{"title":"Pharmaceuticals","description":"\u003cp\u003e\u003cstrong\u003ePharmaceutical testing and process monitoring depend on measurements suited to the material, process and working environment.\u003c\/strong\u003e Instruments for water quality, laboratory analysis and bioprocess monitoring help teams collect the information they need throughout development and production.\u003c\/p\u003e\n\u003cp\u003eExplore sensors, meters and laboratory instruments for pharmaceutical applications. Check measurement ranges, material compatibility and installation requirements when selecting equipment for your process.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAlso see:\u003c\/strong\u003e\u003cbr\u003e\u003ca href=\"https:\/\/sperdirect.com\/collections\/bioprocess-monitoring-analytics\"\u003e\u003cstrong\u003eBioprocess Monitoring\u003c\/strong\u003e\u003c\/a\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e","products":[{"product_id":"ultrasonic-level-meter","title":"Integrated Ultrasonic Level Meter","description":"\u003ch1\u003eThe Ultrasonic Level Meter combines the strengths of various level measurement instruments into a fully digital and user-friendly system.\u003c\/h1\u003e\n\u003cp\u003eIt offers reliable level monitoring, seamless data transmission, and intuitive human-machine interaction. With robust anti-interference capabilities, customizable upper and lower limits, and online output adjustments, it supports on-site display and multiple output options, including analog, switching and RS485 for easy integration with control systems. \u003c\/p\u003e\n\u003cp\u003eConstructed with a waterproof engineering plastic cover and ABS probe, it suits diverse level measurement applications. Additional modules like RS485 and current output can be added for enhanced compatibility with PLCs. Key features include wide DC12-24V voltage range, parameter backup and recovery, flexible analog output adjustment, filter settings to eliminate noise, customizable serial data formats, and adjustable pulse intensity for measuring air gaps or liquid levels.\u003c\/p\u003e\n\u003cp class=\"p1\"\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli class=\"p1\"\u003eDC12-24V wide work voltage\u003c\/li\u003e\n\u003cli class=\"p1\"\u003eBackup and recovery parameter set\u003c\/li\u003e\n\u003cli class=\"p1\"\u003eFree adjustment of the range of analog output\u003c\/li\u003e\n\u003cli class=\"p1\"\u003eSet a filter value to remove\u003c\/li\u003e\n\u003cli class=\"p1\"\u003eCustom serial port data format\u003c\/li\u003e\n\u003cli class=\"p1\"\u003eMeasure measure air space or liquid level\u003c\/li\u003e\n\u003cli class=\"p1\"\u003e1-15 transmitted pulse intensity depending on working conditions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003eOrdering Notes:\u003cbr\u003e\u003c\/b\u003e\u003cb\u003e\u003cspan\u003e\u003cspan style=\"color: #ff2a00;\"\u003eAll Inline Water Quality Meters and Sensors ship direct from the factory. Please allow 10-15 business days for shipping and \u003cspan style=\"caret-color: rgb(255, 42, 0);\"\u003ehandling\u003c\/span\u003e. \u003c\/span\u003e\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable style=\"border-collapse: collapse; width: 654pt; box-sizing: border-box; outline: 0px; border-spacing: 0px; font-variant-ligatures: normal; font-variant-caps: normal; orphans: 2; widows: 2; -webkit-text-stroke-width: 0px; text-decoration-thickness: initial; text-decoration-style: initial; text-decoration-color: initial; height: 301px;\" width=\"872\" cellspacing=\"0\" cellpadding=\"0\" border=\"0\"\u003e\n\u003ccolgroup\u003e \u003ccol style=\"width: 296px;\" width=\"296\"\u003e \u003ccol style=\"width: 575px;\" width=\"576\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 24px; box-sizing: border-box; outline: 0px;\" height=\"24\"\u003e\n\u003ctd style=\"height: 24px; width: 222pt; box-sizing: border-box; outline: 0px;\" width=\"296\" class=\"xl63\" height=\"24\"\u003e\u003cspan style=\"box-sizing: border-box; outline: 0px;\"\u003eRange\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 432pt; box-sizing: border-box; outline: 0px; height: 24px;\" width=\"576\" class=\"xl63\"\u003e\u003cspan style=\"box-sizing: border-box; outline: 0px;\"\u003e5, 8, 10, 12, 15m\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 13px;\"\u003e\n\u003ctd style=\"box-sizing: border-box; outline: 0px; height: 13px;\"\u003e\u003cspan style=\"box-sizing: border-box; outline: 0px; height: 13px;\"\u003eAccuracy\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"box-sizing: border-box; outline: 0px; height: 13px;\"\u003e±0.3%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 24px; box-sizing: border-box; outline: 0px;\" height=\"24\"\u003e\n\u003ctd style=\"height: 24px; box-sizing: border-box; outline: 0px;\" class=\"xl63\" height=\"24\"\u003e\u003cspan style=\"box-sizing: border-box; outline: 0px;\"\u003eBlind Zone\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"box-sizing: border-box; outline: 0px; height: 24px;\" class=\"xl64\"\u003e\u003cspan style=\"box-sizing: border-box; outline: 0px;\"\u003e＜\u003cspan class=\"font5\"\u003e0.3-0.5m (different for range)\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 24px; box-sizing: border-box; outline: 0px;\" height=\"24\"\u003e\n\u003ctd style=\"height: 24px; box-sizing: border-box; outline: 0px;\" class=\"xl63\" height=\"24\"\u003e\u003cspan style=\"box-sizing: border-box; outline: 0px;\"\u003eDisplay resolution\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"box-sizing: border-box; outline: 0px; height: 24px;\" class=\"xl63\"\u003e\u003cspan style=\"box-sizing: border-box; outline: 0px;\"\u003e1mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 24px; box-sizing: border-box; outline: 0px;\" height=\"24\"\u003e\n\u003ctd style=\"height: 24px; box-sizing: border-box; outline: 0px;\" class=\"xl63\" height=\"24\"\u003e\u003cspan style=\"box-sizing: border-box; outline: 0px;\"\u003eFrequency\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"box-sizing: border-box; outline: 0px; height: 24px;\" class=\"xl63\"\u003e\u003cspan style=\"box-sizing: border-box; outline: 0px;\"\u003e20~350KHz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 24px; box-sizing: border-box; outline: 0px;\" height=\"24\"\u003e\n\u003ctd style=\"height: 24px; box-sizing: border-box; outline: 0px;\" class=\"xl63\" height=\"24\"\u003e\u003cspan style=\"box-sizing: border-box; outline: 0px;\"\u003ePower\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"box-sizing: border-box; outline: 0px; height: 24px;\" class=\"xl63\"\u003e\u003cspan style=\"box-sizing: border-box; outline: 0px;\"\u003e12-24VDC; consumption:\u0026lt;1.5W\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 24px; box-sizing: border-box; outline: 0px;\" height=\"24\"\u003e\n\u003ctd style=\"height: 24px; box-sizing: border-box; outline: 0px;\" class=\"xl63\" height=\"24\"\u003e\u003cspan style=\"box-sizing: border-box; outline: 0px;\"\u003eOutput\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"box-sizing: border-box; outline: 0px; height: 24px;\" class=\"xl63\"\u003e\u003cspan style=\"box-sizing: border-box; outline: 0px;\"\u003e4~20mA RL\u0026gt;600\u003cspan class=\"font6\"\u003eΩ\u003c\/span\u003e\u003cspan class=\"font5\"\u003e(standard),1~5V\\1~10V\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 24px; box-sizing: border-box; outline: 0px;\" height=\"24\"\u003e\n\u003ctd style=\"height: 24px; box-sizing: border-box; outline: 0px;\" class=\"xl63\" height=\"24\"\u003e\u003cspan style=\"box-sizing: border-box; outline: 0px;\"\u003eCommunication\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"box-sizing: border-box; outline: 0px; height: 24px;\" class=\"xl63\"\u003e\u003cspan style=\"box-sizing: border-box; outline: 0px;\"\u003eRS485\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 24px; box-sizing: border-box; outline: 0px;\" height=\"24\"\u003e\n\u003ctd style=\"height: 24px; box-sizing: border-box; outline: 0px;\" class=\"xl63\" height=\"24\"\u003e\u003cspan style=\"box-sizing: border-box; outline: 0px;\"\u003eRelay\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"box-sizing: border-box; outline: 0px; height: 24px;\" class=\"xl63\"\u003e\u003cspan style=\"box-sizing: border-box; outline: 0px;\"\u003e2 NPN relays (AC: 5A 250V DC: 10A 24V)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 24px; box-sizing: border-box; outline: 0px;\" height=\"24\"\u003e\n\u003ctd style=\"height: 24px; box-sizing: border-box; outline: 0px;\" class=\"xl63\" height=\"24\"\u003e\u003cspan style=\"box-sizing: border-box; outline: 0px;\"\u003eMaterial\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"box-sizing: border-box; outline: 0px; height: 24px;\" class=\"xl63\"\u003e\u003cspan style=\"box-sizing: border-box; outline: 0px;\"\u003eABS\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 24px; box-sizing: border-box; outline: 0px;\" height=\"24\"\u003e\n\u003ctd style=\"height: 24px; box-sizing: border-box; outline: 0px;\" class=\"xl63\" height=\"24\"\u003e\u003cspan style=\"box-sizing: border-box; outline: 0px;\"\u003eDimension\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"box-sizing: border-box; outline: 0px; height: 24px;\" class=\"xl64\"\u003e\u003cspan style=\"box-sizing: border-box; outline: 0px;\"\u003eΦ\u003cspan class=\"font5\"\u003e92mm \u003c\/span\u003e\u003cspan class=\"font6\"\u003e× \u003c\/span\u003e\u003cspan class=\"font5\"\u003e198mm \u003c\/span\u003e\u003cspan class=\"font6\"\u003e× \u003c\/span\u003e\u003cspan class=\"font5\"\u003eM60\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 24px; box-sizing: border-box; outline: 0px;\" height=\"24\"\u003e\n\u003ctd style=\"height: 24px; box-sizing: border-box; outline: 0px;\" class=\"xl63\" height=\"24\"\u003e\u003cspan style=\"box-sizing: border-box; outline: 0px;\"\u003eProtection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"box-sizing: border-box; outline: 0px; height: 24px;\" class=\"xl63\"\u003e\u003cspan style=\"box-sizing: border-box; outline: 0px;\"\u003eIP65 (others optional)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 24px; box-sizing: border-box; outline: 0px;\" height=\"24\"\u003e\n\u003ctd style=\"height: 24px; box-sizing: border-box; outline: 0px;\" class=\"xl63\" height=\"24\"\u003e\u003cspan style=\"box-sizing: border-box; outline: 0px;\"\u003eConnection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"box-sizing: border-box; outline: 0px; height: 24px;\" class=\"xl63\"\u003e\u003cspan style=\"box-sizing: border-box; outline: 0px;\"\u003eElectrical interface: M20X1.5, Installation: M60X2 or ￠61MM\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Sper Scientific","offers":[{"title":"Default Title","offer_id":46246435094752,"sku":"870010","price":568.1,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/integrated-ultrasonic-level-meter-870010-7414059.jpg?v=1760646507"},{"product_id":"inline-industrial-conductivity-electrode","title":"Online Industrial Conductivity Electrode","description":"\u003ch1\u003eThe Industrial Conductivity Series electrodes are purpose-built for precise conductivity measurements in pure water, ultra-pure water and water treatment applications.\u003c\/h1\u003e\n\u003cp\u003eThese electrodes are especially suitable for use in thermal power plants and the water treatment industry, where durability and accuracy are critical. Featuring a robust double-cylinder structure made from titanium alloy, they naturally oxidize to form a chemically passive layer, enhancing resistance to various liquids (excluding hydrofluoric acid). Temperature compensation components are available in multiple options, including NTC2.252K, 2K, 10K, 20K, 30K, PT100, and PT1000, which can be specified based on user needs.\u003c\/p\u003e\n\u003cp\u003eThe K=10.0 or K=30 electrodes in this series incorporate a large-area platinum structure, providing excellent resistance to strong acids and alkalis as well as high anti-fouling capacity. These electrodes are well-suited for on-line conductivity measurement in demanding industries such as wastewater treatment and seawater purification.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDouble-cylinder structure with corrosion-resistant titanium alloy\u003c\/li\u003e\n\u003cli\u003eNaturally oxidized, chemically passive surface for improved durability\u003c\/li\u003e\n\u003cli\u003eMultiple temperature compensation options: NTC2.252K, 2K, 10K, 20K, 30K, PT100, PT1000\u003c\/li\u003e\n\u003cli\u003eLarge-area platinum structure on K=10.0 and K=30 models for resistance to strong acids and alkalis\u003c\/li\u003e\n\u003cli\u003eExcellent anti-fouling capacity, ideal for specialized industrial applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003eOrdering Notes: \u003cbr\u003e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003e1. All Sper Inline \u003ca href=\"https:\/\/sperdirect.com\/collections\/inline-water-quality-monitors-sensors\" title=\"Inline Water Quality Monitoring\"\u003eWater Quality Meters and Sensors\u003c\/a\u003e are sold separately - one of each is required for a complete system. \u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003e\u003cspan\u003e\u003cspan style=\"color: #ff2a00;\"\u003e2. All Inline Water Quality Meters and Sensors ship direct from the factory. Please allow 10-15 business days for shipping and \u003cspan style=\"caret-color: rgb(255, 42, 0);\"\u003ehandling\u003c\/span\u003e. \u003c\/span\u003e\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003ctable style=\"height: 245px;\" class=\"MsoNormalTable\" border=\"0\" cellspacing=\"0\" cellpadding=\"0\" width=\"715\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 35px;\"\u003e\n\u003ctd style=\"height: 35px;\" width=\"155\" nowrap\u003e\n\u003cp style=\"text-align: left;\" class=\"MsoNormal\" align=\"center\"\u003e\u003cb\u003e\u003cspan\u003eProbe\u003c\/span\u003e\u003c\/b\u003e\u003cb\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"112\" nowrap\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cb\u003e\u003cspan\u003e870003-ICE-01\u003c\/span\u003e\u003c\/b\u003e\u003cb\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"112\" nowrap\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cb\u003e\u003cspan\u003e870003-ICE-02\u003c\/span\u003e\u003c\/b\u003e\u003cb\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"112\" nowrap\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cb\u003e\u003cspan\u003e870003-ICE-03\u003c\/span\u003e\u003c\/b\u003e\u003cb\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"112\" nowrap\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cb\u003e\u003cspan\u003e870003-ICE-04\u003c\/span\u003e\u003c\/b\u003e\u003cb\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"112\" nowrap\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cb\u003e\u003cspan\u003e870003-ICE-05\u003c\/span\u003e\u003c\/b\u003e\u003cb\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35px;\"\u003e\n\u003ctd style=\"height: 35px;\" width=\"155\" nowrap\u003e\n\u003cp style=\"text-align: left;\" class=\"MsoNormal\" align=\"center\"\u003e\u003cb\u003e\u003cspan\u003eCC\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"112\" nowrap\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e0.01\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"112\" nowrap\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e0.1\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"112\" nowrap\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e1.0\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"112\" nowrap\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e10\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"112\" nowrap\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e30\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35px;\"\u003e\n\u003ctd style=\"height: 35px;\" width=\"155\" nowrap\u003e\n\u003cp style=\"text-align: left;\" class=\"MsoNormal\" align=\"center\"\u003e\u003cb\u003e\u003cspan\u003eEC Range\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"112\" nowrap\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e0-2μS\/cm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"112\" nowrap\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e0-200μS\/cm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"112\" nowrap\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e0-2000μS\/cm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"112\" nowrap\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e0-20000μS\/cm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"112\" nowrap\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e30-600mS\/cm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35px;\"\u003e\n\u003ctd style=\"height: 35px;\" width=\"155\" nowrap\u003e\n\u003cp style=\"text-align: left;\" class=\"MsoNormal\" align=\"center\"\u003e\u003cb\u003e\u003cspan\u003eTemp Range\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"112\" nowrap\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e0.0-100.0°C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"112\" nowrap\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e0.0-100.0°C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"112\" nowrap\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e0.0-100.0°C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"112\" nowrap\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e0.0-100.0°C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"112\" nowrap\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e0.0-100.0°C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35px;\"\u003e\n\u003ctd style=\"height: 35px;\" width=\"155\" nowrap\u003e\n\u003cp style=\"text-align: left;\" class=\"MsoNormal\" align=\"center\"\u003e\u003cb\u003e\u003cspan\u003eAccuracy\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"560\" nowrap colspan=\"5\"\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e2%, ±0.5°C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35px;\"\u003e\n\u003ctd style=\"height: 35px;\" width=\"155\" nowrap\u003e\n\u003cp style=\"text-align: left;\" class=\"MsoNormal\" align=\"center\"\u003e\u003cb\u003e\u003cspan\u003eWithstand pressure\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"560\" nowrap colspan=\"5\"\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e0.4MPa\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35px;\"\u003e\n\u003ctd style=\"height: 35px;\" width=\"155\" nowrap\u003e\n\u003cp style=\"text-align: left;\" class=\"MsoNormal\" align=\"center\"\u003e\u003cb\u003e\u003cspan\u003eWaterproof Level\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"560\" nowrap colspan=\"5\"\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003eIP68\/NEMA6P\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable border=\"0\" style=\"width: 100%; height: 430px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 38px;\"\u003e\n\u003ctd style=\"width: 21.721869%; height: 38px;\"\u003e\u003cspan\u003eConstant of electrode\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 28.232759%; height: 38px;\"\u003e\u003cspan\u003e0.1\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd rowspan=\"6\" style=\"width: 46.058303%; height: 430px;\"\u003e\u003cspan\u003e\u003cimg src=\"https:\/\/www.boquinstruments.com\/uploads\/DDG-0.1-Industrial-Conductivity-Sensor.jpg\" alt=\"DDG-0.1 Industrial Conductivity Sensor\" class=\"alignnone size-full wp-image-2585\"\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 38px;\"\u003e\n\u003ctd style=\"width: 21.721869%; height: 38px;\"\u003e\u003cspan\u003eCompressive strength\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 28.232759%; height: 38px;\"\u003e\u003cspan\u003e0.6 MPa\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 21.721869%; height: 19px;\"\u003e\u003cspan\u003eMeasuring range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 28.232759%; height: 19px;\"\u003e\u003cspan\u003e0-2000 uS\/em\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 38px;\"\u003e\n\u003ctd style=\"width: 21.721869%; height: 38px;\"\u003e\u003cspan\u003eConnection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 28.232759%; height: 38px;\"\u003e\u003cspan\u003e1\/2 or 3\/4 Thread Installation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 38px;\"\u003e\n\u003ctd style=\"width: 21.721869%; height: 38px;\"\u003e\u003cspan\u003eMaterial\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 28.232759%; height: 38px;\"\u003e\n\u003cspan\u003e316L Titanium Alloy \u003cbr\u003eand \u003c\/span\u003ePlatinum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 259px;\"\u003e\n\u003ctd style=\"width: 21.721869%; height: 259px;\"\u003e\u003cspan\u003eApplication\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 28.232759%; height: 259px;\"\u003e\u003cspan\u003eWater Treatment Industry\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4\u003eDownloads\u003c\/h4\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cstrong\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/860031-33-i.pdf?v=1598908093\" target=\"_blank\"\u003e \u003c\/a\u003e\u003ca rel=\"noopener\" title=\"Inline Industrial Conductivity Sensor - Users Manual\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/Inductive_Conductivity_Sensor_-_Users_Manual.pdf\" target=\"_blank\"\u003e\u003cimg style=\"float: left;\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/pdf-icon-63x63_480x480.png?v=1598991821\" alt=\"PDF\"\u003e \u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/860031-33-i.pdf?v=1598908093\" target=\"_blank\"\u003e\u003cbr\u003e\u003c\/a\u003e\u003ca rel=\"noopener\" title=\"Inline Industrial Conductivity Sensor - Users Manual\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/Inductive_Conductivity_Sensor_-_Users_Manual.pdf\" target=\"_blank\"\u003eInstruction Manual\u003c\/a\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e","brand":"Sper Scientific","offers":[{"title":"870003-ICE-01","offer_id":52569194791136,"sku":"870003-ICE-01","price":170.89,"currency_code":"USD","in_stock":true},{"title":"870003-ICE-02","offer_id":52569194823904,"sku":"870003-ICE-02","price":170.89,"currency_code":"USD","in_stock":true},{"title":"870003-ICE-03","offer_id":52569194856672,"sku":"870003-ICE-03","price":170.89,"currency_code":"USD","in_stock":true},{"title":"870003-ICE-04","offer_id":52569194889440,"sku":"870003-ICE-04","price":170.89,"currency_code":"USD","in_stock":true},{"title":"870003-ICE-05","offer_id":52569194922208,"sku":"870003-ICE-05","price":170.89,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/inline-industrial-conductivity-electrode-870003-ice-994131.jpg?v=1752691912"},{"product_id":"industrial-conductivity-tds-salinity-resistivity-meter","title":"Online Industrial Conductivity, TDS, Salinity, Resistivity Meter","description":"\u003cp\u003e\u003cb\u003eOrdering Notes:\u003cbr\u003e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003e1. ALL SPER ONLINE WATER QUALITY METERS AND SENSORS ARE SOLD SEPARATELY - Please be sure to add the appropriate sensor (listed above) when purchasing your meter - ONE METER AND SENSOR are required for a complete system. \u003c\/span\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003e\u003cspan\u003e\u003cspan style=\"color: #ff2a00;\"\u003e2. All Inline Water Quality Meters and Sensors ship direct from the factory. Please allow 10-15 business days for shipping and \u003cspan style=\"caret-color: rgb(255, 42, 0);\"\u003ehandling\u003c\/span\u003e. \u003c\/span\u003e\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eOur Industrial Conductivity, TDS, Salinity and Resistance Meter is essential for inline monitoring of water conductivity in applications like drinking water treatment, industrial water and boiler water.\u003c\/h1\u003e\n\u003cp\u003eConductivity measurements provide valuable insight into the amount of dissolved material in water. We offer a wide range of high-quality, affordable conductivity sensors, suitable for everything from deionized water to highly saturated brines. \u003c\/p\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cspan\u003eWhy is conductivity measurement important in water treatment? The conductivity of water is crucial because it gives an indication of the amount of dissolved material within that water. \u003cmeta charset=\"utf-8\"\u003ePaired with Sper Scientific conductivity controllers, this meter delivers reliable, cost-effective process control across industries.