{"title":"Pools and Spas","description":"\u003cp\u003e\u003cstrong\u003ePool and spa water testing helps operators monitor disinfection and water balance.\u003c\/strong\u003e Routine measurements provide a clearer picture of changing conditions and support day-to-day water management.\u003c\/p\u003e\u003cp\u003eExplore portable meters and online monitoring equipment for parameters such as chlorine, pH, ORP and conductivity. Select equipment that matches the treatment system, test range and type of facility.\u003c\/p\u003e","products":[{"product_id":"digital-residual-chlorine-sensor","title":"Online Digital Residual Chlorine Sensor","description":"\u003ch1\u003eSper Scientific Inline Digital Residual Chlorine Sensor is an advanced, intelligent water quality sensor designed for high-performance residual chlorine measurement.\u003cspan class=\"s1\"\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/span\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/span\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/span\u003e\n\u003c\/h1\u003e\n\u003cdiv style=\"text-align: left;\"\u003eUtilizing a non-membrane, constant voltage design, it eliminates the need for diaphragm replacements and reagents, ensuring stable performance and low-maintenance operation. This sensor provides high sensitivity, rapid response, accurate measurements, excellent stability, and superior repeatability, making it ideal for monitoring residual chlorine levels in various applications.\u003c\/div\u003e\n\u003cp\u003eWidely used in automated dosing for circulating water, chlorine management in swimming pools, and continuous monitoring in drinking water treatment plants, distribution networks, pool facilities, hospital wastewater, and water quality management projects.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolated Power and Output Design\u003c\/strong\u003e: Ensures electrical safety and reliable operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuilt-In Power and Communication Protection\u003c\/strong\u003e: Comprehensive protection circuitry for dependable performance without additional isolation equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnhanced Environmental Resistance\u003c\/strong\u003e: Built-in circuitry for easier installation and operation in various settings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRS485 MODBUS-RTU Interface\u003c\/strong\u003e: Supports two-way communication for remote commands.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUser-Friendly Communication Protocol\u003c\/strong\u003e: Simple and practical for easy use and integration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSmart Diagnostic Information Output\u003c\/strong\u003e: Provides extensive electrode diagnostic details.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated Memory\u003c\/strong\u003e: Stores calibration and settings, retained even after power-off.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003eOrdering Notes: \u003cbr\u003e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003e1. All Sper Inline \u003ca title=\"Inline Water Quality Monitoring\" href=\"https:\/\/sperdirect.com\/collections\/inline-water-quality-monitors-sensors\"\u003eWater Quality Meters and Sensors\u003c\/a\u003e are sold separately - one of each is required for a complete system. \u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003e\u003cspan\u003e\u003cspan style=\"color: #ff2a00;\"\u003e2. All Inline Water Quality Meters and Sensors ship direct from the factory. Please allow 10-15 business days for shipping and \u003cspan style=\"caret-color: rgb(255, 42, 0);\"\u003ehandling\u003c\/span\u003e. \u003c\/span\u003e\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003e1) Chlorine Measurement Range: 0.00 ~ 20.00mg \/ L\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003e2) Resolution: 0.01mg \/ L\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003e3) Accuracy: 1% F.S.\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003e4) Temperature compensation: -10.0 ~ 110.0 ℃\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003e5) SS316 housing, platinum sensor, three-electrode method\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003e6) PG13.5 thread, easy to install on site\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003e7) 2 power lines, 2 RS-485 signal lines\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003e8) 24VDC power supply, power supply fluctuation range ± 10%, 2000V isolation\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003eDownloads\u003c\/h4\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cstrong\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/860031-33-i.pdf?v=1598908093\" target=\"_blank\"\u003e \u003c\/a\u003e\u003ca rel=\"noopener\" title=\"Inline Digital Residual Chlorine Sensor - Users Manual\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/870001-CL_Residual_Chlorine_Sensor_Users_Manual.pdf\" target=\"_blank\"\u003e\u003cimg alt=\"PDF\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/pdf-icon-63x63_480x480.png?v=1598991821\" style=\"float: left;\"\u003e \u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/860031-33-i.pdf?v=1598908093\" target=\"_blank\"\u003e\u003cbr\u003e\u003c\/a\u003e\u003ca rel=\"noopener\" title=\"Inline Digital Residual Chlorine Sensor - Users Manual\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/870001-CL_Residual_Chlorine_Sensor_Users_Manual.pdf\" target=\"_blank\"\u003eInstruction Manual\u003c\/a\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e","brand":"Sper Scientific","offers":[{"title":"Default Title","offer_id":46246434439392,"sku":"870001-CL","price":1591.85,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/inline-digital-residual-chlorine-sensor-870001-cl-801429.jpg?v=1752691875"},{"product_id":"ultrasonic-level-meter","title":"Integrated Ultrasonic Level Meter","description":"\u003ch1\u003eThe Ultrasonic Level Meter combines the strengths of various level measurement instruments into a fully digital and user-friendly system.