time, voltage, frequency, and statistical measurements with cursor-area scoping.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMultiple trigger types\u003c\/strong\u003e — edge, pulse width, video, slope, runt, over-amplitude, delay, timeout, duration, setup\/hold, Nth edge, and pattern triggers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeb remote control\u003c\/strong\u003e — browser-based access from any PC or mobile device on the LAN; no driver software, no host application.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCPI + LAN automation\u003c\/strong\u003e — Standard Command for Programmable Instruments over LAN for scripted test sequences.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003eUltra Phosphor 2.0\u003c\/h3\u003e\n\u003cp\u003eUltra Phosphor 2.0 is UNI-T's intensity-graded display technology. Waveforms paint with 256-level brightness, where signals that recur often appear bright and rare anomalies show as faint streaks against the baseline trace — the kind of detail a flat-color display paints over.\u003c\/p\u003e\n\u003cp\u003eStandard sampling reaches 150,000 wfms\/s; engaging Fast Acquire mode pushes the rate to 500,000 wfms\/s. Combined with hardware-accelerated continuous waveform recording at up to 120,000 frames, the scope catches glitches, runt pulses, and other transient events that 8-bit value-tier oscilloscopes typically don't surface.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003e\n\u003cbr\u003eIndependent DVM Module\u003c\/h3\u003e\n\u003cp\u003eThe UPO1104 includes a built-in 4-bit digital voltmeter that operates in parallel with the scope channels, displaying AC\/DC True RMS values continuously while the oscilloscope captures waveforms. The DVM has its own display readout and a configurable warning when measurements exceed the specified range — a separate instrument's worth of capability without a separate instrument's bench space, useful for steady-state DC monitoring alongside dynamic AC measurement and for double-checking power-supply rails without breaking the trigger setup.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003e\n\u003cbr\u003e1 Mpts Enhanced FFT\u003c\/h3\u003e\n\u003cp\u003eThe 1 Mpts FFT converts time-domain waveforms to the frequency domain at resolution that matches mid-tier oscilloscopes. Frequency setting, demodulation mode, waterfall display, and automatic peak marking are all standard, supporting EMI troubleshooting, switching-supply harmonic characterization, audio-band analysis, and clock-spur identification. Five window functions (Rectangle, Hanning, Blackman, Hamming, FlatTop) cover the common analysis trade-offs between frequency resolution and amplitude accuracy.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003eStandard Bus Decoding — RS-232\/UART, I²C, SPI\u003c\/h3\u003e\n\u003cp\u003eRS-232\/UART, I²C, and SPI trigger and decode are standard — no protocol licenses, no add-on packages. Decoded bus traffic overlays the waveform with field-level annotation, and the event list view shows decoded packets alongside the time stamps. Hardware decoding running across the full 56 Mpts memory turns what would be a tens-of-seconds software decode into a sub-second operation, making the UPO1000 a usable embedded-debug instrument rather than a strictly time-domain scope.\u003c\/p\u003e\n\u003cp\u003eNo optional protocol licenses are available on the UPO1104: CAN, CAN-FD, LIN, and FlexRay are not supported on this platform. Buyers who need automotive bus decoding should look at the UPO1000HD or MSO\/UPO2000 series, which support those protocols as paid options.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003e\n\u003cbr\u003e7-digit Hardware Frequency Counter\u003c\/h3\u003e\n\u003cp\u003eA 7-digit hardware-accelerated counter runs alongside the scope's standard automated measurements. The counter reads independently from the channel measurement engine, which gives stable, high-resolution frequency readings on stable signals without the jitter that software counters can exhibit on the lower-density end of the rate range. Useful for verifying oscillator frequencies, clock-recovery loops, and PWM duty cycles where a stable frequency number matters more than time-domain detail.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003e\n\u003cbr\u003eMultiple Trigger Types\u003c\/h3\u003e\n\u003cp\u003eBeyond standard edge triggering, the scope offers pulse width, video, slope, runt, over-amplitude, delay, timeout, duration, setup\/hold, Nth edge, and pattern triggers. Runt and over-amplitude triggers isolate signal-integrity violations that an edge-only trigger would never catch; setup\/hold and Nth edge triggers isolate specific cycles in long protocol captures. The full set is standard, with no trigger-package upgrades to license.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003e\n\u003cbr\u003e36 Automated Measurements with Cursor-Area Scoping\u003c\/h3\u003e\n\u003cp\u003eThirty-six automated measurement parameters cover time, voltage, frequency, and statistical categories: rise\/fall time, pulse width, duty cycle, frequency, period, amplitude, RMS, peak-peak, mean, standard deviation, and others. Each measurement supports cursor-area scoping — the measurement runs only within the cursor window rather than across the full record — useful for measuring a specific burst within a long capture without rezooming. Statistics (min, max, mean, std-dev) accumulate over time for characterization of measurement drift.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003e\n\u003cbr\u003eWeb Remote Control and SCPI Automation\u003c\/h3\u003e\n\u003cp\u003eConnect the UPO1104 to the LAN and access the full instrument from any web browser — PC, Mac, or mobile — with no driver installation, no host application, no setup. Capture screenshots, change settings, transfer waveform data, and run SCPI commands from any device on the network. Useful for shared lab instruments, rack-mounted teaching benches with cable runs across the room, and Python or LabVIEW automation scripts that drive the scope through standard SCPI over LAN.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003e\n\u003cbr\u003eConnectivity (USB, LAN, AUX)\u003c\/h3\u003e\n\u003cp\u003eStandard interfaces include USB-Host (front and rear) for thumb-drive screenshot capture and firmware updates, USB-Device (rear) for SCPI over USB to a PC, Gigabit LAN for SCPI and web remote, and AUX output for triggered signal handoff. RS-232 is not present on this platform; SCPI runs over USB and LAN. The LAN connection supports both DHCP and static IP configuration for fixed-IP rack deployments.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003e\n\u003cbr\u003eApplications\u003c\/h2\u003e\n\u003ch3\u003eTeaching Lab and Trade-School Curriculum (Education)\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMulti-station deployment at value-tier prices: a real 4 channels scope on every bench, with the same Ultra Phosphor 2.0 UI that students will see in industry on the UPO1000HD and MSO1000HD families.\u003c\/li\u003e\n\u003cli\u003e56 Mpts memory and 1 Mpts FFT cover the full spectrum-and-time-domain undergraduate curriculum without the memory-vs-sample-rate trade-offs that entry scopes normally impose.\u003c\/li\u003e\n\u003cli\u003e36 automated measurements with statistics let students focus on circuit behavior rather than measurement methodology, while the cursor-area mode supports manual measurement teaching.\u003c\/li\u003e\n\u003cli\u003eWeb-based remote control mirrors the screen for classroom demonstration without USB capture cables or projector adapters; SCPI over LAN supports Python and LabVIEW lab exercises.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEmbedded Systems Development (R\u0026amp;D)\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThree serial bus decoders standard (RS-232\/UART, I²C, SPI) cover most low-speed embedded debug workflows without protocol-license fees.\u003c\/li\u003e\n\u003cli\u003e56 Mpts memory captures full firmware-boot and protocol sequences in a single trigger, with full-memory hardware decoding for sub-second decode of long captures.\u003c\/li\u003e\n\u003cli\u003eIndependent DVM module reads supply rails alongside scope traces — useful for verifying brownout, monitoring switching ripple, or validating reference-voltage stability during prototype bring-up.\u003c\/li\u003e\n\u003cli\u003eSCPI over LAN runs Python regression scripts on the same instrument that the bench engineer uses interactively — automation without a separate automation-class scope.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectronics Service, Repair, and Maintenance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBench-portable form factor: AC-line bench scope sized for the typical service workshop without the depth or weight of a flagship instrument.\u003c\/li\u003e\n\u003cli\u003eUltra Phosphor 2.0 with 256-level intensity grading reveals signal-integrity violations (runt pulses, glitches) that flat-color displays paint over — the difference between fixing the root cause and replacing the symptom.\u003c\/li\u003e\n\u003cli\u003eHardware frequency counter gives stable rate readings for verifying oscillator and clock-recovery behavior during board-level repair.\u003c\/li\u003e\n\u003cli\u003eAC\/DC True RMS DVM module replaces the bench multimeter for steady-state checks while keeping the scope trigger configuration intact.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSwitching-Mode Power Supply Validation\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBandwidth selection from 100 MHz matches the switching frequency range of most commercial switching-mode designs at 100 kHz to several MHz, with 56 Mpts memory for capturing long startup transients without losing sample rate.\u003c\/li\u003e\n\u003cli\u003e1 Mpts FFT characterizes ripple harmonics and switching-noise spectral content for EMI pre-compliance investigation alongside time-domain switching analysis.\u003c\/li\u003e\n\u003cli\u003eMultiple trigger types (runt, over-amplitude, pulse-width) isolate switching faults, current spikes during startup, and protection-circuit activations.\u003c\/li\u003e\n\u003cli\u003eIndependent DVM module monitors output-rail DC value while scope captures dynamic AC load-step behavior — both halves of the supply characterization on one instrument.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProduction Test and Quality Control\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSCPI over LAN supports rack-mounted production-line deployment with Python or LabVIEW test scripts; the web remote interface gives line operators a familiar browser-based view without driver installation on each test station.\u003c\/li\u003e\n\u003cli\u003e36 automated measurements with statistics support go\/no-go testing of board-level signal-integrity specs; the cursor-area mode isolates specific cycles for measurement without re-zooming the full capture.\u003c\/li\u003e\n\u003cli\u003eContinuous waveform recording into the memory depth supports historical archiving of production-line captures for later analysis when a batch shows yield-tail issues.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEMI Pre-Compliance Investigation\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 Mpts FFT with five window functions, demodulation mode, and waterfall display supports time-correlated EMI investigation against the time-domain switching waveform — useful for tracking down which switching event produces which emission peak.\u003c\/li\u003e\n\u003cli\u003eMarker measurement on the FFT supports quick peak frequency and amplitude readout during emission-hunt work on a prototype board.\u003c\/li\u003e\n\u003cli\u003eCombined with a near-field probe set and a Faraday-cage cardboard tent, the FFT view supports pre-compliance investigation that catches the obvious failures before the expensive compliance-lab booking.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBandwidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChannels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReal-Time Sample Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 GSa\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSample Rate per Channel Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 GSa\/s on a single channel; 1 GSa\/s on two; 500 MSa\/s on all four\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCalculated Rise Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ 3.5 ns\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMemory Depth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e56 Mpts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVertical Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 bits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVertical Scale (1 MΩ)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 µV\/div to 20 V\/div\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Input Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400 V (DC + AC Vpk)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWaveform Capture Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500,000 wfms\/s (Fast Acquire mode); 150,000 wfms\/s normal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContinuous Frame Recording\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120,000 frames\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFFT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 Mpts enhanced FFT (5 window functions)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDVM\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIndependent module — 4-bit, AC\/DC True RMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency Counter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7-digit hardware\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAutomated Measurements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e36 parameters with statistics and cursor-area scoping\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrigger Types\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEdge, Pulse Width, Video, Slope, Runt, Over-Amplitude, Delay, Timeout, Duration, Setup\/Hold, Nth Edge, Pattern\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSerial Bus Decoding (Standard)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRS-232\/UART, I²C, SPI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOptional Protocol Decoders\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNone available on this platform\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7-inch WVGA TFT LCD, 256-level intensity grading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSB-Host (front + rear), USB-Device (rear), LAN (1 GbE), AUX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRemote Control\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWeb browser (no driver), SCPI over LAN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCE | cETLus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0°C to 40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLine Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100–240 VAC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e75 VA maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.45 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e306 × 138 × 107 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eDownloads\u003c\/h4\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cbr\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cstrong\u003e\u003ca rel=\"noopener\" title=\"UPO1000 Series Datasheet\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/UPO1000_Datasheet.pdf\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/pdf-icon-63x63_480x480.png\" style=\"float: left;\" alt=\"PDF\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/850009-i.pdf\" target=\"_blank\"\u003e\u003cbr\u003e\u003c\/a\u003e\u003ca rel=\"noopener\" title=\"UNI-T UPO1000 Series Datasheet\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/UPO1000_Datasheet.pdf\" target=\"_blank\"\u003eUNI-T UPO1000 Series Datasheet\u003c\/a\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cbr\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/UPO1000_-_User_Manual_-_V1.0.pdf\" target=\"_blank\" title=\"UNI-T UPO1000 Series Users Manual\" rel=\"noopener\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/pdf-icon-63x63_480x480.png\" style=\"float: left;\" alt=\"PDF\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/850009-i.pdf\" target=\"_blank\"\u003e\u003cbr\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/UPO1000_-_User_Manual_-_V1.0.pdf\" target=\"_blank\" title=\"UNI-T UPO1000 Series Users Manual\" rel=\"noopener\"\u003eUNI-T UPO1000 Series Users Manual\u003c\/a\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4\u003eOptions \u0026amp; Accessories\u003c\/h4\u003e\n\u003ch3\u003eIncluded\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUPO1104 digital storage oscilloscope\u003c\/li\u003e\n\u003cli\u003ePower cord (national standard)\u003c\/li\u003e\n\u003cli\u003eUSB 2.0 data cable\u003c\/li\u003e\n\u003cli\u003e4 × passive probes — UT-P04 (100 MHz, one per channel)\u003c\/li\u003e\n\u003cli\u003eQuick start guide\u003c\/li\u003e\n\u003cli\u003eFactory calibration certificate\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eRecommended Accessories\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigher-bandwidth passive probes\u003c\/strong\u003e — UT-P07A (500 MHz) for buyers anticipating a step-up scope in the future.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-voltage passive probes\u003c\/strong\u003e — UT-P20 (100:1, 250 MHz), UT-V23 (100:1), UT-P21 (1000:1, DC 10 kV \/ AC 7 kVrms) for line-voltage and HV switching work.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDifferential probes\u003c\/strong\u003e — UT-P30, UT-P31, UT-P32, UT-P33, UT-P35, UT-P36 for floating measurements where ground reference can't be tied to scope chassis.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent probes\u003c\/strong\u003e — UT-P40, UT-P41, UT-P42, UT-P43, UT-P44; UT-P4150 for high-current AC\/DC measurement on switching and motor-drive applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation transformer\u003c\/strong\u003e — UT-ISOT for line-powered DUTs that require galvanic isolation between scope ground and DUT ground.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFamily Members\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUPO1054 — 50 MHz, 4 channels, 2 GSa\/s\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUPO1104\u003c\/strong\u003e — 100 MHz, 4 channels, 2 GSa\/s \u003cem\u003e(this product)\u003c\/em\u003e\n\u003c\/li\u003e\n\u003cli\u003eUPO1204 — 200 MHz, 4 channels, 2 GSa\/s\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eStep Up — UPO1000HD (4-channel, 12-Bit Vertical)\u003c\/h3\u003e\n\u003cp\u003eIf your application needs higher vertical resolution or deeper memory than the UPO1104 provides, the UPO1000HD family offers 12-bit vertical resolution and the same Ultra Phosphor 2.0 display engine in the same cabinet footprint.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUPO1084HD — 80 MHz, 4 channels, 12-bit vertical resolution\u003c\/li\u003e\n\u003cli\u003eUPO1154HD — 150 MHz, 4 channels, 12-bit vertical resolution\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch4\u003eFAQ's\u003c\/h4\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003ch3 class=\"product-faq-question\"\u003eWhich serial bus protocols are decoded as standard, and which require a license?\u003c\/h3\u003e\n\u003cp\u003eThe UPO1104 decodes \u003cstrong\u003eRS-232\/UART, I²C, and SPI\u003c\/strong\u003e as standard — trigger and decode functions for all three are included with the scope, with no license fees and no protocol-option purchase required. \u003cstrong\u003eNo optional protocol decoders are available on this platform.\u003c\/strong\u003e CAN, CAN-FD, LIN, and FlexRay are not supported on the UPO1000 platform. If your application requires automotive bus decoding, the UPO1000HD or MSO\/UPO2000 series support those protocols as paid options.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003ch3 class=\"product-faq-question\"\u003eWhat is Fast Acquire mode, and when should I use it?\u003c\/h3\u003e\n\u003cp\u003eFast Acquire is a UPO1000-series acquisition mode that boosts waveform capture rate from 150,000 wfms\/s (standard) to \u003cstrong\u003e500,000 wfms\/s\u003c\/strong\u003e. The trade-off is that some screen-update detail is sacrificed for raw capture throughput. Use Fast Acquire when hunting intermittent signal-integrity events (glitches, runt pulses, rare protocol violations) that depend on capturing many waveforms quickly. Use standard mode for everyday time-domain measurement work where the display refresh rate matters more than raw capture density.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003ch3 class=\"product-faq-question\"\u003eDoes the DVM module share input channels with the scope, or is it truly independent?\u003c\/h3\u003e\n\u003cp\u003eThe DVM is \u003cstrong\u003etruly independent\u003c\/strong\u003e: it has its own 4-bit measurement input and operates in parallel with the four (or two) scope channels. You can run a continuous AC\/DC True RMS reading on a supply rail while the scope captures dynamic switching behavior on another channel, without any time-sharing between the two functions. The DVM readout appears on a dedicated portion of the screen and persists across scope-channel configuration changes.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003ch3 class=\"product-faq-question\"\u003eWhat does the web remote control look like in practice, and how does SCPI automation work?\u003c\/h3\u003e\n\u003cp\u003eConnect the UPO1104 to your LAN, point any browser at the scope's IP, and you get a full-screen replica of the front panel that you can drive from your desk or a mobile device — no driver installation, no host application. Useful for shared lab instruments and projection during teaching demos. For automation, the scope responds to \u003cstrong\u003eSCPI commands over LAN\u003c\/strong\u003e (Standard Commands for Programmable Instruments), which means Python (pyvisa), MATLAB Instrument Control Toolbox, LabVIEW, and any other VISA-aware tool can drive the scope through scripts. SCPI also runs over USB-Device for PC-tethered automation when LAN isn't available.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4\u003eVideos\u003c\/h4\u003e\n\u003cp\u003e\u003ciframe title=\"YouTube video player\" src=\"https:\/\/www.youtube.com\/embed\/PVhwBHhRIrs?si=LZyAGKknhQkuuSTp\" height=\"315\" width=\"560\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Uni-Trend US","offers":[{"title":"Default Title","offer_id":53265476321504,"sku":"181100200076X","price":407.2,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/UPO1104_1_sq.jpg?v=1782858083"},{"product_id":"ut-p21-50-mhz-1000-1-high-voltage-oscilloscope-probe","title":"UT-P21 50 MHz 1000:1 High Voltage Oscilloscope Probe","description":"\u003ch1\u003e40MHz (-3dB) high-voltage passive probe (1000:1 attenuation) for measuring power supply rails, inverters and high-voltage circuits up to several kV.\u003c\/h1\u003e\n\u003cp\u003e\u003cstrong\u003eCompatible with UNI-T oscilloscopes and most oscilloscopes with BNC inputs.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e40MHz (-3dB) Bandwidth\u003c\/strong\u003e — Captures signal content up to 40MHz for accurate waveform measurement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e1000:1 Attenuation\u003c\/strong\u003e — Attenuation ratio suited to the probe measurement range.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDC 15kVrms\/AC 10kV Maximum Input Voltage\u003c\/strong\u003e — Rated input voltage for safe operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard BNC Connection\u003c\/strong\u003e — Compatible with UNI-T oscilloscopes and most oscilloscopes with BNC inputs.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eΦ80mm×340mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20 °C - 70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBandwidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe Attenuation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1000:1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe Max Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC 10 kV \/ AC 7kVrms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRise Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ 8.8ns\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBNC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Capacitance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.0 pF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompensation Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 pF-50 pF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 °C - 50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n","brand":"Uni-Trend US","offers":[{"title":"Default Title","offer_id":53265476419808,"sku":"190500300013","price":430.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/UT-P21_1_sq.jpg?v=1782858083"},{"product_id":"upo2204hd-200-mhz-4ch-12-bit-high-resolution-oscilloscope","title":"UPO2204HD 200 MHz 4Ch 12-Bit High-Resolution Oscilloscope","description":"\u003ch1\u003eThe UNI-T UPO2204HD is a 200 MHz 4-channel 12-bit high-resolution oscilloscope built around the R12™ native 12-bit ADC.\u003c\/h1\u003e\n\u003cp\u003eIt samples at 2.5 GSa\/s with 100 Mpts memory depth standard, and Ultra Phosphor 3.0 acquisition pushes the waveform capture rate to 1,000,000 wfms\/s in sequence mode, sixteen times the vertical detail of an 8-bit scope, held at full bandwidth without ERES averaging or sample-rate trade-offs. The 10.1-inch capacitive multi-touch display, on-instrument 4 Mpts FFT, 9 standard protocol decoders, and built-in WebServer round out a six-instrument bench in a single chassis.\u003c\/p\u003e\n\u003cp\u003eThe four-channel UPO2204HD is the flagship of the UPO2000HD family — 200 MHz bandwidth, four simultaneous analog channels, 70 µVrms background noise, and 12-bit resolution at the full bandwidth without ERES or sample-rate compromise. For multi-rail switching-converter validation where high-side gate drive, low-side gate drive, switching node, and output ripple all need to be observed in one acquisition, this is the configuration.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eR12™ 12-bit native ADC\u003c\/strong\u003e — 4,096 vertical levels held at the full 200 MHz bandwidth. No ERES averaging, no sample-rate trade-off.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e200 MHz bandwidth, 4 analog channels\u003c\/strong\u003e — 2.5 GSa\/s real-time sample rate, 100 Mpts standard memory depth. Full-bandwidth 12-bit resolution with 70 µVrms noise floor for power-electronics work.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUltra Phosphor 3.0 — 1,000,000 wfms\/s\u003c\/strong\u003e — Sequence-mode capture rate with 256-level grayscale persistence; surfaces intermittent and rare events.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e6 instruments in one\u003c\/strong\u003e — Oscilloscope, spectrum analyzer, digital voltmeter, hardware frequency meter, protocol analyzer, and optional power analysis on a single chassis.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e9 protocol decoders standard\u003c\/strong\u003e — RS-232\/UART, I²C, SPI, CAN, CAN-FD, LIN, FlexRay, SENT, and Audio. No license fees, no time-boxed unlocks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e10.1-inch capacitive touchscreen\u003c\/strong\u003e — 1280×800 multi-touch with pinch, drag, zoom, and rectangle-draw gestures. Mouse and keyboard supported in parallel.\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003cstrong\u003e4 Mpts enhanced FFT, 56 automated measurements, hardware mask test, zone trigger, ERES up to 4-bit standard.\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eDetailed Features\u003c\/h2\u003e\n\u003ch3\u003eR12™ — Native 12-Bit ADC at Full Bandwidth\u003c\/h3\u003e\n\u003cp\u003eR12™ is UNI-T's native 12-bit ADC architecture, holding 4,096 quantization levels at the full 200 MHz bandwidth and 2.5 GSa\/s sample rate without ERES averaging or sample-rate trade-off. Background noise is 70 µVrms at full bandwidth — low enough that the 12-bit resolution actually shows up on the screen instead of being buried in the noise floor. For power-electronics validation where µV-scale ripple rides on a 400V bias rail, that headroom is the measurement.\u003c\/p\u003e\n\u003ch3\u003eUltra Phosphor 3.0 — 1,000,000 wfms\/s Acquisition\u003c\/h3\u003e\n\u003cp\u003eUltra Phosphor 3.0 is UNI-T's third-generation acquisition engine. Eight-channel parallel graphics processing at up to 20 Gbps drives a continuous capture rate of 250,000 wfms\/s, with sequence mode pushing the rate to 1,000,000 wfms\/s for trigger-conditioned events. 