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMulti-functional: Measures conductivity, TDS, resistivity, salinity, and temperature\u003c\/li\u003e\n\u003cli\u003eReliable conductivity monitoring for consistent results\u003c\/li\u003e\n\u003cli\u003eEasy system integration for seamless conductivity measurement\u003c\/li\u003e\n\u003cli\u003eIdeal for all water quality environments\u003c\/li\u003e\n\u003cli\u003eCompatible with contact conductivity sensors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable class=\"table table-bordered table-hover\" data-sort=\"sortDisabled\" style=\"width: 70.766488%;\" height=\"750\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd width=\"220\" style=\"width: 40.929401%;\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd rowspan=\"1\" colspan=\"2\" width=\"97\" style=\"width: 57.829181%;\"\u003e\n\u003cp\u003e\u003cstrong\u003eInline Conductivity Meter\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"220\" style=\"width: 40.929401%;\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eMeasurement\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd rowspan=\"1\" colspan=\"2\" width=\"97\" style=\"width: 57.829181%;\"\u003e\u003cspan\u003eConductivity, TDS, Resistivity, Salinity, Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"220\" style=\"width: 40.929401%;\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd rowspan=\"1\" colspan=\"2\" width=\"97\" style=\"width: 57.829181%;\"\u003e\n\u003cp\u003e0.00uS\/cm~2000000.00 uS\/cm(0.00uS\/cm~2000.00 mS\/cm)\u003c\/p\u003e\n\u003cp\u003e0.00g\/L~80.00 g\/L (ppt)\u003c\/p\u003e\n\u003cp\u003e0.00mg\/L~130000.00 mg\/L (ppm)\u003c\/p\u003e\n\u003cp\u003e0.00MΩ~20.00MΩ\u003c\/p\u003e\n\u003cp\u003e-40.0℃~200.0℃ (refer to matching electrode)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"1\" colspan=\"1\" width=\"220\" style=\"width: 40.929401%;\"\u003e\u003cspan\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd rowspan=\"1\" colspan=\"2\" width=\"97\" style=\"width: 57.829181%;\"\u003e\u003cspan\u003e1%,  ±0.2℃\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"220\" style=\"width: 40.929401%;\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eHousing Material\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\" width=\"97\" style=\"width: 57.829181%;\"\u003e\n\u003cp\u003e\u003cspan\u003eABS Flame retardant : V0\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"220\" style=\"width: 40.929401%;\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003ePower\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\" width=\"97\" style=\"width: 57.829181%;\"\u003e\n\u003cp\u003e\u003cspan\u003e90 – 260V AC 50\/60Hz\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"220\" style=\"width: 40.929401%;\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eConsumption\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\" width=\"97\" style=\"width: 57.829181%;\"\u003e\n\u003cp\u003e\u003cspan\u003e4W\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"220\" style=\"width: 40.929401%;\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOutput\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\" width=\"97\" style=\"width: 57.829181%;\"\u003e\n\u003cp\u003e\u003cspan\u003eTwo ways 4-20mA output\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\" width=\"220\" style=\"width: 40.929401%;\"\u003e\u003cspan\u003e\u003cstrong\u003eCommunication\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" rowspan=\"1\" width=\"97\" style=\"width: 57.829181%;\"\u003e\u003cspan\u003eRS485 Modbus\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"220\" style=\"width: 40.929401%;\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eRelay\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\" width=\"97\" style=\"width: 57.829181%;\"\u003e\n\u003cp\u003e\u003cspan\u003eTwo relays: 5A\/250V AC, 5A\/30V DC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"220\" style=\"width: 40.929401%;\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eTemperature.Comp\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\" width=\"97\" style=\"width: 57.829181%;\"\u003e\n\u003cp\u003e\u003cspan\u003ePT1000 \/ NTC10K\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\" width=\"79\" style=\"width: 40.929401%;\"\u003e\u003cstrong\u003eDimension\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" rowspan=\"1\" width=\"97\" style=\"width: 57.829181%;\"\u003e\u003cspan\u003e144×144×104mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\" width=\"79\" style=\"width: 40.929401%;\"\u003e\u003cstrong\u003eHole size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" rowspan=\"1\" width=\"97\" style=\"width: 57.829181%;\"\u003e138*138mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"220\" style=\"width: 40.929401%;\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProtection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\" width=\"97\" style=\"width: 57.829181%; text-align: left;\"\u003e\u003cspan\u003eIP65\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"220\" style=\"width: 40.929401%;\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eData Logger\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\" rowspan=\"1\" width=\"97\" style=\"width: 57.829181%;\"\u003e\u003cspan\u003e1,000 times\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"220\" style=\"width: 40.929401%;\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eLanguage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\" width=\"97\" style=\"width: 57.829181%;\"\u003e\n\u003cp\u003e\u003cspan\u003eEnglish \/ 简体中文\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"220\" style=\"width: 40.929401%;\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eInstallation\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\" width=\"97\" style=\"width: 57.829181%;\"\u003e\n\u003cp\u003e\u003cspan\u003ePanel \/ Wall \/ Pipe mounted\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable style=\"height: 245px;\" class=\"MsoNormalTable\" border=\"0\" cellspacing=\"0\" cellpadding=\"0\" width=\"715\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 35px;\"\u003e\n\u003ctd style=\"height: 35px;\" width=\"155\" nowrap\u003e\n\u003cp style=\"text-align: left;\" class=\"MsoNormal\" align=\"center\"\u003e\u003cb\u003e\u003cspan\u003eProbe\u003c\/span\u003e\u003c\/b\u003e\u003cb\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"112\" nowrap\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cb\u003e\u003cspan\u003e870003-ICE-01\u003c\/span\u003e\u003c\/b\u003e\u003cb\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"112\" nowrap\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cb\u003e\u003cspan\u003e870003-ICE-02\u003c\/span\u003e\u003c\/b\u003e\u003cb\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"112\" nowrap\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cb\u003e\u003cspan\u003e870003-ICE-03\u003c\/span\u003e\u003c\/b\u003e\u003cb\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"112\" nowrap\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cb\u003e\u003cspan\u003e870003-ICE-04\u003c\/span\u003e\u003c\/b\u003e\u003cb\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"112\" nowrap\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cb\u003e\u003cspan\u003e870003-ICE-05\u003c\/span\u003e\u003c\/b\u003e\u003cb\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35px;\"\u003e\n\u003ctd style=\"height: 35px;\" width=\"155\" nowrap\u003e\n\u003cp style=\"text-align: left;\" class=\"MsoNormal\" align=\"center\"\u003e\u003cb\u003e\u003cspan\u003eCC\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"112\" nowrap\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e0.01\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"112\" nowrap\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e0.1\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"112\" nowrap\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e1.0\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"112\" nowrap\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e10\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"112\" nowrap\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e30\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35px;\"\u003e\n\u003ctd style=\"height: 35px;\" width=\"155\" nowrap\u003e\n\u003cp style=\"text-align: left;\" class=\"MsoNormal\" align=\"center\"\u003e\u003cb\u003e\u003cspan\u003eEC Range\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"112\" nowrap\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e0-2μS\/cm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"112\" nowrap\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e0-200μS\/cm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"112\" nowrap\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e0-2000μS\/cm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"112\" nowrap\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e0-20000μS\/cm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"112\" nowrap\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e30-600mS\/cm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35px;\"\u003e\n\u003ctd style=\"height: 35px;\" width=\"155\" nowrap\u003e\n\u003cp style=\"text-align: left;\" class=\"MsoNormal\" align=\"center\"\u003e\u003cb\u003e\u003cspan\u003eTemp Range\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"112\" nowrap\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e0.0-100.0°C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"112\" nowrap\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e0.0-100.0°C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"112\" nowrap\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e0.0-100.0°C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"112\" nowrap\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e0.0-100.0°C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"112\" nowrap\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e0.0-100.0°C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35px;\"\u003e\n\u003ctd style=\"height: 35px;\" width=\"155\" nowrap\u003e\n\u003cp style=\"text-align: left;\" class=\"MsoNormal\" align=\"center\"\u003e\u003cb\u003e\u003cspan\u003eAccuracy\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"560\" nowrap colspan=\"5\"\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e2%, ±0.5°C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35px;\"\u003e\n\u003ctd style=\"height: 35px;\" width=\"155\" nowrap\u003e\n\u003cp style=\"text-align: left;\" class=\"MsoNormal\" align=\"center\"\u003e\u003cb\u003e\u003cspan\u003eWithstand pressure\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"560\" nowrap colspan=\"5\"\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e0.4MPa\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35px;\"\u003e\n\u003ctd style=\"height: 35px;\" width=\"155\" nowrap\u003e\n\u003cp style=\"text-align: left;\" class=\"MsoNormal\" align=\"center\"\u003e\u003cb\u003e\u003cspan\u003eWaterproof Level\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"560\" nowrap colspan=\"5\"\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003eIP68\/NEMA6P\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eDownloads\u003c\/h4\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cstrong\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/860031-33-i.pdf\" target=\"_blank\"\u003e \u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/870003_Conductivity_Meter_Manual.pdf\" title=\"Inline Conductivity Meter - Users Manual\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg alt=\"PDF\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/pdf-icon-63x63_480x480.png\" style=\"float: left;\"\u003e\u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/860031-33-i.pdf\" target=\"_blank\"\u003e\u003cbr\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/870003_Conductivity_Meter_Manual.pdf\" title=\"Inline Conductivity Meter - Users Manual\"\u003eInstruction Manual\u003c\/a\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Sper Scientific","offers":[{"title":"Default Title","offer_id":46246435225824,"sku":"870003","price":722.98,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/industrial-conductivity-tds-salinity-resistivity-meter-870003-600932.jpg?v=1752691869"},{"product_id":"industrial-dissolved-oxygen-meter","title":"Online Industrial Dissolved Oxygen Meter","description":"\u003ch1\u003eInline Dissolved Oxygen Analyzer is designed for continuous, real-time DO monitoring across a wide range of industrial processes.\u003c\/h1\u003e\n\u003cp\u003eBuilt with a rugged yet straightforward design, the industrial dissolved oxygen probes deliver precise measurements in any process condition. Ideal for industries like pharmaceuticals, food and beverage, chemicals, power, microelectronics and clean water applications, this system ensures reliable dissolved oxygen monitoring.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eEfficient and easy-to-service dissolved oxygen measurement\u003c\/li\u003e\n\u003cli\u003eMeasures dissolved oxygen levels from ppb to ppm\u003c\/li\u003e\n\u003cli\u003eFast response time, even at ppb levels\u003c\/li\u003e\n\u003cli\u003eDurable, hygienic design for continuous online monitoring\u003c\/li\u003e\n\u003cli\u003eUser-friendly operation with an intuitive interface\u003c\/li\u003e\n\u003cli\u003eLower overall cost per measurement point\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003eOrdering Notes: \u003cbr\u003e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003e1. ALL SPER ONLINE WATER QUALITY METERS AND SENSORS ARE SOLD SEPARATELY - Please be sure to add the appropriate sensor (listed above) when purchasing your meter - ONE METER AND SENSOR are required for a complete system. \u003c\/span\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003e\u003cspan\u003e\u003cspan style=\"color: #ff2a00;\"\u003e2. All Inline Water Quality Meters and Sensors ship direct from the factory. Please allow 10-15 business days for shipping and \u003cspan style=\"caret-color: rgb(255, 42, 0);\"\u003ehandling\u003c\/span\u003e. \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable data-sort=\"sortDisabled\" class=\"table table-bordered table-hover\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd width=\"220\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"257\" colspan=\"2\" rowspan=\"1\"\u003e\n\u003cp\u003e\u003cstrong\u003eSper #870007 Dissolved Oxygen Meter\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"220\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eMeasurement\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"272\" colspan=\"2\" rowspan=\"1\"\u003e\u003cspan\u003eDissolved Oxygen, Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"220\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eDO Range\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"middle\" align=\"center\" width=\"257\" colspan=\"2\" rowspan=\"1\"\u003e\n\u003cp\u003e0.00~20.00 ug\/L \u003c\/p\u003e\n\u003cp\u003e0.00mg\/L~20.00 mg\/L \u003c\/p\u003e\n\u003cp\u003e0.00%~200.00 % \u003c\/p\u003e\n\u003cp\u003e-10.0℃~130.0℃ \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"220\" colspan=\"1\" rowspan=\"1\"\u003e\u003cspan\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd width=\"257\" colspan=\"2\" rowspan=\"1\"\u003e\u003cspan\u003e1%,  ±0.2℃\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"220\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eHousing Material\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"257\" colspan=\"2\"\u003e\n\u003cp\u003e\u003cspan\u003eABS Flame retardant: V0\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"220\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003ePower\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"257\" colspan=\"2\"\u003e\n\u003cp\u003e\u003cspan\u003e90 – 260V AC 50\/60Hz\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"220\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eConsumption\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"257\" colspan=\"2\"\u003e\n\u003cp\u003e\u003cspan\u003e4W\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"220\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOutput\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"257\" colspan=\"2\"\u003e\n\u003cp\u003e\u003cspan\u003eTwo ways 4-20mA output\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"220\" rowspan=\"1\" colspan=\"1\"\u003e\u003cspan\u003e\u003cstrong\u003eCommunication\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd width=\"257\" rowspan=\"1\" colspan=\"2\"\u003e\u003cspan\u003eRS485 Modbus\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"220\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eRelay\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"257\" colspan=\"2\"\u003e\n\u003cp\u003e\u003cspan\u003eTwo relays, 5A\/250V AC, 5A\/30V DC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"220\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eTemperature.Comp\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"257\" colspan=\"2\"\u003e\n\u003cp\u003e\u003cspan\u003ePT1000 \/ NTC10K \/ 22K\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"79\" rowspan=\"1\" colspan=\"1\"\u003e\u003cstrong\u003eDimension\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"257\" rowspan=\"1\" colspan=\"2\"\u003e\u003cspan\u003e144×144×104mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"79\" rowspan=\"1\" colspan=\"1\"\u003e\u003cstrong\u003eHole size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"257\" rowspan=\"1\" colspan=\"2\"\u003e138*138mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"220\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProtection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"257\" colspan=\"2\"\u003e\u003cspan\u003eIP65\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"220\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eLanguage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"257\" colspan=\"2\"\u003e\n\u003cp\u003e\u003cspan\u003eEnglish \/ 简体中文\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"220\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eInstallation\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"257\" colspan=\"2\"\u003e\n\u003cp\u003e\u003cspan\u003ePanel \/ Wall \/ Pipe mounted\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4\u003eDownloads\u003c\/h4\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cstrong\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/860031-33-i.pdf?v=1598908093\" target=\"_blank\"\u003e \u003c\/a\u003e\u003ca rel=\"noopener\" title=\"Inline Industrial Dissolved Oxygen Sensor - Users Manual\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/870007_Industrial_DO_Meter_Manual.pdf\" target=\"_blank\"\u003e\u003cimg style=\"float: left;\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/pdf-icon-63x63_480x480.png?v=1598991821\" alt=\"PDF\"\u003e \u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/860031-33-i.pdf?v=1598908093\" target=\"_blank\"\u003e\u003cbr\u003e\u003c\/a\u003e\u003ca rel=\"noopener\" title=\"Inline Industrial Dissolved Oxygen Sensor - Users Manual\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/870007_Industrial_DO_Meter_Manual.pdf\" target=\"_blank\"\u003eInstruction Manual\u003c\/a\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cstrong\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cstrong\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cstrong\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e","brand":"Sper Scientific","offers":[{"title":"Default Title","offer_id":46246435455200,"sku":"870007","price":825.35,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/inline-digital-optical-dissolved-oxygen-meter-870006-203770.jpg?v=1752691908"},{"product_id":"high-temperature-dissolved-oxygen-sensor","title":"Online High Temperature Dissolved Oxygen Sensor","description":"\u003ch1\u003e The Online High Temperature Dissolved Oxygen Sensor is designed to withstand steam sterilization at temperatures up to 130°C, featuring an auto-balance pressure system for reliable dissolved oxygen (DO) measurements in both liquids and gases. \u003c\/h1\u003e\n\u003cp\u003eIdeal for small microbial culture reactors, this sensor enables real-time monitoring of dissolved oxygen levels and is also suited for environmental monitoring, wastewater treatment, and aquaculture applications.\u003c\/p\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cspan\u003eMeasuring dissolved oxygen in water and treatment to maintain proper DO levels, are crucial functions in a variety of water treatment applications. While dissolved oxygen is necessary to support life and treatment processes, it can also be detrimental, causing oxidation that damages equipment and compromises product. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe DO concentration determines the quality of source water. Without enough DO, water turns foul and unhealthy, affecting the quality of the environment, drinking water and other products.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAbout Dissolved Oxygen\u003cbr\u003e\u003c\/strong\u003e Dissolved oxygen (DO) measures the amount of oxygen gas present in water, an essential indicator of water health. Water bodies that support life require adequate dissolved oxygen levels. DO enters water through:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDirect absorption from the atmosphere\u003c\/li\u003e\n\u003cli\u003eRapid water movement from winds, waves, currents, or mechanical aeration\u003c\/li\u003e\n\u003cli\u003ePhotosynthesis from aquatic plants as a natural by-product\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Temperature Electrode\u003c\/strong\u003e: High-temperature fermentation electrode, utilizing the polarographic principle.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Quality Membrane\u003c\/strong\u003e: Equipped with imported, high-quality breathable membrane heads.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDurable Construction\u003c\/strong\u003e: Steel gauze electrode membrane paired with silicone rubber construction.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat-resistant Design:\u003c\/strong\u003e Ensures stability and performance under high-temperature conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Included\u003c\/strong\u003e: Includes a 5 meter VP cable.\u003cmeta charset=\"utf-8\"\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003e\u003cbr\u003eOrdering Notes: \u003cbr\u003e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003e1. All Sper Online \u003ca title=\"Inline Water Quality Monitoring\" href=\"https:\/\/sperdirect.com\/collections\/inline-water-quality-monitors-sensors\"\u003eWater Quality Meters and Sensors\u003c\/a\u003e are sold separately - one of each is required for a complete system. \u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003e\u003cspan\u003e\u003cspan style=\"color: #ff2a00;\"\u003e2. All Online Water Quality Meters and Sensors ship direct from the factory. Please allow 10-15 business days for shipping and \u003cspan style=\"caret-color: rgb(255, 42, 0);\"\u003ehandling\u003c\/span\u003e. \u003c\/span\u003e\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003cdiv\u003e\n\u003cmeta charset=\"UTF-8\"\u003e\n\u003cdiv id=\"module-qQpu1lZr9T4j0001\"\u003e\n\u003cdiv id=\"grid-IeBuVP7aDW0c0000\" class=\"ce-d-flex ce-flex-wrap container\"\u003e\n\u003cdiv class=\"ce-col-12 ce-col-md-12 ce-col-xl-12\" id=\"cell-1NGiyHcFjgB00000\"\u003e\n\u003cdiv type=\"text\" id=\"unit-ZhND0q2lsXCc0000\"\u003e\n\u003cdiv class=\"ce-text_item\"\u003e\n\u003cdiv class=\"ce-text\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eAL SPECIFICATIONS\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"module-03bvnwB1yamN0002\"\u003e\n\u003cdiv id=\"grid-qZ10PFNx4Esy0000\" class=\"ce-d-flex ce-flex-wrap container\"\u003e\n\u003cdiv class=\"ce-col-12 ce-col-md-12 ce-col-xl-12\" id=\"cell-TvWZ6V7lwNzo0000\"\u003e\n\u003cdiv type=\"text\" id=\"unit-YaWJUHXsfNBR0000\"\u003e\n\u003cdiv class=\"ce-text_item\"\u003e\n\u003cdiv class=\"ce-text\"\u003e\n\u003cdiv class=\"table-responsive\"\u003e\n\u003cdiv class=\"table-responsive\"\u003e\n\u003ctable class=\"table table-bordered table-hover\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003e870007-HDO\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eParameter measurement\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eDissolved Oxygen, Temperature\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eMeasure range\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eDissolved Oxygen: (0~20.0)mg\/L,0~100ug\/L\u003c\/p\u003e\n\u003cp\u003eTemperature: 0~130.0℃\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eAccuracy\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eDissolved Oxygen: ±0.1ppb\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eMaterial\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eSS316L\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003ePermeable membrane\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eFluorine plastic, silicone, stainless steel wire mesh composite membrane.