\u003c\/h1\u003e\n\u003cp\u003eIt offers reliable level monitoring, seamless data transmission, and intuitive human-machine interaction. With robust anti-interference capabilities, customizable upper and lower limits, and online output adjustments, it supports on-site display and multiple output options, including analog, switching and RS485 for easy integration with control systems. \u003c\/p\u003e\n\u003cp\u003eConstructed with a waterproof engineering plastic cover and ABS probe, it suits diverse level measurement applications. Additional modules like RS485 and current output can be added for enhanced compatibility with PLCs. Key features include wide DC12-24V voltage range, parameter backup and recovery, flexible analog output adjustment, filter settings to eliminate noise, customizable serial data formats, and adjustable pulse intensity for measuring air gaps or liquid levels.\u003c\/p\u003e\n\u003cp class=\"p1\"\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli class=\"p1\"\u003eDC12-24V wide work voltage\u003c\/li\u003e\n\u003cli class=\"p1\"\u003eBackup and recovery parameter set\u003c\/li\u003e\n\u003cli class=\"p1\"\u003eFree adjustment of the range of analog output\u003c\/li\u003e\n\u003cli class=\"p1\"\u003eSet a filter value to remove\u003c\/li\u003e\n\u003cli class=\"p1\"\u003eCustom serial port data format\u003c\/li\u003e\n\u003cli class=\"p1\"\u003eMeasure measure air space or liquid level\u003c\/li\u003e\n\u003cli class=\"p1\"\u003e1-15 transmitted pulse intensity depending on working conditions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003eOrdering Notes:\u003cbr\u003e\u003c\/b\u003e\u003cb\u003e\u003cspan\u003e\u003cspan style=\"color: #ff2a00;\"\u003eAll Inline Water Quality Meters and Sensors ship direct from the factory. Please allow 10-15 business days for shipping and \u003cspan style=\"caret-color: rgb(255, 42, 0);\"\u003ehandling\u003c\/span\u003e. \u003c\/span\u003e\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable style=\"border-collapse: collapse; width: 654pt; box-sizing: border-box; outline: 0px; border-spacing: 0px; font-variant-ligatures: normal; font-variant-caps: normal; orphans: 2; widows: 2; -webkit-text-stroke-width: 0px; text-decoration-thickness: initial; text-decoration-style: initial; text-decoration-color: initial; height: 301px;\" width=\"872\" cellspacing=\"0\" cellpadding=\"0\" border=\"0\"\u003e\n\u003ccolgroup\u003e \u003ccol style=\"width: 296px;\" width=\"296\"\u003e \u003ccol style=\"width: 575px;\" width=\"576\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 24px; box-sizing: border-box; outline: 0px;\" height=\"24\"\u003e\n\u003ctd style=\"height: 24px; width: 222pt; box-sizing: border-box; outline: 0px;\" width=\"296\" class=\"xl63\" height=\"24\"\u003e\u003cspan style=\"box-sizing: border-box; outline: 0px;\"\u003eRange\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 432pt; box-sizing: border-box; outline: 0px; height: 24px;\" width=\"576\" class=\"xl63\"\u003e\u003cspan style=\"box-sizing: border-box; outline: 0px;\"\u003e5, 8, 10, 12, 15m\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 13px;\"\u003e\n\u003ctd style=\"box-sizing: border-box; outline: 0px; height: 13px;\"\u003e\u003cspan style=\"box-sizing: border-box; outline: 0px; height: 13px;\"\u003eAccuracy\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"box-sizing: border-box; outline: 0px; height: 13px;\"\u003e±0.3%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 24px; box-sizing: border-box; outline: 0px;\" height=\"24\"\u003e\n\u003ctd style=\"height: 24px; box-sizing: border-box; outline: 0px;\" class=\"xl63\" height=\"24\"\u003e\u003cspan style=\"box-sizing: border-box; outline: 0px;\"\u003eBlind Zone\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"box-sizing: border-box; outline: 0px; height: 24px;\" class=\"xl64\"\u003e\u003cspan style=\"box-sizing: border-box; outline: 0px;\"\u003e＜\u003cspan class=\"font5\"\u003e0.3-0.5m (different for range)\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 24px; box-sizing: border-box; outline: 0px;\" height=\"24\"\u003e\n\u003ctd style=\"height: 24px; box-sizing: border-box; outline: 0px;\" class=\"xl63\" height=\"24\"\u003e\u003cspan style=\"box-sizing: border-box; outline: 0px;\"\u003eDisplay resolution\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"box-sizing: border-box; outline: 0px; height: 24px;\" class=\"xl63\"\u003e\u003cspan style=\"box-sizing: border-box; outline: 0px;\"\u003e1mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 24px; box-sizing: border-box; outline: 0px;\" height=\"24\"\u003e\n\u003ctd style=\"height: 24px; box-sizing: border-box; outline: 0px;\" class=\"xl63\" height=\"24\"\u003e\u003cspan style=\"box-sizing: border-box; outline: 0px;\"\u003eFrequency\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"box-sizing: border-box; outline: 0px; height: 24px;\" class=\"xl63\"\u003e\u003cspan style=\"box-sizing: border-box; outline: 0px;\"\u003e20~350KHz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 24px; box-sizing: border-box; outline: 0px;\" height=\"24\"\u003e\n\u003ctd style=\"height: 24px; box-sizing: border-box; outline: 