256-level grayscale persistence makes intermittent runts, glitches, and jitter visible as density gradients on screen rather than as occasional flashes that the eye misses. The same engine drives the digital trigger system — high sensitivity, low jitter, and zone trigger for isolating non-repeating signals.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e6 Instruments in One\u003c\/h3\u003e\n\u003cp\u003eThe UPO2204HD integrates six instrument functions into a single chassis: high-resolution oscilloscope, FFT spectrum analyzer with 4 Mpts and waterfall display, 4-digit digital voltmeter with DC\/AC RMS modes, 7-digit hardware frequency meter, 9-protocol decoder and trigger engine, and the optional 12-parameter power analysis suite. With four analog channels feeding all of them, multi-rail converter validation and multi-bus protocol correlation happen on the same instrument without the cabling and context-switching of separate boxes.\u003c\/p\u003e\n\u003ch3\u003eDeep Memory — 100 Mpts Standard\u003c\/h3\u003e\n\u003cp\u003e100 Mpts of memory comes standard, not as an upgrade. At 2.5 GSa\/s that captures 40 ms of full-rate signal in a single acquisition — long enough to record a complete soft-start sequence, a fault-recovery transient, or a multi-frame burst without re-arming. Combined with hardware-accelerated mask testing, the 4-bit ERES enhanced-resolution mode, and uninterrupted recording of up to 125,000 frames, the deep memory turns long-running events from a sampling problem into a navigation problem.\u003c\/p\u003e\n\u003ch3\u003eAll Protocols Included Standard\u003c\/h3\u003e\n\u003cp\u003eNine serial-bus protocol decoders are included with every UPO2204HD: RS-232\/UART, I²C, SPI, CAN, CAN-FD, LIN, FlexRay, SENT, and Audio. Each protocol supports both triggering and decoding, with event-list and search functions for navigating long captures. Decoded data appears alongside the analog waveform on the same trace — correlate a misbehaving I²C transaction with the supply-rail glitch that caused it, or align CAN-FD frames with the gate-drive event that triggered the fault recovery. No license fees, no time-boxed unlocks — the protocols are standard.\u003c\/p\u003e\n\u003ch3\u003ePower Analysis — Optional 12-Parameter Suite\u003c\/h3\u003e\n\u003cp\u003eThe optional power-analysis package adds 12 measurement and analysis functions to the UPO2204HD: power quality, harmonic analysis, current harmonics, R\u003csub\u003eDS(on)\u003c\/sub\u003e, switching loss, slew rate, safe operating area, modulation analysis, output ripple, startup\/shutdown time, transient response, and power efficiency. Connect a voltage probe and a current probe, select the analysis type, and the UPO2204HD renders the results without external post-processing — the metrics that drive switching-converter design decisions, on the bench, alongside the time-domain trace.\u003c\/p\u003e\n\u003ch3\u003eBuilt-In Spectrum Analyzer — FFT to 4 Mpts\u003c\/h3\u003e\n\u003cp\u003eStandard enhanced FFT analysis runs at up to 4 Mpts across all channels with a frequency range from 0 to 1.25 GHz, four traces, four detection modes, and a waterfall display for tracking spectrum changes over time. Auto, manual, and threshold marker modes locate harmonics, spurs, and EMI sources without switching to a separate spectrum analyzer. For pre-compliance spot checks during board bring-up and switching-noise investigation during converter design, the on-instrument FFT closes a common bench-workflow gap.\u003c\/p\u003e\n\u003ch3\u003e56 Automated Measurements with Statistics\u003c\/h3\u003e\n\u003cp\u003e56 parameter measurements run continuously on every channel, with up to 27 measurements visible on screen and 39 single-channel parameters in the snapshot view. Statistics, histograms, and trend charts visualize each parameter's distribution over time. The new amplitude calculation strategy with top\/bottom and burst-parameter handling makes the numbers correct on signals where naive measurement engines pick the wrong reference levels. No post-processing, no spreadsheet export — the answer is on the screen.\u003c\/p\u003e\n\u003ch3\u003e10.1-Inch Touch UI and Full Connectivity\u003c\/h3\u003e\n\u003cp\u003eThe 10.1-inch 1280×800 capacitive multi-touch display supports pinch, drag, zoom, rectangle-draw, and edit gestures alongside the traditional knobs and one-touch front-panel keys. Mouse and keyboard are supported in parallel. The peripheral set includes USB Host, USB Device, LAN, EXT Trig, AUX Out (Trig Out \/ Pass-Fail), and HDMI for projector or external-monitor display. SCPI is standard, the built-in WebServer enables browser-based remote control from a PC or mobile device, and firmware updates are free over the product's lifetime. For automated power-converter qualification benches, the SCPI command set drives waveform capture, mask-test pass\/fail, and long-record export from a Python or LabVIEW test harness.\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003ch3\u003eR\u0026amp;D Engineer (Embedded \/ Hardware \/ Analog Design)\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower-Electronics Validation\u003c\/strong\u003e — GaN\/SiC half-bridge characterization, switching-node ringing analysis, and µV-scale ripple-on-bias measurement at 200 MHz bandwidth with 70 µVrms noise floor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSerial-Bus Debug\u003c\/strong\u003e — Time-correlated analog and protocol-decode views in the same trace; 9 protocols included standard.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal-Integrity Spot Checks\u003c\/strong\u003e — On-instrument 4 Mpts FFT identifies harmonics, clock spurs, and EMI sources without switching to a separate spectrum analyzer.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLong-Capture Investigation\u003c\/strong\u003e — 100 Mpts memory plus 125,000-frame waveform recording captures complete soft-start, fault-recovery, and burst-mode events without re-arming.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePower Electronics Engineer\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMulti-Rail Switching-Converter Validation\u003c\/strong\u003e — Four-channel 200 MHz configuration observes high-side gate drive, low-side gate drive, switching node, and output ripple in a single acquisition with 12-bit fidelity at 70 µVrms.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptional 12-Parameter Power Analysis\u003c\/strong\u003e — Power quality, switching loss, R\u003csub\u003eDS(on)\u003c\/sub\u003e, SOA, transient response, and ripple analysis on the same instrument as the time-domain trace.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHardware-Accelerated Mask Testing\u003c\/strong\u003e — Pass\/fail validation against switching-waveform templates completes in seconds; AUX Out drives an alarm or DUT shutdown on out-of-mask events.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLong-Transient Capture\u003c\/strong\u003e — 100 Mpts captures complete soft-start and fault-recovery sequences in one trigger; 125,000-frame waveform recorder for repetitive burst-mode operation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eOptions \u0026amp; Accessories\u003c\/h4\u003e\n\u003ch3\u003eIncluded with the Instrument\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUPO2204HD oscilloscope\u003c\/li\u003e\n\u003cli\u003e4 × passive probes (1:1 \/ 10:1 switchable, bandwidth matched to instrument)\u003c\/li\u003e\n\u003cli\u003eUSB cable (USB-A to USB-B)\u003c\/li\u003e\n\u003cli\u003ePower cord (region-appropriate)\u003c\/li\u003e\n\u003cli\u003eQuick-start guide\u003c\/li\u003e\n\u003cli\u003eFactory calibration certificate\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eRecommended Accessories\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUPO2000HD-PWR — optional 12-parameter power-analysis package activation\u003c\/li\u003e\n\u003cli\u003eUT-P07A — 500 MHz passive probe for higher-bandwidth applications\u003c\/li\u003e\n\u003cli\u003eUT-P20, UT-P21, UT-V23 — high-voltage passive probes\u003c\/li\u003e\n\u003cli\u003eUT-P30, UT-P31, UT-P32, UT-P33 — differential probes for floating measurements\u003c\/li\u003e\n\u003cli\u003eUT-P40, UT-P41, UT-P42, UT-P43, UT-P44 — current probes for power-stage and switching-loss measurement\u003c\/li\u003e\n\u003cli\u003eUT-ISOT — isolation transformer for safe line-powered measurements\u003c\/li\u003e\n\u003cli\u003eUT-M13X — oscilloscope demo board for protocol decoding practice and curriculum modules\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSoftware Options\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUPO2000HD-PWR — Power Analysis Option for UPO2000HD\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eNeed different bandwidth or channel-count? Compare with family-mates: UPO2202HD, UPO2104HD, UPO2074HD.\u003c\/p\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBandwidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChannels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 Analog\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSample Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.5 GSa\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVertical Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 bits (R12™ native)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMemory Depth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 Mpts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCapture Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1,000,000 wfms\/s (sequence mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10.1-inch capacitive touchscreen, 1280×800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTouch Screen\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrigger Modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEdge, pulse width, video, ramp, runt, over-amplitude, delay, timeout, duration, setup\/hold, Nth edge, code pattern\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZone Trigger\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes — 2 zones, must-intersect \/ must-not-intersect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtocol Decoding (Standard)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRS-232\/UART, I²C, SPI, CAN, CAN-FD, LIN, FlexRay, SENT, Audio\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBuilt-In FFT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes — up to 4 Mpts, 0 to 1.25 GHz, 4 traces, waterfall\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBuilt-In Power Analysis\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOptional — 12 parameters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBuilt-In Spectrum Analyzer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes (standard FFT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDigital Voltmeter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4-digit; DC, AC RMS, AC+DC RMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency Meter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7-digit hardware\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAutomated Measurements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e56 with statistics, histogram, and trend\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eERES (Enhanced Resolution)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 4-bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMask Testing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHardware-accelerated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWaveform Recording\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 125,000 frames; USB export\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSB Host \/ USB Device \/ LAN \/ EXT Trig \/ AUX Out \/ HDMI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRemote Control\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSCPI standard; built-in WebServer (browser access)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRoHS Compliant\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCE, cETLus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eDownloads\u003c\/h4\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cbr\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/UPO2000HD_-_Data_Sheet_-_V1.1.pdf\" title=\"UPO2000 Series Datasheet\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/pdf-icon-63x63_480x480.png\" style=\"float: left;\" alt=\"PDF\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/850009-i.pdf\" target=\"_blank\"\u003e\u003cbr\u003e\u003c\/a\u003e\u003ca rel=\"noopener\" title=\"UNI-T UPO1000 Series Datasheet\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/UPO2000HD_-_Data_Sheet_-_V1.1.pdf?v=1783018853\" target=\"_blank\"\u003eUNI-T UPO2000HD Series Datasheet\u003c\/a\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cbr\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/UPO2000HD_-_User_Manual_-_V1.1.pdf\" title=\"UNI-T UPO2000HD Series Users Manual\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/pdf-icon-63x63_480x480.png\" style=\"float: left;\" alt=\"PDF\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/850009-i.pdf\" target=\"_blank\"\u003e\u003cbr\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/UPO2000HD_-_User_Manual_-_V1.1.pdf\" title=\"UN I-T UPO1000 Series Users Manual\" rel=\"noopener\" target=\"_blank\"\u003eUNI-T UPO2000HD Series Users Manual\u003c\/a\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eFAQ's\u003c\/h4\u003e\n\u003ch3\u003eWhat protocols are included with the UPO2204HD?\u003c\/h3\u003e\n\u003cp\u003eRS-232\/UART, I²C, SPI, CAN, CAN-FD, LIN, FlexRay, SENT, and Audio decoding are included standard at no additional cost. All nine supported protocols are available out of the box — no optional licenses required, no time-boxed unlocks.\u003c\/p\u003e\n\u003ch3\u003eWhat is the advantage of native 12-bit resolution?\u003c\/h3\u003e\n\u003cp\u003eA 12-bit ADC provides 4,096 vertical levels compared to 256 for an 8-bit scope — sixteen times greater detail. This reveals small signals riding on large ones, reduces quantization noise, and improves measurement accuracy on low-amplitude signals like power-supply ripple, sensor outputs, and precision analog circuits. R12™ holds the 12-bit resolution at the full bandwidth and sample rate, with no ERES averaging or sample-rate trade-off.\u003c\/p\u003e\n\u003ch3\u003eCan I add power-supply analysis?\u003c\/h3\u003e\n\u003cp\u003eYes. The optional power-analysis package adds 12 measurements: power quality, harmonic analysis, current harmonics, R\u003csub\u003eDS(on)\u003c\/sub\u003e, switching loss, slew rate, safe operating area, modulation analysis, output ripple, startup\/shutdown time, transient response, and power efficiency. The UPO2000HD-PWR activation unlocks the package on any UPO2000HD-series oscilloscope.\u003c\/p\u003e\n\u003ch3\u003eHow does the touchscreen handle daily lab use?\u003c\/h3\u003e\n\u003cp\u003eThe 10.1-inch capacitive multi-touch display supports pinch, drag, zoom, rectangle-draw, and edit gestures alongside the traditional knobs and one-touch front-panel keys. Mouse and keyboard are supported in parallel. For lab settings where students or engineers cycle through the instrument frequently, the gesture set is familiar from consumer devices; for production-style workflows where physical controls are preferred, the front panel still does what front panels do.\u003c\/p\u003e\n\u003ch3\u003eHow does the UPO2204HD compare to 8-bit oscilloscopes at similar bandwidth?\u003c\/h3\u003e\n\u003cp\u003eThe 12-bit ADC delivers 16× the vertical resolution of an 8-bit scope at the same bandwidth, with no ERES averaging or sample-rate trade-off. Low-amplitude signals — switching ripple, sensor outputs, precision analog circuits — that 8-bit scopes flatten into quantization noise show up clearly on the 12-bit display. For analog precision work and switching-converter validation, the resolution advantage is structural, not a marketing comparison.\u003c\/p\u003e\n\u003ch3\u003eIs the firmware field-upgradable?\u003c\/h3\u003e\n\u003cp\u003eYes. Firmware updates are free over the product's lifetime and install via USB drive or LAN transfer. Optional license unlocks (such as the power-analysis package) have no expiration.\u003c\/p\u003e\n\u003ch3\u003eCan the instrument be controlled from a PC or from a browser?\u003c\/h3\u003e\n\u003cp\u003eBoth. SCPI is supported standard via USB Device or LAN for automated test scripts and PC-side instrument-management software. The built-in WebServer enables direct browser-based control from a PC or mobile device on the same network — no PC-side software install required.\u003c\/p\u003e\n\u003cp\u003ePart of the UPO2000HD oscilloscope series. All models share the R12™ native 12-bit ADC, 2.5 GSa\/s sample rate, 100 Mpts memory, Ultra Phosphor 3.0 acquisition, and 9 standard protocol decoders. Bandwidth options span 70 \/ 100 \/ 200 MHz; channel options are 2-channel and 4-channel. See the series page to compare configurations.\u003c\/p\u003e\n\u003ch4\u003eVideos\u003c\/h4\u003e\n\u003cp\u003e\u003ciframe title=\"YouTube video player\" src=\"https:\/\/www.youtube.com\/embed\/Rr228a8I8Zg?si=KaX_wNY2nBhVOK4O\" height=\"315\" width=\"560\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e","brand":"Uni-Trend US","offers":[{"title":"Default Title","offer_id":53265476387040,"sku":"181100200139X","price":1092.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/UPO2204HD_1_sq.jpg?v=1782858082"},{"product_id":"mso1254hd-250-mhz-4ch-12-bit-mixed-signal-oscilloscope","title":"MSO1254HD 250 MHz 4Ch 12-Bit Mixed Signal Oscilloscope","description":"\u003ch1\u003eThe MSO1254HD is a lab-grade 250 MHz, four-channel mixed signal oscilloscope built on UNI-T's R12™ native 12-bit ADC architecture, engineered for switching power supply validation, wide-bandgap (GaN\/SiC) power-stage characterization, embedded-system development and mixed-signal debugging.\u003c\/h1\u003e\n\u003cp\u003eThe native 12-bit acquisition system maintains the full 250 MHz analog bandwidth at 2.5 GSa\/s without ERES averaging or sample-rate tradeoffs, delivering 4,096 vertical levels and 100 Mpts of acquisition memory per channel. Ultra Phosphor 3.0 waveform mapping captures up to 1,000,000 wfms\/s, while a 7-inch capacitive touchscreen and optional 16-channel logic analyzer provide an intuitive platform for analog and digital system validation. The MSO1254HD integrates nine instrument functions into a single bench platform, combining oscilloscope, logic analyzer (optional UT-M26), spectrum analyzer, protocol analyzer, digital voltmeter, frequency counter, power analyzer, and advanced measurement tools without additional hardware.\u003c\/p\u003e\n\u003cp\u003eFor switching converter design, GaN and SiC gate-drive characterization, multi-rail power analysis, embedded firmware debugging, and precision analog measurements where 8-bit oscilloscopes struggle with low-level signals, the MSO1254HD occupies the performance tier where higher bandwidth and native 12-bit resolution become equally important. The full 250 MHz bandwidth captures fast switching edges and ringing, while the 12-bit architecture resolves mV- and µV-scale ripple riding on high-voltage DC rails. Standard decoding for RS-232\/UART, I²C, SPI, RS-422\/485, CAN, CAN-FD, LIN, and Audio, together with optional 16-channel mixed-signal acquisition, allows simultaneous correlation of firmware activity, serial communications, and analog power-stage behavior from a single instrument.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e250 MHz Bandwidth, 4 Analog Channels\u003c\/strong\u003e — Four-channel acquisition with native 12-bit resolution, 2.5 GSa\/s maximum sample rate, and full 250 MHz bandwidth for switching-power validation, embedded-system development, and precision analog measurements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eR12™ Native 12-Bit ADC\u003c\/strong\u003e — 4,096 vertical quantization levels maintained at the full 250 MHz bandwidth and full sample rate with no ERES averaging or sample-rate reduction. Up to 16-bit effective resolution available with ERES mode.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e2.5 GSa\/s Sample Rate, 100 Mpts Memory\u003c\/strong\u003e — Full-speed real-time acquisition with 100 Mpts memory per channel captures long-duration events without sacrificing timing resolution.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eUltra Phosphor 3.0 Acquisition\u003c\/strong\u003e — Waveform capture rates up to 1,000,000 wfms\/s with 256-level intensity grading expose intermittent glitches, timing violations, and rare events conventional oscilloscopes can miss.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNine Instruments in One\u003c\/strong\u003e — Oscilloscope, logic analyzer (optional UT-M26), enhanced FFT spectrum analyzer, protocol analyzer, digital voltmeter, frequency counter, power analyzer, automated measurements, and mask testing integrated into one instrument.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e16 Optional Digital Channels\u003c\/strong\u003e — Add the UT-M26 logic probe pod for time-correlated mixed-signal analysis across analog and digital domains.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e10 Standard Protocol Decoders\u003c\/strong\u003e — RS-232\/UART, RS-422, RS-485, I²C, SPI, CAN, CAN-FD, LIN, and Audio decoding included standard with trigger, search, and event-list capabilities.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBuilt-In Power Analysis\u003c\/strong\u003e — Twelve standard power-analysis measurements including efficiency, ripple, switching loss, harmonic analysis, and safe operating area visualization.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnhanced FFT Spectrum Analyzer\u003c\/strong\u003e — Up to 1 Mpts FFT with peak detection, markers, waterfall display, and harmonic analysis for EMI investigation and frequency-domain troubleshooting.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e7-Inch Capacitive Touchscreen\u003c\/strong\u003e — 1024 × 600 multi-touch display with pinch-to-zoom, gesture navigation, and intuitive waveform control.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eComplete Connectivity\u003c\/strong\u003e — USB Host, USB Device, LAN, HDMI, and AUX output support remote control, automation, external displays, and production test integration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eDetailed Features\u003c\/h2\u003e\n\u003ch3\u003eNative 12-Bit R12™ Architecture\u003c\/h3\u003e\n\u003cp\u003eThe MSO1254HD is built around UNI-T's R12™ native 12-bit ADC architecture, delivering 4,096 vertical quantization levels across the full 250 MHz bandwidth and 2.5 GSa\/s sample rate without bandwidth reduction, digital averaging, or sample-rate compromise. Unlike conventional 8-bit oscilloscopes that lose low-level detail in quantization noise, the native 12-bit acquisition system clearly resolves switching ripple, gate-drive ringing, sensor outputs, and small analog signals while preserving fast-edge performance. Optional ERES processing extends effective vertical resolution even further when working with band-limited signals.\u003c\/p\u003e\n\u003ch3\u003eUltra Phosphor 3.0 Acquisition Engine\u003c\/h3\u003e\n\u003cp\u003eUltra Phosphor 3.0 combines high-speed acquisition with 256-level intensity grading to capture up to 1,000,000 waveforms per second. The persistence display makes intermittent glitches, runt pulses, timing jitter, and protocol anomalies visible as intensity variations rather than isolated events that disappear between screen updates. For engineers tracking elusive failures, the high waveform capture rate significantly improves the probability of capturing infrequent events during live debugging.\u003c\/p\u003e\n\u003ch3\u003eDeep Memory — 100 Mpts Per Channel\u003c\/h3\u003e\n\u003cp\u003eEvery analog channel includes 100 Mpts of acquisition memory, allowing long capture windows while maintaining the full 2.5 GSa\/s sample rate. Engineers can capture complete startup sequences, switching transients, protocol transactions, and fault-recovery events in a single acquisition before zooming into individual edges at full timing resolution. Deep memory eliminates the sample-rate compromises often required on lower-end oscilloscopes during long-duration captures.\u003c\/p\u003e\n\u003ch3\u003eMixed-Signal Debugging\u003c\/h3\u003e\n\u003cp\u003eWith the optional UT-M26 logic probe, the MSO1254HD expands into a 16-channel mixed-signal oscilloscope capable of displaying digital and analog signals on a common time base. Firmware activity, serial buses, GPIO timing, and analog responses can be analyzed simultaneously, simplifying root-cause analysis where hardware and software interact. Time-correlated triggering allows engineers to identify relationships that would otherwise require multiple instruments.\u003c\/p\u003e\n\u003ch3\u003eComplete Protocol Analysis Standard\u003c\/h3\u003e\n\u003cp\u003eUnlike many competing oscilloscopes that require paid software licenses, the MSO1254HD includes decoding and triggering for RS-232\/UART, RS-422, RS-485, I²C, SPI, CAN, CAN-FD, LIN, and Audio buses as standard features. Decoded packets are displayed directly above the physical waveform with searchable event lists and protocol-specific triggers, allowing communication errors to be correlated immediately with analog signal behavior.\u003c\/p\u003e\n\u003ch3\u003eIntegrated Power Analysis\u003c\/h3\u003e\n\u003cp\u003eThe built-in power-analysis package provides twelve measurement categories including efficiency, switching loss, harmonic analysis, ripple, safe operating area, transient response, startup\/shutdown timing, and power quality. Voltage and current waveforms are analyzed directly within the oscilloscope, eliminating the need for external software or separate power analyzers during converter development and validation.\u003c\/p\u003e\n\u003ch3\u003eEnhanced FFT Spectrum Analyzer\u003c\/h3\u003e\n\u003cp\u003eThe integrated spectrum analyzer performs FFT analysis with record lengths up to 1 Mpts, providing peak detection, multiple markers, waterfall display, and harmonic analysis for switching-frequency investigation, EMI troubleshooting, and clock analysis. Engineers can move seamlessly between time-domain and frequency-domain measurements without exporting waveform data to external software.\u003c\/p\u003e\n\u003ch3\u003eAutomated Measurements and Statistical Analysis\u003c\/h3\u003e\n\u003cp\u003eFifty-six automated measurements continuously evaluate voltage, timing, frequency, and power parameters while statistical analysis tracks minimum, maximum, average, standard deviation, and long-term trends. Histogram and trend displays simplify characterization, production validation, and long-duration stability testing without requiring offline analysis.\u003c\/p\u003e\n\u003ch3\u003eTouchscreen Interface and Connectivity\u003c\/h3\u003e\n\u003cp\u003eThe 7-inch capacitive multi-touch display supports intuitive gesture controls including pinch-to-zoom, drag, and waveform navigation while maintaining dedicated front-panel controls for traditional operation. USB Host, USB Device, LAN, HDMI, and AUX output provide flexible connectivity for automated test systems, classroom environments, remote operation, and external display support.\u003c\/p\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003ch3\u003eFor R\u0026amp;D Engineers\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eSwitching power-supply validation, GaN and SiC power-stage characterization, embedded-system development, and mixed-signal debugging using four analog channels with native 12-bit resolution and optional 16-channel logic analysis.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTime-correlated analog and digital analysis for firmware development, serial communication troubleshooting, and hardware\/software integration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStandard protocol decoding for embedded, industrial, and automotive buses without additional software licenses.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHigh-speed waveform capture up to 1,000,000 wfms\/s improves intermittent fault detection and timing analysis.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFor Power Electronics Engineers\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eFour-channel observation of switching node, gate drive, output voltage, and control signals during converter development and validation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNative 12-bit acquisition resolves low-level ripple and switching noise on high-voltage DC rails with significantly greater precision than conventional 8-bit oscilloscopes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBuilt-in power-analysis measurements quantify efficiency, switching loss, ripple, harmonic content, and transient response directly from captured waveforms.