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eCathode\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003ePlatinum wire\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eAnode\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eSilver\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eTemperature compensation\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003ePT1000\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eThe response current in the air\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eAbout 60nA\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eThe response current in a nitrogen atmosphere\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eLess than one percent response current of response in air\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eElectrode respo\u003c\/span\u003e\u003c\/strong\u003e\u003cstrong\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003cstrong\u003e\u003cspan\u003ense time\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eAbout 60 seconds (up 95% response)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\u003cstrong\u003eElectrode Response Stability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eA constant oxygen partial pressure at a constant temperature environment, response current drift less than 3% per week\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\u003cstrong\u003eLiquid mixing flow to the electrode response\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e3% or less (in water at room temperature)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\u003cstrong\u003eElectrode Response Temperature Coefficient\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e3% (greenhouse)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\u003cstrong\u003eElectrode diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e12 mm, 25 mm optional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\u003cstrong\u003eElectrode insertion length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e120, 225, 325mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"module-i4Lyprle9A2N0003\"\u003e\n\u003cdiv id=\"grid-U5MYWljn6PhE0000\" class=\"ce-d-flex ce-flex-wrap container\"\u003e\n\u003cdiv class=\"ce-col-12 ce-col-md-12 ce-col-xl-12\" id=\"cell-TNL4JmRklvKr0000\"\u003e\n\u003cdiv type=\"text\" id=\"unit-DbkBArLdqHS50000\"\u003e\n\u003cdiv class=\"ce-text_item\"\u003e\n\u003cdiv class=\"ce-text\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"module-03bvnwB1yamN0002\"\u003e\n\u003cdiv id=\"grid-qZ10PFNx4Esy0000\" class=\"ce-d-flex ce-flex-wrap container\"\u003e\n\u003cdiv class=\"ce-col-12 ce-col-md-12 ce-col-xl-12\" id=\"cell-TvWZ6V7lwNzo0000\"\u003e\n\u003cdiv type=\"text\" id=\"unit-YaWJUHXsfNBR0000\"\u003e\n\u003cdiv class=\"ce-text_item\"\u003e\n\u003cdiv class=\"ce-text\"\u003e\n\u003cdiv class=\"table-responsive\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"module-i4Lyprle9A2N0003\"\u003e\n\u003cdiv id=\"grid-U5MYWljn6PhE0000\" class=\"ce-d-flex ce-flex-wrap container\"\u003e\n\u003cdiv class=\"ce-col-12 ce-col-md-12 ce-col-xl-12\" id=\"cell-TNL4JmRklvKr0000\"\u003e\n\u003cdiv type=\"text\" id=\"unit-DbkBArLdqHS50000\"\u003e\n\u003cdiv class=\"ce-text_item\"\u003e\n\u003cdiv class=\"ce-text\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4\u003eDownloads\u003c\/h4\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cstrong\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/860031-33-i.pdf?v=1598908093\" target=\"_blank\"\u003e \u003c\/a\u003e\u003ca title=\"Inline Hight Temp Dissolved Oxygen Sensor - Users Manual\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/High_Temp_Dissolved_Oxygen_Sensor_User_Manual.pdf\"\u003e\u003cimg alt=\"PDF\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/pdf-icon-63x63_480x480.png?v=1598991821\" style=\"float: left;\"\u003e\u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/860031-33-i.pdf?v=1598908093\" target=\"_blank\"\u003e\u003cbr\u003e\u003c\/a\u003e\u003ca rel=\"noopener\" title=\"Inline High Temp Dissolved Oxygen Sensor - Users Manual\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/High_Temp_Dissolved_Oxygen_Sensor_User_Manual.pdf\" target=\"_blank\"\u003eInstruction Manual\u003c\/a\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cstrong\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cstrong\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/860031-33-i.pdf?v=1598908093\" target=\"_blank\"\u003e \u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/Sper_VP_wiring_diagram.pdf\" title=\"Online Dissolved Oxygen Sensor - VP Wiring Diagram\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg alt=\"PDF\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/pdf-icon-63x63_480x480.png?v=1598991821\" style=\"float: left;\"\u003e\u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/860031-33-i.pdf?v=1598908093\" target=\"_blank\"\u003e\u003cbr\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/Sper_VP_wiring_diagram.pdf\" title=\"Online Dissolved Oxygen Sensor - VP Wiring Diagram\"\u003eVP Wiring Diagram\u003c\/a\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cstrong\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/div\u003e","brand":"Sper Scientific","offers":[{"title":"Select \u003e","offer_id":53640261140704,"sku":null,"price":1835.4,"currency_code":"USD","in_stock":true},{"title":"120mm | 870007-HDO\/VP6\/5M-120mm","offer_id":53640185413856,"sku":"870007-HDO\/VP6\/5M-120mm","price":1835.4,"currency_code":"USD","in_stock":true},{"title":"150mm | 870007-HDO\/VP6\/5M-150mm","offer_id":53640185446624,"sku":"870007-HDO\/VP6\/5M-150mm","price":2019.15,"currency_code":"USD","in_stock":true},{"title":"225mm | 870007-HDO-\/VP6\/5M-225mm","offer_id":53640185479392,"sku":"870007-HDO-\/VP6\/5M-225mm","price":2150.4,"currency_code":"USD","in_stock":true},{"title":"325mm | 870007-HDO-\/VP6\/5M-325mm","offer_id":53640185512160,"sku":"870007-HDO-\/VP6\/5M-325mm","price":2281.65,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/inline-high-temperature-dissolved-oxygen-sensor-870007-hdo-447273.jpg?v=1752691911"},{"product_id":"online-high-temperature-ph-sensor","title":"Online High Temperature pH Sensor","description":"\u003ch1\u003eThe Online High Temperature pH Sensor is built with premium materials and components, ensuring exceptional performance in even the most demanding industrial and process measurement applications.\u003c\/h1\u003e\n\u003cp\u003eThese advanced electrodes integrate both a glass or metal electrode and a reference electrode in a single shaft, with an optional Pt1000 temperature probe for added functionality.\u003c\/p\u003e\n\u003cp\u003eEngineered for durability, they feature an optimized PTFE annular diaphragm, which enables rapid response times and remains highly effective even in contaminated or oily\/fatty wastewater environments. The 870002-HPH series exemplifies cutting-edge technology in pH and redox measurement, with each electrode individually tested and accompanied by a calibration certificate for assured accuracy and reliability.\u003c\/p\u003e\n\u003cp\u003eManufactured in state-of-the-art facilities, these electrodes are built for consistent quality and compliance with modern standards. Made from physiologically safe, FDA-listed materials, they feature lead-free shaft glass and are fully RoHS-2 compliant. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated Design\u003c\/strong\u003e: Combines a glass or metal electrode and reference electrode in one shaft; optional Pt1000 temperature probe for added versatility.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptimized PTFE Diaphragm\u003c\/strong\u003e: Fast-responding PTFE annular diaphragm is resistant to contamination, ideal for use in oily or fatty wastewater environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrecision and Reliability\u003c\/strong\u003e: Each electrode is individually tested, ensuring accuracy and quality, and comes with a calibration certificate.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuality Manufacturing\u003c\/strong\u003e: Produced in modern facilities for consistent quality in every electrode.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety and Compliance\u003c\/strong\u003e: Made with physiologically safe, FDA-listed materials and lead-free shaft glass; RoHS-2 compliant for safe and environmentally friendly use.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Included\u003c\/strong\u003e: Includes a 5 meter VP cable.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003eOrdering Notes: \u003cbr\u003e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003e1. All Sper Online \u003ca href=\"https:\/\/sperdirect.com\/collections\/inline-water-quality-monitors-sensors\" title=\"Inline Water Quality Monitoring\"\u003eWater Quality Meters and Sensors\u003c\/a\u003e are sold separately - one of each is required for a complete system. \u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003e\u003cspan\u003e\u003cspan style=\"color: #ff2a00;\"\u003e2. All Online Water Quality Meters and Sensors ship direct from the factory. Please allow 10-15 business days for shipping and \u003cspan style=\"caret-color: rgb(255, 42, 0);\"\u003ehandling\u003c\/span\u003e. \u003c\/span\u003e\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable style=\"width: 100%; height: 176.34375px;\" cellspacing=\"0\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.59375px;\"\u003e\n\u003ctd style=\"width: 38.1387%; height: 19.59375px;\" width=\"210\" valign=\"top\"\u003e\u003cstrong\u003eParameters Measured\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8613%; height: 19.59375px;\" width=\"453\" valign=\"top\"\u003e\u003cstrong\u003epH, Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.59375px;\"\u003e\n\u003ctd style=\"width: 38.1387%; height: 19.59375px;\" width=\"210\" valign=\"top\"\u003e\u003cspan\u003eMeasuring Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8613%; height: 19.59375px;\" width=\"453\" valign=\"top\"\u003e\u003cspan\u003e0-14PH\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.59375px;\"\u003e\n\u003ctd style=\"width: 38.1387%; height: 19.59375px;\" width=\"210\" valign=\"top\"\u003e\u003cspan\u003eTemperature \u003cmeta charset=\"utf-8\"\u003eRange\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8613%; height: 19.59375px;\" width=\"453\" valign=\"top\"\u003e\u003cspan\u003e0-130℃\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.59375px;\"\u003e\n\u003ctd style=\"width: 38.1387%; height: 19.59375px;\" width=\"210\" valign=\"top\"\u003e\u003cspan\u003eAccuracy\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8613%; height: 19.59375px;\" width=\"453\" valign=\"top\"\u003e\u003cspan\u003e±0.1pH\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.59375px;\"\u003e\n\u003ctd style=\"width: 38.1387%; height: 19.59375px;\" width=\"210\" valign=\"top\"\u003e\u003cspan\u003eCompressive Strength\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8613%; height: 19.59375px;\" width=\"453\" valign=\"top\"\u003e\u003cspan\u003e0.6MPa\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.59375px;\"\u003e\n\u003ctd style=\"width: 38.1387%; height: 19.59375px;\" width=\"210\" valign=\"top\"\u003e\u003cspan\u003eTemperature Compensation\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8613%; height: 19.59375px;\" width=\"453\" valign=\"top\"\u003e\u003cspan\u003ePT1000, 10K etc\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.59375px;\"\u003e\n\u003ctd style=\"width: 38.1387%; height: 19.59375px;\" width=\"210\" valign=\"top\"\u003e\u003cspan\u003eSocket\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8613%; height: 19.59375px;\" width=\"453\" valign=\"top\"\u003e\u003cspan\u003eVP\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.59375px;\"\u003e\n\u003ctd style=\"width: 38.1387%; height: 19.59375px;\" width=\"210\" valign=\"top\"\u003e\u003cspan\u003eCable\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8613%; height: 19.59375px;\" width=\"453\" valign=\"top\"\u003e\u003cspan\u003eVP6\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.59375px;\"\u003e\n\u003ctd style=\"width: 38.1387%; height: 19.59375px;\" width=\"210\" valign=\"top\"\u003e\u003cspan\u003eDimensions \u0026amp; Insertion Length\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8613%; height: 19.59375px;\" width=\"453\" valign=\"top\"\u003e\u003cspan\u003e12x120mm, 150mm, 225mm and 325mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4\u003eDownloads\u003c\/h4\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cstrong\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/860031-33-i.pdf?v=1598908093\" target=\"_blank\"\u003e \u003c\/a\u003e\u003ca rel=\"noopener\" title=\"High Temperature pH Sensor  - Users Manual\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/High-Temperature_pH_Electrode.pdf\" target=\"_blank\"\u003e\u003cimg alt=\"PDF\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/pdf-icon-63x63_480x480.png?v=1598991821\" style=\"float: left;\"\u003e\u003c\/a\u003e\u003ca title=\"High Temperature pH Sensor  - Users Manual\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/High-Temperature_pH_Electrode.pdf\"\u003e\u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/860031-33-i.pdf?v=1598908093\" target=\"_blank\"\u003e\u003cbr\u003e\u003c\/a\u003e\u003ca rel=\"noopener\" title=\"High Temperature pH Sensor - Users Manual\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/High-Temperature_pH_Electrode.pdf\" target=\"_blank\"\u003eInstruction Manual\u003c\/a\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cmeta charset=\"utf-8\"\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cstrong\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cstrong\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/860031-33-i.pdf?v=1598908093\" target=\"_blank\"\u003e \u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/Sper_VP_wiring_diagram.pdf\" title=\"Online Dissolved Oxygen Sensor - VP Wiring Diagram\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg alt=\"PDF\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/pdf-icon-63x63_480x480.png?v=1598991821\" style=\"float: left;\"\u003e\u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/860031-33-i.pdf?v=1598908093\" target=\"_blank\"\u003e\u003cbr\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/Sper_VP_wiring_diagram.pdf\" title=\"Online Dissolved Oxygen Sensor - VP Wiring Diagram\"\u003eVP6 Wiring Diagram\u003c\/a\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cstrong\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e","brand":"Sper Scientific","offers":[{"title":"Select one \u003e","offer_id":53640689451232,"sku":null,"price":695.1,"currency_code":"USD","in_stock":true},{"title":"120mm | 870002-HPH\/VP6\/5M-120mm","offer_id":53640549204192,"sku":"870002-HPH\/VP6\/5M-120mm","price":915.6,"currency_code":"USD","in_stock":true},{"title":"150mm | 870002-HPH\/VP6\/5M-150mm","offer_id":53640549236960,"sku":"870002-HPH\/VP6\/5M-150mm","price":915.6,"currency_code":"USD","in_stock":true},{"title":"225mm | 870002-HPH\/VP6\/5M-225mm","offer_id":53640549269728,"sku":"870002-HPH\/VP6\/5M-225mm","price":1099.35,"currency_code":"USD","in_stock":true},{"title":"325mm | 870002-HPH\/VP6\/5M-325mm","offer_id":53640549302496,"sku":"870002-HPH\/VP6\/5M-325mm","price":1283.1,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/inline-high-temperature-ph-sensor-870002-hph-233536.jpg?v=1752691911"},{"product_id":"industrial-ph-orp-meter","title":"Online Industrial PH \u0026 ORP Meter","description":"\u003cp\u003e\u003cb\u003eOrdering Notes:\u003cbr\u003e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003e1. ALL SPER ONLINE WATER QUALITY METERS AND SENSORS ARE SOLD SEPARATELY - Please be sure to add the appropriate sensor (listed above) when purchasing your meter - ONE METER AND SENSOR are required for a complete system. \u003c\/span\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003e\u003cspan\u003e\u003cspan style=\"color: #ff2a00;\"\u003e2. All Inline Water Quality Meters and Sensors ship direct from the factory. Please allow 10-15 business days for shipping and \u003cspan style=\"caret-color: rgb(255, 42, 0);\"\u003ehandling\u003c\/span\u003e. \u003c\/span\u003e\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eOur Inline Industrial PH \u0026amp; ORP Meter offers stable and reliable operation designed to solve common issues faced by operators in water treatment and processing plants. \u003c\/h1\u003e\n\u003cp\u003eThese analyzers provide precise, continuous measurement, ensuring dependable water quality monitoring. Each pH and ORP meter is equipped with a transmitter and process adaptation, tailored to meet your specific pH control requirements. The meter delivers accurate readings in diverse environments, from ultra-pure water to bioreactor applications - even in challenging conditions like chemical production.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eStable, precise, continuous measurement of pH, ORP and temperature\u003c\/li\u003e\n\u003cli\u003eFlexible installation options: panel, wall, or pipe-mounted\u003c\/li\u003e\n\u003cli\u003eDual 4-20mA outputs and standard RS485 Modbus RTU communication\u003c\/li\u003e\n\u003cli\u003eHigh\/low control relay functionality\u003c\/li\u003e\n\u003cli\u003eLocal data logging for up to 1,000 entries\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications include industrial wastewater, drinking water monitoring, environmental monitoring, ultra-pure water, fermentation, food production and more.\u003cb\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable data-sort=\"sortDisabled\" class=\"table table-bordered table-hover\" style=\"width: 100%; height: 550px;\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"firstRow\" style=\"height: 35px;\"\u003e\n\u003ctd width=\"141\" style=\"width: 25.589837%; height: 35px;\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"166\" colspan=\"2\" rowspan=\"1\" style=\"width: 72.232305%; height: 35px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eSper Scientific #870002 \u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35px;\"\u003e\n\u003ctd width=\"141\" style=\"width: 25.589837%; height: 35px;\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eMeasurement\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"176\" colspan=\"2\" rowspan=\"1\" style=\"width: 72.232305%; height: 35px;\"\u003e\u003cspan\u003epH \/ ORP \/ Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 54px;\"\u003e\n\u003ctd width=\"141\" style=\"width: 25.589837%; height: 54px;\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"176\" colspan=\"2\" rowspan=\"1\" style=\"width: 72.232305%; height: 54px;\"\u003e\n\u003cp\u003e\u003cspan\u003e-2 ~16 pH, -2000 ~2000 mV, -30 ~130 ℃\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd width=\"141\" colspan=\"1\" rowspan=\"1\" style=\"width: 25.589837%; height: 19px;\"\u003e\u003cspan\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd width=\"176\" colspan=\"2\" rowspan=\"1\" style=\"width: 72.232305%; height: 19px;\"\u003e\u003cspan\u003e0.05pH,  ±0.2℃\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35px;\"\u003e\n\u003ctd width=\"141\" style=\"width: 25.589837%; height: 35px;\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eHousing Material\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"176\" colspan=\"2\" style=\"width: 72.232305%; height: 35px;\"\u003e\n\u003cp\u003e\u003cspan\u003eABS Flame retardant : V0\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35px;\"\u003e\n\u003ctd width=\"141\" style=\"width: 25.589837%; height: 35px;\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003ePower\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"176\" colspan=\"2\" style=\"width: 72.232305%; height: 35px;\"\u003e\n\u003cp\u003e\u003cspan\u003e90 – 260V AC 50\/60Hz\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35px;\"\u003e\n\u003ctd width=\"141\" style=\"width: 25.589837%; height: 35px;\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eConsumption\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"176\" colspan=\"2\" style=\"width: 72.232305%; height: 35px;\"\u003e\n\u003cp\u003e\u003cspan\u003e4W\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35px;\"\u003e\n\u003ctd width=\"141\" style=\"width: 25.589837%; height: 35px;\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOutput\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"176\" colspan=\"2\" style=\"width: 72.232305%; height: 35px;\"\u003e\n\u003cp\u003e\u003cspan\u003eTwo ways 4-20mA output\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd width=\"141\" rowspan=\"1\" colspan=\"1\" style=\"width: 25.589837%; height: 19px;\"\u003e\u003cspan\u003e\u003cstrong\u003eCommunication\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd width=\"176\" rowspan=\"1\" colspan=\"2\" style=\"width: 72.232305%; height: 19px;\"\u003e\u003cspan\u003eRS485 Modbus\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35px;\"\u003e\n\u003ctd width=\"141\" style=\"width: 25.589837%; height: 35px;\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eRelay\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"176\" colspan=\"2\" style=\"width: 72.232305%; height: 35px;\"\u003e\n\u003cp\u003e\u003cspan\u003eThree relays, 5A\/250V AC      5A\/30V DC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35px;\"\u003e\n\u003ctd width=\"141\" style=\"width: 25.589837%; height: 35px;\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eTemperature Comp\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"176\" colspan=\"2\" style=\"width: 72.232305%; height: 35px;\"\u003e\n\u003cp\u003e\u003cspan\u003ePT1000 \/ NTC10K\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd rowspan=\"1\" colspan=\"1\" style=\"width: 25.589837%; height: 19px;\"\u003e\u003cstrong\u003eDimension\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd rowspan=\"1\" colspan=\"2\" style=\"width: 72.232305%; height: 19px;\"\u003e\u003cspan\u003e144×144×104mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd rowspan=\"1\" colspan=\"1\" style=\"width: 25.589837%; height: 19px;\"\u003e\u003cstrong\u003eHole Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd rowspan=\"1\" colspan=\"2\" style=\"width: 72.232305%; height: 19px;\"\u003e138*138mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35px;\"\u003e\n\u003ctd width=\"141\" style=\"width: 25.589837%; height: 35px;\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProtection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"176\" colspan=\"2\" style=\"width: 72.232305%; height: 35px;\"\u003e\u003cspan\u003eIP65\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35px;\"\u003e\n\u003ctd width=\"141\" style=\"width: 25.589837%; height: 35px;\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eData logger\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"166\" rowspan=\"1\" colspan=\"2\" style=\"width: 72.232305%; height: 35px;\"\u003e\u003cspan\u003e1,000 times\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35px;\"\u003e\n\u003ctd width=\"141\" style=\"width: 25.589837%; height: 35px;\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eLanguage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"176\" colspan=\"2\" style=\"width: 72.232305%; height: 35px;\"\u003e\n\u003cp\u003e\u003cspan\u003eEnglish \/ 简体中文\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35px;\"\u003e\n\u003ctd width=\"141\" style=\"width: 25.589837%; height: 35px;\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eInstallation\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"176\" colspan=\"2\" style=\"width: 72.232305%; height: 35px;\"\u003e\n\u003cp\u003e\u003cspan\u003ePanel \/ Wall \/ Pipe mounted\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4\u003eDownloads\u003c\/h4\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cstrong\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/860031-33-i.pdf?v=1598908093\" target=\"_blank\"\u003e \u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/870002Industrial_pH_and_ORP_Manual.pdf\" title=\"Inline pH ORP Mater - Users Manual\"\u003e\u003cimg alt=\"PDF\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/pdf-icon-63x63_480x480.png?v=1598991821\" style=\"float: left;\"\u003e\u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/860031-33-i.pdf?v=1598908093\" target=\"_blank\"\u003e\u003cbr\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/870002Industrial_pH_and_ORP_Manual.pdf\" title=\"Inline pH ORP Mater - Users Manual\"\u003eInstruction Manual\u003c\/a\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Sper Scientific","offers":[{"title":"Default Title","offer_id":46246436176096,"sku":"870002","price":661.55,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/inline-industrial-ph-orp-meter-870002-793550.jpg?v=1752691886"},{"product_id":"online-acid-alkaline-concentration-meter","title":"Online Acid Alkaline Concentration Meter","description":"\u003cp\u003e\u003cb\u003eOrdering Notes:\u003cbr\u003e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003e1. ALL SPER ONLINE WATER QUALITY METERS AND SENSORS ARE SOLD SEPARATELY - Please be sure to add the appropriate sensor (listed above) when purchasing your meter - ONE METER AND SENSOR are required for a complete system. \u003c\/span\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003e\u003cspan\u003e\u003cspan style=\"color: #ff2a00;\"\u003e2. All Inline Water Quality Meters and Sensors ship direct from the factory. Please allow 10-15 business days for shipping and \u003cspan style=\"caret-color: rgb(255, 42, 0);\"\u003ehandling\u003c\/span\u003e.