0px;\" class=\"xl63\" height=\"24\"\u003e\u003cspan style=\"box-sizing: border-box; outline: 0px;\"\u003ePower\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"box-sizing: border-box; outline: 0px; height: 24px;\" class=\"xl63\"\u003e\u003cspan style=\"box-sizing: border-box; outline: 0px;\"\u003e12-24VDC; consumption:\u0026lt;1.5W\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 24px; box-sizing: border-box; outline: 0px;\" height=\"24\"\u003e\n\u003ctd style=\"height: 24px; box-sizing: border-box; outline: 0px;\" class=\"xl63\" height=\"24\"\u003e\u003cspan style=\"box-sizing: border-box; outline: 0px;\"\u003eOutput\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"box-sizing: border-box; outline: 0px; height: 24px;\" class=\"xl63\"\u003e\u003cspan style=\"box-sizing: border-box; outline: 0px;\"\u003e4~20mA RL\u0026gt;600\u003cspan class=\"font6\"\u003eΩ\u003c\/span\u003e\u003cspan class=\"font5\"\u003e(standard),1~5V\\1~10V\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 24px; box-sizing: border-box; outline: 0px;\" height=\"24\"\u003e\n\u003ctd style=\"height: 24px; box-sizing: border-box; outline: 0px;\" class=\"xl63\" height=\"24\"\u003e\u003cspan style=\"box-sizing: border-box; outline: 0px;\"\u003eCommunication\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"box-sizing: border-box; outline: 0px; height: 24px;\" class=\"xl63\"\u003e\u003cspan style=\"box-sizing: border-box; outline: 0px;\"\u003eRS485\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 24px; box-sizing: border-box; outline: 0px;\" height=\"24\"\u003e\n\u003ctd style=\"height: 24px; box-sizing: border-box; outline: 0px;\" class=\"xl63\" height=\"24\"\u003e\u003cspan style=\"box-sizing: border-box; outline: 0px;\"\u003eRelay\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"box-sizing: border-box; outline: 0px; height: 24px;\" class=\"xl63\"\u003e\u003cspan style=\"box-sizing: border-box; outline: 0px;\"\u003e2 NPN relays (AC: 5A 250V DC: 10A 24V)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 24px; box-sizing: border-box; outline: 0px;\" height=\"24\"\u003e\n\u003ctd style=\"height: 24px; box-sizing: border-box; outline: 0px;\" class=\"xl63\" height=\"24\"\u003e\u003cspan style=\"box-sizing: border-box; outline: 0px;\"\u003eMaterial\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"box-sizing: border-box; outline: 0px; height: 24px;\" class=\"xl63\"\u003e\u003cspan style=\"box-sizing: border-box; outline: 0px;\"\u003eABS\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 24px; box-sizing: border-box; outline: 0px;\" height=\"24\"\u003e\n\u003ctd style=\"height: 24px; box-sizing: border-box; outline: 0px;\" class=\"xl63\" height=\"24\"\u003e\u003cspan style=\"box-sizing: border-box; outline: 0px;\"\u003eDimension\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"box-sizing: border-box; outline: 0px; height: 24px;\" class=\"xl64\"\u003e\u003cspan style=\"box-sizing: border-box; outline: 0px;\"\u003eΦ\u003cspan class=\"font5\"\u003e92mm \u003c\/span\u003e\u003cspan class=\"font6\"\u003e× \u003c\/span\u003e\u003cspan class=\"font5\"\u003e198mm \u003c\/span\u003e\u003cspan class=\"font6\"\u003e× \u003c\/span\u003e\u003cspan class=\"font5\"\u003eM60\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 24px; box-sizing: border-box; outline: 0px;\" height=\"24\"\u003e\n\u003ctd style=\"height: 24px; box-sizing: border-box; outline: 0px;\" class=\"xl63\" height=\"24\"\u003e\u003cspan style=\"box-sizing: border-box; outline: 0px;\"\u003eProtection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"box-sizing: border-box; outline: 0px; height: 24px;\" class=\"xl63\"\u003e\u003cspan style=\"box-sizing: border-box; outline: 0px;\"\u003eIP65 (others optional)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 24px; box-sizing: border-box; outline: 0px;\" height=\"24\"\u003e\n\u003ctd style=\"height: 24px; box-sizing: border-box; outline: 0px;\" class=\"xl63\" height=\"24\"\u003e\u003cspan style=\"box-sizing: border-box; outline: 0px;\"\u003eConnection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"box-sizing: border-box; outline: 0px; height: 24px;\" class=\"xl63\"\u003e\u003cspan style=\"box-sizing: border-box; outline: 0px;\"\u003eElectrical interface: M20X1.5, Installation: M60X2 or ￠61MM\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Sper Scientific","offers":[{"title":"Default Title","offer_id":46246435094752,"sku":"870010","price":568.1,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/integrated-ultrasonic-level-meter-870010-7414059.jpg?v=1760646507"},{"product_id":"inline-residual-chlorine-analyzer","title":"Online Residual Chlorine Analyzer","description":"\u003cp\u003e\u003cb\u003eOrdering Notes:\u003cbr\u003e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003e1. \u003c\/span\u003e\u003c\/b\u003e\u003cb\u003e\u003cspan\u003e\u003cspan style=\"color: #ff2a00;\"\u003eAll Inline Water Quality Meters and Sensors ship direct from the factory. Please allow 10-15 business days for shipping and \u003cspan style=\"caret-color: rgb(255, 42, 0);\"\u003ehandling\u003c\/span\u003e. \u003c\/span\u003e\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003e\u003cstrong\u003eOnline Residual Chlorine Meter\u003c\/strong\u003e\u003c\/h1\u003e\n\u003cp\u003eThe Online Residual Chlorine Meter seamlessly integrates a digital residual chlorine sensor, flow cell, piping, and valve into a single unit. This unified system allows for centralized monitoring and management via a controller. It combines online water quality analysis, database management, and calibration functions, making chlorine data collection and analysis straightforward and efficient.