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDeep memory captures complete startup, shutdown, burst-mode, and fault-recovery sequences in a single acquisition while preserving full sample-rate resolution.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBandwidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChannels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 Analog + 16 Optional Digital\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSample Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.5 GSa\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVertical Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 bits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMemory Depth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 Mpts per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCapture Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1,000,000 wfms\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7-inch capacitive touchscreen, 1024×600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTouch Screen\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrigger Modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEdge, pulse width, video, runt, slope, zone, setup\/hold, and more\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtocol Decoding (Standard)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRS-232\/UART, I²C, SPI, RS-422, RS-485, CAN, CAN-FD, LIN, Audio\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBuilt-In FFT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes — up to 1 Mpts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBuilt-In Power Analysis\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 parameters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBuilt-In Spectrum Analyzer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAutomated Measurements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e56 with statistics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBuilt-In AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo (available on -S models)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBode Plot Analysis\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo (available on -S models)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLogic Analyzer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOptional 16-channel via UT-M26 pod\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSB Host \/ USB Device \/ LAN \/ AUX Out \/ HDMI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRoHS Compliant\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eDownloads\u003c\/h4\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cbr\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/MSO1000HD_-_Data_Sheet_-_V1.0.pdf\" title=\"MSO1000HD Series Datasheet\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/pdf-icon-63x63_480x480.png\" style=\"float: left;\" alt=\"PDF\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/850009-i.pdf\" target=\"_blank\"\u003e\u003cbr\u003e\u003c\/a\u003e\u003ca title=\"UNI-T MSO1000HD Series Datasheet\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/MSO1000HD_-_Data_Sheet_-_V1.0.pdf\"\u003eUNI-T MSO1000HD Series Datasheet\u003c\/a\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cbr\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/MSO1000HD_-_User_Manual_-_V1.0.pdf\" title=\"UNI-T MSO1000HD Series Users Manual\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/pdf-icon-63x63_480x480.png\" style=\"float: left;\" alt=\"PDF\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/850009-i.pdf\" target=\"_blank\"\u003e\u003cbr\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/MSO1000HD_-_User_Manual_-_V1.0.pdf\" title=\"UNI-T MSO1000HD Series Users Manual\" rel=\"noopener\" target=\"_blank\"\u003eUNI-T MSO1000HD Series Users Manual\u003c\/a\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eOptions \u0026amp; Accessories\u003c\/h4\u003e\n\u003ch3\u003eIncluded with the Instrument\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMSO1254HD oscilloscope\u003c\/li\u003e\n\u003cli\u003e4 × passive probes (1:1 \/ 10:1 switchable, bandwidth matched to instrument)\u003c\/li\u003e\n\u003cli\u003eUSB cable (USB-A to USB-B)\u003c\/li\u003e\n\u003cli\u003ePower cord (region-appropriate)\u003c\/li\u003e\n\u003cli\u003eQuick-start guide\u003c\/li\u003e\n\u003cli\u003eFactory calibration certificate\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eRecommended Accessories\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUT-M26 — 16-channel logic probe pod for mixed-signal debugging\u003c\/li\u003e\n\u003cli\u003eUT-P07A — 500 MHz passive probe for higher-bandwidth applications\u003c\/li\u003e\n\u003cli\u003eUT-P20, UT-P21, UT-V23 — high-voltage passive probes\u003c\/li\u003e\n\u003cli\u003eUT-P30, UT-P31, UT-P32, UT-P33 — differential probes for floating measurements\u003c\/li\u003e\n\u003cli\u003eUT-P40, UT-P41, UT-P42, UT-P43, UT-P44 — current probes for power-stage and switching-loss measurement\u003c\/li\u003e\n\u003cli\u003eUT-ISOT — isolation transformer for safe line-powered measurements\u003c\/li\u003e\n\u003cli\u003eUT-M13X — oscilloscope demo board for protocol decoding practice and curriculum modules\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eNeed an integrated signal generator and Bode plot analysis? See the MSO1254HD-S. Need a 150 MHz value-tier option? See the MSO1154HD.\u003c\/p\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch4\u003eFAQ's\u003c\/h4\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003ch3 class=\"product-faq-question\"\u003eWhat protocols are included with the MSO1254HD?\u003c\/h3\u003e\n\u003cp\u003eRS-232\/UART, I²C, SPI, RS-422, RS-485, CAN, CAN-FD, LIN, and Audio decoding are included standard at no additional cost. All supported protocols are available out of the box — no optional licenses required.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003ch3 class=\"product-faq-question\"\u003e\n\u003cbr\u003eWhat is the advantage of native 12-bit resolution?\u003c\/h3\u003e\n\u003cp\u003eA 12-bit ADC provides 4,096 vertical levels compared to 256 for an 8-bit scope — sixteen times greater detail. This reveals small signals riding on large ones, reduces quantization noise, and improves measurement accuracy on low-amplitude signals like power-supply ripple, sensor outputs, and precision analog circuits. R12™ holds the 12-bit resolution at the full bandwidth and sample rate, with no ERES averaging or sample-rate trade-off.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003ch3 class=\"product-faq-question\"\u003e\n\u003cbr\u003eCan I add digital channels for mixed-signal debugging?\u003c\/h3\u003e\n\u003cp\u003eYes. The UT-M26 logic probe pod adds 16 digital channels for time-correlated analog and digital views.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003ch3 class=\"product-faq-question\"\u003e\n\u003cbr\u003eDoes this model include a signal generator?\u003c\/h3\u003e\n\u003cp\u003eNo. For an integrated 1-channel 25 MHz AWG with Bode plot analysis, see the MSO1254HD-S.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003ch3 class=\"product-faq-question\"\u003e\n\u003cbr\u003eHow does the MSO1254HD compare to the higher-bandwidth UPO2000HD or MSO3000HD scopes?\u003c\/h3\u003e\n\u003cp\u003eThe MSO1000HD platform shares the same R12™ 12-bit ADC architecture, Ultra Phosphor 3.0 acquisition, and standard-included protocol decoding as the UPO2000HD and MSO3000HD families. The differences are bandwidth (150–250 MHz here vs 100–500 MHz on UPO2000HD and 350–1000 MHz on MSO3000HD), capture rate (1,000,000 wfms\/s here vs 1,500,000 wfms\/s on MSO3000HD), and the front-panel form factor. For embedded prototyping and mid-tier power-electronics work, the MSO1000HD platform delivers the same architectural advantages at a lower price point.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003ch3 class=\"product-faq-question\"\u003e\n\u003cbr\u003eIs the firmware field-upgradable?\u003c\/h3\u003e\n\u003cp\u003eYes. Firmware updates are free over the product's lifetime and install via USB drive or LAN transfer. Optional license unlocks (such as the LA16 logic-analyzer license, when ordered with the UT-M26 pod) have no expiration.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4\u003eVideos\u003c\/h4\u003e\n\u003cp\u003e\u003ciframe title=\"YouTube video player\" src=\"https:\/\/www.youtube.com\/embed\/aambUMpF_ZI?si=PRi7LQwe62SyC7bX\" height=\"315\" width=\"560\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Uni-Trend US","offers":[{"title":"181100300120X","offer_id":54423245422816,"sku":"181100300120X","price":809.0,"currency_code":"USD","in_stock":true},{"title":"181100300133X","offer_id":54423245455584,"sku":"181100300133X","price":809.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/MSO1254HD-S_3_sq.jpg?v=1782858082"},{"product_id":"ut-p32-50-mhz-100-1-1000-1-differential-oscilloscope-probe","title":"UT-P32 50 MHz 100:1\/1000:1 Differential Oscilloscope Probe","description":"\u003ch1\u003e50 MHz differential oscilloscope probe (100:1\/1000:1 attenuation) for safely measuring floating voltages across motor drives, power converters and bridge circuits.\u003c\/h1\u003e\n\u003cp\u003e\u003cstrong\u003eCompatible with UNI-T oscilloscopes and most oscilloscopes with BNC inputs.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e50MHz Bandwidth\u003c\/strong\u003e — Captures signal content up to 50MHz for accurate waveform measurement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e100:1\/1000:1 Attenuation\u003c\/strong\u003e — Attenuation ratio suited to the probe measurement range.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e3000Vpp Maximum Input Voltage\u003c\/strong\u003e — Rated input voltage for safe operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard BNC Connection\u003c\/strong\u003e — Compatible with UNI-T oscilloscopes and most oscilloscopes with BNC inputs.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCAT Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCAT III\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e69 × 26 × 165 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBandwidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe Attenuation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100:1, 1000:1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe Max Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3000Vpp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRise Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ 7ns\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Capacitance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 pF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Impedance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 MΩ \/ 1 pF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 °C - 50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDifferential Input Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3000Vpp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommon Mode Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5kVrms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCMRR\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 80 dB @ 50 Hz, \u0026gt; 60 dB @ 100 kHz, \u0026gt; 50 dB @ 1 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Uni-Trend US","offers":[{"title":"Default Title","offer_id":53265476452576,"sku":"190500300027X","price":860.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/UT-P32_1_sq.jpg?v=1782858082"},{"product_id":"mso3054hd-500-mhz-4ch-12-bit-mixed-signal-oscilloscope","title":"MSO3054HD 500 MHz 4Ch 12-Bit Mixed Signal Oscilloscope","description":"\u003cdiv class=\"product-container\"\u003e\n\u003ch1\u003eThe MSO3054HD is a 500 MHz, four-channel mixed signal oscilloscope built around UNI-T's R12™ native 12-bit ADC architecture, delivering true 12-bit acquisition at the full 500 MHz bandwidth with a 2.5 GSa\/s real-time sample rate, 500 Mpts of acquisition memory per channel and an exceptionally low 70 µVrms noise floor.\u003c\/h1\u003e\n\u003cp\u003eUltra Phosphor 3.0 acquisition provides waveform capture rates up to \u003cstrong\u003e500,000 wfms\/s standard\u003c\/strong\u003e (1,500,000 wfms\/s in Sequential Mode), while the optional \u003cstrong\u003eUT-M15\u003c\/strong\u003e logic probe expands the platform with 16 digital channels for time-correlated mixed-signal debugging. A 10.1-inch capacitive multi-touch display, built-in WebServer, and comprehensive SCPI support complete a nine-in-one engineering platform that combines oscilloscope, logic analyzer, spectrum analyzer, arbitrary waveform generator, Bode plot analyzer, protocol analyzer, digital voltmeter, frequency counter, and power analyzer (some functions require optional licenses or hardware).\u003c\/p\u003e\n\u003cp\u003eFor \u003cstrong\u003ehigh-speed embedded development, GaN and SiC power-electronics characterization, mixed-signal validation, RF troubleshooting, and advanced laboratory research\u003c\/strong\u003e, the MSO3054HD is the flagship of the MSO3000HD family. Its combination of \u003cstrong\u003e500 MHz bandwidth\u003c\/strong\u003e, native \u003cstrong\u003e12-bit vertical resolution\u003c\/strong\u003e, \u003cstrong\u003e70 µVrms noise floor\u003c\/strong\u003e, and \u003cstrong\u003e500 Mpts memory depth\u003c\/strong\u003e captures fast switching transients and low-level analog detail in the same acquisition without sacrificing bandwidth or sample rate. Optional dual-channel AWG, Bode plot analysis, advanced protocol decoding, and integrated power-analysis tools allow the MSO3054HD to consolidate multiple laboratory instruments into a single platform for design validation, signal-integrity analysis, and automated test applications.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e500 MHz Bandwidth, 4 Analog Channels + 16 Digital (Optional)\u003c\/strong\u003e — Four analog channels deliver the full 500 MHz bandwidth with a calculated rise time of ≤0.80 ns, 2.5 GSa\/s real-time sample rate, and an industry-leading 70 µVrms noise floor. Add the optional UT-M15 logic probe for 16 time-correlated digital channels with mixed-signal triggering and analysis.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eR12™ Native 12-Bit ADC\u003c\/strong\u003e — UNI-T's native 12-bit acquisition architecture provides 4,096 vertical levels at the full 500 MHz bandwidth and sample rate without enhanced-resolution averaging or bandwidth reduction. Optional ERES processing extends effective resolution to 16 bits on suitable signals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e2.5 GSa\/s Sample Rate, 500 Mpts Memory, Ultra Phosphor 3.0\u003c\/strong\u003e — Real-time sampling up to 2.5 GSa\/s with 500 Mpts of memory per channel captures long-duration events without sacrificing timing resolution. Ultra Phosphor 3.0 acquisition delivers up to 500,000 wfms\/s standard and 1,500,000 wfms\/s in Sequential Mode with 256-level intensity grading.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNine Instruments in One\u003c\/strong\u003e — Oscilloscope, logic analyzer (optional UT-M15), enhanced FFT spectrum analyzer, dual-channel arbitrary waveform generator (optional), digital voltmeter, hardware frequency counter, Bode plot analyzer, protocol analyzer, and power analyzer combine into a single laboratory platform.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e16 Digital Channels (Optional)\u003c\/strong\u003e — The optional UT-M15 logic probe activates 16 digital channels with 1.25 GSa\/s sampling, time-correlated acquisition, mixed-signal triggering, and simultaneous analog\/digital analysis.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e12 Protocol Decode Options\u003c\/strong\u003e — Standard decoding includes RS-232\/UART, RS-422\/485, I²C, SPI, and CAN. Optional licenses add CAN-FD, LIN, FlexRay, SENT, Audio, MIL-STD-1553B, ARINC 429, and Manchester protocol analysis.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOptional Dual-Channel AWG \u0026amp; Bode Plot Analysis\u003c\/strong\u003e — Optional 16-bit, dual-channel 50 MHz arbitrary waveform generator integrates with Bode plot analysis for closed-loop frequency-response and control-system validation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnhanced FFT \u0026amp; Advanced Measurements\u003c\/strong\u003e — Standard 4 Mpts FFT with waterfall display, 54 automated measurements, histogram and trend analysis, hardware mask testing, and real-time statistical measurements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e10.1-Inch Multi-Touch Display with WebServer\u003c\/strong\u003e — 1280 × 800 capacitive touchscreen with gesture navigation, built-in WebServer, SCPI automation, USB 3.0, LAN, HDMI, and comprehensive remote-control support.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eR12™ Native 12-Bit ADC — Full Resolution at 500 MHz\u003c\/h3\u003e\n\u003cp\u003eThe MSO3054HD is built around UNI-T's R12™ native 12-bit ADC architecture, delivering 4,096 vertical quantization levels across the full 500 MHz bandwidth at the full 2.5 GSa\/s sample rate. Unlike oscilloscopes that rely on enhanced-resolution averaging or digital filtering to improve vertical performance, R12™ maintains full bandwidth without sacrificing acquisition speed or timing accuracy.\u003c\/p\u003e\n\u003cp\u003eCombined with the industry's exceptionally low 70 µVrms noise floor, the MSO3054HD resolves low-level analog content alongside fast switching transitions, making it well suited for wide-bandgap power electronics, precision analog design, RF troubleshooting, and signal-integrity validation. Optional ERES processing extends effective resolution to 16 bits on appropriate band-limited signals.\u003c\/p\u003e\n\u003ch3\u003eUltra Phosphor 3.0 — Up to 1,500,000 Waveforms per Second\u003c\/h3\u003e\n\u003cp\u003eUltra Phosphor 3.0 combines high-speed FPGA acquisition with 256-level grayscale waveform mapping to expose intermittent faults and low-probability events. Continuous acquisition operates at up to 500,000 waveforms per second, while Sequential Mode increases acquisition performance to 1,500,000 wfms\/s using segmented memory triggered on qualifying events.\u003c\/p\u003e\n\u003cp\u003eUp to 125,000 waveform frames can be recorded continuously for replay and post-acquisition analysis, allowing engineers to isolate elusive timing violations, startup anomalies, communication faults, and transient switching events that conventional oscilloscopes frequently miss.\u003c\/p\u003e\n\u003ch3\u003eNine Instruments in One Platform\u003c\/h3\u003e\n\u003cp\u003eThe MSO3054HD combines nine laboratory instruments into one integrated platform: high-resolution oscilloscope, optional 16-channel logic analyzer, optional dual-channel arbitrary waveform generator, enhanced FFT spectrum analyzer, digital voltmeter, hardware frequency counter, Bode plot analyzer, protocol analyzer, and optional power-analysis suite.\u003c\/p\u003e\n\u003cp\u003eSharing one acquisition engine across every measurement function simplifies workflow while eliminating instrument synchronization, additional cabling, and multiple calibration cycles.\u003c\/p\u003e\n\u003ch3\u003eDeep Memory — 500 Mpts Per Channel\u003c\/h3\u003e\n\u003cp\u003eThe MSO3054HD provides up to 500 Mpts of acquisition memory per channel, allowing long-duration events to be captured without reducing sample rate. Engineers can record complete startup sequences, long protocol transactions, switching-converter transients, and extended validation tests while maintaining full timing resolution throughout the capture.\u003c\/p\u003e\n\u003cp\u003eSelectable memory depths from 25 kpts through 500 Mpts allow acquisition performance to be optimized for each measurement without compromising waveform fidelity.\u003c\/p\u003e\n\u003ch3\u003eMixed-Signal Analysis — 16 Optional Digital Channels\u003c\/h3\u003e\n\u003cp\u003eThe MSO3054HD supports 16 integrated digital acquisition channels activated through the optional UT-M15 logic probe. Digital sampling reaches 1.25 GSa\/s with minimal loading on the device under test, providing accurate timing correlation between digital logic and analog waveforms.\u003c\/p\u003e\n\u003cp\u003eMixed-signal triggering and synchronized acquisition simplify debugging where firmware behavior, digital communications, and analog circuitry interact, allowing both domains to be viewed and analyzed on a common time base.\u003c\/p\u003e\n\u003ch3\u003eProtocol Analysis — Twelve Bus Types\u003c\/h3\u003e\n\u003cp\u003eThe MSO3054HD supports twelve protocol decoding options covering embedded, industrial, automotive, audio, and aerospace applications. Standard decoding includes RS-232\/UART, RS-422\/485, I²C, SPI, and CAN, while optional licenses add CAN-FD, LIN, FlexRay, SENT, Audio, MIL-STD-1553B, ARINC 429, and Manchester.\u003c\/p\u003e\n\u003cp\u003eProtocol-aware triggering, event search, frame decoding, and overlay display allow communication traffic to be analyzed alongside analog and digital waveforms, accelerating root-cause analysis during system validation.\u003c\/p\u003e\n\u003ch3\u003eEnhanced FFT Spectrum Analyzer — Up to 4 Mpts\u003c\/h3\u003e\n\u003cp\u003eThe integrated spectrum analyzer performs enhanced FFT analysis using up to 4 Mpts with frequency coverage extending to 2.5 GHz. Multiple detection modes, simultaneous trace display, waterfall visualization, and automatic or manual markers support harmonic analysis, EMI investigation, clock characterization, and RF troubleshooting directly on the oscilloscope.\u003c\/p\u003e\n\u003cp\u003eTime-domain and frequency-domain analysis remain synchronized within the same acquisition, eliminating the need for separate spectrum-analyzer measurements.\u003c\/p\u003e\n\u003ch3\u003eOptional Power Analysis \u0026amp; Bode Plot Suite\u003c\/h3\u003e\n\u003cp\u003eThe optional Power Analysis package adds six specialized measurement classes, including switching loss, output ripple, harmonic analysis, slew rate, modulation analysis, and safe operating area evaluation. Combined with the optional dual-channel arbitrary waveform generator, the MSO3054HD also performs closed-loop Bode plot analysis for power-supply compensation and control-system verification.\u003c\/p\u003e\n\u003cp\u003eTogether, these options transform the oscilloscope into a comprehensive power-electronics development platform capable of measuring stimulus, response, efficiency, and switching performance from a single instrument.\u003c\/p\u003e\n\u003ch3\u003eAutomated Measurements, Statistics \u0026amp; Mask Testing\u003c\/h3\u003e\n\u003cp\u003eFifty-four automated measurements operate continuously across voltage, timing, frequency, and waveform parameters with statistical analysis, histograms, and trend displays. Up to 27 measurements may be displayed simultaneously, while snapshot mode provides detailed single-channel summaries for documentation and production testing.\u003c\/p\u003e\n\u003cp\u003eHardware mask testing enables rapid pass\/fail validation with configurable limits, making the MSO3054HD equally suited for engineering development and manufacturing environments.\u003c\/p\u003e\n\u003ch3\u003e10.1-Inch Multi-Touch Interface, WebServer \u0026amp; SCPI Automation\u003c\/h3\u003e\n\u003cp\u003eThe 10.1-inch 1280 × 800 capacitive touchscreen supports intuitive gesture-based operation alongside dedicated front-panel controls, mouse, and keyboard input. Integrated WebServer functionality enables browser-based remote operation from PCs, tablets, and smartphones without additional software installation.\u003c\/p\u003e\n\u003cp\u003eUSB 3.0, LAN, HDMI, AUX, and standard SCPI command support simplify automated testing, remote laboratories, and production integration, while free firmware updates ensure continued platform enhancements throughout the product lifecycle.\u003c\/p\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBandwidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChannels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 Analog + 16 Digital (optional UT-M15 probe)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSample Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.5 GSa\/s (interleave) \/ 1.25 GSa\/s (non-interleave)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVertical Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12-bit (up to 16-bit with ERES)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMemory Depth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 Mpts maximum per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCapture Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500,000 wfms\/s standard; 1,500,000 wfms\/s in Sequential Mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCalculated Rise Time (Typ.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤0.80 ns\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBackground Noise (full BW, Typ.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e70 µVrms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10.1 inches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1280 × 800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTouch Screen\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCapacitive multi-touch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrigger Modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEdge, Pulse Width, Video, Slope, Runt, Over-Amplitude, Delay, Timeout, Duration, Setup \u0026amp; Hold, Nth Edge, Pattern, Zone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtocol Decoders — Standard\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRS-232\/UART, RS-422\/485, I²C, SPI, CAN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtocol Decoders — Optional\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCAN-FD, LIN, FlexRay, SENT, Audio, MIL-STD-1553B, ARINC 429, Manchester\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFFT (Spectrum Analyzer)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 4 Mpts; 0 to 2.5 GHz; 4 traces, 4 detections, waterfall\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Analysis (Optional)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 classes: switching loss, ripple, harmonics, slew rate, modulation, SOA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBuilt-In AWG (Optional)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 MHz dual-channel, 16-bit, 250 MSa\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBode Plot (with AWG option)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 Hz to 50 MHz, 1–1000 points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDVM\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4-digit; DC, AC RMS, AC+DC RMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency Counter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7-digit hardware\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAutomated Measurements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e54 types; up to 27 simultaneous on-screen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSequential Mode Frames\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 125,000 frames\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSB 3.0 Host, USB Device, LAN, HDMI, AUX (Trig Out \/ Pass-Fail \/ DVM), Gen Out × 2, 10 MHz In\/Out, EXT Trig\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRemote Control\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWebServer (browser-based), SCPI over USB \/ LAN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCE, cETLus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch4\u003eDownloads\u003c\/h4\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cbr\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cstrong\u003e\u003ca rel=\"noopener\" title=\"MSO3000HD Series Datasheet\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/MSO3000HD_-_Data_Sheet_-_V1.2.pdf\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/pdf-icon-63x63_480x480.png\" style=\"float: left;\" alt=\"PDF\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/850009-i.pdf\" target=\"_blank\"\u003e\u003cbr\u003e\u003c\/a\u003e\u003ca rel=\"noopener\" title=\"UNI-T MSO3000HD Series Datasheet\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/MSO3000HD_-_Data_Sheet_-_V1.2.pdf\" target=\"_blank\"\u003eUNI-T MSO3000 Series Datasheet\u003c\/a\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cbr\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cstrong\u003e\u003ca rel=\"noopener\" title=\"UNI-T UPO1000 Series Users Manual\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/UPO1000_-_User_Manual_-_V1.0.pdf?v=1782927452\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/pdf-icon-63x63_480x480.png\" style=\"float: left;\" alt=\"PDF\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/850009-i.pdf\" target=\"_blank\"\u003e\u003cbr\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/UPO1000_-_User_Manual_-_V1.0.pdf\" title=\"UN I-T UPO1000 Series Users Manual\" rel=\"noopener\" target=\"_blank\"\u003eUNI-T MSO3000 Series Users Manual\u003c\/a\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4\u003eFAQ's\u003c\/h4\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003ch3 class=\"product-faq-question\"\u003eWhat protocols are included standard, and what are optional?