\u003c\/span\u003e\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eThe Sper Scientific Inline Acid Alkali Concentration Meter is a smart, inline digital device designed for accurate measurement of acid and alkali concentrations.\u003c\/h1\u003e\n\u003cp\u003e\u003cstrong\u003eMeasuring Parameters:\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eConductivity, NaCl, HCl, NHO3, NaOH, H2SO4, KOH, Temperature\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis meter features a digital inductive conductivity sensor capable of measuring a variety of solutions, including \u003cstrong\u003ehydrochloric acid, nitric acid, sodium chloride, sodium hydroxide, potassium hydroxide and both dilute and concentrated sulfuric acid\u003c\/strong\u003e. It's advanced digital acid-base concentration sensor ensures precise and reliable monitoring across different applications.\u003c\/p\u003e\n\u003cp\u003eThis concentration meter is ideal for industries such as thermal power generation, chemical manufacturing and ion exchange processes where high-purity water production is critical. It is particularly useful for monitoring acid-base salt concentrations during processes like regenerating liquid concentration or controlling the solution concentration in boiler pipe pickling. Designed for continuous, real-time monitoring, it delivers dependable performance in demanding industrial environments.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSmart, inline digital meter for accurate acid and alkali concentration measurement\u003c\/li\u003e\n\u003cli\u003eEquipped with a digital inductive conductivity sensor\u003c\/li\u003e\n\u003cli\u003eMeasures various solutions, including HCl, nitric acid, NaCl, NaOH, KOH, and sulfuric acid (dilute and concentrated)\u003c\/li\u003e\n\u003cli\u003eIdeal for thermal power, chemical industry, and ion exchange processes for high-purity water production\u003c\/li\u003e\n\u003cli\u003eEnsures precise control of acid-base salt concentration in continuous monitoring applications\u003c\/li\u003e\n\u003cli\u003eSuitable for regenerating liquid concentration and boiler pipe pickling solution configuration\u003c\/li\u003e\n\u003cli\u003eProvides real-time, continuous monitoring for reliable industrial performance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"ce-col-w-1 ce-col-w-md-1 ce-col-w-xl-1 ce-list_item\"\u003e\n\u003cdiv class=\"ce-list_item-inner ce-d-flex\"\u003e\n\u003cdiv class=\"ce-list_text\"\u003e\n\u003cdiv class=\"ce-list_title\"\u003e\n\u003cdiv class=\"ce-title\"\u003e\u003cstrong\u003eReal-Time Monitoring\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"ce-list_summary\"\u003e\n\u003cdiv class=\"ce-summary\"\u003eReal-time analysis and adjustments for precise monitoring of acid-base concentrations in industrial processes.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"ce-col-w-1 ce-col-w-md-1 ce-col-w-xl-1 ce-list_item\"\u003e\n\u003cdiv class=\"ce-list_item-inner ce-d-flex\"\u003e\n\u003cdiv class=\"ce-list_image\"\u003e\n\u003cdiv class=\"ce-image_item\"\u003e\n\u003cdiv class=\"ce-image_inner base-image__item\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"ce-list_text\"\u003e\n\u003cdiv class=\"ce-list_title\"\u003e\n\u003cdiv class=\"ce-title\"\u003e\u003cstrong\u003eOptimal Performance\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"ce-list_summary\"\u003e\n\u003cdiv class=\"ce-summary\"\u003eWith its advanced technology, this analyzer ensures optimal performance and efficiency in various industrial applications by providing accurate and reliable data.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"ce-col-w-1 ce-col-w-md-1 ce-col-w-xl-1 ce-list_item\"\u003e\n\u003cdiv class=\"ce-list_item-inner ce-d-flex\"\u003e\n\u003cdiv class=\"ce-list_image\"\u003e\n\u003cdiv class=\"ce-image_item\"\u003e\n\u003cdiv class=\"ce-image_inner base-image__item\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"ce-list_text\"\u003e\n\u003cdiv class=\"ce-list_title\"\u003e\n\u003cdiv class=\"ce-title\"\u003e\u003cstrong\u003eUser-Friendly Interface\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"ce-list_summary\"\u003e\n\u003cdiv class=\"ce-summary\"\u003eThe user-friendly interface makes it easy to operate and allows for seamless monitoring and control of acid-base concentrations in industrial processes.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"ce-col-w-1 ce-col-w-md-1 ce-col-w-xl-1 ce-list_item\"\u003e\n\u003cdiv class=\"ce-list_item-inner ce-d-flex\"\u003e\n\u003cdiv class=\"ce-list_image\"\u003e\n\u003cdiv class=\"ce-image_item\"\u003e\n\u003cdiv class=\"ce-image_inner base-image__item\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"ce-list_text\"\u003e\n\u003cdiv class=\"ce-list_title\"\u003e\n\u003cdiv class=\"ce-title\"\u003e\u003cstrong\u003eDurable Construction\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"ce-list_summary\"\u003e\n\u003cdiv class=\"ce-summary\"\u003eQuality construction ensures long-lasting reliability and stability, providing a dependable solution for continuous monitoring in industrial environments.\u003c\/div\u003e\n\u003cdiv class=\"ce-summary\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ch4 class=\"ce-summary\"\u003eSpecifications\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eMeter Specifications\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ctable style=\"border-collapse: collapse; width: 523pt;\" width=\"697\" cellspacing=\"0\" cellpadding=\"0\" border=\"0\"\u003e\n\u003ccolgroup\u003e \u003ccol style=\"mso-width-source: userset; mso-width-alt: 7296; width: 171pt;\" width=\"228\"\u003e \u003ccol style=\"mso-width-source: userset; mso-width-alt: 15018; width: 352pt;\" width=\"469\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 34.0pt;\" height=\"45\"\u003e\n\u003ctd style=\"height: 34.0pt; width: 171pt;\" width=\"228\" class=\"xl67\" height=\"45\"\u003e\u003cstrong\u003eProduct\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 352pt;\" width=\"469\" class=\"xl68\"\u003e\u003cstrong\u003eSodium Chloride (NaCl) Concentration Meter\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 17.0pt;\" height=\"23\"\u003e\n\u003ctd style=\"height: 17.0pt;\" height=\"23\"\u003eOutput Current\u003c\/td\u003e\n\u003ctd style=\"width: 352pt;\" width=\"469\" class=\"xl65\"\u003eTwo ways of 4-20mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 17.0pt;\" height=\"23\"\u003e\n\u003ctd style=\"height: 17.0pt;\" height=\"23\"\u003eCurrent Output Accuracy\u003c\/td\u003e\n\u003ctd style=\"width: 352pt;\" width=\"469\" class=\"xl65\"\u003e±1%FS,±0.5℃\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 17.0pt;\" height=\"23\"\u003e\n\u003ctd style=\"height: 17.0pt;\" height=\"23\"\u003eTemp. Measure Range\u003c\/td\u003e\n\u003ctd style=\"width: 352pt;\" width=\"469\" class=\"xl65\"\u003eConductivity 0~2000ms\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 17.0pt;\" height=\"23\"\u003e\n\u003ctd style=\"height: 17.0pt;\" height=\"23\"\u003ePower Requirements\u003c\/td\u003e\n\u003ctd style=\"width: 352pt;\" width=\"469\" class=\"xl65\"\u003e90 – 260V AC 50; 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 17.0pt;\" height=\"23\"\u003e\n\u003ctd style=\"height: 17.0pt;\" height=\"23\"\u003eCommunication Interface\u003c\/td\u003e\n\u003ctd style=\"width: 352pt;\" width=\"469\" class=\"xl65\"\u003eRS485\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 17.0pt;\" height=\"23\"\u003e\n\u003ctd style=\"height: 17.0pt;\" height=\"23\"\u003eOutput Signal\u003c\/td\u003e\n\u003ctd style=\"width: 352pt;\" width=\"469\" class=\"xl65\"\u003eTwo ways of 4-20mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 17.0pt;\" height=\"23\"\u003e\n\u003ctd style=\"height: 17.0pt;\" height=\"23\"\u003eSize\/Weight\u003c\/td\u003e\n\u003ctd style=\"width: 352pt;\" width=\"469\" class=\"xl65\"\u003e144×144×104mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 17.0pt;\" height=\"23\"\u003e\n\u003ctd style=\"height: 17.0pt;\" height=\"23\"\u003ePrinciple\u003c\/td\u003e\n\u003ctd style=\"width: 352pt;\" width=\"469\" class=\"xl65\"\u003eInductive Conductivity Sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 17.0pt;\" height=\"23\"\u003e\n\u003ctd style=\"height: 17.0pt;\" height=\"23\"\u003eFree Chlorine Range\u003c\/td\u003e\n\u003ctd style=\"width: 352pt;\" width=\"469\" class=\"xl65\"\u003eConductivity 0~2000ms\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 17.0pt;\" height=\"23\"\u003e\n\u003ctd style=\"height: 17.0pt;\" height=\"23\"\u003eProtection\u003c\/td\u003e\n\u003ctd style=\"width: 352pt;\" width=\"469\" class=\"xl65\"\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 17.0pt;\" height=\"23\"\u003e\n\u003ctd style=\"height: 17.0pt;\" height=\"23\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd style=\"width: 352pt;\" width=\"469\" class=\"xl65\"\u003e±1%FS,±0.5℃\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 17.0pt;\" height=\"23\"\u003e\n\u003ctd style=\"height: 17.0pt;\" height=\"23\"\u003eRelays\u003c\/td\u003e\n\u003ctd style=\"width: 352pt;\" width=\"469\" class=\"xl65\"\u003eTwo relays: 5A 250V AC; 5A 30V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 17.0pt;\" height=\"23\"\u003e\n\u003ctd style=\"height: 17.0pt;\" height=\"23\"\u003eCommunication\u003c\/td\u003e\n\u003ctd style=\"width: 352pt;\" width=\"469\" class=\"xl65\"\u003eRS485\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 17.0pt;\" height=\"23\"\u003e\n\u003ctd style=\"height: 17.0pt;\" height=\"23\"\u003ePower\u003c\/td\u003e\n\u003ctd style=\"width: 352pt;\" width=\"469\" class=\"xl65\"\u003e90 – 260V AC 50;60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan class=\"s1\"\u003eSensor Specifications \u003cbr\u003e(\u003ca href=\"https:\/\/sperdirect.com\/collections\/inline-water-quality-monitors-sensors\/products\/online-acid-alkaline-concentration-meter\" rel=\"noopener\" target=\"_blank\"\u003eInline Acid-Alkaline Sensors\u003c\/a\u003e sold separately)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"s1\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable class=\"MsoNormalTable\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\" width=\"750\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"163\" nowrap valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"147\" nowrap valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/sperdirect.com\/products\/industrial-inductive-acid-alkaline-sensor?variant=47008857587936\"\u003e870009-CS-PFA\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"146\" nowrap valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/sperdirect.com\/collections\/inline-water-quality-monitors-sensors\/products\/online-acid-alkaline-concentration-meter\"\u003e870009-CS\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"150\" nowrap valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/sperdirect.com\/products\/industrial-inductive-acid-alkaline-sensor?variant=54581983805664\" title=\"870009 CS2-PFA Sensor\"\u003e870009-CS2-PFA\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"144\" nowrap valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/sperdirect.com\/products\/industrial-inductive-acid-alkaline-sensor?variant=47009050231008\"\u003e870009-CS2\u003c\/a\u003e\u003ca href=\"https:\/\/sperdirect.com\/products\/industrial-inductive-acid-alkaline-sensor?variant=47009050231008\"\u003e\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"163\" nowrap valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003eElectrode body material\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"147\" nowrap valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003ePFA (Perfluoroalkoxy)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"146\" nowrap valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003ePEEK (Polypropelyne)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"150\" nowrap valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003ePFA (Perfluoroalkoxy)\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"144\" nowrap valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003ePEEK (Polypropelyne)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"163\" nowrap valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003eOperating temperature\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"293\" nowrap colspan=\"2\" valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e-20~80\u003c\/span\u003e\u003cspan\u003e℃\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"150\" nowrap valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e-30~125\u003c\/span\u003e\u003cspan\u003e℃\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"144\" nowrap valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e-30~150\u003c\/span\u003e\u003cspan\u003e℃\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"163\" nowrap valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003eMeasurement range\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"587\" colspan=\"4\" valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003e1mS\/cm ~ 2000mS\/cm\u003cbr\u003eHNO3: 0.00%~29.00%\/35.00%~96.00%(25C)\u003cbr\u003eH2SO4: 0.00%~29.00%\/30.00%~83.00%\/93.00%~99.00%(10°C)\u003cbr\u003eHCL: 0.00%~18.00%\/22.00%~39.00%(25°C) \u003cbr\u003eNaOH: :0.00%~14.00%\/18.00%~50.00%(25°C)\u003cbr\u003eNaCl:0.00%~26.00%(20°C)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"163\" valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003eAccuracy\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"587\" nowrap colspan=\"4\" valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e±2% of reading or  ± 1 mS\/cm, whichever is greater;  ±0.5\u003c\/span\u003e\u003cspan\u003e℃\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"163\" nowrap valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003eMaximum pressure (bar)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"147\" nowrap valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e16bar\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"146\" nowrap valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e21bar\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"150\" nowrap valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e16bar\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"144\" nowrap valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e21bar\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"163\" nowrap\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003eOutput\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"587\" nowrap colspan=\"4\"\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003eModbus RTU\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003eDownloads\u003c\/h4\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cstrong\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/860031-33-i.pdf?v=1598908093\" target=\"_blank\"\u003e \u003c\/a\u003e\u003ca rel=\"noopener\" title=\"Inline Acid Alkali Meter - Users Manual\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/870009_Acid_Alkali_analyzer_manual.pdf\" target=\"_blank\"\u003e\u003cimg style=\"float: left;\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/pdf-icon-63x63_480x480.png?v=1598991821\" alt=\"PDF\"\u003e \u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/860031-33-i.pdf?v=1598908093\" target=\"_blank\"\u003e\u003cbr\u003e\u003c\/a\u003e\u003ca rel=\"noopener\" title=\"Inline Acid Alkali Meter - Users Manual\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/870009_Acid_Alkali_analyzer_manual.pdf\" target=\"_blank\"\u003eInstruction Manual\u003c\/a\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"Sper Scientific","offers":[{"title":"Default Title","offer_id":46246436241632,"sku":"870009","price":1030.1,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/inline-acid-alkaline-concentration-meter-870009-354516.jpg?v=1752691908"},{"product_id":"wireless-module","title":"Wireless Module","description":"\u003cp class=\"p1\"\u003eGPRS gateway used by EMCP IOT cloud platform for MODBUS data automatic acquisition and transmission.\u003c\/p\u003e\n\u003ch4 class=\"p1\"\u003eDownloads\u003cspan style=\"font-size: 0.875rem;\"\u003e\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/WM-6099_DTU_Wireless_Module.pdf\" target=\"_blank\" title=\"WM-6099 Datasheet\" rel=\"noopener\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/pdf-icon-63x63_480x480.png?v=1598991821\" style=\"float: left;\" alt=\"PDF\"\u003e\u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/cr8-e.pdf?v=1704924058\" target=\"_blank\"\u003e\u003cbr\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/WM-6099_DTU_Wireless_Module.pdf\" target=\"_blank\" title=\"WM-6099 Product Datasheet\" rel=\"noopener\"\u003eProduct Datasheet\u003c\/a\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Sper Scientific","offers":[{"title":"Default Title","offer_id":47407009661152,"sku":"870012","price":1049.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/wireless-module-wm-6099-101565.jpg?v=1748137960"},{"product_id":"online-water-total-hardness-analyzer","title":"Online Total Water Hardness Analyzer","description":"\u003cdiv id=\"unit-jJRg30pax7IDugk\" type=\"text\"\u003e\n\u003cdiv class=\"ce-text_item\"\u003e\n\u003cdiv class=\"ce-text\"\u003e\n\u003ch1\u003eReal-Time Total Hardness Analysis\u003cbr\u003e\n\u003c\/h1\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"unit-dp0xU9KXb5h4sOF\" type=\"text\"\u003e\n\u003cdiv class=\"ce-text_item\"\u003e\n\u003cdiv class=\"ce-text\"\u003e\n\u003cp\u003eOnline Water Total Hardness Analyzer is an essential tool for monitoring water total hardness or carbonate hardness and total alkali through a fully automatic titration method. \u003c\/p\u003e\n\u003cdiv class=\"ce-col-w-1 ce-col-w-md-3 ce-col-w-xl-3 ce-list_item\"\u003e\n\u003cdiv class=\"ce-list_item-inner ce-d-flex\"\u003e\n\u003cdiv class=\"ce-list_text\"\u003e\n\u003cdiv class=\"ce-list_summary\"\u003e\n\u003cul\u003e\n\u003cli class=\"ce-summary\"\u003e\u003cspan\u003eReliable, exact and fully automatic analyzing hardness and alkali.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"ce-summary\"\u003eSimple commissioning with configuration assistant.\u003c\/li\u003e\n\u003cli class=\"ce-summary\"\u003e\u003cspan\u003eSelf calibrating and self monitoring in High measuring accuracy.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"ce-summary\"\u003e\u003cspan style=\"font-size: 0.875rem;\"\u003eEasy maintenance and cleaning.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"ce-summary\"\u003e\u003cspan style=\"font-size: 0.875rem;\"\u003eMinimal reagent and water consumption.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"ce-summary\"\u003e\u003cspan style=\"font-size: 0.875rem;\"\u003eMulti-colored and multi-lingual graphic display.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003eWith measurement ranges for hardness from 0.5-534ppm, and total alkali from 5.34-401ppm, this device provides accurate and repeatable results, making it ideal for quality control of water softening facilities and water blending facilities. The analyzer also offers programmable time intervals for analysis, flush time and output options such as potential-free relays, 4-20mA and CAN interface for added flexibility and convenience in monitoring water quality.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eHardness and Alkali analyzer is designed to monitor water total hardness and carbonate hardness, as well as total alkali, fully automatically through titration. The instrument is able to measure water total hardness or carbonate hardness and total alkali with high accuracy and repetition, making it ideal for recognizing hardness levels, quality control of water softening facilities, and monitoring of water blending facilities. This online water quality analyzer boasts an IP65 protection grade and is suitable for use in various industries such as agriculture, food and beverages, healthcare, pharmaceutical and more, making it an ideal choice for businesses seeking reliable water quality measurement and monitoring.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003c\/span\u003e\u003cstrong\u003ePrecise and Reliable Measurement\u003cbr\u003e\u003c\/strong\u003eOnline Water Total Hardness Analyzer offers precise and reliable measurement of total hardness in water, ensuring accurate data for effective water treatment.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong style=\"font-size: 0.875rem;\"\u003eContinuous Monitoring and Automatic Adjustments\u003cbr\u003e\u003c\/strong\u003e\u003cspan style=\"font-size: 0.875rem;\"\u003eWith its advanced technology, this Total Hardness Meter allows for continuous monitoring and automatic adjustments, guaranteeing optimal water quality at all times.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong style=\"font-size: 0.875rem;\"\u003eAccurate and Real-Time Data\u003cbr\u003e\u003c\/strong\u003e\u003cspan style=\"font-size: 0.875rem;\"\u003eThe Total Hardness Transmitter provides accurate and real-time data, allowing for quick and informed decision-making in water treatment processes.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong style=\"font-size: 0.875rem;\"\u003eSeamless Integration Into Existing Systems\u003cbr\u003e\u003c\/strong\u003e\u003cspan style=\"font-size: 0.875rem;\"\u003eThe Total Hardness Transmitter allows for seamless integration into existing water treatment systems, making it a valuable asset for any facility looking to improve water quality.