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eContinuous monitoring of residual chlorine in clean water\u003c\/li\u003e\n\u003cli\u003eChlorine monitoring in swimming pools\u003c\/li\u003e\n\u003cli\u003eMeasurement of chlorine in food and beverage water\u003c\/li\u003e\n\u003cli\u003ePotable water quality assessment\u003c\/li\u003e\n\u003cli\u003eProcess liquid monitoring\u003c\/li\u003e\n\u003cli\u003eEvaluation of treated process water\u003c\/li\u003e\n\u003cli\u003eMonitoring of pipe networks and secondary water supplies\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan\u003e\u003cstrong\u003ePlug and Play\u003c\/strong\u003e\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003eWith precision digital residual chlorine sensor (included)\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003e\u003cstrong\u003eBubble Rejection System\u003c\/strong\u003e\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003eClassic flow cell design\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003e\u003cstrong\u003eAutomatic Drain Function\u003c\/strong\u003e\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003eLess manual maintenance\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWide Power Range\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003e85V AC ~ 265V AC\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAnti-\u003cmeta charset=\"utf-8\"\u003eElectromagnetic Interface\u003cbr\u003e\u003c\/strong\u003e\u003cspan\u003eAnti-electromagnetic interference and surge protection\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003e\u003cstrong\u003ePower Off Protection Function\u003c\/strong\u003e\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003eSaves measurement data completely on power disruption\u003c\/span\u003e\u003cb\u003e\u003c\/b\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable class=\"table table-bordered table-hover\" style=\"width: 79.0698%; height: 775px;\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"firstRow\" style=\"height: 19.5938px;\"\u003e\n\u003ctd rowspan=\"1\" colspan=\"1\" style=\"width: 37.5303%; height: 19.5938px;\"\u003e\u003cstrong\u003eProduct\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd rowspan=\"1\" colspan=\"1\" style=\"width: 61.8305%; height: 19.5938px;\"\u003e\u003cstrong\u003eInline Residual Chlorine Meter\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd rowspan=\"1\" colspan=\"1\" style=\"width: 37.5303%; height: 19.5938px;\"\u003e\u003cstrong\u003eMeasured Parameters\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd rowspan=\"1\" colspan=\"1\" style=\"width: 61.8305%; height: 19.5938px;\"\u003eResidual Chlorine, Temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 106.781px;\"\u003e\n\u003ctd style=\"width: 37.5303%; height: 106.781px;\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eMeasuring Range\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 61.8305%; height: 106.781px;\"\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e0-60℃\u003c\/p\u003e\n\u003cp\u003e0-20 mg\/L (pH:5.5-10.5)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 71.1875px;\"\u003e\n\u003ctd rowspan=\"1\" colspan=\"1\" style=\"width: 37.5303%; height: 71.1875px;\"\u003e\u003cstrong\u003eUnit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd rowspan=\"1\" colspan=\"1\" style=\"width: 61.8305%; height: 71.1875px;\"\u003e\n\u003cp\u003eTurbidity: mg\/L\u003c\/p\u003e\n\u003cp\u003eTemperature: ℃\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 71.1875px;\"\u003e\n\u003ctd rowspan=\"1\" colspan=\"1\" style=\"width: 37.5303%; height: 71.1875px;\"\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd rowspan=\"1\" colspan=\"1\" style=\"width: 61.8305%; height: 71.1875px;\"\u003e\n\u003cp\u003e0.01 mg\/L\u003c\/p\u003e\n\u003cp\u003e0.1℃\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 71.1875px;\"\u003e\n\u003ctd style=\"width: 37.5303%; height: 71.1875px;\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eAccuracy\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 61.8305%; height: 71.1875px;\"\u003e\n\u003cp\u003e\u003cspan\u003eResidual chlorine: ±2% FS,\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eTemperature ±0.5℃\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.5938px;\"\u003e\n\u003ctd style=\"width: 37.5303%; height: 35.5938px;\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003ePower\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 61.8305%; height: 35.5938px;\"\u003e\n\u003cp\u003e\u003cspan\u003eAC 85-265V 50\/60Hz\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.5938px;\"\u003e\n\u003ctd style=\"width: 37.5303%; height: 35.5938px;\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eCurrent output\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 61.8305%; height: 35.5938px;\"\u003e\n\u003cp\u003e\u003cspan\u003e4-20mA\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.5938px;\"\u003e\n\u003ctd style=\"width: 37.5303%; height: 35.5938px;\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eCommunication \u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 61.8305%; height: 35.5938px;\"\u003e\n\u003cp\u003e\u003cspan\u003eRS485 Modbus RTU\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.5938px;\"\u003e\n\u003ctd style=\"width: 37.5303%; height: 35.5938px;\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eProtection \u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 61.8305%; height: 35.5938px;\"\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.5938px;\"\u003e\n\u003ctd style=\"width: 37.5303%; height: 