\u003c\/h3\u003e\n\u003cp\u003eStandard decoders: RS-232\/UART, RS-422\/485, I²C, SPI, and CAN. Optional license unlocks: CAN-FD, LIN, FlexRay, SENT, Audio, MIL-STD-1553B, ARINC 429, and Manchester. Optional licenses do not expire; firmware updates are free over the product’s lifetime.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003ch3 class=\"product-faq-question\"\u003eWhat does R12™ mean in practice?\u003c\/h3\u003e\n\u003cp\u003eR12™ is UNI-T’s native 12-bit ADC architecture — 4,096 vertical quantization levels, sixteen times the resolution of an 8-bit ADC, held at the full bandwidth and sample rate with no ERES averaging required. ERES is available as an enhancement on top of R12 (up to 16-bit effective resolution); on competing scopes, ERES is required to claim 12-bit at all and trades bandwidth or sample rate to do it.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003ch3 class=\"product-faq-question\"\u003eCan I add the AWG and logic-analyzer capabilities later?\u003c\/h3\u003e\n\u003cp\u003eYes. The 16-channel logic analyzer is hardware-standard; activating it requires the optional UT-M15 logic probe pod. The 50 MHz dual-channel AWG (with Bode plot) is a license unlock. Both are field-upgradable on instruments already in service. License unlocks do not expire.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003ch3 class=\"product-faq-question\"\u003eWhat’s the difference between the standard 500,000 wfms\/s and Sequential Mode’s 1,500,000 wfms\/s?\u003c\/h3\u003e\n\u003cp\u003e500,000 wfms\/s is the continuous capture rate the instrument sustains across normal operation. Sequential Mode is a segmented-memory acquisition mode that conditions captures on a trigger event and uses the memory budget to record up to 125,000 frames of trigger-aligned waveforms back-to-back; the 1,500,000 wfms\/s figure is the effective capture rate during Sequential Mode operation. Sequential Mode is the right tool for hunting rare or intermittent events; the standard mode is the right tool for continuous monitoring.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003ch3 class=\"product-faq-question\"\u003eHow does the MSO3054HD compare to the X-Force MSO3054X?\u003c\/h3\u003e\n\u003cp\u003eThe MSO3054HD and the MSO3054X share the 500 MHz bandwidth and 4-channel chassis, but they target different work. The MSO3054HD is HD-tier: native 12-bit resolution, 70 µVrms noise floor, and 500 Mpts memory — built for measurement work where vertical resolution and noise floor drive the decision. The MSO3054X is X-Force-tier: 8-bit ADC at 5 GSa\/s with 1 Gpts memory and Sequential Mode for trigger-conditioned high-speed capture — built for work where sample rate and capture depth dominate. For wide-bandgap power-electronics validation and small-lab consolidation, choose HD. For high-rep-rate signal-integrity work and protocol stress testing, choose X-Force.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4\u003eOptions \u0026amp; Accessories\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eIncluded in box:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePower cord\u003c\/li\u003e\n\u003cli\u003eUSB3.0 printing cable\u003c\/li\u003e\n\u003cli\u003eEnglish download guide\u003c\/li\u003e\n\u003cli\u003emulti-language safety manual\u003c\/li\u003e\n\u003cli\u003ecalibration report (COC)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSoftware Options\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMSO3000HD-ARINC429 — Aerospace ARINC429 Serial Bus Trigger and Analysis\u003c\/li\u003e\n\u003cli\u003eMSO3000HD-AUDIO — Serial Bus Trigger and Analysis Option (I2S, LJ, RJ, TDM)\u003c\/li\u003e\n\u003cli\u003eMSO3000HD-AUTO — Serial Bus Trigger and Decode Bundle (CAN, CAN-FD, LIN, FlexRay, SENT)\u003c\/li\u003e\n\u003cli\u003eMSO3000HD-AWG — Arbitrary Waveform Generator option\u003c\/li\u003e\n\u003cli\u003eMSO3000HD-BND — Serial Bus Trigger and Decode Bundle (incl. AUTO, AUDIO, MIL-STD, ARINC429, MANCH)\u003c\/li\u003e\n\u003cli\u003eMSO3000HD-BW2MT3M5 — 350MHz Bandwidth Upgrade\u003c\/li\u003e\n\u003cli\u003eMSO3000HD-CAN — Automotive CAN Serial Bus Trigger and Analysis\u003c\/li\u003e\n\u003cli\u003eMSO3000HD-CANFD — Automotive CAN-FD Serial Bus Trigger and Analysis\u003c\/li\u003e\n\u003cli\u003eMSO3000HD-FLEX — Automotive FlexRay Serial Bus Trigger and Analysis\u003c\/li\u003e\n\u003cli\u003eMSO3000HD-LIN — Automotive LIN Serial Bus Trigger and Analysis\u003c\/li\u003e\n\u003cli\u003eMSO3000HD-MANCH — Manchester Serial Bus Trigger and Analysis Option\u003c\/li\u003e\n\u003cli\u003eMSO3000HD-MIL1553 — MIL-STD-1553 Serial Bus Trigger and Analysis Option\u003c\/li\u003e\n\u003cli\u003eMSO3000HD-PWR — Power Analysis Option\u003c\/li\u003e\n\u003cli\u003eMSO3000HD-SENT — Automotive SENT Sensor Bus Trigger and Analysis\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eVideos\u003c\/h4\u003e\n\u003cp\u003e\u003ciframe width=\"560\" height=\"315\" src=\"https:\/\/www.youtube.com\/embed\/L7EsLFmrOdc?si=DPVM5we2xDcnXUmo\" title=\"YouTube video player\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e","brand":"Uni-Trend US","offers":[{"title":"181100300072X","offer_id":53265476485344,"sku":"181100300072X","price":3119.2,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/MSO3054HD_1_sq.jpg?v=1782858083"},{"product_id":"upo2104hd-100-mhz-4ch-12-bit-high-resolution-oscilloscope","title":"UPO2104HD 100 MHz 4Ch 12-Bit High-Resolution Oscilloscope","description":"\u003ch1\u003eThe UNI-T UPO2104HD is a 100 MHz, four-channel, 12-bit high-resolution digital storage oscilloscope built around UNI-T's native **R12™** ADC architecture, engineered for embedded systems development, power electronics, analog design and mixed-signal debugging.\u003c\/h1\u003e\n\u003cp\u003eWith a 2.5 GSa\/s real-time sample rate, 100 Mpts of standard acquisition memory, Ultra Phosphor 3.0 waveform mapping at up to 1,000,000 wfms\/s in Sequence mode, a 10.1-inch capacitive multi-touch display, built-in WebServer remote control, and enhanced FFT analysis to 4 Mpts, the UPO2104HD combines six essential bench instruments into a single platform: oscilloscope, spectrum analyzer, digital voltmeter, hardware frequency counter, protocol analyzer, and optional power analyzer.\u003c\/p\u003e\n\u003cp\u003eFor embedded development, switching power-supply design, multi-rail power validation, and general-purpose R\u0026amp;D where measurement resolution matters more than raw bandwidth, the UPO2104HD delivers **4,096 vertical levels at the full 100 MHz bandwidth** without enhanced-resolution averaging or sample-rate penalties. Four analog channels allow simultaneous observation of switching nodes, gate-drive signals, output rails, and control circuitry, while nine standard protocol decoders, 56 automated measurements, hardware mask testing, zone triggering, and optional 12-parameter power analysis provide a complete workflow for hardware bring-up, protocol debugging, and power-converter validation in a single instrument.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e100 MHz Bandwidth, 4 Analog Channels\u003c\/strong\u003e — Four-channel acquisition with 100 MHz bandwidth, 2.5 GSa\/s real-time sample rate, and 100 Mpts standard memory depth. Native 12-bit acquisition preserves 4,096 vertical levels across the full bandwidth with no enhanced-resolution averaging or sample-rate compromise.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eR12™ Native 12-Bit ADC\u003c\/strong\u003e — UNI-T's R12™ architecture delivers true 12-bit resolution at full bandwidth and sample rate, providing sixteen times the vertical resolution of conventional 8-bit oscilloscopes for low-level signal, ripple, and precision analog measurements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eUltra Phosphor 3.0 — Up to 1,000,000 wfms\/s\u003c\/strong\u003e — High-speed acquisition with continuous waveform update rates up to 250,000 wfms\/s and Sequence mode reaching 1,000,000 wfms\/s. 256-level intensity grading exposes rare glitches, timing violations, and intermittent events conventional oscilloscopes often miss.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e100 Mpts Standard Memory\u003c\/strong\u003e — Deep acquisition memory captures long-duration events while maintaining full sample rate, supporting extended transient analysis, startup sequences, burst-mode operation, and protocol debugging without sacrificing timing resolution.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSix Instruments in One\u003c\/strong\u003e — Oscilloscope, enhanced FFT spectrum analyzer, digital voltmeter, hardware frequency counter, protocol analyzer, and optional 12-parameter power-analysis suite consolidate multiple laboratory instruments into a single platform.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNine Protocol Decoders Standard\u003c\/strong\u003e — RS-232\/UART, I²C, SPI, CAN, CAN-FD, LIN, FlexRay, SENT, and Audio decoding with integrated triggering, event search, and protocol-aware analysis included standard without license activation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnhanced FFT \u0026amp; Advanced Measurements\u003c\/strong\u003e — Standard 4 Mpts FFT, waterfall display, 56 automated measurements with statistics, hardware mask testing, zone triggering, and up to 4-bit ERES enhanced-resolution processing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e10.1-Inch Capacitive Touchscreen\u003c\/strong\u003e — 1280 × 800 multi-touch display with pinch-to-zoom, drag, rectangle selection, gesture navigation, plus simultaneous mouse and keyboard support.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWebServer, SCPI \u0026amp; Modern Connectivity\u003c\/strong\u003e — USB Host, USB Device, LAN, HDMI, EXT Trigger, AUX Out, built-in WebServer, and standard SCPI remote control support automated testing and browser-based instrument operation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eR12™ Native 12-Bit ADC — Full Resolution at Full Bandwidth\u003c\/h3\u003e\n\u003cp\u003eThe UPO2104HD is built around UNI-T's R12™ native 12-bit ADC architecture, delivering 4,096 quantization levels across the full 100 MHz bandwidth at the full 2.5 GSa\/s sample rate. Unlike oscilloscopes that rely on enhanced-resolution averaging to improve vertical performance, R12™ maintains full bandwidth, sample rate, and acquisition performance without mathematical processing or acquisition compromises.\u003c\/p\u003e\n\u003cp\u003eFor power electronics, embedded development, precision analog design, and sensor characterization, the additional vertical resolution reveals ripple, switching artifacts, and low-amplitude analog behavior that conventional 8-bit oscilloscopes often bury in quantization noise.\u003c\/p\u003e\n\u003ch3\u003eUltra Phosphor 3.0 — Up to 1,000,000 Waveforms per Second\u003c\/h3\u003e\n\u003cp\u003eUltra Phosphor 3.0 combines high-speed acquisition with 256-level grayscale intensity mapping to reveal intermittent waveform behavior in real time. Continuous acquisition reaches 250,000 wfms\/s, while Sequence mode increases capture performance to 1,000,000 wfms\/s for trigger-qualified events.\u003c\/p\u003e\n\u003cp\u003eThe acquisition engine combines high trigger sensitivity, low trigger jitter, and hardware zone triggering to isolate non-repetitive events. Density-graded waveform persistence makes runts, glitches, timing violations, and intermittent protocol errors visible long before they become reproducible failures.\u003c\/p\u003e\n\u003ch3\u003eSix Instruments in One Platform\u003c\/h3\u003e\n\u003cp\u003eThe UPO2104HD integrates six laboratory instruments into one bench platform: high-resolution oscilloscope, enhanced FFT spectrum analyzer, digital voltmeter, hardware frequency counter, protocol analyzer, and optional power-analysis suite.\u003c\/p\u003e\n\u003cp\u003eWith four analog channels available to every measurement engine, users can perform multi-rail power validation, protocol correlation, spectrum analysis, and precision waveform measurements simultaneously without switching instruments or reconnecting probes.\u003c\/p\u003e\n\u003ch3\u003eDeep Memory — 100 Mpts Standard\u003c\/h3\u003e\n\u003cp\u003eThe UPO2104HD includes 100 Mpts of acquisition memory as standard equipment. At the full 2.5 GSa\/s sample rate, this provides approximately 40 ms of continuous full-resolution acquisition, allowing complete startup sequences, fault recovery events, communication bursts, and long transient behavior to be captured in a single acquisition.\u003c\/p\u003e\n\u003cp\u003eCombined with uninterrupted recording of up to 125,000 waveform frames, hardware mask testing, and enhanced-resolution processing, the deep memory architecture allows engineers to analyze extended events without sacrificing timing resolution.\u003c\/p\u003e\n\u003ch3\u003eNine Protocol Decoders Included Standard\u003c\/h3\u003e\n\u003cp\u003eNine serial-bus protocol decoders are included with every UPO2104HD: RS-232\/UART, I²C, SPI, CAN, CAN-FD, LIN, FlexRay, SENT, and Audio.\u003c\/p\u003e\n\u003cp\u003eEach protocol supports hardware triggering, decoding, searchable event lists, and synchronized analog correlation. Engineers can align decoded protocol traffic directly with analog waveforms, simplifying root-cause analysis of communication failures caused by power-supply disturbances, signal-integrity issues, or timing violations. All protocol options are included standard with no additional license purchases.\u003c\/p\u003e\n\u003ch3\u003eOptional 12-Parameter Power Analysis\u003c\/h3\u003e\n\u003cp\u003eThe optional power-analysis package extends the UPO2104HD with twelve specialized power-electronics measurements, including power quality, harmonic analysis, current harmonics, RDS(on), switching loss, slew rate, safe operating area, modulation analysis, output ripple, startup and shutdown timing, transient response, and efficiency.\u003c\/p\u003e\n\u003cp\u003eThe integrated analysis eliminates the need for external post-processing, allowing designers to move directly from waveform acquisition to engineering measurements during switching-converter development and validation.\u003c\/p\u003e\n\u003ch3\u003eEnhanced FFT Spectrum Analyzer — Up to 4 Mpts\u003c\/h3\u003e\n\u003cp\u003eThe built-in enhanced FFT provides frequency-domain analysis using up to 4 Mpts FFT length with waterfall display, multiple trace views, and automatic or manual marker functions.\u003c\/p\u003e\n\u003cp\u003eEngineers can quickly identify switching harmonics, clock spurs, EMI sources, and spectral artifacts directly on the oscilloscope without transferring waveform data to external software, streamlining pre-compliance investigation and mixed-domain debugging.\u003c\/p\u003e\n\u003ch3\u003eAutomated Measurements, Statistics \u0026amp; Mask Testing\u003c\/h3\u003e\n\u003cp\u003eFifty-six automated measurements operate continuously across all channels with statistical analysis, histograms, trend charts, and snapshot displays. Enhanced amplitude algorithms improve measurement accuracy on burst-mode and complex waveforms where conventional measurement engines often produce misleading results.\u003c\/p\u003e\n\u003cp\u003eHardware-accelerated mask testing provides rapid pass\/fail validation for production testing, design verification, and long-duration stability testing.\u003c\/p\u003e\n\u003ch3\u003e10.1-Inch Touch Interface with WebServer Connectivity\u003c\/h3\u003e\n\u003cp\u003eThe UPO2104HD features a 10.1-inch 1280 × 800 capacitive multi-touch display supporting pinch, zoom, drag, rectangle selection, and gesture-based waveform navigation alongside traditional front-panel controls. Mouse and keyboard operation are supported simultaneously.\u003c\/p\u003e\n\u003cp\u003eConnectivity includes USB Host, USB Device, LAN, HDMI, EXT Trigger, AUX Out, and standard SCPI remote control. The integrated WebServer enables browser-based operation from PCs or mobile devices without additional software installation, making the UPO2104HD equally suited for laboratory benches and automated test environments.\u003c\/p\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable style=\"width: 95.8148%;\" height=\"904\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.8781%;\"\u003e\u003cstrong\u003eBandwidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 71.7636%;\"\u003e100 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.8781%;\"\u003e\u003cstrong\u003eChannels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 71.7636%;\"\u003e4 Analog\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.8781%;\"\u003e\u003cstrong\u003eSample Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 71.7636%;\"\u003e2.5 GSa\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.8781%;\"\u003e\u003cstrong\u003eVertical Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 71.7636%;\"\u003e12 bits (R12™ native)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.8781%;\"\u003e\u003cstrong\u003eMemory Depth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 71.7636%;\"\u003e100 Mpts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.8781%;\"\u003e\u003cstrong\u003eCapture Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 71.7636%;\"\u003e1,000,000 wfms\/s (sequence mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.8781%;\"\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 71.7636%;\"\u003e10.1-inch capacitive touchscreen, 1280×800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.8781%;\"\u003e\u003cstrong\u003eTouch Screen\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 71.7636%;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.8781%;\"\u003e\u003cstrong\u003eTrigger Modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 71.7636%;\"\u003eEdge, pulse width, video, ramp, runt, over-amplitude, delay, timeout, duration, setup\/hold, Nth edge, code pattern\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.8781%;\"\u003e\u003cstrong\u003eZone Trigger\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 71.7636%;\"\u003eYes — 2 zones, must-intersect \/ must-not-intersect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.8781%;\"\u003e\u003cstrong\u003eProtocol Decoding (Standard)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 71.7636%;\"\u003eRS-232\/UART, I²C, SPI, CAN, CAN-FD, LIN, FlexRay, SENT, Audio\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.8781%;\"\u003e\u003cstrong\u003eBuilt-In FFT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 71.7636%;\"\u003eYes — up to 4 Mpts, 0 to 1.25 GHz, 4 traces, waterfall\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.8781%;\"\u003e\u003cstrong\u003eBuilt-In Power Analysis\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 71.7636%;\"\u003eOptional — 12 parameters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.8781%;\"\u003e\u003cstrong\u003eBuilt-In Spectrum Analyzer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 71.7636%;\"\u003eYes (standard FFT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.8781%;\"\u003e\u003cstrong\u003eDigital Voltmeter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 71.7636%;\"\u003e4-digit; DC, AC RMS, AC+DC RMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.8781%;\"\u003e\u003cstrong\u003eFrequency Meter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 71.7636%;\"\u003e7-digit hardware\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.8781%;\"\u003e\u003cstrong\u003eAutomated Measurements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 71.7636%;\"\u003e56 with statistics, histogram, and trend\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.8781%;\"\u003e\u003cstrong\u003eERES (Enhanced Resolution)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 71.7636%;\"\u003eUp to 4-bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.8781%;\"\u003e\u003cstrong\u003eMask Testing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 71.7636%;\"\u003eHardware-accelerated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.8781%;\"\u003e\u003cstrong\u003eWaveform Recording\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 71.7636%;\"\u003eUp to 125,000 frames; USB export\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.8781%;\"\u003e\u003cstrong\u003eInterface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 71.7636%;\"\u003eUSB Host \/ USB Device \/ LAN \/ EXT Trig \/ AUX Out \/ HDMI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.8781%;\"\u003e\u003cstrong\u003eRemote Control\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 71.7636%;\"\u003eSCPI standard; built-in WebServer (browser access)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.8781%;\"\u003e\u003cstrong\u003eRoHS Compliant\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 71.7636%;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.8781%;\"\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 71.7636%;\"\u003eCE, cETLus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eDownloads\u003c\/h4\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cbr\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/UPO2000HD_-_Data_Sheet_-_V1.1.pdf\" title=\"UPO2000 Series Datasheet\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg alt=\"PDF\" style=\"float: left;\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/pdf-icon-63x63_480x480.png\"\u003e\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/UPO2000HD_-_Data_Sheet_-_V1.1.pdf\" title=\"UNI-T UPO2000 Series Datasheet\"\u003eUNI-T UPO2000 Series Datasheet\u003c\/a\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cbr\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cstrong\u003e\u003ca rel=\"noopener\" title=\"UNI-T UPO2000 Series Users Manual\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/UPO2000HD_-_User_Manual_-_V1.1.pdf\" target=\"_blank\"\u003e\u003cimg alt=\"PDF\" style=\"float: left;\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/pdf-icon-63x63_480x480.png\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/850009-i.pdf\" target=\"_blank\"\u003e\u003cbr\u003e\u003c\/a\u003e\u003ca rel=\"noopener\" title=\"UNI-T UPO2000 Series Users Manual\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/UPO2000HD_-_User_Manual_-_V1.1.pdf\" target=\"_blank\"\u003eUNI-T UPO2000 Series Users Manual\u003c\/a\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eOptions \u0026amp; Accessories\u003c\/h4\u003e\n\u003ch3\u003eIncluded with the Instrument\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUPO2104HD oscilloscope\u003c\/li\u003e\n\u003cli\u003e4 × passive probes (1:1 \/ 10:1 switchable, bandwidth matched to instrument)\u003c\/li\u003e\n\u003cli\u003eUSB cable (USB-A to USB-B)\u003c\/li\u003e\n\u003cli\u003ePower cord (region-appropriate)\u003c\/li\u003e\n\u003cli\u003eQuick-start guide\u003c\/li\u003e\n\u003cli\u003eFactory calibration certificate\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eRecommended Accessories\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUPO2000HD-PWR — optional 12-parameter power-analysis package activation\u003c\/li\u003e\n\u003cli\u003eUT-P07A — 500 MHz passive probe for higher-bandwidth applications\u003c\/li\u003e\n\u003cli\u003eUT-P20, UT-P21, UT-V23 — high-voltage passive probes\u003c\/li\u003e\n\u003cli\u003eUT-P30, UT-P31, UT-P32, UT-P33 — differential probes for floating measurements\u003c\/li\u003e\n\u003cli\u003eUT-P40, UT-P41, UT-P42, UT-P43, UT-P44 — current probes for power-stage and switching-loss measurement\u003c\/li\u003e\n\u003cli\u003eUT-ISOT — isolation transformer for safe line-powered measurements\u003c\/li\u003e\n\u003cli\u003eUT-M13X — oscilloscope demo board for protocol decoding practice and curriculum modules\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eNeed different bandwidth or channel-count? \u003cbr\u003eAlso see: UPO2074HD, UPO2102HD, UPO2072HD.\u003c\/p\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch4\u003e\u003cstrong\u003eFAQ's\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003ch3 class=\"product-faq-question\"\u003eWhat protocols are included with the UPO2104HD?\u003c\/h3\u003e\n\u003cp\u003eRS-232\/UART, I²C, SPI, CAN, CAN-FD, LIN, FlexRay, SENT, and Audio decoding are included standard at no additional cost. All nine supported protocols are available out of the box — no optional licenses required, no time-boxed unlocks.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003ch3 class=\"product-faq-question\"\u003e\n\u003cbr\u003eWhat is the advantage of native 12-bit resolution?\u003c\/h3\u003e\n\u003cp\u003eA 12-bit ADC provides 4,096 vertical levels compared to 256 for an 8-bit scope — sixteen times greater detail. This reveals small signals riding on large ones, reduces quantization noise, and improves measurement accuracy on low-amplitude signals like power-supply ripple, sensor outputs, and precision analog circuits. R12™ holds the 12-bit resolution at the full bandwidth and sample rate, with no ERES averaging or sample-rate trade-off.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003ch3 class=\"product-faq-question\"\u003e\n\u003cbr\u003eCan I add power-supply analysis?\u003c\/h3\u003e\n\u003cp\u003eYes. The optional power-analysis package adds 12 measurements: power quality, harmonic analysis, current harmonics, R\u003csub\u003eDS(on)\u003c\/sub\u003e, switching loss, slew rate, safe operating area, modulation analysis, output ripple, startup\/shutdown time, transient response, and power efficiency. The UPO2000HD-PWR activation unlocks the package on any UPO2000HD-series oscilloscope.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003ch3 class=\"product-faq-question\"\u003e\n\u003cbr\u003eHow does the touchscreen handle daily lab use?\u003c\/h3\u003e\n\u003cp\u003eThe 10.1-inch capacitive multi-touch display supports pinch, drag, zoom, rectangle-draw, and edit gestures alongside the traditional knobs and one-touch front-panel keys. Mouse and keyboard are supported in parallel. For lab settings where students or engineers cycle through the instrument frequently, the gesture set is familiar from consumer devices; for production-style workflows where physical controls are preferred, the front panel still does what front panels do.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003ch3 class=\"product-faq-question\"\u003e\n\u003cbr\u003eHow does the UPO2104HD compare to 8-bit oscilloscopes at similar bandwidth?\u003c\/h3\u003e\n\u003cp\u003eThe 12-bit ADC delivers 16× the vertical resolution of an 8-bit scope at the same bandwidth, with no ERES averaging or sample-rate trade-off. Low-amplitude signals — switching ripple, sensor outputs, precision analog circuits — that 8-bit scopes flatten into quantization noise show up clearly on the 12-bit display. For analog precision work and switching-converter validation, the resolution advantage is structural, not a marketing comparison.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003ch3 class=\"product-faq-question\"\u003e\n\u003cbr\u003eIs the firmware field-upgradable?\u003c\/h3\u003e\n\u003cp\u003eYes. Firmware updates are free over the product's lifetime and install via USB drive or LAN transfer. Optional license unlocks (such as the power-analysis package) have no expiration.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003ch3 class=\"product-faq-question\"\u003e\n\u003cbr\u003eCan the instrument be controlled from a PC or from a browser?\u003c\/h3\u003e\n\u003cp\u003eBoth. SCPI is supported standard via USB Device or LAN for automated test scripts and PC-side instrument-management software. The built-in WebServer enables direct browser-based control from a PC or mobile device on the same network — no PC-side software install required.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cp\u003ePart of the UPO2000HD oscilloscope series. All models share the R12™ native 12-bit ADC, 2.5 GSa\/s sample rate, 100 Mpts memory, Ultra Phosphor 3.0 acquisition, and 9 standard protocol decoders. Bandwidth options span 70 \/ 100 \/ 200 MHz; channel options are 2-channel and 4-channel. See the series page to compare configurations.