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"unit-wSeat8IifqaSdy5\" class=\"ce-color-dark\" type=\"text\"\u003e\n\u003cdiv class=\"ce-text_item\"\u003e\n\u003cdiv class=\"ce-text\"\u003e\n\u003cdiv class=\"ce-col-w-1 ce-col-w-md-1 ce-col-w-xl-1 ce-list_item\"\u003e\n\u003cdiv class=\"ce-list_item-inner ce-d-flex\"\u003e\n\u003cdiv class=\"ce-list_text\"\u003e\n\u003cdiv class=\"ce-list_summary\"\u003e\n\u003cdiv class=\"ce-summary\"\u003e\n\u003cdiv class=\"ce-col-w-1 ce-col-w-md-3 ce-col-w-xl-3 ce-list_item\"\u003e\n\u003cdiv class=\"ce-list_item-inner ce-d-flex\"\u003e\n\u003cdiv class=\"ce-list_image\"\u003e\n\u003cdiv class=\"ce-image_item\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"ce-col-w-1 ce-col-w-md-3 ce-col-w-xl-3 ce-list_item\"\u003e\n\u003cdiv class=\"ce-list_item-inner ce-d-flex\"\u003e\n\u003cdiv class=\"ce-list_text\"\u003e\n\u003cdiv class=\"ce-list_summary\"\u003e\n\u003cdiv class=\"ce-summary\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"ce-summary\"\u003eSpecifications\u003c\/h4\u003e\n\u003cdiv id=\"module-jBfmb5MgcPWi0002\"\u003e\n\u003cdiv id=\"grid-bslQkHAZgSRr0000\" class=\"ce-d-flex ce-flex-wrap container\"\u003e\n\u003cdiv class=\"ce-col-12 ce-col-md-12 ce-col-xl-12\" id=\"cell-qNoMZnfyrthz0000\"\u003e\n\u003cdiv type=\"text\" id=\"unit-P6UEJCGQ38ju0000\"\u003e\n\u003cdiv class=\"ce-text_item\"\u003e\n\u003cdiv class=\"ce-text\"\u003e\n\u003cdiv class=\"table-responsive\"\u003e\n\u003ctable class=\"table table-bordered table-hover\" style=\"width: 100%; height: 804px;\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"firstRow\" style=\"height: 19px;\"\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\" style=\"width: 21.488804%; height: 19px;\"\u003e\u003cstrong\u003eProduct\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\" style=\"width: 74.883078%; height: 19px;\"\u003e\u003cstrong\u003eOnline Water Total Hardness Meter\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 38px;\"\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\" style=\"width: 21.488804%; height: 38px;\"\u003e\u003cstrong\u003eMeasurement method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\" style=\"width: 74.883078%; height: 38px;\"\u003eTitration method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 54px;\"\u003e\n\u003ctd style=\"width: 21.488804%; height: 54px;\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eWater inlet in general\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 74.883078%; height: 54px;\"\u003e\n\u003cp\u003e\u003cspan\u003eClear, colourless, free of solid particles, without gas bubbles\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 54px;\"\u003e\n\u003ctd style=\"width: 21.488804%; height: 54px;\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eMeasurement range\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 74.883078%; height: 54px;\"\u003e\n\u003cp\u003e\u003cspan\u003eTotal Hardness : 0.5-534ppm , total alkali:5.34~401ppm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35px;\"\u003e\n\u003ctd style=\"width: 21.488804%; height: 35px;\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eAccuracy\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 74.883078%; height: 35px;\"\u003e\n\u003cp\u003e\u003cspan\u003e+\/- 5% \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35px;\"\u003e\n\u003ctd style=\"width: 21.488804%; height: 35px;\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eRepetition\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 74.883078%; height: 35px;\"\u003e\n\u003cp\u003e\u003cspan\u003e±2.5%\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 54px;\"\u003e\n\u003ctd style=\"width: 21.488804%; height: 54px;\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eMeasuring water temp\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 74.883078%; height: 54px;\"\u003e\n\u003cp\u003e\u003cspan\u003e5-45℃\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 54px;\"\u003e\n\u003ctd style=\"width: 21.488804%; height: 54px;\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eWater inlet pressure\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 74.883078%; height: 54px;\"\u003e\n\u003cp\u003e\u003cspan\u003eca. 0.5 - 5 bar (max.) (Recommended 1 - 2 bar)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 140px;\"\u003e\n\u003ctd style=\"width: 21.488804%; height: 140px;\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eAnalysis start\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 74.883078%; height: 140px;\"\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eProgrammable time intervals (5 - 360 minutes)\u003c\/p\u003e\n\u003cp\u003eExternal signal\u003c\/p\u003e\n\u003cp\u003eProgrammable volume intervals\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35px;\"\u003e\n\u003ctd style=\"width: 21.488804%; height: 35px;\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eFlush time\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 74.883078%; height: 35px;\"\u003e\n\u003cp\u003e\u003cspan\u003eProgrammable flush time (15 - 1800 seconds)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 124px;\"\u003e\n\u003ctd style=\"width: 21.488804%; height: 124px;\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eSignal Outputs\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 74.883078%; height: 124px;\"\u003e\n\u003cp\u003e2 x potential-free Relays (max. 250 Vac \/ Vdc; 4A（as potential free output NC\/NO）)\u003c\/p\u003e\n\u003cp\u003e0\/4-20mA\u003c\/p\u003e\n\u003cp\u003eCAN interface\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35px;\"\u003e\n\u003ctd style=\"width: 21.488804%; height: 35px;\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003cstrong\u003e\u003cspan\u003ePower\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 74.883078%; height: 35px;\"\u003e\n\u003cp\u003e\u003cspan\u003e90 - 260 VAC (47 - 63Hz)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 54px;\"\u003e\n\u003ctd style=\"width: 21.488804%; height: 54px;\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003ePower consumption\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 74.883078%; height: 54px;\"\u003e\n\u003cp\u003e\u003cspan\u003e25 VA (in operation), 3.5 VA (stand by)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 38px;\"\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\" style=\"width: 21.488804%; height: 38px;\"\u003e\u003cstrong\u003eProtection grade\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\" style=\"width: 74.883078%; height: 38px;\"\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35px;\"\u003e\n\u003ctd style=\"width: 21.488804%; height: 35px;\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 74.883078%; height: 35px;\"\u003e\n\u003cp\u003e\u003cspan\u003e300x300x200 mm (WxHxD)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHardness Reagents \u0026amp; Measurement Ranges\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"table-responsive\"\u003e\n\u003ctable style=\"width: 100%; height: 247px;\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"firstRow\" style=\"height: 19px;\"\u003e\n\u003ctd width=\"142\" valign=\"top\" style=\"width: 22.866345%; height: 19px;\"\u003eReagent type\u003c\/td\u003e\n\u003ctd width=\"152\" valign=\"top\" style=\"width: 24.476651%; height: 19px;\"\u003e°dH\u003c\/td\u003e\n\u003ctd width=\"174\" valign=\"top\" style=\"width: 28.019324%; height: 19px;\"\u003e°F\u003c\/td\u003e\n\u003ctd width=\"176\" valign=\"top\" style=\"width: 28.341385%; height: 19px;\"\u003eppm CaCO3\u003c\/td\u003e\n\u003ctd width=\"194\" valign=\"top\" style=\"width: 31.239936%; height: 19px;\"\u003emmol\/l\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 38px;\"\u003e\n\u003ctd width=\"142\" valign=\"top\" style=\"width: 22.866345%; height: 38px;\"\u003eTH5001\u003c\/td\u003e\n\u003ctd width=\"152\" valign=\"top\" style=\"width: 24.476651%; height: 38px;\"\u003e0.03-0.3\u003c\/td\u003e\n\u003ctd width=\"174\" valign=\"top\" style=\"width: 28.019324%; height: 38px;\"\u003e0.053-0.534\u003c\/td\u003e\n\u003ctd width=\"176\" valign=\"top\" style=\"width: 28.341385%; height: 38px;\"\u003e0.534-5.340 \u003c\/td\u003e\n\u003ctd width=\"194\" valign=\"top\" style=\"width: 31.239936%; height: 38px;\"\u003e0.005-0.053\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 38px;\"\u003e\n\u003ctd width=\"142\" valign=\"top\" style=\"width: 22.866345%; height: 38px;\"\u003eTH5003\u003c\/td\u003e\n\u003ctd width=\"152\" valign=\"top\" style=\"width: 24.476651%; height: 38px;\"\u003e0.09-0.9\u003c\/td\u003e\n\u003ctd width=\"174\" valign=\"top\" style=\"width: 28.019324%; height: 38px;\"\u003e0.160-1.602\u003c\/td\u003e\n\u003ctd width=\"176\" valign=\"top\" style=\"width: 28.341385%; height: 38px;\"\u003e1.602-16.02\u003c\/td\u003e\n\u003ctd width=\"194\" valign=\"top\" style=\"width: 31.239936%; height: 38px;\"\u003e0.016-0.160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 38px;\"\u003e\n\u003ctd width=\"142\" valign=\"top\" style=\"width: 22.866345%; height: 38px;\"\u003eTH5010\u003c\/td\u003e\n\u003ctd width=\"152\" valign=\"top\" style=\"width: 24.476651%; height: 38px;\"\u003e0.3-3.0\u003c\/td\u003e\n\u003ctd width=\"174\" valign=\"top\" style=\"width: 28.019324%; height: 38px;\"\u003e0.534-5.340\u003c\/td\u003e\n\u003ctd width=\"176\" valign=\"top\" style=\"width: 28.341385%; height: 38px;\"\u003e5.340-53.40\u003c\/td\u003e\n\u003ctd width=\"194\" valign=\"top\" style=\"width: 31.239936%; height: 38px;\"\u003e0.053-0.535\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 38px;\"\u003e\n\u003ctd width=\"142\" valign=\"top\" style=\"width: 22.866345%; height: 38px;\"\u003eTH5030\u003c\/td\u003e\n\u003ctd width=\"152\" valign=\"top\" style=\"width: 24.476651%; height: 38px;\"\u003e0.9-9.0\u003c\/td\u003e\n\u003ctd width=\"174\" valign=\"top\" style=\"width: 28.019324%; height: 38px;\"\u003e1.602-16.02\u003c\/td\u003e\n\u003ctd width=\"176\" valign=\"top\" style=\"width: 28.341385%; height: 38px;\"\u003e16.02-160.2\u003c\/td\u003e\n\u003ctd width=\"194\" valign=\"top\" style=\"width: 31.239936%; height: 38px;\"\u003e0.160-1.602\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 38px;\"\u003e\n\u003ctd width=\"142\" valign=\"top\" style=\"width: 22.866345%; height: 38px;\"\u003eTH5050\u003c\/td\u003e\n\u003ctd width=\"152\" valign=\"top\" style=\"width: 24.476651%; height: 38px;\"\u003e1.5-15\u003c\/td\u003e\n\u003ctd width=\"174\" valign=\"top\" style=\"width: 28.019324%; height: 38px;\"\u003e2.67-26.7\u003c\/td\u003e\n\u003ctd width=\"176\" valign=\"top\" style=\"width: 28.341385%; height: 38px;\"\u003e26.7-267.0\u003c\/td\u003e\n\u003ctd width=\"194\" valign=\"top\" style=\"width: 31.239936%; height: 38px;\"\u003e0.267-2.670\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 38px;\"\u003e\n\u003ctd width=\"142\" valign=\"top\" style=\"width: 22.866345%; height: 38px;\"\u003eTH5100\u003c\/td\u003e\n\u003ctd width=\"152\" valign=\"top\" style=\"width: 24.476651%; height: 38px;\"\u003e3.0-30\u003c\/td\u003e\n\u003ctd width=\"174\" valign=\"top\" style=\"width: 28.019324%; height: 38px;\"\u003e5.340-53.40\u003c\/td\u003e\n\u003ctd width=\"176\" valign=\"top\" style=\"width: 28.341385%; height: 38px;\"\u003e53.40-534.0\u003c\/td\u003e\n\u003ctd width=\"194\" valign=\"top\" style=\"width: 31.239936%; height: 38px;\"\u003e0.535-5.340\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAlkali Reagents \u0026amp; Measurement Ranges\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cdiv class=\"table-responsive\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd width=\"419\" valign=\"top\"\u003eReagents model\u003c\/td\u003e\n\u003ctd width=\"417\" valign=\"top\"\u003eMeasuring range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"419\" valign=\"top\"\u003eTC5010\u003c\/td\u003e\n\u003ctd width=\"417\" valign=\"top\"\u003e5.34~134 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"419\" valign=\"top\"\u003eTC5015\u003c\/td\u003e\n\u003ctd width=\"417\" valign=\"top\"\u003e8.01~205ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"419\" valign=\"top\"\u003eTC5020\u003c\/td\u003e\n\u003ctd width=\"417\" valign=\"top\"\u003e10.7~267ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"419\" valign=\"top\"\u003eTC5030\u003c\/td\u003e\n\u003ctd width=\"417\" valign=\"top\"\u003e16.0~401ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4\u003eDownloads\u003c\/h4\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cstrong\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/860031-33-i.pdf?v=1598908093\" target=\"_blank\"\u003e \u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/Online-Water-Hardness-Analyzer-Manual.pdf\" target=\"_blank\" title=\"Online Total Water Hardness Analyzer - Users Manual\" rel=\"noopener\"\u003e\u003cimg alt=\"PDF\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/pdf-icon-63x63_480x480.png?v=1598991821\" style=\"float: left;\"\u003e \u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/860031-33-i.pdf?v=1598908093\" target=\"_blank\"\u003e\u003cbr\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/Online-Water-Hardness-Analyzer-Manual.pdf\" target=\"_blank\" title=\"Online Total Water Hardness Users Manual\" rel=\"noopener\"\u003eInstruction Manual\u003c\/a\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Sper Scientific","offers":[{"title":"Default Title","offer_id":47596813287648,"sku":"870013","price":9087.8,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/online-water-total-hardness-analyzer-870013-3359228.jpg?v=1753329751"},{"product_id":"fermentation-ph-sensor-s8","title":"Fermentation PH Sensor - S8","description":"\u003ch1\u003eHigh Temperature pH Fermentation Sensor is designed for fermentation, pharmaceutical production and online monitoring of food and beverage processes.\u003c\/h1\u003e\n\u003cp\u003eA heat-resistant gel electrolyte and solid electrolyte double liquid junction support demanding process conditions and sterilization at 130°C.\u003c\/p\u003e\n\u003cp\u003eThe electrode requires no electrolyte refilling and minimal maintenance. An S8 connector and PG13.5 mounting thread support installation in compatible electrode assemblies, while optional lengths of 120, 150, 225 and 325 mm accommodate different process requirements. It is designed for use with a 316L stainless steel sheath and withstands pressure up to 0.4 MPa without back-pressure connection.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHeat-resistant gel and solid electrolyte double liquid junction\u003c\/li\u003e\n\u003cli\u003eSuitable for sterilization at 130°C\u003c\/li\u003e\n\u003cli\u003eNo electrolyte refilling required\u003c\/li\u003e\n\u003cli\u003eS8 connector and PG13.5 mounting thread\u003c\/li\u003e\n\u003cli\u003eAvailable in 120, 150, 225 and 325 mm lengths\u003c\/li\u003e\n\u003cli\u003eDesigned for use with a 316L stainless steel sheath\u003c\/li\u003e\n\u003cli\u003ePressure resistance up to 0.4 MPa without back-pressure connection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSuitable for biotechnology processes involving amino acids, blood products, insulin and interferon, as well as pharmaceutical production of antibiotics, vitamins and citric acid.\u003cbr\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eBrewing applications include mashing, boiling, fermentation, bottling, cold wort and deoxygenated water.\u003cbr\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eFood and beverage uses include online monitoring of MSG, soy sauce, dairy products, juice, yeast, sugar and drinking water.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring Range\u003c\/td\u003e\n\u003ctd\u003e0–14 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e0–130°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Pressure\u003c\/td\u003e\n\u003ctd\u003e6 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThread\u003c\/td\u003e\n\u003ctd\u003ePG13.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector\u003c\/td\u003e\n\u003ctd\u003eS8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Sper Scientific","offers":[{"title":"Select One \u003e","offer_id":67897414418656,"sku":null,"price":348.0,"currency_code":"USD","in_stock":true},{"title":"SSHPH100-S8 Fermentation pH sensor | 120mm length","offer_id":67897414451424,"sku":"SSHPH100-S8-120","price":348.0,"currency_code":"USD","in_stock":true},{"title":"SSHPH100-S8 Fermentation pH sensor | 150mm length","offer_id":67897414484192,"sku":"SSHPH100-S8-150","price":387.0,"currency_code":"USD","in_stock":true},{"title":"SSHPH100-S8 Fermentation pH sensor | 225mm length","offer_id":67897414516960,"sku":"SSHPH100-S8-225","price":398.0,"currency_code":"USD","in_stock":true},{"title":"SSHPH100-S8 Fermentation pH sensor | 325mm length","offer_id":67897414549728,"sku":"SSHPH100-S8-325","price":473.0,"currency_code":"USD","in_stock":true},{"title":"SSHPH100-S8 Fermentation pH sensor | 425mm length","offer_id":68761386352864,"sku":"SSHPH100-S8-425","price":512.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/fermentation-ph-sensor-s8-5347430.jpg?v=1791990913"},{"product_id":"sanitary-tri-clamp-conductivity-sensor","title":"Sanitary Tri-Clamp Conductivity Sensor","description":"\u003ch1\u003eThe Tri-Clamp Conductivity Sensor Series measures water conductivity across five configurations, with cell constants and probe lengths suited to different measurement ranges and installation requirements.\u003c\/h1\u003e\n\u003cp\u003eApplications include purified water systems, reverse osmosis, pharmaceutical processing, food production and industrial water monitoring.\u003c\/p\u003e\n\u003cp\u003eSelect K = 0.01 cm⁻¹ for measurements from 0 to 20 µS\/cm, K = 0.1 cm⁻¹ for 0 to 200 µS\/cm or K = 1.0 cm⁻¹ for 0 to 2,000 µS\/cm. Short and long versions are available for the K = 0.01 and K = 0.1 configurations, while the K = 1.0 configuration is offered in a short version.\u003c\/p\u003e\n\u003cp\u003eEach sensor features a stainless steel housing, a 50.5 mm Tri-Clamp flange and IP68 protection. All configurations have a specified temperature range of 0 to 120°C and pressure range of 0 to 4 bar. An NTC10K temperature sensor and 5 m signal cable are standard, with alternative temperature sensors and custom cable lengths available.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThree cell constants covering conductivity ranges up to 2,000 µS\/cm\u003c\/li\u003e\n\u003cli\u003eFive configurations with different probe lengths\u003c\/li\u003e\n\u003cli\u003eMeasurement accuracy of ±2% of full scale\u003c\/li\u003e\n\u003cli\u003eStainless steel housing with 50.5 mm Tri-Clamp flange\u003c\/li\u003e\n\u003cli\u003eNTC10K temperature sensor as standard\u003c\/li\u003e\n\u003cli\u003eOptional PT1000, PT100 or NTC2.252K temperature sensors\u003c\/li\u003e\n\u003cli\u003e5 m standard signal cable with customizable lengths\u003c\/li\u003e\n\u003cli\u003eIP68 protection rating\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProbe Options\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eK = 0.01 cm⁻¹: Short or long probe configuration\u003c\/li\u003e\n\u003cli\u003eK = 0.1 cm⁻¹: Short or long probe configuration\u003c\/li\u003e\n\u003cli\u003eK = 1.0 cm⁻¹: Short probe configuration\u003c\/li\u003e\n\u003cli\u003ePT1000, PT100 or NTC2.252K temperature sensor in place of the standard NTC10K\u003c\/li\u003e\n\u003cli\u003eCustom signal cable lengths\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eConfiguration\u003c\/th\u003e\n\u003cth style=\"text-align: left;\"\u003eCell Constant\u003c\/th\u003e\n\u003cth style=\"text-align: left;\"\u003eConductivity Range\u003c\/th\u003e\n\u003cth style=\"text-align: left;\"\u003eOverall Length\u003c\/th\u003e\n\u003cth style=\"text-align: left;\"\u003eProbe Length\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eK = 0.01 Short\u003c\/td\u003e\n\u003ctd\u003e0.01 cm⁻¹\u003c\/td\u003e\n\u003ctd\u003e0–20 µS\/cm\u003c\/td\u003e\n\u003ctd\u003e90 mm\u003c\/td\u003e\n\u003ctd\u003e60 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eK = 0.01 Long\u003c\/td\u003e\n\u003ctd\u003e0.01 cm⁻¹\u003c\/td\u003e\n\u003ctd\u003e0–20 µS\/cm\u003c\/td\u003e\n\u003ctd\u003e125 mm\u003c\/td\u003e\n\u003ctd\u003e95 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eK = 0.1 Short\u003c\/td\u003e\n\u003ctd\u003e0.1 cm⁻¹\u003c\/td\u003e\n\u003ctd\u003e0–200 µS\/cm\u003c\/td\u003e\n\u003ctd\u003e86 mm\u003c\/td\u003e\n\u003ctd\u003e51 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eK = 0.1 Long\u003c\/td\u003e\n\u003ctd\u003e0.1 cm⁻¹\u003c\/td\u003e\n\u003ctd\u003e0–200 µS\/cm\u003c\/td\u003e\n\u003ctd\u003e126 mm\u003c\/td\u003e\n\u003ctd\u003e96 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eK = 1.0 Short\u003c\/td\u003e\n\u003ctd\u003e1.0 cm⁻¹\u003c\/td\u003e\n\u003ctd\u003e0–2,000 µS\/cm\u003c\/td\u003e\n\u003ctd\u003e89 mm\u003c\/td\u003e\n\u003ctd\u003e54 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eShared Specifications\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; height: 372.282px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth scope=\"row\" style=\"text-align: left; width: 26.8746%; height: 19.5938px;\"\u003eResolution\u003c\/th\u003e\n\u003ctd style=\"width: 70.549%; height: 19.5938px;\"\u003e1 µS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth scope=\"row\" style=\"text-align: left; width: 26.8746%; height: 19.5938px;\"\u003eMeasurement Accuracy\u003c\/th\u003e\n\u003ctd style=\"width: 70.549%; height: 19.5938px;\"\u003e±2% FS (full scale)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth scope=\"row\" style=\"text-align: left; width: 26.8746%; height: 19.5938px;\"\u003eTemperature Range\u003c\/th\u003e\n\u003ctd style=\"width: 70.549%; height: 19.5938px;\"\u003e0–120°C (32–248°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth scope=\"row\" style=\"text-align: left; width: 26.8746%; height: 19.5938px;\"\u003ePressure Range\u003c\/th\u003e\n\u003ctd style=\"width: 70.549%; height: 19.5938px;\"\u003e0–4 bar (approximately 0–58 psi)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003cth scope=\"row\" style=\"text-align: left; width: 26.8746%; height: 39.1875px;\"\u003eStandard Temperature Sensor\u003c\/th\u003e\n\u003ctd style=\"width: 70.549%; height: 39.1875px;\"\u003eNTC10K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003cth scope=\"row\" style=\"text-align: left; width: 26.8746%; height: 39.1875px;\"\u003eOptional Temperature Sensors\u003c\/th\u003e\n\u003ctd style=\"width: 70.549%; height: 39.1875px;\"\u003ePT1000, PT100 or NTC2.252K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth scope=\"row\" style=\"text-align: left; width: 26.8746%; height: 19.5938px;\"\u003eHousing Material\u003c\/th\u003e\n\u003ctd style=\"width: 70.549%; height: 19.5938px;\"\u003eStainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth scope=\"row\" style=\"text-align: left; width: 26.8746%; height: 19.5938px;\"\u003eSignal Cable\u003c\/th\u003e\n\u003ctd style=\"width: 70.549%; height: 19.5938px;\"\u003e5 m (16.4 ft.) standard; custom lengths available\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth scope=\"row\" style=\"text-align: left; width: 26.8746%; height: 19.5938px;\"\u003eInstallation Type\u003c\/th\u003e\n\u003ctd style=\"width: 70.549%; height: 19.5938px;\"\u003eImmersion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth scope=\"row\" style=\"width: 26.8746%; height: 19.5938px;\"\u003eClamp\/Flange Diameter\u003c\/th\u003e\n\u003ctd style=\"width: 70.549%; height: 19.5938px;\"\u003e50.5 mm (1.99 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth scope=\"row\" style=\"width: 26.8746%; height: 19.5938px; text-align: left;\"\u003eUpper Body Diameter\u003c\/th\u003e\n\u003ctd style=\"width: 70.549%; height: 19.5938px;\"\u003e17 mm (0.67 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth scope=\"row\" style=\"width: 26.8746%; height: 19.5938px; text-align: left;\"\u003eProbe Diameter\u003c\/th\u003e\n\u003ctd style=\"width: 70.549%; height: 19.5938px;\"\u003e14 mm (0.55 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth scope=\"row\" style=\"width: 26.8746%; height: 19.5938px; text-align: left;\"\u003eFlange Section Length\u003c\/th\u003e\n\u003ctd style=\"width: 70.549%; height: 19.5938px;\"\u003e10 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003cth scope=\"row\" style=\"width: 26.8746%; height: 39.1875px; text-align: left;\"\u003eUpper Section Length\u003c\/th\u003e\n\u003ctd style=\"width: 70.549%; height: 39.1875px;\"\u003e20 mm for K = 0.01 Short, K = 0.01 Long and K = 0.1 Long; 25 mm for K = 0.1 Short and K = 1.0 Short\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth scope=\"row\" style=\"width: 26.8746%; height: 19.5938px; text-align: left;\"\u003eProtection Rating\u003c\/th\u003e\n\u003ctd style=\"width: 70.549%; height: 19.5938px;\"\u003eIP68\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth scope=\"row\" style=\"width: 26.8746%; height: 19.5938px; text-align: left;\"\u003eWarranty\u003c\/th\u003e\n\u003ctd style=\"width: 70.549%; height: 19.5938px;\"\u003e1 year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eFAQs\u003c\/h4\u003e\n\u003ch3\u003eWhich cell constant should I choose?