35.5938px;\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eRelay\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 61.8305%; height: 35.5938px;\"\u003e2 relays, 5A\/250V AC      5A\/30V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd rowspan=\"1\" colspan=\"1\" style=\"width: 37.5303%; height: 19.5938px;\"\u003e\u003cstrong\u003eWireless\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd rowspan=\"1\" colspan=\"1\" style=\"width: 61.8305%; height: 19.5938px;\"\u003eOptional (for Mobile App and Website)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd rowspan=\"1\" colspan=\"1\" style=\"width: 37.5303%; height: 19.5938px;\"\u003e\u003cstrong\u003eFlow\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd rowspan=\"1\" colspan=\"1\" style=\"width: 61.8305%; height: 19.5938px;\"\u003e15L-30L\/H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.5938px;\"\u003e\n\u003ctd style=\"width: 37.5303%; height: 35.5938px;\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eOverall Dimensions\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 61.8305%; height: 35.5938px;\"\u003e600mm × 400mm × 230m（L×W×H)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.5938px;\"\u003e\n\u003ctd style=\"width: 37.5303%; height: 35.5938px;\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eInlet\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 61.8305%; height: 35.5938px;\"\u003e\n\u003cp\u003e\u003cspan\u003e6mm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.5938px;\"\u003e\n\u003ctd style=\"width: 37.5303%; height: 35.5938px;\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eOutlet\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 61.8305%; height: 35.5938px;\"\u003e\n\u003cp\u003e\u003cspan\u003e10mm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.5938px;\"\u003e\n\u003ctd style=\"width: 37.5303%; height: 35.5938px;\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eProtection\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 61.8305%; height: 35.5938px;\"\u003e\n\u003cp\u003e\u003cspan\u003eIP65\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003cmeta charset=\"utf-8\"\u003e\u003c\/p\u003e\n\u003ch4\u003eDownloads\u003c\/h4\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cstrong\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/860031-33-i.pdf?v=1598908093\" target=\"_blank\"\u003e \u003c\/a\u003e\u003ca rel=\"noopener\" title=\"Inline Residual Chlorine Meter - Users Manual\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/870008_Residual_Chlorine_Meter_Manual.pdf\" target=\"_blank\"\u003e\u003cimg style=\"float: left;\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/pdf-icon-63x63_480x480.png?v=1598991821\" alt=\"PDF\"\u003e \u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/860031-33-i.pdf?v=1598908093\" target=\"_blank\"\u003e\u003cbr\u003e\u003c\/a\u003e\u003ca rel=\"noopener\" title=\"Inline Residual Chlorine Meter - Users Manual\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/870008_Residual_Chlorine_Meter_Manual.pdf\" target=\"_blank\"\u003eInstruction Manual\u003c\/a\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Sper Scientific","offers":[{"title":"Default Title","offer_id":46246435127520,"sku":"870008","price":2229.15,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/inline-residual-chlorine-analyzer-870008-884501.jpg?v=1752691896"},{"product_id":"inline-industrial-conductivity-electrode","title":"Online Industrial Conductivity Electrode","description":"\u003ch1\u003eThe Industrial Conductivity Series electrodes are purpose-built for precise conductivity measurements in pure water, ultra-pure water and water treatment applications.\u003c\/h1\u003e\n\u003cp\u003eThese electrodes are especially suitable for use in thermal power plants and the water treatment industry, where durability and accuracy are critical. Featuring a robust double-cylinder structure made from titanium alloy, they naturally oxidize to form a chemically passive layer, enhancing resistance to various liquids (excluding hydrofluoric acid). Temperature compensation components are available in multiple options, including NTC2.252K, 2K, 10K, 20K, 30K, PT100, and PT1000, which can be specified based on user needs.\u003c\/p\u003e\n\u003cp\u003eThe K=10.0 or K=30 electrodes in this series incorporate a large-area platinum structure, providing excellent resistance to strong acids and alkalis as well as high anti-fouling capacity. These electrodes are well-suited for on-line conductivity measurement in demanding industries such as wastewater treatment and seawater purification.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDouble-cylinder structure with corrosion-resistant titanium alloy\u003c\/li\u003e\n\u003cli\u003eNaturally oxidized, chemically passive surface for improved durability\u003c\/li\u003e\n\u003cli\u003eMultiple temperature compensation options: NTC2.252K, 2K, 10K, 20K, 30K, PT100, PT1000\u003c\/li\u003e\n\u003cli\u003eLarge-area platinum structure on K=10.0 and K=30 models for resistance to strong acids and alkalis\u003c\/li\u003e\n\u003cli\u003eExcellent anti-fouling capacity, ideal for specialized industrial applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003eOrdering Notes: \u003cbr\u003e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003e1. All Sper Inline \u003ca href=\"https:\/\/sperdirect.com\/collections\/inline-water-quality-monitors-sensors\" title=\"Inline Water Quality Monitoring\"\u003eWater Quality Meters and Sensors\u003c\/a\u003e are sold separately - one of each is required for a complete system. \u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003e\u003cspan\u003e\u003cspan