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch4\u003eVideos\u003c\/h4\u003e\n\u003cp\u003e\u003ciframe title=\"YouTube video player\" src=\"https:\/\/www.youtube.com\/embed\/xu5F8QnqECQ?si=YVji0wNPiXJlWaLt\" height=\"315\" width=\"560\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Uni-Trend US","offers":[{"title":"Default Title","offer_id":53265476518112,"sku":"181100200138X","price":924.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/UPO2104HD_1_sq.jpg?v=1782858083"},{"product_id":"mso1154hd-150-mhz-4ch-12-bit-mixed-signal-oscilloscope","title":"MSO1154HD 150 MHz 4Ch 12-Bit Mixed Signal Oscilloscope","description":"\u003ch1\u003eThe UNI-T MSO1154HD 150 MHz 4-Channel Mixed Signal Oscilloscope combines native 12-bit vertical resolution, four analog channels and advanced mixed-signal analysis in a compact benchtop platform designed for embedded development, power electronics, education and laboratory research.\u003c\/h1\u003e\n\u003cp\u003ePowered by UNI-T's R12™ native 12-bit ADC architecture, the MSO1154HD delivers 4,096 levels of vertical resolution at its full 150 MHz bandwidth without sacrificing sample rate, providing the measurement accuracy needed to analyze low-level signals, switching ripple, and precision analog circuits.\u003c\/p\u003e\n\u003cp\u003eWith up to 2.5 GSa\/s real-time sampling, 100 Mpts of memory per channel, Ultra Phosphor 3.0 waveform acquisition, integrated protocol decoding, FFT spectrum analysis, and optional 16-channel logic analysis, the MSO1154HD brings the capabilities of higher-end oscilloscopes into an affordable platform for engineers, educators, and advanced electronics laboratories.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e150 MHz bandwidth with four analog input channels\u003c\/li\u003e\n\u003cli\u003eNative 12-bit R12™ ADC architecture with 4,096 vertical levels\u003c\/li\u003e\n\u003cli\u003eUp to 2.5 GSa\/s real-time sampling\u003c\/li\u003e\n\u003cli\u003e100 Mpts acquisition memory per channel\u003c\/li\u003e\n\u003cli\u003eUltra Phosphor 3.0 acquisition with up to 1,000,000 waveforms per second\u003c\/li\u003e\n\u003cli\u003eOptional 16-channel mixed-signal logic analyzer (UT-M26)\u003c\/li\u003e\n\u003cli\u003eStandard protocol decoding for UART, RS-232, RS-422, RS-485, I²C, SPI, CAN, CAN-FD, LIN, and Audio buses\u003c\/li\u003e\n\u003cli\u003eBuilt-in 1 Mpts FFT spectrum analyzer\u003c\/li\u003e\n\u003cli\u003e56 automated measurements with statistical analysis\u003c\/li\u003e\n\u003cli\u003eIntegrated power analysis with 12 measurement parameters\u003c\/li\u003e\n\u003cli\u003e7-inch capacitive multi-touch display\u003c\/li\u003e\n\u003cli\u003eUSB Host, USB Device, LAN, HDMI, and AUX connectivity\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eNative 12-Bit Performance\u003c\/h2\u003e\n\u003cp\u003eBuilt around UNI-T's R12™ native 12-bit ADC architecture, the MSO1154HD delivers sixteen times the vertical resolution of conventional 8-bit oscilloscopes while maintaining its full 150 MHz bandwidth and maximum sample rate. The increased measurement resolution makes it easier to observe small voltage variations, switching ripple, sensor outputs, and low-level analog signals without relying on software averaging or reduced acquisition performance.\u003c\/p\u003e\n\u003ch2\u003eUltra Phosphor 3.0 Acquisition\u003c\/h2\u003e\n\u003cp\u003eUltra Phosphor 3.0 technology captures up to one million waveforms per second while displaying 256 levels of intensity grading, allowing frequently occurring signals to stand out while rare glitches and intermittent timing faults remain visible. Combined with deep acquisition memory, the system helps engineers identify transient events, protocol errors, and signal integrity problems that can be difficult to detect on slower oscilloscopes.\u003c\/p\u003e\n\u003ch2\u003eDeep Memory and Mixed-Signal Debugging\u003c\/h2\u003e\n\u003cp\u003eWith 100 Mpts of acquisition memory available on each analog channel, the MSO1154HD captures long signal records without sacrificing sample resolution. Engineers can analyze extended startup sequences, communication transactions, and complex embedded events while maintaining detailed waveform visibility. An optional UT-M26 logic probe adds 16 synchronized digital channels, allowing analog and digital signals to be viewed together for efficient mixed-signal debugging.\u003c\/p\u003e\n\u003ch2\u003eProtocol Decoding and Power Analysis\u003c\/h2\u003e\n\u003cp\u003eThe MSO1154HD includes one of the most comprehensive protocol decoding packages in its class, with standard support for UART, RS-232, RS-422, RS-485, I²C, SPI, CAN, CAN-FD, LIN, and Audio communication buses. Built-in power analysis measures efficiency, ripple, switching loss, and other key power-quality parameters, making the oscilloscope well suited for embedded systems, industrial controls, automotive electronics, and power supply development.\u003c\/p\u003e\n\u003ch2\u003eSpectrum Analysis and Automated Measurements\u003c\/h2\u003e\n\u003cp\u003eAn integrated FFT spectrum analyzer with up to 1 Mpts resolution enables engineers to investigate harmonics, switching frequencies, EMI sources, and clock signals without requiring a separate instrument. Fifty-six automated measurements, statistical analysis, trend displays, and pass\/fail mask testing simplify waveform characterization, production testing, and long-term performance evaluation.\u003c\/p\u003e\n\u003ch2\u003eDesigned for Modern Engineering Labs\u003c\/h2\u003e\n\u003cp\u003eA responsive 7-inch capacitive touchscreen with gesture navigation provides intuitive control of waveforms and measurements, while USB, LAN, HDMI, and AUX interfaces simplify data transfer, remote operation, and classroom demonstrations. Whether used in an engineering laboratory, university teaching environment, or electronics development bench, the MSO1154HD delivers professional measurement capability in an easy-to-use platform.\u003c\/p\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cp\u003eThe UNI-T MSO1154HD is ideal for embedded systems development, mixed-signal debugging, power electronics design, industrial automation, automotive electronics, sensor evaluation, university laboratories, technical education, and electronics repair. Its native 12-bit architecture, deep memory, integrated protocol decoding, and optional logic analysis provide engineers and educators with a versatile platform for analyzing today's increasingly complex electronic systems.\u003c\/p\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable style=\"width: 90.65%; height: 512px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 33.8134%; height: 19.5938px;\"\u003e\u003cstrong\u003eBandwidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.8283%; height: 19.5938px;\"\u003e150 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 33.8134%; height: 19.5938px;\"\u003e\u003cstrong\u003eChannels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.8283%; height: 19.5938px;\"\u003e4 Analog + 16 Optional Digital\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 33.8134%; height: 19.5938px;\"\u003e\u003cstrong\u003eSample Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.8283%; height: 19.5938px;\"\u003e2.5 GSa\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 33.8134%; height: 19.5938px;\"\u003e\u003cstrong\u003eVertical Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.8283%; height: 19.5938px;\"\u003e12 bits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 33.8134%; height: 19.5938px;\"\u003e\u003cstrong\u003eMemory Depth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.8283%; height: 19.5938px;\"\u003e100 Mpts per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 33.8134%; height: 19.5938px;\"\u003e\u003cstrong\u003eCapture Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.8283%; height: 19.5938px;\"\u003e1,000,000 wfms\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 33.8134%; height: 19.5938px;\"\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.8283%; height: 19.5938px;\"\u003e7-inch capacitive touchscreen, 1024×600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 33.8134%; height: 19.5938px;\"\u003e\u003cstrong\u003eTouch Screen\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.8283%; height: 19.5938px;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 33.8134%; height: 39.1875px;\"\u003e\u003cstrong\u003eTrigger Modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.8283%; height: 39.1875px;\"\u003eEdge, pulse width, video, runt, slope, zone, setup\/hold, and more\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 33.8134%; height: 39.1875px;\"\u003e\u003cstrong\u003eProtocol Decoding (Standard)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.8283%; height: 39.1875px;\"\u003eRS-232\/UART, I²C, SPI, RS-422, RS-485, CAN, CAN-FD, LIN, Audio\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 33.8134%; height: 19.5938px;\"\u003e\u003cstrong\u003eBuilt-In FFT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.8283%; height: 19.5938px;\"\u003eYes — up to 1 Mpts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 33.8134%; height: 19.5938px;\"\u003e\u003cstrong\u003eBuilt-In Power Analysis\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.8283%; height: 19.5938px;\"\u003e12 parameters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 33.8134%; height: 39.1875px;\"\u003e\u003cstrong\u003eBuilt-In Spectrum Analyzer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.8283%; height: 39.1875px;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 33.8134%; height: 19.5938px;\"\u003e\u003cstrong\u003eAutomated Measurements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.8283%; height: 19.5938px;\"\u003e56 with statistics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 33.8134%; height: 19.5938px;\"\u003e\u003cstrong\u003eBuilt-In AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.8283%; height: 19.5938px;\"\u003eNo (available on -S models)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 33.8134%; height: 19.5938px;\"\u003e\u003cstrong\u003eBode Plot Analysis\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.8283%; height: 19.5938px;\"\u003eNo (available on -S models)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 33.8134%; height: 19.5938px;\"\u003e\u003cstrong\u003eLogic Analyzer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.8283%; height: 19.5938px;\"\u003eOptional 16-channel via UT-M26 pod\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 33.8134%; height: 19.5938px;\"\u003e\u003cstrong\u003eInterface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.8283%; height: 19.5938px;\"\u003eUSB Host \/ USB Device \/ LAN \/ AUX Out \/ HDMI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 33.8134%; height: 19.5938px;\"\u003e\u003cstrong\u003eRoHS Compliant\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.8283%; height: 19.5938px;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4\u003eDownloads\u003c\/h4\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cbr\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/MSO1000HD_-_Data_Sheet_-_V1.0.pdf\" title=\"MSO1000HD Series Datasheet\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/pdf-icon-63x63_480x480.png\" style=\"float: left;\" alt=\"PDF\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/850009-i.pdf\" target=\"_blank\"\u003e\u003cbr\u003e\u003c\/a\u003e\u003ca title=\"UNI-T MSO1000HD Series Datasheet\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/MSO1000HD_-_Data_Sheet_-_V1.0.pdf\"\u003eUNI-T MSO1000HD Series Datasheet\u003c\/a\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cbr\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/MSO1000HD_-_User_Manual_-_V1.0.pdf\" title=\"UNI-T MSO1000HD Series Users Manual\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/pdf-icon-63x63_480x480.png\" style=\"float: left;\" alt=\"PDF\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/850009-i.pdf\" target=\"_blank\"\u003e\u003cbr\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/MSO1000HD_-_User_Manual_-_V1.0.pdf\" title=\"UNI-T MSO1000HD Series Users Manual\" rel=\"noopener\" target=\"_blank\"\u003eUNI-T MSO1000HD Series Users Manual\u003c\/a\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4\u003eOptions \u0026amp; Accessories\u003c\/h4\u003e\n\u003ch3\u003eIncluded with the Instrument\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMSO1154HD oscilloscope\u003c\/li\u003e\n\u003cli\u003e4 × passive probes (1:1 \/ 10:1 switchable, bandwidth matched to instrument)\u003c\/li\u003e\n\u003cli\u003eUSB cable (USB-A to USB-B)\u003c\/li\u003e\n\u003cli\u003ePower cord (region-appropriate)\u003c\/li\u003e\n\u003cli\u003eQuick-start guide\u003c\/li\u003e\n\u003cli\u003eFactory calibration certificate\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eRecommended Accessories\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUT-M26 — 16-channel logic probe pod for mixed-signal debugging\u003c\/li\u003e\n\u003cli\u003eUT-P07A — 500 MHz passive probe for higher-bandwidth applications\u003c\/li\u003e\n\u003cli\u003eUT-P20, UT-P21, UT-V23 — high-voltage passive probes\u003c\/li\u003e\n\u003cli\u003eUT-P30, UT-P31, UT-P32, UT-P33 — differential probes for floating measurements\u003c\/li\u003e\n\u003cli\u003eUT-P40, UT-P41, UT-P42, UT-P43, UT-P44 — current probes for power-stage and switching-loss measurement\u003c\/li\u003e\n\u003cli\u003eUT-ISOT — isolation transformer for safe line-powered measurements\u003c\/li\u003e\n\u003cli\u003eUT-M13X — oscilloscope demo board for protocol decoding practice and curriculum modules\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eNeed an integrated signal generator? See the MSO1154HD-S for the same platform with a 25 MHz AWG and Bode plot analysis added. Need 250 MHz bandwidth for power-electronics work? See the MSO1254HD.\u003c\/p\u003e\n\u003ch4\u003eFAQ's\u003c\/h4\u003e\n\u003ch3\u003eWhat protocols are included with the MSO1154HD?\u003c\/h3\u003e\n\u003cp\u003eRS-232\/UART, I²C, SPI, RS-422, RS-485, CAN, CAN-FD, LIN, and Audio decoding are included standard at no additional cost. All supported protocols are available out of the box — no optional licenses required.\u003c\/p\u003e\n\u003ch3\u003eWhat is the advantage of native 12-bit resolution?\u003c\/h3\u003e\n\u003cp\u003eA 12-bit ADC provides 4,096 vertical levels compared to 256 for an 8-bit scope — sixteen times greater detail. This reveals small signals riding on large ones, reduces quantization noise, and improves measurement accuracy on low-amplitude signals like power-supply ripple, sensor outputs, and precision analog circuits. R12™ holds the 12-bit resolution at the full bandwidth and sample rate, with no ERES averaging or sample-rate trade-off.\u003c\/p\u003e\n\u003ch3\u003eCan I add digital channels for mixed-signal debugging?\u003c\/h3\u003e\n\u003cp\u003eYes. The UT-M26 logic probe pod adds 16 digital channels for time-correlated analog and digital views.\u003c\/p\u003e\n\u003ch3\u003eDoes this model include a signal generator?\u003c\/h3\u003e\n\u003cp\u003eNo. For an integrated 1-channel 25 MHz AWG with Bode plot analysis, see the MSO1154HD-S.\u003c\/p\u003e\n\u003ch3\u003eHow does the MSO1154HD compare to the higher-bandwidth UPO2000HD or MSO3000HD scopes?\u003c\/h3\u003e\n\u003cp\u003eThe MSO1000HD platform shares the same R12™ 12-bit ADC architecture, Ultra Phosphor 3.0 acquisition, and standard-included protocol decoding as the UPO2000HD and MSO3000HD families. The differences are bandwidth (150–250 MHz here vs 100–500 MHz on UPO2000HD and 350–1000 MHz on MSO3000HD), capture rate (1,000,000 wfms\/s here vs 1,500,000 wfms\/s on MSO3000HD), and the front-panel form factor. For embedded prototyping and mid-tier power-electronics work, the MSO1000HD platform delivers the same architectural advantages at a lower price point.\u003c\/p\u003e\n\u003ch3\u003eIs the firmware field-upgradable?\u003c\/h3\u003e\n\u003cp\u003eYes. Firmware updates are free over the product's lifetime and install via USB drive or LAN transfer. Optional license unlocks (such as the LA16 logic-analyzer license, when ordered with the UT-M26 pod) have no expiration.\u003c\/p\u003e\n\u003ch4\u003eVideos\u003c\/h4\u003e\n\u003cp\u003e\u003ciframe width=\"560\" height=\"315\" src=\"https:\/\/www.youtube.com\/embed\/aambUMpF_ZI?si=PRi7LQwe62SyC7bX\" title=\"YouTube video player\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Uni-Trend US","offers":[{"title":"181100300118X","offer_id":54423242146016,"sku":"181100300118X","price":691.0,"currency_code":"USD","in_stock":true},{"title":"181100300135X","offer_id":54423242178784,"sku":"181100300135X","price":691.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/MSO1154HD-S_2_sq.jpg?v=1782858082"},{"product_id":"upo7204l-lab-grade-2-ghz-4ch-eight-in-one-rack-mount-oscilloscope","title":"UPO7204L Lab-Grade 2 GHz 4Ch Eight-in-One Rack-Mount Oscilloscope","description":"\u003ch1\u003eThe UNI-T UPO7204L 2 GHz Rack-Mount Digital Storage Oscilloscope is a high-performance 1U, four-channel oscilloscope engineered for automated test equipment (ATE), semiconductor validation, aerospace and automotive testing and high-speed digital design.\u003c\/h1\u003e\n\u003cp\u003eDelivering up to 2 GHz analog bandwidth, 10 GSa\/s real-time sampling, and 1 Gpts of acquisition memory, the UPO7204L combines laboratory-grade performance with the space efficiency required for modern rack-based test systems. Its compact half-width 1U chassis allows two instruments to share a single rack space while supporting HDMI display output, browser-based WebServer control, and comprehensive SCPI automation.\u003c\/p\u003e\n\u003cp\u003eDesigned for advanced engineering environments, the UPO7204L integrates multiple measurement tools into a single platform, including an oscilloscope, enhanced FFT spectrum analyzer, digital voltmeter, hardware frequency counter, serial protocol analyzer, and optional arbitrary waveform generation, power analysis, and jitter analysis with eye diagrams. Support for synchronized operation across as many as 128 instruments and 512 channels makes the UPO7204L an ideal solution for scalable automated test systems, high-speed serial interface validation, communications, semiconductor characterization, and research laboratories.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e2 GHz analog bandwidth with four input channels\u003c\/li\u003e\n\u003cli\u003eUp to 10 GSa\/s real-time sampling\u003c\/li\u003e\n\u003cli\u003eUp to 1 Gpts acquisition memory\u003c\/li\u003e\n\u003cli\u003eUltraAcq® acquisition with up to 600,000 waveforms per second and 2,000,000 waveforms per second in Sequence Mode\u003c\/li\u003e\n\u003cli\u003eCompact half-width 1U rack-mount chassis\u003c\/li\u003e\n\u003cli\u003eHDMI display output with browser-based WebServer remote operation\u003c\/li\u003e\n\u003cli\u003eIntegrated spectrum analyzer, digital voltmeter, and hardware frequency counter\u003c\/li\u003e\n\u003cli\u003eStandard serial protocol decoding with optional protocol expansion\u003c\/li\u003e\n\u003cli\u003eOptional 60 MHz arbitrary waveform generator\u003c\/li\u003e\n\u003cli\u003eOptional power analysis, jitter analysis, and eye diagram software\u003c\/li\u003e\n\u003cli\u003eWindows 10 IoT platform with embedded MATLAB and Python support\u003c\/li\u003e\n\u003cli\u003eSynchronization for up to 128 instruments and 512 channels\u003c\/li\u003e\n\u003cli\u003eDual Gigabit LAN, USB, HDMI, 10 MHz reference, and SCPI automation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eDesigned for High-Density Rack Integration\u003c\/h2\u003e\n\u003cp\u003eThe UPO7204L is purpose-built for automated test systems where rack space, scalability, and remote accessibility are critical. Its compact half-width 1U design allows two oscilloscopes to occupy a single rack location, maximizing channel density while minimizing equipment footprint. HDMI video output, integrated WebServer control, and comprehensive SCPI programming enable engineers to configure, monitor, and automate measurements remotely from virtually any network-connected workstation.\u003c\/p\u003e\n\u003ch2\u003eHigh-Speed Acquisition Performance\u003c\/h2\u003e\n\u003cp\u003eCombining 2 GHz analog bandwidth with up to 10 GSa\/s real-time sampling and acquisition memory of up to 1 Gpts, the UPO7204L provides exceptional performance for fast digital interfaces, wide-bandgap power electronics, RF measurements, and signal integrity analysis. UNI-T's UltraAcq® acquisition engine captures up to 600,000 waveforms per second during continuous acquisition and up to 2,000,000 waveforms per second in Sequence Mode, allowing engineers to identify intermittent faults, timing violations, and transient events with confidence.\u003c\/p\u003e\n\u003ch2\u003eIntegrated Analysis Platform\u003c\/h2\u003e\n\u003cp\u003eMore than a conventional oscilloscope, the UPO7204L combines several laboratory instruments into a single rack-mounted platform. Standard capabilities include an enhanced FFT spectrum analyzer, digital voltmeter, hardware frequency counter, and serial protocol decoding for UART, RS-232\/422\/485, I²C, SPI, CAN, and LIN. Optional software packages expand the system with a 60 MHz arbitrary waveform generator, advanced power analysis, jitter and eye diagram measurements, and additional protocol support for automotive, audio, and aerospace applications.\u003c\/p\u003e\n\u003ch2\u003eScalable Multi-Instrument Synchronization\u003c\/h2\u003e\n\u003cp\u003eThe UPO7204L supports synchronized acquisition across up to 128 oscilloscopes, providing as many as 512 time-correlated analog channels for large-scale automated test systems. Low inter-instrument trigger jitter ensures accurate timing across multiple instruments, making the platform well suited for semiconductor characterization, aerospace validation, communications testing, battery development, and other high-channel-count applications beyond the capabilities of conventional benchtop oscilloscopes.\u003c\/p\u003e\n\u003ch2\u003eAutomation and Remote Operation\u003c\/h2\u003e\n\u003cp\u003ePowered by Windows 10 IoT with embedded MATLAB and Python support, the UPO7204L integrates easily into automated measurement systems. Dual Gigabit Ethernet ports, USB connectivity, browser-based WebServer access, and comprehensive SCPI command support simplify instrument control, waveform acquisition, reporting, and custom automation. Engineers can remotely configure the instrument, export waveform data, capture screenshots, and execute automated test routines without requiring dedicated software on the host computer.\u003c\/p\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cp\u003eThe UNI-T UPO7204L is ideal for automated test equipment (ATE), semiconductor characterization, aerospace and defense electronics, automotive validation, communications engineering, high-speed digital design, signal integrity analysis, university research laboratories, and production test environments. Its combination of 2 GHz bandwidth, high-speed acquisition, integrated analysis tools, rack-mounted efficiency, and scalable synchronization provides an advanced measurement platform for demanding engineering applications.\u003c\/p\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUPO7204L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAnalog Bandwidth (-3dB)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 GHz @ 50 Ω (single-channel mode); 500 MHz @ 1 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCalculated Rise Time (typical)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e175 ps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAnalog Channels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 (plus 1 EXT trigger channel)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Real-Time Sample Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 GSa\/s (single-ch); 5 GSa\/s (dual: C1+C2 or C3+C4); 2.5 GSa\/s (full four-ch)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Memory Depth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 Gpts single-ch; 500 Mpts dual-ch; 250 Mpts full four-ch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVertical Resolution (Native)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8-bit ADC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHigh Resolution Mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 12 effective bits via single-acquisition averaging (acquisition menu)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnhanced Resolution (ERes)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to +3 bits via FPGA-resident FIR filter (acquisition menu, not Math); 0.5–3 bit enhancement, per-channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandard Capture Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≥600,000 wfms\/s (UltraAcq®)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSequence Mode Capture Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2,000,000 wfms\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrigger Types\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEdge, pulse width, slope, video, pattern, timeout, runt, setup \u0026amp; hold, delay, duration, Nth edge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtocol Decoding (Standard)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRS-232\/422\/485\/UART, I²C, SPI, CAN, LIN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtocol Decoding (Optional)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCAN-FD, FlexRay, SENT, AudioBus (I²S\/LJ\/RJ\/TDM), MIL-STD-1553\/ARINC 429\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOptional Analysis Packages\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUPO7000L-AWG (60 MHz, 1-ch, 16-bit, 625 MSa\/s); UPO7000L-JITTER (TIE\/TJ\/RJ\/DJ\/PJ\/DDJ\/DCD + eye diagram); UPO7000L-PWR (6 measurements: PQ, harmonic, switching loss, ripple, loop, SOA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMulti-Machine Synchronization\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 128 instruments \/ 512 channels; 200 ps RMS inter-instrument trigger jitter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAutomated Measurements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e48 (10 displayed simultaneously; 35 in Quick Meas)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eExternal via HDMI (1U headless)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eComputing Platform\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIntel Core i5-7200U 2.5 GHz, 8 GB RAM, 128 GB SSD, Windows 10 IoT Ent LTSC 64-bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterfaces\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSB Host (4: USB 2.0 ×2, USB 3.0 ×2) \/ USB Device \/ LAN (10\/100\/1000) ×2 \/ HDMI \/ AUX \/ EXT \/ 10 MHz Ref In\/Out \/ Audio\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRemote Control\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSCPI (USBTMC); built-in WebServer (PC and smartphone)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eForm Factor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1U half-width rack-mount; 214 mm × 43 mm × 500 mm; \u0026lt;3.