\u003c\/h3\u003e\n\u003cp\u003eSelect a configuration that covers your expected conductivity range: K = 0.01 cm⁻¹ for 0–20 µS\/cm, K = 0.1 cm⁻¹ for 0–200 µS\/cm or K = 1.0 cm⁻¹ for 0–2,000 µS\/cm.\u003c\/p\u003e\n\u003ch3\u003eWhat is the difference between the short and long versions?\u003c\/h3\u003e\n\u003cp\u003eThe versions have different overall and probe lengths to accommodate installation requirements. The measurement range remains the same for versions with the same cell constant.\u003c\/p\u003e\n\u003ch3\u003eWhich temperature sensor is included?\u003c\/h3\u003e\n\u003cp\u003eNTC10K is standard. PT1000, PT100 and NTC2.252K are available as options. Confirm compatibility with the connected instrument before ordering.\u003c\/p\u003e\n\u003ch3\u003eCan the cable length be customized?\u003c\/h3\u003e\n\u003cp\u003eYes. The standard signal cable is 5 m long, with custom lengths available.\u003c\/p\u003e","brand":"Sper Scientific","offers":[{"title":"Select \u003e","offer_id":67950394114272,"sku":null,"price":290.0,"currency_code":"USD","in_stock":true},{"title":"Sanitary Conductivity Sensor K=0.01 - Short Type","offer_id":67950394147040,"sku":"SSHEC100-0.01-S","price":290.0,"currency_code":"USD","in_stock":true},{"title":"Sanitary Conductivity Sensor K=0.01 - Long Type","offer_id":67950394179808,"sku":"SSHEC100-0.01-L","price":290.0,"currency_code":"USD","in_stock":true},{"title":"Sanitary Conductivity Sensor K=0.1 - Short Type","offer_id":67950394212576,"sku":"SSHEC100-0.1-S","price":290.0,"currency_code":"USD","in_stock":true},{"title":"Sanitary Conductivity Sensor K=0.1 - Long Type","offer_id":67950394245344,"sku":"SSHEC100-0.1-S","price":290.0,"currency_code":"USD","in_stock":true},{"title":"Sanitary Conductivity Sensor K=1.0 - Short Type","offer_id":67950394278112,"sku":"SSHEC100-1.0-L","price":290.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/sanitary-tri-clamp-conductivity-sensor-3534364.jpg?v=1792184831"},{"product_id":"sper-scientific-ph-conductivity-dual-channel-online-analyzer","title":"Online Dual-Channel pH\/Conductivity Analyzer","description":"\u003ch1\u003eSper Scientific Online pH\/Conductivity Analyzer monitors one analog pH or ORP sensor and one analog conductivity sensor simultaneously.\u003c\/h1\u003e\n\u003cp\u003e\u003cstrong\u003eIt combines two measurement channels in a compact panel-mounted instrument for continuous water quality monitoring in industrial processes, water treatment and wastewater applications.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe pH\/ORP channel supports acidity or oxidation-reduction potential measurement, while the conductivity channel provides conductivity, TDS, salinity or resistivity readings. Temperature measurement and compensation support consistent process evaluation when used with compatible probes. Actual measurement range, process temperature limits and overall system performance depend on the sensors selected.\u003c\/p\u003e\n\u003cp\u003eA 3.1-inch backlit LCD displays process readings, while the front-panel buttons provide access to measurement and output settings. Two configurable 4–20 mA outputs and RS485 Modbus RTU communication support integration with PLCs and plant monitoring systems. Three relay outputs provide alarm and supported control functions.\u003c\/p\u003e\n\u003cp\u003eHistorical data records and trend curves help review process changes. Recording intervals can be set from 1–999 minutes, and stored data can be exported to a computer over USB. The ABS enclosure has an IP65 protection rating, with standard 100–240 VAC power and an optional 24 VDC configuration.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSimultaneous pH\/ORP and conductivity monitoring with compatible analog sensors\u003c\/li\u003e\n\u003cli\u003eConductivity-channel functions include EC, TDS, salinity and resistivity\u003c\/li\u003e\n\u003cli\u003eTemperature compensation with multiple supported temperature sensor types\u003c\/li\u003e\n\u003cli\u003e3.1-inch backlit LCD and front-panel controls\u003c\/li\u003e\n\u003cli\u003eTwo configurable 4–20 mA outputs\u003c\/li\u003e\n\u003cli\u003eRS485 Modbus RTU communication for PLC integration\u003c\/li\u003e\n\u003cli\u003eThree relay outputs for alarm and supported control functions\u003c\/li\u003e\n\u003cli\u003eHistorical data logging and trend curve display\u003c\/li\u003e\n\u003cli\u003eAdjustable data recording intervals from 1–999 minutes\u003c\/li\u003e\n\u003cli\u003eUSB export of stored records\u003c\/li\u003e\n\u003cli\u003eIP65-rated ABS enclosure\u003c\/li\u003e\n\u003cli\u003eStandard AC power with an optional 24 VDC version\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"text-align: left;\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e870002D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eMeasurement channels\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003eOne analog pH\/ORP sensor and one analog conductivity sensor, operating simultaneously\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003epH range\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e−2.00 to 16.00 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eORP range\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e−2,000 to +2,000 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eConductivity range\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e0–2,000,000 µS\/cm (0–2,000 mS\/cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eTDS range\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e0–130,000 mg\/L (ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eResistivity range\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e0–20 MΩ·cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eSalinity\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003eSupported; usable range depends on sensor and configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eChannel 1 temperature range\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e−30.0 to 130.0°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eChannel 2 temperature range\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e−40.0 to 200.0°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003epH: ±0.01 pH; ORP: ±1 mV; conductivity: ±2%; temperature: ±0.5°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eTemperature compensation inputs\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003eNTC30k, NTC22k, NTC10k, Pt1000 and NTC2.252k\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eDisplay\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e3.1-inch backlit digital LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eAnalog outputs\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003eTwo configurable 4–20 mA outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eDigital interface\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003eRS485, Modbus RTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eRelays\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003eThree; contacts rated 5 A at 250 VAC or 5 A at 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eData logging\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003eHistorical records and curves; adjustable recording interval 1–999 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eData export\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003eUSB connection to computer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eStandard power\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e100–240 VAC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eOptional power\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003ePower consumption\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e4 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eHousing \/ protection\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003eABS plastic \/ IP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eDimensions \/ weight\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e144 × 144 × 104 mm \/ 0.9 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eOperating environment\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e−20 to 50°C; ≤95% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eStorage environment\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e−40 to 70°C; ≤95% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eAltitude \/ overvoltage category \/ pollution degree\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e≤2,000 m \/ II \/ 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eLanguages\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003eEnglish, Simplified Chinese, Traditional Chinese and Russian\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eCountry of origin\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003eChina\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eListed measurement limits are controller capabilities. Select compatible electrodes with ranges, temperature ratings and process connections appropriate for the application.\u003c\/p\u003e\n\u003ch4\u003eDownloads\u003c\/h4\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cstrong\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/800002-i.pdf?v=1598908085\" target=\"_blank\"\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/pdf-icon-63x63_480x480.png?v=1598991821\" style=\"float: left;\" alt=\"PDF\"\u003e \u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/800002-i.pdf?v=1598908085\" target=\"_blank\"\u003e\u003cbr\u003eSper Scientific 870002D Instruction Manual\u003c\/a\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003eFAQs\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eCan the DCA130 measure pH and conductivity at the same time?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. It supports one pH\/ORP sensor and one conductivity sensor simultaneously.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan it measure pH and ORP simultaneously?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe first channel uses a pH or ORP sensor. The second channel is intended for conductivity measurements.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat measurements are available on the conductivity channel?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eConductivity, TDS, salinity and resistivity functions are supported. Available ranges depend on the electrode and configuration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan it connect to a PLC?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The analyzer provides RS485 Modbus RTU and two configurable 4–20 mA outputs.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan historical readings be exported?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. Stored data can be exported to a computer over USB. Logging pauses while the USB connection is active and resumes after disconnection.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAre sensors included?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSensor inclusion has not been specified. Select the required pH\/ORP and conductivity probes for your installation and confirm the package before ordering.\u003c\/p\u003e","brand":"Sper Scientific","offers":[{"title":"Default Title","offer_id":68104970076384,"sku":"870002D","price":947.5,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/online-dual-channel-phconductivity-analyzer-870002d-1476214.jpg?v=1793360781"},{"product_id":"online-dpd-colorimetry-chlorine-analyzer","title":"Online DPD Colorimetry Chlorine Analyzer","description":"\u003ch1\u003eThe Sper Scientific 870017 DPD Colorimetry Chlorine Analyzer measures residual chlorine online for drinking water and disinfection processes.\u003c\/h1\u003e\n\u003cp\u003eOnline monitoring system designed for drinking water and disinfection processes to continuously measure free and total residual chlorine using the DPD colorimetric method.\u003cstrong\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDPD Colorimetry Analysis is a standard method for detecting free residual chlorine and total residual chlorine. Automatic reagent dosing and calibration supports routine monitoring, while the touchscreen provides access to measurements, settings and records. Connect the analyzer to process controls through analog and digital outputs. Stored measurement and calibration records can be exported to a USB drive for review. \u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDPD Colorimetry Analysis\u003c\/li\u003e\n\u003cli\u003eAutomatic or manual measurement\u003c\/li\u003e\n\u003cli\u003eAutomatic reagent addition and calibration\u003c\/li\u003e\n\u003cli\u003eColor touchscreen with English language support\u003c\/li\u003e\n\u003cli\u003eUSB export of historical data\u003c\/li\u003e\n\u003cli\u003eAnalog output, digital communication and configurable alarm relays\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003ePart number\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e870017\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eMethod\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003eDPD colorimetry\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eRange\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e0–5.00 mg\/L (ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eAccuracy\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e±5% of reading or ±0.03 mg\/L, whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eResolution\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e0.01 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eAnalysis time\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e180 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eDefault measurement interval\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e600 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eDisplay\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e4.3-inch color LCD touchscreen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eAnalog output\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e4–20 mA; maximum load 500 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eDigital communication\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003eRS485, Modbus RTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eRelays\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003eTwo adjustable high\/low alarm contacts with hysteresis; 5 A at 250 VAC or 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003ePower\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e100–240 VAC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eSample temperature\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e5–40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eOperating environment\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e5–40°C; ≤95% RH, noncondensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eDimensions\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e500 × 400 × 200 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eWeight\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e6.5 kg without reagents\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eReagent capacity\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003eTwo 1,000 mL bottles; approximately 5,000 measurements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eCountry of origin\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003eChina\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003eFAQs\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eWhat does it measure?\u003c\/strong\u003e\u003cbr\u003eResidual chlorine using the DPD colorimetric method.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan it connect to a control system?\u003c\/strong\u003e\u003cbr\u003eYes, through the outputs and relay contacts listed above.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAre reagents required?\u003c\/strong\u003e\u003cbr\u003eYes. Reagent dosing is part of the measurement process. Package contents require confirmation.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"Sper Scientific","offers":[{"title":"Default Title","offer_id":68122345373920,"sku":"870017","price":4300.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/online-dpd-colorimetry-chlorine-analyzer-870017-7205495.jpg?v=1793360779"},{"product_id":"explosion-proof-online-ph-orp-analyzer","title":"Explosion-Proof Online pH\/ORP Analyzer","description":"\u003ch1\u003eThe Sper Scientific Explosion-Proof Online pH\/ORP Analyzer supports continuous pH or ORP and temperature monitoring with a compatible analog electrode.\u003c\/h1\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cstrong\u003eThe Sper Scientific 870002E\u003c\/strong\u003e\u003cspan\u003e\u003cstrong\u003e monitors pH or oxidation-reduction potential (ORP) in industrial water and process solutions.\u003c\/strong\u003e Its online design provides continuous readings, helping operators track changing conditions throughout a process.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eConnect a compatible analog pH or ORP sensor to measure the selected parameter along with temperature. The analyzer sends a 4–20 mA signal to connected monitoring equipment, allowing readings to be incorporated into a plant’s process monitoring system.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe 870002E is suited to applications such as wastewater treatment, drinking water processing, chemical production and power generation. Its explosion-proof design and low power consumption support use in industrial environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eFeatures\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eContinuous online monitoring\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e of pH or ORP and temperature\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eAnalog sensor compatibility\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e for the selected measurement\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eTwo-wire 4–20 mA output\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e for connection to monitoring equipment\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eExplosion-proof design\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e for suitable industrial applications\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eLow power consumption\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e for continuous operation\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch4\u003e\u003cspan style=\"font-family: -apple-system, BlinkMacSystemFont, 'San Francisco', 'Segoe UI', Roboto, 'Helvetica Neue', sans-serif; font-size: 0.875rem;\"\u003eSpecifications\u003c\/span\u003e\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003ePart number\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e\u003cstrong\u003e870002E\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003epH range \/ accuracy\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e−2 to 16 pH \/ ±0.05 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eORP range \/ accuracy\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e−2,000 to +2,000 mV \/ ±1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eTemperature range \/ accuracy\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e0–130°C \/ ±0.5°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003ePower\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e18–30 VDC; 0.66 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eOutput\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003eTwo-wire 4–20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eHousing\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003eAluminum; IP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eOperating environment\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e−20 to +50°C; 0–95% RH, noncondensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eStorage environment\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e−40 to +70°C; 0–95% RH, noncondensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"Sper Scientific","offers":[{"title":"Default Title","offer_id":68185306169568,"sku":"870002E","price":1350.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/explosion-proof-online-phorp-analyzer-870002e-8819373.jpg?v=1793360781"},{"product_id":"explosion-proof-two-wire-online-conductivity-analyzer","title":"Explosion-Proof Two-Wire Online Conductivity Analyzer","description":"\u003ch1\u003eThe Sper Scientific 870003E Two-Wire Explosion-Proof Online Conductivity Analyzer supports continuous conductivity, salinity, TDS, resistivity and temperature monitoring with a compatible analog sensor.\u003c\/h1\u003e\n\u003cp\u003e\u003cstrong\u003eThe Sper Scientific 870003E 2-Wire Explosion-Proof Online Electrical Conductivity Analyzer\u003c\/strong\u003e\u003cspan\u003e\u003cstrong\u003e provides continuous monitoring of conductivity, salinity, total dissolved solids (TDS), resistivity and temperature in water and process solutions.\u003c\/strong\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eUsed with a compatible analog conductivity sensor, it is suitable for wastewater treatment, power generation, chemical processing, pharmaceutical manufacturing, food processing and drinking water applications. \u003c\/span\u003e\u003cspan\u003eA two-wire 4–20 mA output connects the analyzer to process monitoring equipment, while low power consumption supports continuous operation in industrial installations.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eConstruction\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe analyzer features a die-cast aluminum housing with an IP65 rating for protection against dust and water. Its construction supports use in demanding industrial environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eFeatures\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eContinuous monitoring of conductivity, salinity, TDS, resistivity and temperature\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCompatible with analog conductivity sensors\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eTwo-wire 4–20 mA output\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLow power consumption\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eDie-cast aluminum housing with IP65 protection\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eExplosion-proof design with manufacturer-listed \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eEx ia IIC T6 Ga\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e marking\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan style=\"font-family: -apple-system, BlinkMacSystemFont, 'San Francisco', 'Segoe UI', Roboto, 'Helvetica Neue', sans-serif; font-size: 0.875rem;\"\u003eSpecifications\u003c\/span\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003ePart number\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e870003E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eConductivity, K = 0.01\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e0.01–20 µS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eConductivity, K = 0.1\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e0.1–200 µS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eConductivity, K = 1.0\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e1–2,000 µS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eConductivity, K = 10.0\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e10–20,000 µS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eSalinity\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e0.00–80.00 ppt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eTDS\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e0–130,000 mg\/L (ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eResistivity\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e0–20 MΩ·cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eTemperature inputs \/ ranges\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003ePt100, Pt1000 or NTC10k: −40 to +200°C; NTC2.252k: −30 to +150°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eAccuracy\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e±0.5% F.S.; temperature ±0.3°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eOutput\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003eOne two-wire 4–20 mA output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eOutput error\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e≤±0.3% F.S. or ±0.05 mA, whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003ePower\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e18–30 VDC; 0.66 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eHousing\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003eDie-cast aluminum; IP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eDimensions \/ weight\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e144 × 144 × 147 mm; 1.35 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eOperating environment\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e−20 to +60°C; ≤95% RH, noncondensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eStorage temperature\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e−40 to +70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Sper Scientific","offers":[{"title":"Default Title","offer_id":68188570747104,"sku":"870003E","price":1500.