style=\"color: #ff2a00;\"\u003e2. All Inline Water Quality Meters and Sensors ship direct from the factory. Please allow 10-15 business days for shipping and \u003cspan style=\"caret-color: rgb(255, 42, 0);\"\u003ehandling\u003c\/span\u003e. \u003c\/span\u003e\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003ctable style=\"height: 245px;\" class=\"MsoNormalTable\" border=\"0\" cellspacing=\"0\" cellpadding=\"0\" width=\"715\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 35px;\"\u003e\n\u003ctd style=\"height: 35px;\" width=\"155\" nowrap\u003e\n\u003cp style=\"text-align: left;\" class=\"MsoNormal\" align=\"center\"\u003e\u003cb\u003e\u003cspan\u003eProbe\u003c\/span\u003e\u003c\/b\u003e\u003cb\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"112\" nowrap\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cb\u003e\u003cspan\u003e870003-ICE-01\u003c\/span\u003e\u003c\/b\u003e\u003cb\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"112\" nowrap\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cb\u003e\u003cspan\u003e870003-ICE-02\u003c\/span\u003e\u003c\/b\u003e\u003cb\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"112\" nowrap\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cb\u003e\u003cspan\u003e870003-ICE-03\u003c\/span\u003e\u003c\/b\u003e\u003cb\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"112\" nowrap\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cb\u003e\u003cspan\u003e870003-ICE-04\u003c\/span\u003e\u003c\/b\u003e\u003cb\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"112\" nowrap\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cb\u003e\u003cspan\u003e870003-ICE-05\u003c\/span\u003e\u003c\/b\u003e\u003cb\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35px;\"\u003e\n\u003ctd style=\"height: 35px;\" width=\"155\" nowrap\u003e\n\u003cp style=\"text-align: left;\" class=\"MsoNormal\" align=\"center\"\u003e\u003cb\u003e\u003cspan\u003eCC\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"112\" nowrap\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e0.01\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"112\" nowrap\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e0.1\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"112\" nowrap\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e1.0\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"112\" nowrap\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e10\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"112\" nowrap\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e30\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35px;\"\u003e\n\u003ctd style=\"height: 35px;\" width=\"155\" nowrap\u003e\n\u003cp style=\"text-align: left;\" class=\"MsoNormal\" align=\"center\"\u003e\u003cb\u003e\u003cspan\u003eEC Range\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"112\" nowrap\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e0-2μS\/cm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"112\" nowrap\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e0-200μS\/cm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"112\" nowrap\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e0-2000μS\/cm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"112\" nowrap\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e0-20000μS\/cm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"112\" nowrap\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e30-600mS\/cm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35px;\"\u003e\n\u003ctd style=\"height: 35px;\" width=\"155\" nowrap\u003e\n\u003cp style=\"text-align: left;\" class=\"MsoNormal\" align=\"center\"\u003e\u003cb\u003e\u003cspan\u003eTemp Range\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"112\" nowrap\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e0.0-100.0°C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"112\" nowrap\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e0.0-100.0°C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"112\" nowrap\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e0.0-100.0°C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"112\" nowrap\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e0.0-100.0°C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"112\" nowrap\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e0.0-100.0°C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35px;\"\u003e\n\u003ctd style=\"height: 35px;\" width=\"155\" nowrap\u003e\n\u003cp style=\"text-align: left;\" class=\"MsoNormal\" align=\"center\"\u003e\u003cb\u003e\u003cspan\u003eAccuracy\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"560\" nowrap colspan=\"5\"\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e2%, ±0.5°C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35px;\"\u003e\n\u003ctd style=\"height: 35px;\" width=\"155\" nowrap\u003e\n\u003cp style=\"text-align: left;\" class=\"MsoNormal\" align=\"center\"\u003e\u003cb\u003e\u003cspan\u003eWithstand pressure\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"560\" nowrap colspan=\"5\"\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e0.4MPa\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35px;\"\u003e\n\u003ctd style=\"height: 35px;\" width=\"155\" nowrap\u003e\n\u003cp style=\"text-align: left;\" class=\"MsoNormal\" align=\"center\"\u003e\u003cb\u003e\u003cspan\u003eWaterproof Level\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"560\" nowrap colspan=\"5\"\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003eIP68\/NEMA6P\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable border=\"0\" style=\"width: 100%; height: 430px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 38px;\"\u003e\n\u003ctd style=\"width: 21.721869%; height: 38px;\"\u003e\u003cspan\u003eConstant of electrode\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 28.232759%; height: 38px;\"\u003e\u003cspan\u003e0.1\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd rowspan=\"6\" style=\"width: 46.058303%; height: 430px;\"\u003e\u003cspan\u003e\u003cimg src=\"https:\/\/www.boquinstruments.com\/uploads\/DDG-0.1-Industrial-Conductivity-Sensor.jpg\" alt=\"DDG-0.1 Industrial Conductivity Sensor\" class=\"alignnone size-full wp-image-2585\"\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 38px;\"\u003e\n\u003ctd style=\"width: 21.721869%; height: 38px;\"\u003e\u003cspan\u003eCompressive strength\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 28.232759%; height: 38px;\"\u003e\u003cspan\u003e0.6 MPa\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 21.721869%; height: 19px;\"\u003e\u003cspan\u003eMeasuring range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 28.232759%; height: 19px;\"\u003e\u003cspan\u003e0-2000 uS\/em\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 38px;\"\u003e\n\u003ctd style=\"width: 21.721869%; height: 38px;\"\u003e\u003cspan\u003eConnection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 28.232759%; height: 38px;\"\u003e\u003cspan\u003e1\/2 or 3\/4 Thread Installation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 38px;\"\u003e\n\u003ctd style=\"width: 21.721869%; height: 38px;\"\u003e\u003cspan\u003eMaterial\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 28.232759%; height: 38px;\"\u003e\n\u003cspan\u003e316L Titanium Alloy \u003cbr\u003eand \u003c\/span\u003ePlatinum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 259px;\"\u003e\n\u003ctd style=\"width: 21.721869%; height: 259px;\"\u003e\u003cspan\u003eApplication\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 28.232759%; height: 259px;\"\u003e\u003cspan\u003eWater Treatment Industry\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4\u003eDownloads\u003c\/h4\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cstrong\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/860031-33-i.pdf?v=1598908093\" target=\"_blank\"\u003e \u003c\/a\u003e\u003ca rel=\"noopener\" title=\"Inline Industrial Conductivity Sensor - Users Manual\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/Inductive_Conductivity_Sensor_-_Users_Manual.pdf\" target=\"_blank\"\u003e\u003cimg style=\"float: left;\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/pdf-icon-63x63_480x480.png?v=1598991821\" alt=\"PDF\"\u003e \u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/860031-33-i.pdf?v=1598908093\" target=\"_blank\"\u003e\u003cbr\u003e\u003c\/a\u003e\u003ca rel=\"noopener\" title=\"Inline Industrial Conductivity Sensor - Users Manual\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/Inductive_Conductivity_Sensor_-_Users_Manual.pdf\" target=\"_blank\"\u003eInstruction Manual\u003c\/a\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e","brand":"Sper Scientific","offers":[{"title":"870003-ICE-01","offer_id":52569194791136,"sku":"870003-ICE-01","price":170.89,"currency_code":"USD","in_stock":true},{"title":"870003-ICE-02","offer_id":52569194823904,"sku":"870003-ICE-02","price":170.89,"currency_code":"USD","in_stock":true},{"title":"870003-ICE-03","offer_id":52569194856672,"sku":"870003-ICE-03","price":170.89,"currency_code":"USD","in_stock":true},{"title":"870003-ICE-04","offer_id":52569194889440,"sku":"870003-ICE-04","price":170.89,"currency_code":"USD","in_stock":true},{"title":"870003-ICE-05","offer_id":52569194922208,"sku":"870003-ICE-05","price":170.89,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/inline-industrial-conductivity-electrode-870003-ice-994131.jpg?v=1752691912"},{"product_id":"industrial-conductivity-tds-salinity-resistivity-meter","title":"Online Industrial Conductivity, TDS, Salinity, Resistivity Meter","description":"\u003cp\u003e\u003cb\u003eOrdering Notes:\u003cbr\u003e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003e1. ALL SPER ONLINE WATER QUALITY METERS AND SENSORS ARE SOLD SEPARATELY - Please be sure to add the appropriate sensor (listed above) when purchasing your meter - ONE METER AND SENSOR are required for a complete system. \u003c\/span\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003e\u003cspan\u003e\u003cspan style=\"color: #ff2a00;\"\u003e2. All Inline Water Quality Meters and Sensors ship direct from the factory. Please allow 10-15 business days for shipping and \u003cspan style=\"caret-color: rgb(255, 42, 0);\"\u003ehandling\u003c\/span\u003e. \u003c\/span\u003e\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eOur Industrial Conductivity, TDS, Salinity and Resistance Meter is essential for inline monitoring of water conductivity in applications like drinking water treatment, industrial water and boiler water.\u003c\/h1\u003e\n\u003cp\u003eConductivity measurements provide valuable insight into the amount of dissolved material in water. We offer a wide range of high-quality, affordable conductivity sensors, suitable for everything from deionized water to highly saturated brines. \u003c\/p\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cspan\u003eWhy is conductivity measurement important in water treatment? The conductivity of water is crucial because it gives an indication of the amount of dissolved material within that water. \u003cmeta charset=\"utf-8\"\u003ePaired with Sper Scientific conductivity controllers, this meter delivers reliable, cost-effective process control across industries.