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCE, cETLus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch4\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4\u003eDownloads\u003c\/h4\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/UPO7000L_-_Data_Sheet_-_V2.1.pdf\" title=\"UPO7000 Series Datasheet\" target=\"_blank\"\u003e\u003cimg alt=\"PDF\" style=\"float: left;\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/pdf-icon-63x63_480x480.png\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/850009-i.pdf\" target=\"_blank\"\u003e\u003cbr\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/UPO7000L_-_Data_Sheet_-_V2.1.pdf\"\u003eUNI-T UPO7000 Series Datasheet\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4\u003eOptions \u0026amp; Accessories\u003c\/h4\u003e\n\u003ch3\u003eIncluded\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUT-P07A passive high-impedance probes (1X DC–8 MHz; 10X DC–500 MHz) × 4\u003c\/li\u003e\n\u003cli\u003eUT-D30 USB 3.0 data cable\u003c\/li\u003e\n\u003cli\u003eUT-L45 BNC-to-BNC straight-through cable × 2\u003c\/li\u003e\n\u003cli\u003eNational-standard power cable\u003c\/li\u003e\n\u003cli\u003eCalibration certificate\u003c\/li\u003e\n\u003cli\u003eQuick start guide\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAvailable Options\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUPO7000L-AWG — Single-channel 60 MHz function\/arbitrary waveform generator\u003c\/li\u003e\n\u003cli\u003eUPO7000L-JITTER — Advanced jitter analysis and eye diagram\u003c\/li\u003e\n\u003cli\u003eUPO7000L-PWR — Advanced power analysis (6 measurement types)\u003c\/li\u003e\n\u003cli\u003eUPO7000L-BND — Upgrade suite (JITTER, PWR, CANFD, FLEX, SENT, AUDIO, AERO)\u003c\/li\u003e\n\u003cli\u003eIndividual protocol licenses: CAN-FD, FlexRay, SENT, AUDIO, AERO (MIL-STD-1553\/ARINC 429)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eRecommended Accessories\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUT-PA2000 — 2 GHz active single-ended probe (10X, ≤1 pF input capacitance, ±7 V dynamic range) — engineered for the 7000-series\u003c\/li\u003e\n\u003cli\u003eUT-P20 — 100 MHz, 100:1 high-voltage passive probe (1.5 kVrms)\u003c\/li\u003e\n\u003cli\u003eUT-P21 — 50 MHz, 1000:1 high-voltage passive probe (DC 15 kVrms)\u003c\/li\u003e\n\u003cli\u003eUT-P30 \/ UT-P31 \/ UT-P32 \/ UT-P33 — High-voltage differential probes (100\/100\/50\/120 MHz)\u003c\/li\u003e\n\u003cli\u003eUT-P40 \/ UT-P41 \/ UT-P42 \/ UT-P43 \/ UT-P44 — Current probes (100 kHz to 50 MHz)\u003c\/li\u003e\n\u003cli\u003eUT-ISOT — Isolation transformer\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSoftware Options\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUPO7000L-AERO — MIL-STD-1553 and ARINC 429 Serial Bus Trigger and Analysis Option\u003c\/li\u003e\n\u003cli\u003eUPO7000L-AUDIO — Audio Serial Bus Trigger and Analysis Option (I2S, LJ, RJ, TDM)\u003c\/li\u003e\n\u003cli\u003eUPO7000L-AWG — Single-Channel 60MHz Arbitrary Waveform Generator Option\u003c\/li\u003e\n\u003cli\u003eUPO7000L-BND — Complete Options Bundle (AERO, AUDIO, CANFD, FLEX, JITTER, PWR, SENT)\u003c\/li\u003e\n\u003cli\u003eUPO7000L-BW-10T20 — UPO7104L Bandwidth Upgrade from 1GHz to 2GHz Option\u003c\/li\u003e\n\u003cli\u003eUPO7000L-CANFD — CAN-FD Serial Bus Trigger and Analysis Option\u003c\/li\u003e\n\u003cli\u003eUPO7000L-FLEX — FlexRay Serial Bus Trigger and Analysis Option\u003c\/li\u003e\n\u003cli\u003eUPO7000L-JITTER — Jitter Analysis and Eye Diagram Option\u003c\/li\u003e\n\u003cli\u003eUPO7000L-PWR — Advanced Power Analysis Option\u003c\/li\u003e\n\u003cli\u003eUPO7000L-SENT — Automotive SENT Sensor Bus Trigger and Analysis Option\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFamily Members\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUPO7104L (1 GHz, 4-channel)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFAQ's\u003c\/h4\u003e\n\u003ch3\u003eWhy a rack-mount oscilloscope instead of a benchtop instrument?\u003c\/h3\u003e\n\u003cp\u003eRack-mount form factor solves a problem benchtop scopes structurally cannot: it integrates into ATE racks alongside other 1U\/2U test instruments, frees bench surface in shared-lab environments, and supports parallel high-channel-count architectures via multi-machine sync (up to 128 units \/ 512 channels with 200 ps RMS inter-instrument jitter). For benchtop design-validation work where one operator drives one scope on one bench, a benchtop instrument is the right tool. For ATE racks running parallel parametric test on aerospace, automotive, or semiconductor designs, where rack density and channel-count scaling are the buying constraints, the 1U headless UPO7204L is purpose-engineered for that workflow. WebServer remote control over LAN means operator interaction happens from any browser; HDMI external display supports local visual debug when required.\u003c\/p\u003e\n\u003ch3\u003eWhat's the difference between standard capture rate and Sequence mode?\u003c\/h3\u003e\n\u003cp\u003eStandard capture rate (≥600,000 wfms\/s via UltraAcq®) is the UPO7204L’s continuous real-time waveform acquisition rate. Sequence mode (2,000,000 wfms\/s) uses segmented memory to capture multiple trigger-conditioned frames for post-capture replay — for rare-event hunting where the trigger is well-defined.\u003c\/p\u003e\n\u003ch4\u003eVideos\u003c\/h4\u003e\n\u003cp\u003e\u003ciframe width=\"560\" height=\"315\" src=\"https:\/\/www.youtube.com\/embed\/3AAUgv_YJ8M?si=5Y_6JtSJQjDVM8VM\" title=\"YouTube video player\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Uni-Trend US","offers":[{"title":"181100200134X","offer_id":53265476583648,"sku":"181100200134X","price":13999.0,"currency_code":"USD","in_stock":true},{"title":"181100200094X","offer_id":53265476616416,"sku":"181100200094X","price":13999.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/UPO7000L_1_sq.jpg?v=1782858082"},{"product_id":"upo7104l-1-ghz-4ch-eight-in-one-rack-mount-oscilloscope","title":"UPO7104L 1 GHz 4Ch Eight-in-One Rack-Mount Oscilloscope","description":"\u003ch1\u003eThe UNI-T UPO7104L 1 GHz Rack-Mount Digital Storage Oscilloscope is a high-performance 1U, four-channel oscilloscope engineered for automated test equipment (ATE), production test, validation laboratories, and high-density rack installations.\u003c\/h1\u003e\n\u003cp\u003eCombining up to 1 GHz bandwidth, 10 GSa\/s real-time sampling, and 1 Gpts of acquisition memory in a compact half-width 1U chassis, the UPO7104L delivers laboratory-grade performance while maximizing valuable rack space. Designed for remote operation, the instrument supports HDMI video output, browser-based WebServer control, and comprehensive SCPI automation for seamless integration into modern test environments.\u003c\/p\u003e\n\u003cp\u003eMore than a traditional oscilloscope, the UPO7104L integrates multiple analysis tools into a single platform, including a spectrum analyzer, digital voltmeter, hardware frequency counter, serial protocol decoding, and optional arbitrary waveform generation, power analysis, and jitter analysis with eye diagrams. Multi-instrument synchronization supports systems of up to 128 instruments and 512 channels, making the UPO7104L an ideal solution for scalable automated test systems, semiconductor validation, aerospace electronics, communications, and advanced research applications.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e1 GHz bandwidth with four analog input channels\u003c\/li\u003e\n\u003cli\u003eUp to 10 GSa\/s real-time sampling (single channel)\u003c\/li\u003e\n\u003cli\u003e1 Gpts maximum acquisition memory\u003c\/li\u003e\n\u003cli\u003eUltraAcq® acquisition with up to 600,000 waveforms per second and 2,000,000 waveforms per second in Sequence Mode\u003c\/li\u003e\n\u003cli\u003eCompact half-width 1U rack-mount chassis\u003c\/li\u003e\n\u003cli\u003eHDMI display output with browser-based WebServer remote control\u003c\/li\u003e\n\u003cli\u003eIntegrated spectrum analyzer, digital voltmeter, and hardware frequency counter\u003c\/li\u003e\n\u003cli\u003eStandard serial protocol decoding with optional protocol expansion\u003c\/li\u003e\n\u003cli\u003eOptional 60 MHz arbitrary waveform generator\u003c\/li\u003e\n\u003cli\u003eOptional power analysis, jitter analysis, and eye diagram software\u003c\/li\u003e\n\u003cli\u003eWindows 10 IoT platform with embedded MATLAB and Python support\u003c\/li\u003e\n\u003cli\u003eMulti-instrument synchronization for up to 128 instruments and 512 channels\u003c\/li\u003e\n\u003cli\u003eDual Gigabit LAN, USB, HDMI, 10 MHz reference, and SCPI remote control\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOptimized for Rack-Mount Test Systems\u003c\/h3\u003e\n\u003cp\u003eUnlike traditional benchtop oscilloscopes, the UPO7104L is purpose-built for rack integration and automated testing. Its compact half-width 1U design allows two instruments to occupy a single rack space, significantly increasing measurement density while reducing equipment footprint. Browser-based WebServer control, HDMI display output, and full SCPI command support allow engineers to configure, monitor, and automate measurements without direct access to the instrument, making it well suited for production lines, environmental chambers, and centralized test systems.\u003c\/p\u003e\n\u003ch3\u003eHigh-Speed Acquisition Performance\u003c\/h3\u003e\n\u003cp\u003eThe UPO7104L combines a 1 GHz analog bandwidth with up to 10 GSa\/s real-time sampling and acquisition memory of up to 1 Gpts, enabling long-duration captures without sacrificing sample resolution. UNI-T's UltraAcq® acquisition technology captures up to 600,000 waveforms per second during standard operation and up to 2,000,000 waveforms per second in Sequence Mode, helping engineers detect intermittent faults, timing violations, and rare signal anomalies that slower acquisition systems may overlook.\u003c\/p\u003e\n\u003ch3\u003eIntegrated Analysis Tools\u003c\/h3\u003e\n\u003cp\u003eThe UPO7104L consolidates multiple laboratory instruments into a single platform to simplify test setups and reduce equipment costs. Standard functionality includes an enhanced FFT spectrum analyzer, digital voltmeter, hardware frequency counter, and serial protocol decoding for UART, RS-232\/422\/485, I²C, SPI, CAN, and LIN. Optional software packages expand the instrument with a 60 MHz arbitrary waveform generator, advanced power analysis, jitter analysis, eye diagrams, and additional protocol support for automotive, audio, and aerospace applications.\u003c\/p\u003e\n\u003ch3\u003eScalable Multi-Instrument Synchronization\u003c\/h3\u003e\n\u003cp\u003eFor applications requiring synchronized measurements across large channel counts, the UPO7104L supports multi-instrument synchronization of up to 128 oscilloscopes, providing as many as 512 synchronized analog channels with low inter-instrument trigger jitter. This architecture makes the UPO7104L well suited for semiconductor testing, aerospace systems, communications equipment, battery testing, and other high-channel-count validation environments where conventional benchtop oscilloscopes cannot efficiently scale.\u003c\/p\u003e\n\u003ch3\u003eAutomation and Remote Operation\u003c\/h3\u003e\n\u003cp\u003eBuilt on a Windows 10 IoT platform with embedded MATLAB and Python support, the UPO7104L integrates easily into automated test environments. Dual Gigabit LAN ports, USB connectivity, browser-based remote operation, and comprehensive SCPI programming simplify instrument control, waveform acquisition, report generation, and custom analysis. Engineers can remotely manage measurements, capture screenshots, export waveform data, and execute automated test sequences from virtually any network-connected workstation.\u003c\/p\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cp\u003eThe UNI-T UPO7104L is ideal for automated test equipment (ATE), production testing, semiconductor validation, aerospace and defense electronics, communications systems, industrial automation, university research laboratories, and multi-channel engineering test environments. Its combination of rack-mount efficiency, high-speed acquisition, advanced analysis software, and scalable synchronization makes it a powerful solution for organizations requiring reliable, high-performance measurements in space-constrained installations.\u003c\/p\u003e\n\u003cdiv class=\"product-container\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUPO7104L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAnalog Bandwidth (-3dB)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 GHz @ 50 Ω (single-channel mode); 500 MHz @ 1 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCalculated Rise Time (typical)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e350 ps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAnalog Channels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 (plus 1 EXT trigger channel)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Real-Time Sample Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 GSa\/s (single-ch); 5 GSa\/s (dual: C1+C2 or C3+C4); 2.5 GSa\/s (full four-ch)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Memory Depth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 Gpts single-ch; 500 Mpts dual-ch; 250 Mpts full four-ch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVertical Resolution (Native)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8-bit ADC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHigh Resolution Mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 12 effective bits via single-acquisition averaging (acquisition menu)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnhanced Resolution (ERes)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to +3 bits via FPGA-resident FIR filter (acquisition menu, not Math); 0.5–3 bit enhancement, per-channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandard Capture Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≥600,000 wfms\/s (UltraAcq®)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSequence Mode Capture Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2,000,000 wfms\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrigger Types\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEdge, pulse width, slope, video, pattern, timeout, runt, setup \u0026amp; hold, delay, duration, Nth edge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtocol Decoding (Standard)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRS-232\/422\/485\/UART, I²C, SPI, CAN, LIN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtocol Decoding (Optional)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCAN-FD, FlexRay, SENT, AudioBus (I²S\/LJ\/RJ\/TDM), MIL-STD-1553\/ARINC 429\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOptional Analysis Packages\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUPO7000L-AWG (60 MHz, 1-ch, 16-bit, 625 MSa\/s); UPO7000L-JITTER (TIE\/TJ\/RJ\/DJ\/PJ\/DDJ\/DCD + eye diagram); UPO7000L-PWR (6 measurements: PQ, harmonic, switching loss, ripple, loop, SOA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMulti-Machine Synchronization\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 128 instruments \/ 512 channels; 200 ps RMS inter-instrument trigger jitter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAutomated Measurements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e48 (10 displayed simultaneously; 35 in Quick Meas)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eExternal via HDMI (1U headless)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eComputing Platform\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIntel Core i5-7200U 2.5 GHz, 8 GB RAM, 128 GB SSD, Windows 10 IoT Ent LTSC 64-bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterfaces\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSB Host (4: USB 2.0 ×2, USB 3.0 ×2) \/ USB Device \/ LAN (10\/100\/1000) ×2 \/ HDMI \/ AUX \/ EXT \/ 10 MHz Ref In\/Out \/ Audio\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRemote Control\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSCPI (USBTMC); built-in WebServer (PC and smartphone)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eForm Factor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1U half-width rack-mount; 214 mm × 43 mm × 500 mm; \u0026lt;3.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCE, cETLus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eDownloads\u003c\/h4\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cstrong\u003e\u003ca title=\"UPO7000 Series Datasheet\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/UPO7000L_-_Data_Sheet_-_V2.1.pdf\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/pdf-icon-63x63_480x480.png\" style=\"float: left;\" alt=\"PDF\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/850009-i.pdf\" target=\"_blank\"\u003e\u003cbr\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/UPO7000L_-_Data_Sheet_-_V2.1.pdf\"\u003eUNI-T UPO7000 Series Datasheet\u003c\/a\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch4\u003eFAQ's\u003c\/h4\u003e\n\u003ch3\u003eShould I size up to the UPO7204L instead?\u003c\/h3\u003e\n\u003cp\u003eIf your fastest signal edges are below ~700 MHz and you don’t need the additional 1 GHz of single-channel-mode analog bandwidth, the UPO7104L has the same 10 GSa\/s peak sample rate, the same 1 Gpts memory at single-channel mode, the same UltraAcq® acquisition engine, the same multi-machine sync architecture, and the same 11-protocol decode set as the UPO7204L — the 1 GHz vs 2 GHz analog bandwidth ceiling is the only meaningful difference on the spec sheet. The UPO7204L is worth the step-up when you’re working at the rise-time edge of 2 GHz analog signal-integrity, characterizing high-speed serial-link compliance (USB 3.0, PCIe Gen 1\/2 region, MIPI), running jitter analysis on data rates above ~1 Gbps, or running ATE racks where headroom matters for measurement accuracy on customer designs.\u003c\/p\u003e\n\u003ch3\u003eWhat's the difference between standard capture rate and Sequence mode?\u003c\/h3\u003e\n\u003cp\u003eStandard capture rate (≥600,000 wfms\/s via UltraAcq®) is the UPO7104L’s continuous real-time waveform acquisition rate. Sequence mode (2,000,000 wfms\/s) uses segmented memory to capture multiple trigger-conditioned frames for post-capture replay — for rare-event hunting where the trigger is well-defined.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch4\u003eOptions \u0026amp; Accessories\u003c\/h4\u003e\n\u003ch4\u003eOptions \u0026amp; Accessories\u003c\/h4\u003e\n\u003ch3\u003eIncluded\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUT-P07A passive high-impedance probes (1X DC–8 MHz; 10X DC–500 MHz) × 4\u003c\/li\u003e\n\u003cli\u003eUT-D30 USB 3.0 data cable\u003c\/li\u003e\n\u003cli\u003eUT-L45 BNC-to-BNC straight-through cable × 2\u003c\/li\u003e\n\u003cli\u003eNational-standard power cable\u003c\/li\u003e\n\u003cli\u003eCalibration certificate\u003c\/li\u003e\n\u003cli\u003eQuick start guide\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAvailable Options\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUPO7000L-AWG — Single-channel 60 MHz function\/arbitrary waveform generator\u003c\/li\u003e\n\u003cli\u003eUPO7000L-JITTER — Advanced jitter analysis and eye diagram\u003c\/li\u003e\n\u003cli\u003eUPO7000L-PWR — Advanced power analysis (6 measurement types)\u003c\/li\u003e\n\u003cli\u003eUPO7000L-BND — Upgrade suite (JITTER, PWR, CANFD, FLEX, SENT, AUDIO, AERO)\u003c\/li\u003e\n\u003cli\u003eIndividual protocol licenses: CAN-FD, FlexRay, SENT, AUDIO, AERO (MIL-STD-1553\/ARINC 429)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eRecommended Accessories\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUT-PA2000 — 2 GHz active single-ended probe (10X, ≤1 pF input capacitance, ±7 V dynamic range) — engineered for the 7000-series\u003c\/li\u003e\n\u003cli\u003eUT-P20 — 100 MHz, 100:1 high-voltage passive probe (1.5 kVrms)\u003c\/li\u003e\n\u003cli\u003eUT-P21 — 50 MHz, 1000:1 high-voltage passive probe (DC 15 kVrms)\u003c\/li\u003e\n\u003cli\u003eUT-P30 \/ UT-P31 \/ UT-P32 \/ UT-P33 — High-voltage differential probes (100\/100\/50\/120 MHz)\u003c\/li\u003e\n\u003cli\u003eUT-P40 \/ UT-P41 \/ UT-P42 \/ UT-P43 \/ UT-P44 — Current probes (100 kHz to 50 MHz)\u003c\/li\u003e\n\u003cli\u003eUT-ISOT — Isolation transformer\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSoftware Options:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUPO7000L-AERO — MIL-STD-1553 and ARINC 429 Serial Bus Trigger and Analysis Option\u003c\/li\u003e\n\u003cli\u003eUPO7000L-AUDIO — Audio Serial Bus Trigger and Analysis Option (I2S, LJ, RJ, TDM)\u003c\/li\u003e\n\u003cli\u003eUPO7000L-AWG — Single-Channel 60MHz Arbitrary Waveform Generator Option\u003c\/li\u003e\n\u003cli\u003eUPO7000L-BND — Complete Options Bundle (AERO, AUDIO, CANFD, FLEX, JITTER, PWR, SENT)\u003c\/li\u003e\n\u003cli\u003eUPO7000L-BW-10T20 — UPO7104L Bandwidth Upgrade from 1GHz to 2GHz Option\u003c\/li\u003e\n\u003cli\u003eUPO7000L-CANFD — CAN-FD Serial Bus Trigger and Analysis Option\u003c\/li\u003e\n\u003cli\u003eUPO7000L-FLEX — FlexRay Serial Bus Trigger and Analysis Option\u003c\/li\u003e\n\u003cli\u003eUPO7000L-JITTER — Jitter Analysis and Eye Diagram Option\u003c\/li\u003e\n\u003cli\u003eUPO7000L-PWR — Advanced Power Analysis Option\u003c\/li\u003e\n\u003cli\u003eUPO7000L-SENT — Automotive SENT Sensor Bus Trigger and Analysis Option\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFamily Members\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUPO7204L (2 GHz, 4-channel)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eVideos\u003c\/h4\u003e\n\u003cp\u003e\u003ciframe width=\"560\" height=\"315\" src=\"https:\/\/www.youtube.com\/embed\/3AAUgv_YJ8M?si=5Y_6JtSJQjDVM8VM\" title=\"YouTube video player\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Uni-Trend US","offers":[{"title":"Default Title","offer_id":53265476649184,"sku":"181100200141X","price":7999.2,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/UPO7000L_2_sq.jpg?v=1782858082"},{"product_id":"upo1054-50-mhz-4ch-digital-storage-oscilloscope","title":"UPO1054 50 MHz 4Ch Digital Storage Oscilloscope","description":"\u003ch1\u003eThe UNI-T UPO1054 is a 50 MHz, four-channel digital storage oscilloscope with 2 GSa\/s real-time sample rate, 56 Mpts memory depth, and a 500,000 wfms\/s waveform capture rate (Fast Acquire mode).\u003c\/h1\u003e\n\u003cp\u003eUltra Phosphor 2.0 display technology drives 256-level intensity grading on a 7-inch WVGA TFT LCD, making it straightforward to distinguish frequent signal behavior from rare anomalies at a glance.\u003c\/p\u003e\n\u003cp\u003eFour channels, 56 Mpts of memory, an independent DVM module, an enhanced 1 Mpts FFT, and three serial bus protocols decoded as standard — features that typically migrate to mid-tier scopes. The UPO1054 keeps them on the value-tier bench, which is the value proposition for teaching labs running twenty stations and engineering teams sourcing a second scope without sacrificing capability.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e50 MHz bandwidth, 4 channels\u003c\/strong\u003e — 2 GSa\/s real-time sample rate (2 GSa\/s on a single channel; 1 GSa\/s on two; 500 MSa\/s on all four), ≤ 7 ns calculated rise time.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e56 Mpts memory depth\u003c\/strong\u003e — capture full switching cycles and long protocol sequences without trading sample rate for record length.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e500,000 wfms\/s waveform capture rate\u003c\/strong\u003e — Ultra Phosphor 2.0 with 256-level intensity grading, in Fast Acquire mode. Fast enough to surface intermittent events that slower scopes spend hours missing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e1 Mpts enhanced FFT\u003c\/strong\u003e — frequency-domain analysis with frequency setting, demodulation mode, waterfall display, and marker measurement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndependent DVM module\u003c\/strong\u003e — dedicated AC\/DC True RMS digital voltmeter, operating in parallel with scope acquisition.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e7-digit hardware frequency counter\u003c\/strong\u003e — hardware-accelerated counter alongside the scope channels.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e3 serial bus decoders standard\u003c\/strong\u003e — RS-232\/UART, I²C, and SPI trigger and decode included; full-memory hardware decoding turns multi-second decode times into milliseconds.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e36 automated measurements\u003c\/strong\u003e — time, voltage, frequency, and statistical measurements with cursor-area scoping.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMultiple trigger types\u003c\/strong\u003e — edge, pulse width, video, slope, runt, over-amplitude, delay, timeout, duration, setup\/hold, Nth edge, and pattern triggers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeb remote control\u003c\/strong\u003e — browser-based access from any PC or mobile device on the LAN; no driver software, no host application.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCPI + LAN automation\u003c\/strong\u003e — Standard Command for Programmable Instruments over LAN for scripted test sequences.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003e\n\u003cbr\u003eUNI-T UPO1054 Details\u003c\/h2\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003eUltra Phosphor 2.0\u003c\/h3\u003e\n\u003cp\u003eUltra Phosphor 2.0 is UNI-T's intensity-graded display technology. Waveforms paint with 256-level brightness, where signals that recur often appear bright and rare anomalies show as faint streaks against the baseline trace — the kind of detail a flat-color display paints over.\u003c\/p\u003e\n\u003cp\u003eStandard sampling reaches 150,000 wfms\/s; engaging Fast Acquire mode pushes the rate to 500,000 wfms\/s. Combined with hardware-accelerated continuous waveform recording at up to 120,000 frames, the scope catches glitches, runt pulses, and other transient events that 8-bit value-tier oscilloscopes typically don't surface.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003e\n\u003cbr\u003eIndependent DVM Module\u003c\/h3\u003e\n\u003cp\u003eThe UPO1054 includes a built-in 4-bit digital voltmeter that operates in parallel with the scope channels, displaying AC\/DC True RMS values continuously while the oscilloscope captures waveforms. The DVM has its own display readout and a configurable warning when measurements exceed the specified range — a separate instrument's worth of capability without a separate instrument's bench space, useful for steady-state DC monitoring alongside dynamic AC measurement and for double-checking power-supply rails without breaking the trigger setup.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003e1 Mpts Enhanced FFT\u003c\/h3\u003e\n\u003cp\u003eThe 1 Mpts FFT converts time-domain waveforms to the frequency domain at resolution that matches mid-tier oscilloscopes. Frequency setting, demodulation mode, waterfall display, and automatic peak marking are all standard, supporting EMI troubleshooting, switching-supply harmonic characterization, audio-band analysis, and clock-spur identification. Five window functions (Rectangle, Hanning, Blackman, Hamming, FlatTop) cover the common analysis trade-offs between frequency resolution and amplitude accuracy.\u003cbr\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003e\n\u003cbr\u003eStandard Bus Decoding — RS-232\/UART, I²C, SPI\u003c\/h3\u003e\n\u003cp\u003eRS-232\/UART, I²C, and SPI trigger and decode are standard — no protocol licenses, no add-on packages. Decoded bus traffic overlays the waveform with field-level annotation, and the event list view shows decoded packets alongside the time stamps. Hardware decoding running across the full 56 Mpts memory turns what would be a tens-of-seconds software decode into a sub-second operation, making the UPO1000 a usable embedded-debug instrument rather than a strictly time-domain scope.\u003c\/p\u003e\n\u003cp\u003eNo optional protocol licenses are available on the UPO1054: CAN, CAN-FD, LIN, and FlexRay are not supported on this platform. Buyers who need automotive bus decoding should look at the UPO1000HD or MSO\/UPO2000 series, which support those protocols as paid options.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003e7-digit Hardware Frequency Counter\u003c\/h3\u003e\n\u003cp\u003eA 7-digit hardware-accelerated counter runs alongside the scope's standard automated measurements. The counter reads independently from the channel measurement engine, which gives stable, high-resolution frequency readings on stable signals without the jitter that software counters can exhibit on the lower-density end of the rate range. Useful for verifying oscillator frequencies, clock-recovery loops, and PWM duty cycles where a stable frequency number matters more than time-domain detail.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003eMultiple Trigger Types\u003c\/h3\u003e\n\u003cp\u003eBeyond standard edge triggering, the scope offers pulse width, video, slope, runt, over-amplitude, delay, timeout, duration, setup\/hold, Nth edge, and pattern triggers. Runt and over-amplitude triggers isolate signal-integrity violations that an edge-only trigger would never catch; setup\/hold and Nth edge triggers isolate specific cycles in long protocol captures. The full set is standard, with no trigger-package upgrades to license.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003e36 Automated Measurements with Cursor-Area Scoping\u003c\/h3\u003e\n\u003cp\u003eThirty-six automated measurement parameters cover time, voltage, frequency, and statistical categories: rise\/fall time, pulse width, duty cycle, frequency, period, amplitude, RMS, peak-peak, mean, standard deviation, and others. Each measurement supports cursor-area scoping — the measurement runs only within the cursor window rather than across the full record — useful for measuring a specific burst within a long capture without rezooming. Statistics (min, max, mean, std-dev) accumulate over time for characterization of measurement drift.\u003cbr\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003e\n\u003cbr\u003eWeb Remote Control and SCPI Automation\u003c\/h3\u003e\n\u003cp\u003eConnect the UPO1054 to the LAN and access the full instrument from any web browser — PC, Mac, or mobile — with no driver installation, no host application, no setup. Capture screenshots, change settings, transfer waveform data, and run SCPI commands from any device on the network. Useful for shared lab instruments, rack-mounted teaching benches with cable runs across the room, and Python or LabVIEW automation scripts that drive the scope through standard SCPI over LAN.