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/explosion-proof-two-wire-online-conductivity-analyzer-870003e-3346998.jpg?v=1793360779"},{"product_id":"online-conductivity-and-acid-base-analyzer-870009a","title":"Online Conductivity and Acid\/Base Analyzer","description":"\u003ch1\u003eThe Sper Scientific 870009A Online Conductivity and Acid\/Base Analyzer continuously monitors conductivity, resistivity, salinity, total dissolved solids (TDS), temperature and the concentration of selected chemical solutions.\u003c\/h1\u003e\n\u003cp\u003e\u003cstrong\u003ePaired with a compatible digital conductivity sensor, it supports applications from pure water systems to industrial process water and wastewater treatment. \u003c\/strong\u003eA backlit display provides local readings. Dual analog outputs and RS485 Modbus RTU communication connect the controller to process monitoring systems. Alarm and cleaning functions support routine operation, while historical data recording helps users review measurement trends.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMultiple measurement modes with compatible digital sensors\u003c\/li\u003e\n\u003cli\u003eTwo 4–20 mA outputs and RS485 Modbus RTU\u003c\/li\u003e\n\u003cli\u003eHigh\/low alarms and cleaning relay function\u003c\/li\u003e\n\u003cli\u003eHistorical data recording and retention of settings after power loss\u003c\/li\u003e\n\u003cli\u003ePanel-mount controller with IP65 protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003ePart number\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e\u003cstrong\u003e870009A\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eDisplay\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e3.1-inch backlit LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003ePower supply\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e100–240 VAC, 50\/60 Hz; 24 V option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003ePower consumption\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e4 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eOutputs\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003eTwo 4–20 mA outputs; RS485 Modbus RTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eRelays\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003eHigh\/low alarm and cleaning function; 5 A at 250 VAC or 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eConductivity\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e0–2,000,000 µS\/cm (0–2,000 mS\/cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eSalinity\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e0–80.00 ppt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eTDS\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e0–60,000 mg\/L (ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eResistivity\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e0–20.00 MΩ·cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eTemperature\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e0–150.0°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eAcid\/base concentration\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003eCompound-dependent; see ranges below\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eHousing \/ protection\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003eABS plastic; IP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eDimensions \/ weight\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e144 × 144 × 104 mm; 0.9 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eOperating conditions\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e−40 to 70°C; ≤95% RH, noncondensing; altitude ≤2,000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eController ranges are shown; actual performance and usable ranges depend on the selected sensor.\u003c\/p\u003e\n\u003ch4\u003eAcid, Base and Salt Concentration Ranges\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eHCl\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e0–18%; 22–39% at 25°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eHNO₃\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e0–29%; 35–96% at 25°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eH₂SO₄\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e0–29%; 30–83%; 93–100% at 10°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eNaCl\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e0–26% at 20°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eNaOH\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e0–14%; 18–50% at 25°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eKOH\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e0–29%; 29–48% at 25°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eHF\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e0–36% at 25°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eCaCl₂\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e0–25%; 25–40% at 25°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eCH₃COOH\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e0–17%; 17–70% at 25°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eH₃PO₄\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e0–35% at 25°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eNa₂CO₃\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e0–19% at 25°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Sper Scientific","offers":[{"title":"Default Title","offer_id":68205136380128,"sku":"870009A","price":997.5,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/online-conductivity-and-acidbase-analyzer-870009a-8652391.jpg?v=1793360777"},{"product_id":"online-industrial-silicate-analyzer","title":"Online Industrial Silicate Analyzer","description":"\u003ch1\u003eThe Sper Scientific \u003cmeta charset=\"utf-8\"\u003eOnline Industrial Silicate Analyzer monitors silicate levels in process water using automated chemical reaction and optical detection.\u003c\/h1\u003e\n\u003cp\u003eIt supports applications such as power plant feedwater, steam-cycle monitoring and industrial water treatment where low concentrations must be tracked. A color LCD displays results and historical trends, while the 4–20 mA output and RS485 communication connect the analyzer to monitoring equipment. Automatic calibration can be scheduled to suit the application. Optional multi-channel configurations allow the analyzer to measure multiple sample streams.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAutomated chemical reaction and optical measurement\u003c\/li\u003e\n\u003cli\u003eColor display with English-language menus and trend curves\u003c\/li\u003e\n\u003cli\u003eHistorical data recording for up to 30 days\u003c\/li\u003e\n\u003cli\u003eAutomatic calibration with adjustable interval\u003c\/li\u003e\n\u003cli\u003eOne to six sample channels available by configuration\u003c\/li\u003e\n\u003cli\u003eAudible and relay alarms\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable style=\"width: 100%; height: 313.501px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth style=\"text-align: left; width: 28.0128%; height: 19.5938px;\"\u003ePart number\u003c\/th\u003e\n\u003ctd style=\"text-align: left; width: 69.665%; height: 19.5938px;\"\u003e\u003cstrong\u003e870018\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth style=\"text-align: left; width: 28.0128%; height: 19.5938px;\"\u003eMeasurement ranges\u003c\/th\u003e\n\u003ctd style=\"text-align: left; width: 69.665%; height: 19.5938px;\"\u003e0–20, 0–100 or 0–2,000 µg\/L; 0–5,000 µg\/L special range available\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth style=\"text-align: left; width: 28.0128%; height: 19.5938px;\"\u003eAccuracy\u003c\/th\u003e\n\u003ctd style=\"text-align: left; width: 69.665%; height: 19.5938px;\"\u003e±1% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth style=\"text-align: left; width: 28.0128%; height: 19.5938px;\"\u003eRepeatability\u003c\/th\u003e\n\u003ctd style=\"text-align: left; width: 69.665%; height: 19.5938px;\"\u003e±1% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth style=\"text-align: left; width: 28.0128%; height: 19.5938px;\"\u003eDrift\u003c\/th\u003e\n\u003ctd style=\"text-align: left; width: 69.665%; height: 19.5938px;\"\u003e≤±1% of full scale per 24 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth style=\"text-align: left; width: 28.0128%; height: 19.5938px;\"\u003eResponse\u003c\/th\u003e\n\u003ctd style=\"text-align: left; width: 69.665%; height: 19.5938px;\"\u003e12 minutes initial; 10 minutes per channel during continuous operation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth style=\"text-align: left; width: 28.0128%; height: 19.5938px;\"\u003eSample conditions\u003c\/th\u003e\n\u003ctd style=\"text-align: left; width: 69.665%; height: 19.5938px;\"\u003eFlow \u0026gt;50 mL\/s; temperature 10–45°C; pressure 10–100 kPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth style=\"text-align: left; width: 28.0128%; height: 19.5938px;\"\u003eAmbient conditions\u003c\/th\u003e\n\u003ctd style=\"text-align: left; width: 69.665%; height: 19.5938px;\"\u003e5–45°C; accuracy decreases above 40°C; \u0026lt;85% RH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth style=\"text-align: left; width: 28.0128%; height: 19.5938px;\"\u003eReagent consumption\u003c\/th\u003e\n\u003ctd style=\"text-align: left; width: 69.665%; height: 19.5938px;\"\u003eThree reagents; approximately 1 L of each per month\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth style=\"text-align: left; width: 28.0128%; height: 19.5938px;\"\u003eOutput\u003c\/th\u003e\n\u003ctd style=\"text-align: left; width: 69.665%; height: 19.5938px;\"\u003e4–20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth style=\"text-align: left; width: 28.0128%; height: 19.5938px;\"\u003eAlarms\u003c\/th\u003e\n\u003ctd style=\"text-align: left; width: 69.665%; height: 19.5938px;\"\u003eBuzzer and normally open relay contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth style=\"text-align: left; width: 28.0128%; height: 19.5938px;\"\u003eCommunications\u003c\/th\u003e\n\u003ctd style=\"text-align: left; width: 69.665%; height: 19.5938px;\"\u003eRS485 Modbus RTU; LAN, Wi-Fi or 4G options\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth style=\"text-align: left; width: 28.0128%; height: 19.5938px;\"\u003ePower\u003c\/th\u003e\n\u003ctd style=\"text-align: left; width: 69.665%; height: 19.5938px;\"\u003e220 VAC ±10%, 50 Hz; approximately 50 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth style=\"text-align: left; width: 28.0128%; height: 19.5938px;\"\u003eDimensions\u003c\/th\u003e\n\u003ctd style=\"text-align: left; width: 69.665%; height: 19.5938px;\"\u003e720 × 460 × 300 mm (H × W × D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth style=\"text-align: left; width: 28.0128%; height: 19.5938px;\"\u003eMounting hole dimensions\u003c\/th\u003e\n\u003ctd style=\"text-align: left; width: 69.665%; height: 19.5938px;\"\u003e665 × 405 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4\u003eFAQs\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eHow often does the analyzer measure?\u003c\/strong\u003e\u003cbr\u003eDuring continuous operation, the specified sampling period is 10 minutes per channel.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan it monitor multiple sample streams?\u003c\/strong\u003e\u003cbr\u003eConfigurations with one to six channels are available.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes it need reagents?\u003c\/strong\u003e\u003cbr\u003eYes. The analyzer uses three reagents that must be replenished.\u003c\/p\u003e","brand":"Sper Scientific","offers":[{"title":"Default Title","offer_id":68217370083552,"sku":"870018","price":12497.5,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/online-industrial-silicate-analyzer-870018-5209569.jpg?v=1793360777"},{"product_id":"online-industrial-sodium-analyzer","title":"Online Industrial Sodium Analyzer","description":"\u003ch1\u003eThe Sper Scientific 870020 Industrial Online Sodium Analyzer continuously monitors sodium ions in water and process solutions.\u003c\/h1\u003e\n\u003cp\u003e\u003cstrong\u003eIts low-concentration measurement capability supports water chemistry monitoring in power generation, water treatment and industrial processing.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe analyzer combines a sodium measuring electrode with an automatic sample flow system and alkalization system. An English-language display presents readings, while isolated analog outputs and RS485 communication connect the analyzer to monitoring equipment. Historical measurements can be reviewed as a trend curve.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eContinuous online sodium monitoring\u003c\/li\u003e\n\u003cli\u003eAutomatic temperature compensation\u003c\/li\u003e\n\u003cli\u003eAutomatic sample flow and pressure compensation\u003c\/li\u003e\n\u003cli\u003eAdjustable high and low alarm thresholds\u003c\/li\u003e\n\u003cli\u003eApproximately one month of historical data and a 200-message event log\u003c\/li\u003e\n\u003cli\u003eOne to six sample channels available by configuration\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003ePart number\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e\u003cstrong\u003e870020\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eSodium measurement ranges\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e0–100 µg\/L; 0–2,300 mg\/L; 0.00–8.00 pNa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eResolution\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e0.1 µg\/L; 0.01 mg\/L; 0.01 pNa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eBasic error\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e±2.5%; temperature ±0.3°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eTemperature compensation\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003eAutomatic, 0–60°C; referenced to 25°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eRepeatability\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e±2.5% of reading (electronic unit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eStability\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e±2.5% of reading per 24 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eSample temperature\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e0–60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eData storage\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003eApproximately one month, one point every five minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eIsolated outputs\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e0–10 mA, load \u0026lt;1.5 kΩ; 4–20 mA, load \u0026lt;750 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eOutput current error\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e≤±1% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eAlarm contacts\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003eNormally open; 250 VAC, 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eCommunication\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003eRS485 Modbus RTU; LAN, Wi-Fi or 4G options\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003ePower\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e220 VAC ±10%, 50 ±1 Hz; approximately 50 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eDimensions\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e720 × 460 × 300 mm (H × W × D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eMounting hole dimensions\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e665 × 405 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003e\u003c\/h4\u003e\n\u003ch4\u003eFAQs\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eWhat does the analyzer measure?\u003c\/strong\u003e\u003cbr\u003eSodium ions in water and process solutions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan it monitor multiple sample streams?\u003c\/strong\u003e\u003cbr\u003eConfigurations with one to six channels are available.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow are readings transmitted?\u003c\/strong\u003e\u003cbr\u003eThrough an isolated analog output or RS485 communication.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Sper Scientific","offers":[{"title":"Default Title","offer_id":68285151510752,"sku":"870020","price":8747.5,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/online-industrial-sodium-analyzer-870020-5068526.jpg?v=1793360776"},{"product_id":"online-trace-dissolved-oxygen-sensor-for-high-purity-water","title":"Online Trace Dissolved Oxygen Sensor for High-Purity Water","description":"\u003ch1\u003eThis industrial dissolved oxygen sensor monitors trace oxygen in high-purity water, boiler feedwater and power plant water systems.\u003c\/h1\u003e\n\u003cp\u003eDesigned for low-level dissolved oxygen measurement, the sensor uses a polarographic electrode with a platinum cathode, silver\/silver chloride anode and silicone rubber membrane. It detects oxygen concentrations as low as 0.1 µg\/L at 20 °C, helping operators monitor water conditions in oxygen-sensitive processes.\u003c\/p\u003e\n\u003cp\u003eA 316L stainless steel body and double-shielded 5 m cable suit industrial installations. Temperature compensation elements are available to match the connected analyzer. The sensor requires polarization before use and a continuous flow of sample water across the membrane.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eTrace dissolved oxygen measurement for high-purity water applications\u003c\/li\u003e\n\u003cli\u003ePolarographic sensing with a platinum cathode and Ag\/AgCl anode\u003c\/li\u003e\n\u003cli\u003eSilicone rubber membrane supported by steel gauze\u003c\/li\u003e\n\u003cli\u003e316L stainless steel electrode body\u003c\/li\u003e\n\u003cli\u003eDouble-shielded 5 m cable\u003c\/li\u003e\n\u003cli\u003eTemperature compensation options for compatible analyzers\u003c\/li\u003e\n\u003cli\u003eFlow cell included\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003e\u003cstrong\u003eProduct\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e\u003cstrong\u003e870007-PWDO\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eMeasurement principle\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003ePolarographic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003ePublished measuring ranges\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e0–100 µg\/L; 0–20 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eDetection limit\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e0.1 µg\/L at 20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eResponse time\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e≤3 minutes to 90% of final reading at 20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eSample water temperature\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e0–60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eElectrode body\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e316L stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eElectrolyte\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e0.1 M potassium chloride (KCl)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eMembrane\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003eSilicone rubber with steel gauze\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eTemperature compensation options\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003ePt100, Pt1000, 22 kΩ or 2.252 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eCable\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e5 m, double-shielded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003ePolarization voltage\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e0.7 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003ePolarization time\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003eMore than 8 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eMinimum sample flow velocity\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e5 cm\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003e\n\u003cbr\u003eFAQs\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eWhere is this sensor used?\u003c\/strong\u003e\u003cbr\u003eIt is intended for trace oxygen monitoring in thermal power plants, demineralized water systems and boiler feed water.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow long does the sensor need to polarize?\u003c\/strong\u003e\u003cbr\u003eThe specified polarization time is more than 8 hours.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the sample need to flow?\u003c\/strong\u003e\u003cbr\u003eYes. The specified minimum sample velocity is 5 cm\/s across the sensing membrane.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I select the temperature compensation element?\u003c\/strong\u003e\u003cbr\u003eMatch it to your analyzer's input requirements. \u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"Sper Scientific","offers":[{"title":"Default Title","offer_id":68326668763360,"sku":"870007-PWDO","price":1325.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/online-trace-dissolved-oxygen-sensor-for-high-purity-water-870007-do8f-2606511.jpg?v=1793360766"},{"product_id":"online-ultra-pure-water-ph-and-temperature-electrode","title":"Online Ultra-Pure Water pH and Temperature Electrode","description":"\u003ch1\u003eThe 870002-PHA Ultra-Pure Water pH electrode measures pH and temperature in pure-water and high-purity water systems.\u003c\/h1\u003e\n\u003cp\u003eA polymer-filled reference system helps stabilize the reference junction potential. Its large-area diaphragm sits close to the glass sensing membrane, creating a short, consistent path between the reference junction and measuring element. This arrangement supports a fast response and helps reduce the effect of changes in sample flow on measurement stability.\u003c\/p\u003e\n\u003cp\u003eControlled electrolyte diffusion limits the amount of electrolyte entering the sample, making the electrode suitable for pure-water monitoring. Applications include thermal power plant water systems, where a suitable flow-through cell is required.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDesigned for pure water and high-purity water applications\u003c\/li\u003e\n\u003cli\u003eMeasures pH and temperature with a compatible analyzer\u003c\/li\u003e\n\u003cli\u003ePolymer-filled reference junction for stable potential\u003c\/li\u003e\n\u003cli\u003eLarge-area diaphragm positioned close to the glass sensing membrane\u003c\/li\u003e\n\u003cli\u003eLow-noise cable connection\u003c\/li\u003e\n\u003cli\u003eQuarter-turn twist-lock mounting for insertion and removal\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003e\u003cstrong\u003ePart number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e\u003cstrong\u003e870002-PHA\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eMeasurement parameters\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003epH and temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003epH range\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e0.0–14.0 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eTemperature range\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e0–60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003ePublished pH accuracy\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e±0.1 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003ePublished temperature accuracy\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e±0.5 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eSlope\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e≥96%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eZero point\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e7 pH ±0.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eTemperature compensation options\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e10 kΩ, 2.252 kΩ, Pt100 or Pt1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eMounting\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003eTwist-lock with 3\/4 in. rear-facing threads\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eElectrical connection\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003eLow-noise cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eApplication\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003ePure water and high-purity water monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eFAQs\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eWhy is this electrode suited to pure water?\u003c\/strong\u003e\u003cbr\u003eIts polymer-filled reference system and closely spaced reference junction help maintain stable measurements while controlling electrolyte diffusion into the sample.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow is the electrode installed?\u003c\/strong\u003e\u003cbr\u003eIt uses twist-lock mounting and 3\/4 in. rear-facing threads. A quarter turn inserts or removes the electrode from the process connection.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan it connect to any pH analyzer?\u003c\/strong\u003e\u003cbr\u003eConfirm the electrode input and temperature compensation requirements of your analyzer before ordering.\u003c\/p\u003e","brand":"Sper Scientific","offers":[{"title":"Default Title","offer_id":68328591655136,"sku":"870002-PHA","price":362.5,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/online-ultra-pure-water-ph-and-temperature-electrode-870002-pha-5629704.jpg?v=1793360772"},{"product_id":"high-temperature-ph-sensor-with-vp-connector","title":"Online High-Temperature pH Sensor with VP Connector","description":"\u003ch1\u003eThis high-temperature pH sensor supports online pH and temperature monitoring in processes that use clean-in-place and sterilize-in-place cycles.\u003c\/h1\u003e\n\u003cp\u003eDesigned for fermentation, biotechnology, pharmaceutical manufacturing and food processing, the sensor measures 0–14 pH and operates at temperatures up to 130 °C. A double-junction electrode design supports industrial measurement through the temperature changes associated with cleaning and sterilization.\u003c\/p\u003e\n\u003cp\u003eThe VP connection works with compatible VP6 cabling, while the PG13.5 process thread supports installation with a suitable holder or sheath. Choose a T or Y configuration in 120, 150, 225 or 325 mm electrode lengths to match your process installation.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOnline pH and temperature monitoring for high-temperature processes\u003c\/li\u003e\n\u003cli\u003eSuitable for applications using CIP and SIP procedures\u003c\/li\u003e\n\u003cli\u003eVP electrical connection and PG13.5 process thread\u003c\/li\u003e\n\u003cli\u003e12 mm electrode diameter\u003c\/li\u003e\n\u003cli\u003eFour electrode lengths and two configuration choices\u003c\/li\u003e\n\u003cli\u003eCompatible with suitable 316L stainless steel sheaths\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable style=\"width: 100%; height: 313.5px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"text-align: left; width: 26.4255%; height: 39.1875px;\"\u003eMeasurement parameters\u003c\/td\u003e\n\u003ctd style=\"text-align: left; width: 70.9033%; height: 39.1875px;\"\u003epH and temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"text-align: left; width: 26.4255%; height: 19.5938px;\"\u003epH range\u003c\/td\u003e\n\u003ctd style=\"text-align: left; width: 70.9033%; height: 19.5938px;\"\u003e0–14 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"text-align: left; width: 26.4255%; height: 19.5938px;\"\u003ePublished pH accuracy\u003c\/td\u003e\n\u003ctd style=\"text-align: left; width: 70.9033%; height: 19.5938px;\"\u003e±0.1 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"text-align: left; width: 26.4255%; height: 19.5938px;\"\u003eOperating temperature\u003c\/td\u003e\n\u003ctd style=\"text-align: left; width: 70.9033%; height: 19.5938px;\"\u003e0–130 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"text-align: left; width: 26.4255%; height: 19.5938px;\"\u003ePressure resistance\u003c\/td\u003e\n\u003ctd style=\"text-align: left; width: 70.9033%; height: 19.5938px;\"\u003e0–0.6 MPa (0–6 bar)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"text-align: left; width: 26.4255%; height: 19.5938px;\"\u003eElectrical connector\u003c\/td\u003e\n\u003ctd style=\"text-align: left; width: 70.9033%; height: 19.5938px;\"\u003eVP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"text-align: left; width: 26.4255%; height: 19.5938px;\"\u003eCompatible cable\u003c\/td\u003e\n\u003ctd style=\"text-align: left; width: 70.9033%; height: 19.5938px;\"\u003eVP6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"text-align: left; width: 26.4255%; height: 19.5938px;\"\u003eProcess thread\u003c\/td\u003e\n\u003ctd style=\"text-align: left; width: 70.9033%; height: 19.5938px;\"\u003ePG13.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"text-align: left; width: 26.4255%; height: 19.5938px;\"\u003eElectrode diameter\u003c\/td\u003e\n\u003ctd style=\"text-align: left; width: 70.9033%; height: 19.5938px;\"\u003e12 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"text-align: left; width: 26.4255%; height: 39.1875px;\"\u003eAvailable electrode lengths\u003c\/td\u003e\n\u003ctd style=\"text-align: left; width: 70.9033%; height: 39.1875px;\"\u003e120, 150, 225 and 325 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"text-align: left; width: 26.4255%; height: 39.1875px;\"\u003eTemperature compensation\u003c\/td\u003e\n\u003ctd style=\"text-align: left; width: 70.9033%; height: 39.1875px;\"\u003ePt1000 or 10 kΩ, depending on configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"text-align: left; width: 26.4255%; height: 39.1875px;\"\u003eReference system\u003c\/td\u003e\n\u003ctd style=\"text-align: left; width: 70.9033%; height: 39.1875px;\"\u003eDouble liquid junction; electrolyte configuration depends on the selected version\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eDownloads\u003c\/h4\u003e\n\u003cp\u003ePlease \u003ca href=\"https:\/\/sperdirect.com\/pages\/contact-us\"\u003econtact us\u003c\/a\u003e for the product datasheet and installation guidance.\u003c\/p\u003e\n\u003ch3\u003eOptions\u003c\/h3\u003e\n\u003cp\u003eSelect the T or Y configuration and required electrode length. Contact us for help matching the reference system and temperature compensation element to your analyzer and process.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth scope=\"col\" style=\"text-align: left;\"\u003eLength\u003c\/th\u003e\n\u003cth scope=\"col\" style=\"text-align: left;\"\u003eT Configuration\u003c\/th\u003e\n\u003cth scope=\"col\" style=\"text-align: left;\"\u003eY Configuration\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003e120 mm\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e870002-HPHT-120\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e870002-HPHY-120\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003e150 mm\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e870002-HPHT-150\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e870002-HPHY-150\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003e225 mm\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e870002-HPHT-225\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e870002-HPHY-225\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003e325 mm\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e870002-HPHT-1325\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e870002-HPHY-325\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eAccessories\u003c\/h3\u003e\n\u003cp\u003eVP6-compatible cabling and suitable 316L stainless steel sheaths support analyzer and process connections. Photos show a representative electrode length and compatible cable. Confirm cable and mounting hardware requirements with your order.\u003c\/p\u003e\n\u003ch4\u003eFAQs\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the maximum operating temperature?\u003c\/strong\u003e\u003cbr\u003eThe specified operating range is 0–130 °C.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhich connector does this listing use?\u003c\/strong\u003e\u003cbr\u003eAll eight variants use a VP electrical connection.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhich electrode lengths are available?\u003c\/strong\u003e\u003cbr\u003eChoose 120, 150, 225 or 325 mm in either T or Y configuration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhere can this sensor be used?\u003c\/strong\u003e\u003cbr\u003eTypical applications include fermentation vessels, bioreactors, pharmaceutical production and food or beverage processing.\u003c\/p\u003e","brand":"Sper Scientific","offers":[{"title":"T \/ 120 mm","offer_id":68330364010720,"sku":"870002-HPHT-120","price":472.0,"currency_code":"USD","in_stock":true},{"title":"T \/ 150 mm","offer_id":68330364043488,"sku":"870002-HPHT-150","price":622.5,"currency_code":"USD","in_stock":true},{"title":"T \/ 225 mm","offer_id":68330364076256,"sku":"870002-HPHT-225","price":747.5,"currency_code":"USD","in_stock":true},{"title":"T \/ 325 mm","offer_id":68330364109024,"sku":"870002-HPHT-325","price":872.5,"currency_code":"USD","in_stock":true},{"title":"Y \/ 120 mm","offer_id":68330364141792,"sku":"870002-HPHY-120","price":472.0,"currency_code":"USD","in_stock":true},{"title":"Y \/ 150 mm","offer_id":68330364174560,"sku":"870002-HPHY-150","price":622.5,"currency_code":"USD","in_stock":true},{"title":"Y \/ 225 mm","offer_id":68330364207328,"sku":"870002-HPHY-225","price":747.5,"currency_code":"USD","in_stock":true},{"title":"Y \/ 325 mm","offer_id":68330364240096,"sku":"870002-HPHY-325","price":872.5,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/online-high-temperature-ph-sensor-with-vp-connector-870002-hpht-120-7278134.jpg?v=1793360773"},{"product_id":"online-sterilizable-glass-ph-sensor-120-mm","title":"Online Sterilizable Glass pH Sensor - 120 mm","description":"\u003ch1\u003eSterilizable Glass pH Sensor for Fermentation and Process Monitoring\u003c\/h1\u003e\n\u003cp\u003eThe Sper Scientific 120 mm glass pH sensor measures from 0.00 to 14.00 pH in pharmaceutical production, biochemical processes, industrial fermentation, brewing and food processing. Its heat-resistant construction supports applications that require sterilization between production cycles.\u003c\/p\u003e\n\u003cp\u003eA dual liquid junction and gel electrolyte reference system help provide stable measurements with reduced routine electrolyte maintenance. The Ag\/AgCl reference incorporates a silver ion trap to help prevent silver sulfide deposits at the ceramic junction. The manual specifies a temperature measurement range of 0–80°C and a separate heat-resistance range of 0–130°C.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFull 0.00–14.00 pH measurement range with a listed response time of 30–60 seconds\u003c\/li\u003e\n\u003cli\u003e120 mm insertion length with a 12 mm glass sensing shaft\u003c\/li\u003e\n\u003cli\u003eHeat-resistant construction for fermentation and sterilization applications within the specified limits\u003c\/li\u003e\n\u003cli\u003eDual liquid junction with gel electrolyte and ceramic separator\u003c\/li\u003e\n\u003cli\u003eSilver ion trap to help protect the reference junction from silver sulfide deposits\u003c\/li\u003e\n\u003cli\u003eVP connection with optional temperature compensation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable style=\"width: 100%; height: 293.907px;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth style=\"text-align: left; width: 36.12%; height: 19.5938px;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"text-align: left; width: 61.2088%; height: 19.5938px;\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"text-align: left; width: 36.12%; height: 19.5938px;\"\u003eSper part number\u003c\/td\u003e\n\u003ctd style=\"text-align: left; width: 61.2088%; height: 19.5938px;\"\u003e870002-HPH2-120\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"text-align: left; width: 36.12%; height: 19.5938px;\"\u003eMeasurement\u003c\/td\u003e\n\u003ctd style=\"text-align: left; width: 61.2088%; height: 19.5938px;\"\u003epH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"text-align: left; width: 36.12%; height: 19.5938px;\"\u003epH range\u003c\/td\u003e\n\u003ctd style=\"text-align: left; width: 61.2088%; height: 19.5938px;\"\u003e0.00–14.00 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"text-align: left; width: 36.12%; height: 19.5938px;\"\u003eResponse time\u003c\/td\u003e\n\u003ctd style=\"text-align: left; width: 61.2088%; height: 19.5938px;\"\u003e30–60 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"text-align: left; width: 36.12%; height: 19.5938px;\"\u003eInsertion length\u003c\/td\u003e\n\u003ctd style=\"text-align: left; width: 61.2088%; height: 19.5938px;\"\u003e120 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"text-align: left; width: 36.12%; height: 19.5938px;\"\u003eSensing shaft diameter\u003c\/td\u003e\n\u003ctd style=\"text-align: left; width: 61.2088%; height: 19.5938px;\"\u003e12 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"text-align: left; width: 36.12%; height: 19.5938px;\"\u003eTemperature measurement range\u003c\/td\u003e\n\u003ctd style=\"text-align: left; width: 61.2088%; height: 19.5938px;\"\u003e0–80°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"text-align: left; width: 36.12%; height: 19.5938px;\"\u003eTemperature resistance range\u003c\/td\u003e\n\u003ctd style=\"text-align: left; width: 61.2088%; height: 19.5938px;\"\u003e0–130°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"text-align: left; width: 36.12%; height: 19.5938px;\"\u003ePressure resistance\u003c\/td\u003e\n\u003ctd style=\"text-align: left; width: 61.2088%; height: 19.5938px;\"\u003e0.6 MPa (6 bar); use a suitable process housing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"text-align: left; width: 36.12%; height: 19.5938px;\"\u003eReference system\u003c\/td\u003e\n\u003ctd style=\"text-align: left; width: 61.2088%; height: 19.5938px;\"\u003eGel electrolyte with ceramic separator and silver ion trap\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"text-align: left; width: 36.12%; height: 19.5938px;\"\u003eReference electrode\u003c\/td\u003e\n\u003ctd style=\"text-align: left; width: 61.2088%; height: 19.5938px;\"\u003eAg\/AgCl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"text-align: left; width: 36.12%; height: 19.5938px;\"\u003eJunction design\u003c\/td\u003e\n\u003ctd style=\"text-align: left; width: 61.2088%; height: 19.5938px;\"\u003eDual liquid junction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"text-align: left; width: 36.12%; height: 19.5938px;\"\u003eElectrical connection\u003c\/td\u003e\n\u003ctd style=\"text-align: left; width: 61.2088%; height: 19.5938px;\"\u003eVP connection,  S7 also available\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"text-align: left; width: 36.12%; height: 19.5938px;\"\u003eTemperature compensation\u003c\/td\u003e\n\u003ctd style=\"text-align: left; width: 61.2088%; height: 19.5938px;\"\u003eOptional Pt100, Pt1000 or other specified element\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cbr\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eThis listing is for the 120 mm insertion length with VP connectors\u003c\/strong\u003e, temperature compensation elements and other insertion lengths are configuration dependent. \u003c\/p\u003e\n\u003cp\u003eInstallation requires a matching pH transmitter, connection cable and suitable mounting or process housing.\u003c\/p\u003e\n\u003cp\u003eIf you need assistance, please \u003cmeta charset=\"utf-8\"\u003e\u003ca href=\"https:\/\/sperdirect.com\/pages\/contact-us\"\u003econtact us\u003c\/a\u003e to confirm your specific requirements before ordering.\u003c\/p\u003e\n\u003ch4\u003eFAQs\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eCan the sensor be used for continuous measurement at 130°C?\u003c\/strong\u003e\u003cbr\u003eThe manual lists 0–80°C for temperature measurement and 0–130°C for heat resistance. Confirm continuous operating conditions and sterilization requirements for your application before installation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow is the sensor calibrated?\u003c\/strong\u003e\u003cbr\u003eThe manual recommends two-point calibration using suitable pH buffers. Typical examples are pH 7 for the zero point followed by pH 4 or pH 9 for the slope. Follow the connected transmitter's calibration instructions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow should the electrode be stored?\u003c\/strong\u003e\u003cbr\u003eKeep the sensing tip and junction immersed in suitable KCl storage electrolyte when the sensor is out of service. Rinse the tip after each production cycle and prevent process residue from drying on the glass or junction.\u003c\/p\u003e","brand":"Sper Scientific","offers":[{"title":"Default Title","offer_id":68330718822624,"sku":"870002-HPH2-120","price":825.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/online-sterilizable-glass-ph-sensor-120-mm-870002-hph2-120-3292198.jpg?v=1793360768"},{"product_id":"trace-dissolved-oxygen-sensor-for-high-purity-water","title":"Online Trace Dissolved Oxygen Sensor for High-Purity Water","description":"\u003ch1\u003eThis industrial dissolved oxygen sensor monitors trace oxygen in high-purity water, boiler feedwater and power plant water systems.\u003c\/h1\u003e\n\u003cp\u003eDesigned for low-level dissolved oxygen measurement, the sensor uses a polarographic electrode with a platinum cathode, silver\/silver chloride anode and silicone rubber membrane. It detects oxygen concentrations as low as 0.1 µg\/L at 20 °C, helping operators monitor water conditions in oxygen-sensitive processes.\u003c\/p\u003e\n\u003cp\u003eA 316L stainless steel body and double-shielded 5 m cable suit industrial installations. Temperature compensation elements are available to match the connected analyzer. The sensor requires polarization before use and a continuous flow of sample water across the membrane.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eTrace dissolved oxygen measurement for high-purity water applications\u003c\/li\u003e\n\u003cli\u003ePolarographic sensing with a platinum cathode and Ag\/AgCl anode\u003c\/li\u003e\n\u003cli\u003eSilicone rubber membrane supported by steel gauze\u003c\/li\u003e\n\u003cli\u003e316L stainless steel electrode body\u003c\/li\u003e\n\u003cli\u003eDouble-shielded 5 m cable\u003c\/li\u003e\n\u003cli\u003eTemperature compensation options for compatible analyzers\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003e\u003cstrong\u003eProduct\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e\u003cstrong\u003e870007-DO8F\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eMeasurement principle\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003ePolarographic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003ePublished measuring ranges\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e0–100 µg\/L; 0–20 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eDetection limit\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e0.1 µg\/L at 20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eResponse time\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e≤3 minutes to 90% of final reading at 20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eSample water temperature\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e0–60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eElectrode body\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e316L stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eElectrolyte\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e0.1 M potassium chloride (KCl)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eMembrane\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003eSilicone rubber with steel gauze\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eTemperature compensation options\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003ePt100, Pt1000, 22 kΩ or 2.252 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eCable\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e5 m, double-shielded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003ePolarization voltage\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e0.7 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003ePolarization time\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003eMore than 8 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eMinimum sample flow velocity\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e5 cm\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eTemperature compensation elements are available in Pt100, Pt1000, 22 kΩ and 2.252 kΩ configurations. Match the element to the connected analyzer's input requirements when ordering.\u003c\/p\u003e\n\u003cp\u003eThe photo shows a sensor with a flow cell and fittings; please confirm the supplied configuration for your application, and \u003ca href=\"https:\/\/pt2ygnm1xcw5p9lg-35682484360.shopifypreview.com\/pages\/contact-us\"\u003econtact us\u003c\/a\u003e if you need assistance.\u003c\/p\u003e\n\u003ch4\u003eFAQs\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eWhere is this sensor used?\u003c\/strong\u003e\u003cbr\u003eIt is intended for trace oxygen monitoring in thermal power plants, demineralized water systems and boiler feed water.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow long does the sensor need to polarize?\u003c\/strong\u003e\u003cbr\u003eThe specified polarization time is more than 8 hours.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the sample need to flow?\u003c\/strong\u003e\u003cbr\u003eYes. The specified minimum sample velocity is 5 cm\/s across the sensing membrane.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I select the temperature compensation element?\u003c\/strong\u003e\u003cbr\u003eMatch it to your analyzer's input requirements.\u003c\/p\u003e","brand":"Sper Scientific","offers":[{"title":"Default Title","offer_id":68330906681568,"sku":"870007-DO8F","price":1325.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/online-trace-dissolved-oxygen-sensor-for-high-purity-water-870007-do8f-2606511.jpg?v=1793360766"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/collections\/collection-pharmaceuticals.jpg?v=1793387742","url":"https:\/\/sper-direct.myshopify.com\/collections\/pharmaceuticals.oembed","provider":"Sper Scientific Direct","version":"1.0","type":"link"}