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003eConnectivity (USB, LAN, AUX)\u003c\/h3\u003e\n\u003cp\u003eStandard interfaces include USB-Host (front and rear) for thumb-drive screenshot capture and firmware updates, USB-Device (rear) for SCPI over USB to a PC, Gigabit LAN for SCPI and web remote, and AUX output for triggered signal handoff. RS-232 is not present on this platform; SCPI runs over USB and LAN. The LAN connection supports both DHCP and static IP configuration for fixed-IP rack deployments.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003e\n\u003cbr\u003eApplications\u003c\/h2\u003e\n\u003ch3\u003eTeaching Lab and Trade-School Curriculum (Education)\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMulti-station deployment at value-tier prices: a real 4 channels scope on every bench, with the same Ultra Phosphor 2.0 UI that students will see in industry on the UPO1000HD and MSO1000HD families.\u003c\/li\u003e\n\u003cli\u003e56 Mpts memory and 1 Mpts FFT cover the full spectrum-and-time-domain undergraduate curriculum without the memory-vs-sample-rate trade-offs that entry scopes normally impose.\u003c\/li\u003e\n\u003cli\u003e36 automated measurements with statistics let students focus on circuit behavior rather than measurement methodology, while the cursor-area mode supports manual measurement teaching.\u003c\/li\u003e\n\u003cli\u003eWeb-based remote control mirrors the screen for classroom demonstration without USB capture cables or projector adapters; SCPI over LAN supports Python and LabVIEW lab exercises.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEmbedded Systems Development (R\u0026amp;D)\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThree serial bus decoders standard (RS-232\/UART, I²C, SPI) cover most low-speed embedded debug workflows without protocol-license fees.\u003c\/li\u003e\n\u003cli\u003e56 Mpts memory captures full firmware-boot and protocol sequences in a single trigger, with full-memory hardware decoding for sub-second decode of long captures.\u003c\/li\u003e\n\u003cli\u003eIndependent DVM module reads supply rails alongside scope traces — useful for verifying brownout, monitoring switching ripple, or validating reference-voltage stability during prototype bring-up.\u003c\/li\u003e\n\u003cli\u003eSCPI over LAN runs Python regression scripts on the same instrument that the bench engineer uses interactively — automation without a separate automation-class scope.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectronics Service, Repair, and Maintenance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBench-portable form factor: AC-line bench scope sized for the typical service workshop without the depth or weight of a flagship instrument.\u003c\/li\u003e\n\u003cli\u003eUltra Phosphor 2.0 with 256-level intensity grading reveals signal-integrity violations (runt pulses, glitches) that flat-color displays paint over — the difference between fixing the root cause and replacing the symptom.\u003c\/li\u003e\n\u003cli\u003eHardware frequency counter gives stable rate readings for verifying oscillator and clock-recovery behavior during board-level repair.\u003c\/li\u003e\n\u003cli\u003eAC\/DC True RMS DVM module replaces the bench multimeter for steady-state checks while keeping the scope trigger configuration intact.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSwitching-Mode Power Supply Validation\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBandwidth selection from 50 MHz matches the switching frequency range of most commercial switching-mode designs at 100 kHz to several MHz, with 56 Mpts memory for capturing long startup transients without losing sample rate.\u003c\/li\u003e\n\u003cli\u003e1 Mpts FFT characterizes ripple harmonics and switching-noise spectral content for EMI pre-compliance investigation alongside time-domain switching analysis.\u003c\/li\u003e\n\u003cli\u003eMultiple trigger types (runt, over-amplitude, pulse-width) isolate switching faults, current spikes during startup, and protection-circuit activations.\u003c\/li\u003e\n\u003cli\u003eIndependent DVM module monitors output-rail DC value while scope captures dynamic AC load-step behavior — both halves of the supply characterization on one instrument.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProduction Test and Quality Control\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSCPI over LAN supports rack-mounted production-line deployment with Python or LabVIEW test scripts; the web remote interface gives line operators a familiar browser-based view without driver installation on each test station.\u003c\/li\u003e\n\u003cli\u003e36 automated measurements with statistics support go\/no-go testing of board-level signal-integrity specs; the cursor-area mode isolates specific cycles for measurement without re-zooming the full capture.\u003c\/li\u003e\n\u003cli\u003eContinuous waveform recording into the memory depth supports historical archiving of production-line captures for later analysis when a batch shows yield-tail issues.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEMI Pre-Compliance Investigation\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 Mpts FFT with five window functions, demodulation mode, and waterfall display supports time-correlated EMI investigation against the time-domain switching waveform — useful for tracking down which switching event produces which emission peak.\u003c\/li\u003e\n\u003cli\u003eMarker measurement on the FFT supports quick peak frequency and amplitude readout during emission-hunt work on a prototype board.\u003c\/li\u003e\n\u003cli\u003eCombined with a near-field probe set and a Faraday-cage cardboard tent, the FFT view supports pre-compliance investigation that catches the obvious failures before the expensive compliance-lab booking.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch3\u003eAccessories \u0026amp; Options\u003c\/h3\u003e\n\u003ch3\u003eIncluded with Every Unit\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUPO1054 digital storage oscilloscope\u003c\/li\u003e\n\u003cli\u003ePower cord (national standard)\u003c\/li\u003e\n\u003cli\u003eUSB 2.0 data cable\u003c\/li\u003e\n\u003cli\u003e4 × passive probes — UT-P04 (100 MHz, one per channel)\u003c\/li\u003e\n\u003cli\u003eQuick start guide\u003c\/li\u003e\n\u003cli\u003eFactory calibration certificate\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eRecommended Accessories\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigher-bandwidth passive probes\u003c\/strong\u003e — UT-P07A (500 MHz) for buyers anticipating a step-up scope in the future.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-voltage passive probes\u003c\/strong\u003e — UT-P20 (100:1, 250 MHz), UT-V23 (100:1), UT-P21 (1000:1, DC 10 kV \/ AC 7 kVrms) for line-voltage and HV switching work.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDifferential probes\u003c\/strong\u003e — UT-P30, UT-P31, UT-P32, UT-P33, UT-P35, UT-P36 for floating measurements where ground reference can't be tied to scope chassis.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent probes\u003c\/strong\u003e — UT-P40, UT-P41, UT-P42, UT-P43, UT-P44; UT-P4150 for high-current AC\/DC measurement on switching and motor-drive applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation transformer\u003c\/strong\u003e — UT-ISOT for line-powered DUTs that require galvanic isolation between scope ground and DUT ground.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFamily Members\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eUPO1054\u003c\/strong\u003e — 50 MHz, 4 channels, 2 GSa\/s \u003cem\u003e(this product)\u003c\/em\u003e\n\u003c\/li\u003e\n\u003cli\u003eUPO1104 — 100 MHz, 4 channels, 2 GSa\/s\u003c\/li\u003e\n\u003cli\u003eUPO1204 — 200 MHz, 4 channels, 2 GSa\/s\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eStep Up: UPO1000HD (4-channel, 12-Bit Vertical)\u003c\/h3\u003e\n\u003cp\u003eIf your application needs higher vertical resolution or deeper memory than the UPO1054 provides, the UPO1000HD family offers 12-bit vertical resolution and the same Ultra Phosphor 2.0 display engine in the same cabinet footprint.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUPO1084HD — 80 MHz, 4 channels, 12-bit vertical resolution\u003c\/li\u003e\n\u003cli\u003eUPO1154HD — 150 MHz, 4 channels, 12-bit vertical resolution\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable style=\"width: 100.089%;\" height=\"826\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.6267%;\"\u003e\u003cstrong\u003eBandwidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.4374%;\"\u003e50 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.6267%;\"\u003e\u003cstrong\u003eChannels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.4374%;\"\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.6267%;\"\u003e\u003cstrong\u003eReal-Time Sample Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.4374%;\"\u003e2 GSa\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.6267%;\"\u003e\u003cstrong\u003eSample Rate per Channel Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.4374%;\"\u003e2 GSa\/s on a single channel; 1 GSa\/s on two; 500 MSa\/s on all four\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.6267%;\"\u003e\u003cstrong\u003eCalculated Rise Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.4374%;\"\u003e≤ 7 ns\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.6267%;\"\u003e\u003cstrong\u003eMemory Depth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.4374%;\"\u003e56 Mpts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.6267%;\"\u003e\u003cstrong\u003eVertical Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.4374%;\"\u003e8 bits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.6267%;\"\u003e\u003cstrong\u003eVertical Scale (1 MΩ)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.4374%;\"\u003e500 µV\/div to 20 V\/div\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.6267%;\"\u003e\u003cstrong\u003eMaximum Input Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.4374%;\"\u003e400 V (DC + AC Vpk)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.6267%;\"\u003e\u003cstrong\u003eWaveform Capture Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.4374%;\"\u003e500,000 wfms\/s (Fast Acquire mode); 150,000 wfms\/s normal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.6267%;\"\u003e\u003cstrong\u003eContinuous Frame Recording\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.4374%;\"\u003e120,000 frames\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.6267%;\"\u003e\u003cstrong\u003eFFT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.4374%;\"\u003e1 Mpts enhanced FFT (5 window functions)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.6267%;\"\u003e\u003cstrong\u003eDVM\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.4374%;\"\u003eIndependent module — 4-bit, AC\/DC True RMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.6267%;\"\u003e\u003cstrong\u003eFrequency Counter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.4374%;\"\u003e7-digit hardware\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.6267%;\"\u003e\u003cstrong\u003eAutomated Measurements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.4374%;\"\u003e36 parameters with statistics and cursor-area scoping\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.6267%;\"\u003e\u003cstrong\u003eTrigger Types\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.4374%;\"\u003eEdge, Pulse Width, Video, Slope, Runt, Over-Amplitude, Delay, Timeout, Duration, Setup\/Hold, Nth Edge, Pattern\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.6267%;\"\u003e\u003cstrong\u003eSerial Bus Decoding (Standard)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.4374%;\"\u003eRS-232\/UART, I²C, SPI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.6267%;\"\u003e\u003cstrong\u003eOptional Protocol Decoders\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.4374%;\"\u003eNone available on this platform\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.6267%;\"\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.4374%;\"\u003e7-inch WVGA TFT LCD, 256-level intensity grading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.6267%;\"\u003e\u003cstrong\u003eInterface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.4374%;\"\u003eUSB-Host (front + rear), USB-Device (rear), LAN (1 GbE), AUX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.6267%;\"\u003e\u003cstrong\u003eRemote Control\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.4374%;\"\u003eWeb browser (no driver), SCPI over LAN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.6267%;\"\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.4374%;\"\u003eCE | cETLus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.6267%;\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.4374%;\"\u003e0°C to 40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.6267%;\"\u003e\u003cstrong\u003eLine Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.4374%;\"\u003e100–240 VAC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.6267%;\"\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.4374%;\"\u003e75 VA maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.6267%;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.4374%;\"\u003e2.45 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.6267%;\"\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.4374%;\"\u003e306 × 138 × 107 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003e\n\u003cbr\u003e\u003cmeta charset=\"utf-8\"\u003e\n\u003c\/h4\u003e\n\u003ch4\u003eDownloads\u003c\/h4\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cbr\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/UPO1054_-_Datasheet.pdf\" title=\"UPO1000 Series Datasheet\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg alt=\"PDF\" style=\"float: left;\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/pdf-icon-63x63_480x480.png\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/850009-i.pdf\" target=\"_blank\"\u003e\u003cbr\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/UPO1054_-_Datasheet.pdf\" title=\"UNI-T UPO1000 Series Datasheet\" rel=\"noopener\" target=\"_blank\"\u003eUNI-T UPO1000 Series Datasheet\u003c\/a\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cbr\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/UPO1000_-_User_Manual_-_V1.0.pdf?v=1782927452\" title=\"UNI-T UPO1000 Series Users Manual\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg alt=\"PDF\" style=\"float: left;\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/pdf-icon-63x63_480x480.png\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/850009-i.pdf\" target=\"_blank\"\u003e\u003cbr\u003e\u003c\/a\u003e\u003ca rel=\"noopener\" title=\"UN I-T UPO1000 Series Users Manual\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/UPO1000_-_User_Manual_-_V1.0.pdf\" target=\"_blank\"\u003eUNI-T UPO1000 Series Users Manual\u003c\/a\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eFAQ's\u003c\/h4\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003ch3 class=\"product-faq-question\"\u003e\n\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003eWhich serial bus protocols are decoded as standard, and which require a license?\u003c\/h3\u003e\n\u003cp\u003eThe UPO1054 decodes \u003cstrong\u003eRS-232\/UART, I²C, and SPI\u003c\/strong\u003e as standard — trigger and decode functions for all three are included with the scope, with no license fees and no protocol-option purchase required. \u003cstrong\u003eNo optional protocol decoders are available on this platform.\u003c\/strong\u003e CAN, CAN-FD, LIN, and FlexRay are not supported on the UPO1000 platform. If your application requires automotive bus decoding, the UPO1000HD or MSO\/UPO2000 series support those protocols as paid options.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003ch3 class=\"product-faq-question\"\u003e\n\u003cbr\u003eWhat is Fast Acquire mode, and when should I use it?\u003c\/h3\u003e\n\u003cp\u003eFast Acquire is a UPO1000-series acquisition mode that boosts waveform capture rate from 150,000 wfms\/s (standard) to \u003cstrong\u003e500,000 wfms\/s\u003c\/strong\u003e. The trade-off is that some screen-update detail is sacrificed for raw capture throughput. Use Fast Acquire when hunting intermittent signal-integrity events (glitches, runt pulses, rare protocol violations) that depend on capturing many waveforms quickly. Use standard mode for everyday time-domain measurement work where the display refresh rate matters more than raw capture density.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003ch3 class=\"product-faq-question\"\u003e\n\u003cbr\u003eDoes the DVM module share input channels with the scope, or is it truly independent?\u003c\/h3\u003e\n\u003cp\u003eThe DVM is \u003cstrong\u003etruly independent\u003c\/strong\u003e: it has its own 4-bit measurement input and operates in parallel with the four (or two) scope channels. You can run a continuous AC\/DC True RMS reading on a supply rail while the scope captures dynamic switching behavior on another channel, without any time-sharing between the two functions. The DVM readout appears on a dedicated portion of the screen and persists across scope-channel configuration changes.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003ch3 class=\"product-faq-question\"\u003e\n\u003cbr\u003eWhat does the web remote control look like in practice, and how does SCPI automation work?\u003c\/h3\u003e\n\u003cp\u003eConnect the UPO1054 to your LAN, point any browser at the scope's IP, and you get a full-screen replica of the front panel that you can drive from your desk or a mobile device — no driver installation, no host application. Useful for shared lab instruments and projection during teaching demos. For automation, the scope responds to \u003cstrong\u003eSCPI commands over LAN\u003c\/strong\u003e (Standard Commands for Programmable Instruments), which means Python (pyvisa), MATLAB Instrument Control Toolbox, LabVIEW, and any other VISA-aware tool can drive the scope through scripts. SCPI also runs over USB-Device for PC-tethered automation when LAN isn't available.\u003c\/p\u003e\n\u003ch4\u003eVideos\u003c\/h4\u003e\n\u003ciframe width=\"280\" height=\"158\" src=\"https:\/\/www.youtube.com\/embed\/PVhwBHhRIrs?si=nekbHMJD1ZsOEs5y\" title=\"YouTube video player\"\u003e\u003c\/iframe\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/div\u003e","brand":"Uni-Trend US","offers":[{"title":"Default Title","offer_id":53265476714720,"sku":"181100200071X","price":311.2,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/UPO1054_1_sq.jpg?v=1782858083"},{"product_id":"mso5104hd-1-ghz-4ch-12-bit-mixed-signal-oscilloscope","title":"MSO5104HD 1 GHz 4Ch 12-Bit Mixed Signal Oscilloscope","description":"\u003ch1\u003eThe UNI-T MSO5104HD 1 GHz 4-Channel Mixed Signal Oscilloscope combines high-speed performance, native 12-bit resolution, and advanced analysis capabilities in a versatile platform for research, design and manufacturing.\u003c\/h1\u003e\n\u003cp\u003e\u003cstrong\u003eWith a 1 GHz bandwidth, up to 5 GSa\/s real-time sample rate, and 500 Mpts standard memory depth, the MSO5104HD delivers the speed and accuracy needed to analyze complex analog and digital signals.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhether you're debugging embedded systems, validating power electronics, or troubleshooting high-speed communications, this oscilloscope provides the tools engineers need to work more efficiently.\u003c\/p\u003e\n\u003cp\u003eBuilt on UNI-T's R12™ native 12-bit ADC architecture, the MSO5104HD delivers significantly higher waveform fidelity than conventional 8-bit oscilloscopes without sacrificing bandwidth or sample rate. Integrated analysis tools, a built-in spectrum analyzer, optional mixed-signal capabilities, and comprehensive protocol decoding allow multiple test functions to be performed from a single instrument, reducing bench space while improving productivity.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e1 GHz analog bandwidth with four input channels\u003c\/li\u003e\n\u003cli\u003eUp to 5 GSa\/s real-time sampling\u003c\/li\u003e\n\u003cli\u003eNative 12-bit vertical resolution with up to 16-bit Enhanced Resolution (ERES)\u003c\/li\u003e\n\u003cli\u003e500 Mpts standard acquisition memory\u003c\/li\u003e\n\u003cli\u003eUltra Phosphor 3.0 acquisition with up to 800,000 wfms\/s standard capture rate\u003c\/li\u003e\n\u003cli\u003eUp to 1.5 million waveforms per second in Sequential Mode\u003c\/li\u003e\n\u003cli\u003eBuilt-in 2.5 GHz spectrum analyzer\u003c\/li\u003e\n\u003cli\u003eStandard serial protocol decoding for UART, RS-232\/422\/485, I²C, SPI, CAN, and LIN\u003c\/li\u003e\n\u003cli\u003eOptional 16-channel logic analyzer using the UT-M15 logic probe pod\u003c\/li\u003e\n\u003cli\u003eOptional 50 MHz dual-channel arbitrary waveform generator and Bode plot analysis\u003c\/li\u003e\n\u003cli\u003eOptional advanced power analysis software\u003c\/li\u003e\n\u003cli\u003e10.1-inch HD capacitive multi-touch display\u003c\/li\u003e\n\u003cli\u003eLAN, USB, WebServer, and SCPI remote control support\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eNative 12-Bit Measurement Performance\u003c\/h3\u003e\n\u003cp\u003eThe MSO5104HD utilizes UNI-T's R12™ native 12-bit analog-to-digital converter to deliver higher vertical resolution and lower noise than traditional 8-bit oscilloscopes. The increased measurement precision improves visibility of small signal details, switching ripple, sensor outputs, and fast digital transitions while maintaining the oscilloscope's full 1 GHz bandwidth and maximum sample rate.\u003c\/p\u003e\n\u003ch3\u003eFast Acquisition with Deep Memory\u003c\/h3\u003e\n\u003cp\u003eUltra Phosphor 3.0 acquisition technology captures up to 800,000 waveforms per second during standard operation and up to 1.5 million waveforms per second in Sequential Mode. Combined with 500 Mpts of acquisition memory, engineers can capture long-duration events, isolate intermittent faults, and review waveform history without sacrificing sample resolution.\u003c\/p\u003e\n\u003ch3\u003eIntegrated Test and Measurement Platform\u003c\/h3\u003e\n\u003cp\u003eMore than a conventional oscilloscope, the MSO5104HD combines multiple laboratory instruments into a single platform. In addition to oscilloscope functionality, it includes a built-in spectrum analyzer and supports optional logic analysis, arbitrary waveform generation, Bode plot analysis, power analysis, and serial protocol decoding. This integrated approach reduces equipment costs while simplifying bench setup and testing.\u003c\/p\u003e\n\u003ch3\u003eMixed Signal and Serial Bus Analysis\u003c\/h3\u003e\n\u003cp\u003eWhen paired with the optional UT-M15 logic probe, the MSO5104HD provides 16 synchronized digital channels for mixed-signal debugging. Standard protocol decoding supports UART, RS-232\/422\/485, I²C, SPI, CAN, and LIN, while optional software licenses expand support for CAN-FD, CAN-XL, FlexRay, SENT, ARINC 429, MIL-STD-1553B, Manchester, 1-Wire, I3C, and additional industry-standard interfaces.\u003c\/p\u003e\n\u003ch3\u003eSpectrum and Power Analysis\u003c\/h3\u003e\n\u003cp\u003eThe integrated 2.5 GHz spectrum analyzer enables frequency-domain analysis without requiring a separate instrument. Optional application software further extends the oscilloscope's capabilities with Bode plot measurements and advanced power analysis, including switching loss, harmonic analysis, ripple, slew rate, SOA, RDS(on), and modulation measurements for power electronics development and validation.\u003c\/p\u003e\n\u003ch3\u003eDesigned for Modern Engineering Applications\u003c\/h3\u003e\n\u003cp\u003eThe MSO5104HD is well suited for embedded systems development, mixed-signal debugging, power electronics, automotive electronics, industrial automation, communications, manufacturing test, university laboratories, and general research and development. Its combination of high bandwidth, native 12-bit acquisition, integrated analysis tools, and flexible expansion options provides engineers with a powerful, scalable measurement platform.\u003c\/p\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable height=\"1110\" style=\"width: 95.2805%;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.5184%;\"\u003e\u003cstrong\u003eAnalog Bandwidth (50 Ω, −3 dB)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.1233%;\"\u003e1 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.5184%;\"\u003e\u003cstrong\u003eAnalog Bandwidth (1 MΩ, −3 dB)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.1233%;\"\u003e500 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.5184%;\"\u003e\u003cstrong\u003eChannels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.1233%;\"\u003e4 Analog + 16 Digital (with optional UT-M15 probe pod)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.5184%;\"\u003e\u003cstrong\u003eReal-Time Sample Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.1233%;\"\u003e5 GSa\/s (interleave mode) \/ 2.5 GSa\/s (non-interleave mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.5184%;\"\u003e\u003cstrong\u003eDigital Channel Sample Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.1233%;\"\u003e1.25 GSa\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.5184%;\"\u003e\u003cstrong\u003eVertical Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.1233%;\"\u003e12-bit native (up to 16-bit with ERES)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.5184%;\"\u003e\u003cstrong\u003eMemory Depth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.1233%;\"\u003e500 Mpts maximum per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.5184%;\"\u003e\u003cstrong\u003eCapture Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.1233%;\"\u003e800,000 wfms\/s standard; 1,500,000 wfms\/s in Sequential Mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.5184%;\"\u003e\u003cstrong\u003eCalculated Rise Time (10–90%, Typ.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.1233%;\"\u003e≤0.35 ns\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.5184%;\"\u003e\u003cstrong\u003eBackground Noise (full BW, Typ.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.1233%;\"\u003e75 µVrms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.5184%;\"\u003e\u003cstrong\u003eDisplay Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.1233%;\"\u003e10.1 inches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.5184%;\"\u003e\u003cstrong\u003eDisplay Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.1233%;\"\u003e1280 × 800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.5184%;\"\u003e\u003cstrong\u003eTouch Screen\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.1233%;\"\u003eCapacitive multi-touch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.5184%;\"\u003e\u003cstrong\u003eSequential Sampling\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.1233%;\"\u003eMaximum 400,000 frames; minimum two trigger intervals \u0026lt; 700 ns\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.5184%;\"\u003e\u003cstrong\u003eHardware Real-Time Waveform Recording\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.1233%;\"\u003e400,000 frames\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.5184%;\"\u003e\u003cstrong\u003eTrigger Modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.1233%;\"\u003e12 types: edge, pulse width, video, ramp, runt, over-amplitude, delay, timeout, duration, setup \u0026amp; hold, Nth edge, code pattern; Zone trigger\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.5184%;\"\u003e\u003cstrong\u003eProtocol Triggering and Decoding\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.1233%;\"\u003e15 protocols total. \u003cstrong\u003eStandard:\u003c\/strong\u003e RS-232\/422\/485\/UART, I²C, SPI, CAN, LIN. \u003cstrong\u003eOptional:\u003c\/strong\u003e CAN-FD, CAN-XL, FlexRay, SENT, Audio, MIL-STD-1553B, ARINC 429, Manchester, 1-Wire, I3C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.5184%;\"\u003e\u003cstrong\u003eSpectrum Analyzer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.1233%;\"\u003e0–2.5 GHz, enhanced FFT up to 4 Mpts, 4-channel parallel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.5184%;\"\u003e\u003cstrong\u003eBuilt-in AWG (Optional)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.1233%;\"\u003e50 MHz equivalent, dual-channel, 312.5 MSa\/s, 16-bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.5184%;\"\u003e\u003cstrong\u003eBode Plot Analyzer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.1233%;\"\u003eOptional — frequency response, loop stability, filter, amplifier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.5184%;\"\u003e\u003cstrong\u003ePower Analyzer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.1233%;\"\u003eOptional — switching loss, harmonics, ripple, slew rate, R\u003csub\u003eDS(on)\u003c\/sub\u003e, SOA, modulation, transient response, power efficiency\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.5184%;\"\u003e\u003cstrong\u003eAutomated Measurements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.1233%;\"\u003e56 types; up to 27 simultaneous; histogram and trend display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.5184%;\"\u003e\u003cstrong\u003eMaximum Input Voltage (1 MΩ)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.1233%;\"\u003e400 V (DC + AC\u003csub\u003eVpk\u003c\/sub\u003e); 135 V\u003csub\u003eRMS\u003c\/sub\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.5184%;\"\u003e\u003cstrong\u003eMaximum Input Voltage (50 Ω)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.1233%;\"\u003e5 V\u003csub\u003eRMS\u003c\/sub\u003e max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.5184%;\"\u003e\u003cstrong\u003eConnectivity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.1233%;\"\u003eUSB Host\/Device, LAN, EXT Trig, AUX Out (Trig Out \/ Pass-Fail \/ DVM), Gen Out, HDMI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.5184%;\"\u003e\u003cstrong\u003eRemote Control\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.1233%;\"\u003eSCPI over LAN\/USB; built-in WebServer (browser, PC + mobile); UNI-T Instrument Manager\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.5184%;\"\u003e\u003cstrong\u003eCompliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.1233%;\"\u003eRoHS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003e\n\u003cbr\u003eDownloads\u003c\/h4\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cstrong\u003e\u003ca title=\"UPO1000 Series Datasheet\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/MSO5000HD_Series_-_Data_Sheet.pdf?v=1782928867\" target=\"_blank\"\u003e\u003cimg alt=\"PDF\" style=\"float: left;\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/pdf-icon-63x63_480x480.png\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/850009-i.pdf\" target=\"_blank\"\u003e\u003cbr\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/MSO5000HD_Series_-_Data_Sheet.pdf?v=1782928867\" title=\"UNI-T UPO1000 Series Datasheet\" rel=\"noopener\" target=\"_blank\"\u003eUNI-T MSO5000HD Series Datasheet\u003c\/a\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cbr\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/MSO5000HD_Series_User_Manual.pdf?v=1782929043\" title=\"UNI-T UPO1000 Series Users Manual\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg alt=\"PDF\" style=\"float: left;\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/pdf-icon-63x63_480x480.png\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/850009-i.pdf\" target=\"_blank\"\u003e\u003cbr\u003e\u003c\/a\u003e\u003ca rel=\"noopener\" title=\"UN I-T UPO1000 Series Users Manual\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/MSO5000HD_Series_User_Manual.pdf?v=1782929043\" target=\"_blank\"\u003eUNI-T MSO5000HS Series Users Manual\u003c\/a\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4\u003eOptions \u0026amp; Accessories\u003c\/h4\u003e\n\u003ch3\u003eIncluded in box:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePower cord\u003c\/li\u003e\n\u003cli\u003eUSB3.0 printing cable\u003c\/li\u003e\n\u003cli\u003eEnglish download guide\u003c\/li\u003e\n\u003cli\u003emulti-language safety manual\u003c\/li\u003e\n\u003cli\u003ecalibration report (COC)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSoftware options:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMSO5000HD-1WIRE — 1-Wire Serial Bus Trigger and Analysis Option\u003c\/li\u003e\n\u003cli\u003eMSO5000HD-ARINC429 — Aerospace ARINC429 Serial Bus Trigger and Analysis\u003c\/li\u003e\n\u003cli\u003eMSO5000HD-AUDIO — Audio Serial Bus Trigger and Analysis\u003c\/li\u003e\n\u003cli\u003eMSO5000HD-AUTO — Automotive Serial Bus Trigger and Analysis Option\u003c\/li\u003e\n\u003cli\u003eMSO5000HD-AWG — 50 MHz 2Ch Arbitrary Waveform Generator with Bode Plot\u003c\/li\u003e\n\u003cli\u003eMSO5000HD-BND — Complete Serial Analysis Bundle\u003c\/li\u003e\n\u003cli\u003eMSO5000HD-CANFD — Automotive CAN-FD Serial Bus Trigger and Analysis\u003c\/li\u003e\n\u003cli\u003eMSO5000HD-CANXL — Automotive CAN-XL Serial Bus Trigger and Analysis\u003c\/li\u003e\n\u003cli\u003eMSO5000HD-FLEX — Automotive FlexRay Serial Bus Trigger and Analysis\u003c\/li\u003e\n\u003cli\u003eMSO5000HD-I3C — Embedded Systems I3C Serial Bus Trigger and Analysis\u003c\/li\u003e\n\u003cli\u003eMSO5000HD-MANCH — Manchester Serial Bus Trigger and Analysis Option\u003c\/li\u003e\n\u003cli\u003eMSO5000HD-MIL1553 — MIL-STD-1553 Serial Bus Trigger and Analysis Option\u003c\/li\u003e\n\u003cli\u003eMSO5000HD-PWR — Advanced Power Analysis\u003c\/li\u003e\n\u003cli\u003eMSO5000HD-SENT — Automotive SENT Serial Bus Trigger and Analysis\u003c\/li\u003e\n\u003cli\u003eMSO5000HD-TIMING — Advanced Timing Analysis\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch4\u003eFAQ's\u003c\/h4\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003ch3 class=\"product-faq-question\"\u003eWhat protocols are included with the MSO5000HD as standard?\u003c\/h3\u003e\n\u003cp\u003eRS-232\/422\/485, UART, I²C, SPI, CAN, and LIN are decoded standard with no additional license required. CAN-FD, CAN-XL, FlexRay, SENT, Audio (I²S\/LJ\/RJ\/TDM), MIL-STD-1553B, ARINC 429, Manchester, 1-Wire, and I3C are available as separately licensed options — activated on the same instrument with no firmware upgrade or reflash required.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003ch3 class=\"product-faq-question\"\u003e\n\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003eWhat is the practical advantage of 12-bit native resolution over 8-bit?\u003c\/h3\u003e\n\u003cp\u003eA 12-bit ADC provides 4,096 vertical quantization levels compared to 256 for an 8-bit scope — sixteen times the resolution. In low-amplitude work (switching ripple riding on a DC rail, sensor outputs from a strain gauge, jitter on a clock line, or any signal where the amplitude of interest is much smaller than the channel’s full-scale range), 8-bit quantization steps show up as visible stair-stepping in the captured waveform. 12-bit acquisition keeps those steps below the front-end’s noise floor, so what you’re looking at on screen is the signal, not the digitization grid.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003ch3 class=\"product-faq-question\"\u003e\n\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003eHow do I add 16 digital channels for mixed-signal work?\u003c\/h3\u003e\n\u003cp\u003eThe 16-digital-channel logic-analyzer front end is built into every MSO5000HD chassis as hardware-standard. To use it, add the optional UT-M15 logic probe pod, which provides separate high 8-bit and low 8-bit pin connections and attaches directly to standard 2.54 mm 8×2 square-pin headers on development boards. Maximum digital sample rate is 1.25 GSa\/s with an 800 ps minimum detectable pulse width.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003ch3 class=\"product-faq-question\"\u003e\n\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003eWhat is the difference between Ultra Phosphor 3.0’s 800,000 wfms\/s standard rate and the 1,500,000 wfms\/s sequential-mode rate?\u003c\/h3\u003e\n\u003cp\u003eThe 800,000 wfms\/s rate is the continuous waveform-capture rate during normal acquisition — the rate at which the scope acquires, processes, and displays new waveforms back-to-back during live operation. The 1,500,000 wfms\/s sequential-mode rate applies in segmented-memory acquisition where the scope captures only a short window around each trigger event, then re-arms quickly for the next trigger; this maximizes capture density when chasing intermittent events at the cost of dead time between captures. In practical terms: continuous 800K for general-purpose acquisition, sequential 1.5M for rare-event hunting on a triggered signal.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003ch3 class=\"product-faq-question\"\u003e\n\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003eCan I control the MSO5000HD remotely without installing local software?\u003c\/h3\u003e\n\u003cp\u003eYes. The built-in WebServer provides full instrument control through any standard web browser on a PC, tablet, or mobile device on the same network — no client install, no driver download. Common operations (waveform capture, screenshot, parameter readback, settings changes, file export) work directly through the browser. For programmatic control, the same interface accepts SCPI commands over LAN or USB, compatible with LabVIEW, Python, MATLAB, and any SCPI-aware automation framework. UNI-T also provides a free instrument-manager application for users who prefer a graphical desktop client.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003ch3 class=\"product-faq-question\"\u003e\n\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003eWhat's the difference between the 50 Ω and 1 MΩ analog bandwidths on this 1 GHz model?\u003c\/h3\u003e\n\u003cp\u003eOn the MSO5104HD, the 50 Ω coupling path delivers the full 1 GHz analog bandwidth, while the 1 MΩ coupling path tops out at 500 MHz. Use 50 Ω with active probes, RF-grade passive probes, and high-speed signal-integrity work where source impedance matters; use 1 MΩ with standard 10x passive probes for general-purpose lab measurement up to 500 MHz. The vertical scale and offset ranges differ between paths — check the “Vertical System” section of the detailed specifications below for the per-path breakdown.\u003c\/p\u003e\n\u003ch4\u003eVideos\u003c\/h4\u003e\n\u003ciframe width=\"560\" height=\"315\" src=\"https:\/\/www.youtube.com\/embed\/ye2cyfV7DEo?si=K8mO9cTRtN3OZAc2\" title=\"YouTube video player\"\u003e\u003c\/iframe\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Uni-Trend US","offers":[{"title":"Default Title","offer_id":53265476681952,"sku":"181100300117X","price":5354.15,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/mso5104hd-1-ghz-4ch-12-bit-mixed-signal-oscilloscope-181100300117x-4303579.png?v=1782890829"},{"product_id":"mso8804hd-lab-grade-8-ghz-4ch-12-bit-mixed-signal-oscilloscope","title":"MSO8804HD Lab-Grade 8 GHz 4Ch 12-Bit Mixed Signal Oscilloscope","description":"\u003ch1\u003eThe UNI-T MSO8804HD 8 GHz 4-Channel Mixed Signal Oscilloscope is a high-performance laboratory instrument designed for signal integrity analysis, high-speed digital validation, compliance testing and advanced research applications. \u003c\/h1\u003e\n\u003cp\u003eFeaturing an 8 GHz analog bandwidth, up to 20 GSa\/s real-time sampling, and UNI-T's R12™ native 12-bit ADC architecture, the MSO8804HD delivers exceptional waveform accuracy for today's fastest electronic designs. Deep acquisition memory, ultra-fast waveform capture, and advanced software options make it an ideal solution for engineers working with PCIe, USB, Ethernet, DDR memory, and next-generation serial interfaces.\u003c\/p\u003e\n\u003cp\u003eDesigned for demanding development and test environments, the MSO8804HD combines high-performance hardware with powerful analysis tools in a single platform. A large 15.6-inch Full HD multi-touch display, hardware-accelerated protocol decoding, optional jitter and eye-diagram analysis, PAM-N measurements, and automated compliance testing provide the flexibility required for modern electronic design, validation, and production test.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e8 GHz analog bandwidth with four input channels\u003c\/li\u003e\n\u003cli\u003eUp to 20 GSa\/s real-time sampling (half-channel mode)\u003c\/li\u003e\n\u003cli\u003eNative 12-bit ADC architecture with up to 16-bit Enhanced Resolution (ERES)\u003c\/li\u003e\n\u003cli\u003e500 Mpts standard memory, expandable to 2 Gpts\u003c\/li\u003e\n\u003cli\u003eUltraAcq® acquisition with up to 1,000,000 waveforms per second\u003c\/li\u003e\n\u003cli\u003eSequential Mode with up to 520,000 waveform segments\u003c\/li\u003e\n\u003cli\u003e21+ serial protocol decoders across embedded, automotive, communications, and aerospace applications\u003c\/li\u003e\n\u003cli\u003eOptional jitter analysis, eye diagrams, and PAM-N analysis\u003c\/li\u003e\n\u003cli\u003eOptional USB 2.0 and Ethernet compliance test software\u003c\/li\u003e\n\u003cli\u003eEmbedded MATLAB compiler and full SCPI remote automation\u003c\/li\u003e\n\u003cli\u003eOptional 16-channel logic analyzer with UT-M15 logic probe\u003c\/li\u003e\n\u003cli\u003e15.6-inch Full HD capacitive multi-touch display\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eNative 12-Bit Performance\u003c\/h3\u003e\n\u003cp\u003eThe MSO8804HD is built on UNI-T's R12™ native 12-bit ADC architecture, providing significantly higher vertical resolution than conventional 8-bit oscilloscopes while maintaining the full 8 GHz bandwidth. The result is cleaner waveform acquisition, lower measurement noise, and improved visibility of low-level signal details, making the instrument well suited for high-speed digital, RF, and precision signal integrity applications.\u003c\/p\u003e\n\u003ch3\u003eUltra-Fast Acquisition and Deep Memory\u003c\/h3\u003e\n\u003cp\u003eWith UltraAcq® technology and Sequential Mode, the MSO8804HD captures up to one million waveforms per second while storing as many as 520,000 waveform segments for post-acquisition analysis. Combined with standard 500 Mpts memory, expandable to 2 Gpts, engineers can capture long-duration events, isolate intermittent faults, and analyze complex digital systems with confidence.\u003c\/p\u003e\n\u003ch3\u003eAdvanced Signal Integrity Analysis\u003c\/h3\u003e\n\u003cp\u003eOptional software packages expand the MSO8804HD beyond traditional oscilloscope measurements with comprehensive jitter analysis, real-time eye diagrams, clock recovery, and PAM-3 through PAM-7 signal analysis. These capabilities make the instrument an excellent platform for validating high-speed serial communications, optical networking, and advanced digital interfaces.\u003c\/p\u003e\n\u003ch3\u003eProtocol Decoding and Mixed Signal Debugging\u003c\/h3\u003e\n\u003cp\u003eThe MSO8804HD supports more than 21 serial communication protocols covering embedded systems, automotive electronics, computer interfaces, and aerospace applications. Standard decoding includes UART, RS-232\/422\/485, I²C, SPI, CAN, and LIN, while additional protocols are available through optional software licenses. An optional UT-M15 logic probe adds 16 synchronized digital channels for comprehensive mixed-signal debugging.\u003c\/p\u003e\n\u003ch3\u003eAutomation and Compliance Testing\u003c\/h3\u003e\n\u003cp\u003eEmbedded MATLAB scripting and full SCPI remote control over LAN, USB, and the integrated WebServer simplify automated testing and custom analysis. Optional USB 2.0 and Ethernet compliance software guides engineers through standardized physical-layer testing with automated measurements, pass\/fail reporting, and detailed test documentation.\u003c\/p\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cp\u003eThe UNI-T MSO8804HD is ideal for high-speed digital design, signal integrity engineering, semiconductor development, communications research, embedded system validation, compliance testing, aerospace electronics, and advanced laboratory applications. Its combination of native 12-bit performance, high bandwidth, flexible analysis software, and integrated automation tools provides engineers with a powerful platform for developing and validating today's most demanding electronic systems.\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAnalog Bandwidth (50 Ω, −3 dB)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 GHz half-channel, 4 GHz full-channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRise Time (50 Ω, Typ.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤55 ps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAnalog Channels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 + 1 external trigger\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDigital Channels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 (with optional UT-M15 logic probe pod)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReal-Time Sample Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 GSa\/s (half-channel) \/ 10 GSa\/s (full-channel)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVertical Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12-bit native (up to 16-bit with ERES)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMemory Depth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 Mpts\/CH std (full-channel), 1 Gpts\/CH std (half-channel); 1 Gpts\/CH or 2 Gpts\/CH optional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWaveform Capture Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≥1,000,000 wfms\/s (Sequential Mode); UltraAcq® up to 300,000 wfms\/s standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eENOB (Typ.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;7 bits at 50 Ω, 50 mV\/div, −3 dBFS, full system bandwidth\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInherent Jitter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤150 fs RMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSFDR (Typ.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≥50 dBc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNoise Floor (Typ.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤800 µVrms at 50 mV\/div, full bandwidth; as low as 390 µVrms at 1–10 mV\/div\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChannel-to-Channel Isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≥600:1 (DC–4 GHz, all channel combinations); ≥500:1 (\u0026gt;4 GHz, C1+C3 simultaneous)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrigger Types\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e22+ types: edge, pulse width, video, runt, slope\/ramp, timeout, setup \u0026amp; hold, Nth edge, code pattern, over-amplitude, delay, duration; advanced, protocol, and zone triggering\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtocol Decoding (Standard)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRS-232\/422\/485\/UART, I²C, SPI, CAN, LIN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtocol Decoding (Optional)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCAN-FD, FlexRay, SENT, AudioBus (I²S\/LJ\/RJ\/TDM), MIL-STD-1553B, ARINC 429, SMBus, SPMI, I3C, PSI5, USB 2.0, PCIe 2.0, Ethernet, NRZ, Manchester, 8b\/10b\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBuilt-in AWG (Optional, MSO8000HD-AWG)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDual-channel, 60 MHz max output, 625 MSa\/s, sine\/square\/pulse\/ramp\/noise\/DC + 200+ arbitrary; AM\/FM\/sweep modulation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDigital Voltmeter \/ Frequency Counter (Standard)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4-digit DVM (DC, AC RMS, DC+AC RMS); 8-digit hardware frequency counter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAutomated Measurements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e52 types; quick Meas, statistical analysis, histogram, trend chart, trace analysis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdvanced Analysis (Optional)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eJitter analysis and eye diagram (MSO8000HD-JITTER); PAM-N analysis (PAM-3 through PAM-7); limit template testing; USB 2.0 conformance (CTSUSB20); Ethernet conformance (CTS100)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMath Operations\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 8 math waveforms; enhanced FFT (1 Mpts); IIR\/FIR filters; embedded MATLAB compiler (Optional); advanced filter designer (Optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15.6-inch FHD touch screen (1920×1080); capacitive multi-touch; gesture support; dynamic multi-window\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnectivity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSB Host 3.0 (4× Type-A, 1× Type-C); USB Device; LAN 10\/100\/1000 Mbps; HDMI; AUX In\/Out (trigger sync, AWG trig, pass\/fail); 10 MHz Ref In\/Out\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRemote Control\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSCPI over LAN\/USB; built-in WebServer for browser-based control (PC and mobile); UNI-T Instrument Manager (free, PC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eArchitecture\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAFE ASIC (UNI-T self-developed); seventh-generation oscilloscope platform; precision \u0026gt;10 GHz BNC connectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCE, cTUVus, RoHS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003e\n\u003cbr\u003eDownloads\u003c\/h4\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cbr\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cstrong\u003e\u003ca title=\"UPO1000 Series Datasheet\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/MSO8000_-_Data_Sheet.pdf?v=1782931835\" target=\"_blank\"\u003e\u003cimg alt=\"PDF\" style=\"float: left;\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/pdf-icon-63x63_480x480.png\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/850009-i.pdf\" target=\"_blank\"\u003e\u003cbr\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/MSO8000_-_Data_Sheet.pdf?v=1782931835\" title=\"UNI-T UPO1000 Series Datasheet\" rel=\"noopener\" target=\"_blank\"\u003eUNI-T MSO8000 Series Datasheet\u003c\/a\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eOptions \u0026amp; Accessories\u003c\/h4\u003e\n\u003ch3\u003eIncluded in Box\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e2x SMA cables, 2x BNC-SMA adapters, 2x BNC-BNC cables, USB 3.0 data cable\u003c\/li\u003e\n\u003cli\u003ePower cord (region-specific)\u003c\/li\u003e\n\u003cli\u003eEnglish download guide, multi-language safety manual\u003c\/li\u003e\n\u003cli\u003eCalibration certificate (COC)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eRecommended Add-Ons\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eUT-M15 Logic Probe Pod\u003c\/strong\u003e — adds 16 digital channels; 1.25 GSa\/s, 101 kΩ ±1% input impedance, 8×2 square-pin attachment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eActive probes\u003c\/strong\u003e — UT-PA2000 (2 GHz single-ended) and UT-PD2500 (2.5 GHz differential) for high-bandwidth signal-integrity work.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMSO8000HD-AWG\u003c\/strong\u003e — activates the dual-channel 60 MHz AWG (625 MSa\/s, 200+ built-in waveforms).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMSO8000HD-LA\u003c\/strong\u003e — logic analyzer license (paired with UT-M15).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMSO8000HD-JITTER\u003c\/strong\u003e — jitter and eye-diagram measurement suite.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMSO8000HD-CTSUSB20 \/ CTS100\u003c\/strong\u003e — USB 2.0 and 100Base-Tx Ethernet conformance test packages.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtocol decoder licenses\u003c\/strong\u003e — CAN-FD, FlexRay, SENT, AudioBus, MIL-STD-1553B, ARINC 429, I3C, PSI5, USB 2.0, PCIe 2.0, Ethernet, NRZ, Manchester, 8b\/10b, SMBus, SPMI — individually or bundled in the MSO8000HD-BND upgrade kit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUT-ISOT, UT-PR2060, UT-M13X\u003c\/strong\u003e — isolation transformer, probe rack, demo board.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003cmeta charset=\"utf-8\"\u003e\u003c\/p\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch4\u003eFAQ's\u003c\/h4\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003ch3 class=\"product-faq-question\"\u003e\n\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003eWhat protocols are included with the MSO8804HD as standard?\u003c\/h3\u003e\n\u003cp\u003eRS-232\/422\/485, UART, I²C, SPI, CAN, and LIN are decoded standard with no additional license required. The remaining 16 protocols — CAN-FD, FlexRay, SENT, AudioBus (I²S\/LJ\/RJ\/TDM), MIL-STD-1553B, ARINC 429, SMBus, SPMI, I3C, PSI5, USB 2.0, PCIe 2.0, 10\/100 Mbps Ethernet, NRZ, Manchester, and 8b\/10b — are available as separately licensed options or bundled in the MSO8000HD-BND upgrade kit. Each option activates on the same instrument with no firmware reflash or hardware swap.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003ch3 class=\"product-faq-question\"\u003e\n\u003cbr\u003eWhat is the practical advantage of native 12-bit resolution over 8-bit on a high-bandwidth oscilloscope?\u003c\/h3\u003e\n\u003cp\u003eA 12-bit ADC provides 4,096 vertical quantization levels versus 256 for an 8-bit scope — sixteen times the resolution. At 8 GHz of bandwidth, the measurements that matter most (eye diagrams, jitter, return-loss artifacts) typically involve amplitudes much smaller than the channel’s full-scale range. On an 8-bit scope, low-amplitude artifacts get buried in quantization steps; on the MSO8804HD, 12-bit resolution combined with \u0026gt;7 bits of ENOB at full bandwidth keeps those artifacts above the noise floor and below the quantization grid.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003ch3 class=\"product-faq-question\"\u003e\n\u003cbr\u003eDoes the MSO8804HD include built-in power analysis?\u003c\/h3\u003e\n\u003cp\u003eNo. The advanced power analysis package on the MSO8000HD series is available only on the MSO8504HD model (5 GHz). The MSO8804HD focuses on high-speed signal-integrity work at 8 GHz — jitter analysis, eye diagrams, PAM-N validation, and conformance testing. For power-electronics validation, UNI-T’s MSO5000HD and MSO3000HD series include the optional power-analysis suite at lower bandwidth tiers where switching frequencies match the bandwidth requirement more efficiently.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003ch3 class=\"product-faq-question\"\u003e\n\u003cbr\u003eHow do I add 16 digital channels for mixed-signal work?\u003c\/h3\u003e\n\u003cp\u003eThe 16-digital-channel logic-analyzer front end is built into every MSO8804HD chassis as hardware-standard. Add the optional UT-M15 logic probe pod to use it — separate high\/low 8-bit connectors, direct attachment to 2.54 mm 8×2 square-pin headers, 1.25 GSa\/s digital sample rate, 3.2 ns minimum pulse width, 101 kΩ ±1% input impedance. The MSO8000HD-LA license activates the logic-analyzer feature.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003ch3 class=\"product-faq-question\"\u003e\n\u003cbr\u003eCan I run my own MATLAB analysis scripts directly on the instrument?\u003c\/h3\u003e\n\u003cp\u003eYes. The MSO8804HD includes an embedded MATLAB code compiler that executes scripts directly on the oscilloscope, with results rendered as mathematical waveforms in the display window. Scripts save, recall, and reuse across sessions, and combined with full SCPI automation over LAN, USB, and the WebServer, the instrument supports hybrid on-instrument and desktop-MATLAB analysis workflows.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003ch3 class=\"product-faq-question\"\u003e\n\u003cbr\u003eWhich channel-pair combinations support the full 8 GHz bandwidth?\u003c\/h3\u003e\n\u003cp\u003eThe full 8 GHz \/ 20 GSa\/s spec is available with only C1 enabled, only C3 enabled, or C1 and C3 enabled simultaneously. Any other combination — C1+C2, C2+C4, all four channels — runs in full-channel mode at 4 GHz \/ 10 GSa\/s. Channel-to-channel isolation reflects this: ≥600:1 from DC–4 GHz applies to any combination, while ≥500:1 above 4 GHz is specified for the C1+C3 simultaneous case where high-frequency dual-channel work is most common.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch4\u003eVideos\u003cbr\u003e\u003cbr\u003e\n\u003c\/h4\u003e\n\u003ciframe width=\"560\" height=\"315\" src=\"https:\/\/www.youtube.com\/embed\/IwPuhv2P2TU?si=lDjfr7LXMogFtzoM\" title=\"YouTube video player\"\u003e\u003c\/iframe\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/div\u003e","brand":"Uni-Trend US","offers":[{"title":"Default Title","offer_id":53265476780256,"sku":"181100300155X","price":70999.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/MSO8804HD_1_sq.jpg?v=1782858089"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/collections\/oscilloscopes-9222702.png?v=1784904313","url":"https:\/\/sper-direct.myshopify.com\/collections\/oscilloscopes.oembed","provider":"Sper Scientific Direct","version":"1.0","type":"link"}