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMulti-functional: Measures conductivity, TDS, resistivity, salinity, and temperature\u003c\/li\u003e\n\u003cli\u003eReliable conductivity monitoring for consistent results\u003c\/li\u003e\n\u003cli\u003eEasy system integration for seamless conductivity measurement\u003c\/li\u003e\n\u003cli\u003eIdeal for all water quality environments\u003c\/li\u003e\n\u003cli\u003eCompatible with contact conductivity sensors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable class=\"table table-bordered table-hover\" data-sort=\"sortDisabled\" style=\"width: 70.766488%;\" height=\"750\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd width=\"220\" style=\"width: 40.929401%;\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd rowspan=\"1\" colspan=\"2\" width=\"97\" style=\"width: 57.829181%;\"\u003e\n\u003cp\u003e\u003cstrong\u003eInline Conductivity Meter\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"220\" style=\"width: 40.929401%;\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eMeasurement\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd rowspan=\"1\" colspan=\"2\" width=\"97\" style=\"width: 57.829181%;\"\u003e\u003cspan\u003eConductivity, TDS, Resistivity, Salinity, Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"220\" style=\"width: 40.929401%;\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd rowspan=\"1\" colspan=\"2\" width=\"97\" style=\"width: 57.829181%;\"\u003e\n\u003cp\u003e0.00uS\/cm~2000000.00 uS\/cm(0.00uS\/cm~2000.00 mS\/cm)\u003c\/p\u003e\n\u003cp\u003e0.00g\/L~80.00 g\/L (ppt)\u003c\/p\u003e\n\u003cp\u003e0.00mg\/L~130000.00 mg\/L (ppm)\u003c\/p\u003e\n\u003cp\u003e0.00MΩ~20.00MΩ\u003c\/p\u003e\n\u003cp\u003e-40.0℃~200.0℃ (refer to matching electrode)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"1\" colspan=\"1\" width=\"220\" style=\"width: 40.929401%;\"\u003e\u003cspan\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd rowspan=\"1\" colspan=\"2\" width=\"97\" style=\"width: 57.829181%;\"\u003e\u003cspan\u003e1%,  ±0.2℃\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"220\" style=\"width: 40.929401%;\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eHousing Material\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\" width=\"97\" style=\"width: 57.829181%;\"\u003e\n\u003cp\u003e\u003cspan\u003eABS Flame retardant : V0\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"220\" style=\"width: 40.929401%;\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003ePower\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\" width=\"97\" style=\"width: 57.829181%;\"\u003e\n\u003cp\u003e\u003cspan\u003e90 – 260V AC 50\/60Hz\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"220\" style=\"width: 40.929401%;\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eConsumption\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\" width=\"97\" style=\"width: 57.829181%;\"\u003e\n\u003cp\u003e\u003cspan\u003e4W\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"220\" style=\"width: 40.929401%;\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOutput\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\" width=\"97\" style=\"width: 57.829181%;\"\u003e\n\u003cp\u003e\u003cspan\u003eTwo ways 4-20mA output\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\" width=\"220\" style=\"width: 40.929401%;\"\u003e\u003cspan\u003e\u003cstrong\u003eCommunication\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" rowspan=\"1\" width=\"97\" style=\"width: 57.829181%;\"\u003e\u003cspan\u003eRS485 Modbus\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"220\" style=\"width: 40.929401%;\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eRelay\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\" width=\"97\" style=\"width: 57.829181%;\"\u003e\n\u003cp\u003e\u003cspan\u003eTwo relays: 5A\/250V AC, 5A\/30V DC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"220\" style=\"width: 40.929401%;\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eTemperature.Comp\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\" width=\"97\" style=\"width: 57.829181%;\"\u003e\n\u003cp\u003e\u003cspan\u003ePT1000 \/ NTC10K\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\" width=\"79\" style=\"width: 40.929401%;\"\u003e\u003cstrong\u003eDimension\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" rowspan=\"1\" width=\"97\" style=\"width: 57.829181%;\"\u003e\u003cspan\u003e144×144×104mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\" width=\"79\" style=\"width: 40.929401%;\"\u003e\u003cstrong\u003eHole size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" rowspan=\"1\" width=\"97\" style=\"width: 57.829181%;\"\u003e138*138mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"220\" style=\"width: 40.929401%;\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProtection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\" width=\"97\" style=\"width: 57.829181%; text-align: left;\"\u003e\u003cspan\u003eIP65\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"220\" style=\"width: 40.929401%;\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eData Logger\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\" rowspan=\"1\" width=\"97\" style=\"width: 57.829181%;\"\u003e\u003cspan\u003e1,000 times\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"220\" style=\"width: 40.929401%;\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eLanguage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\" width=\"97\" style=\"width: 57.829181%;\"\u003e\n\u003cp\u003e\u003cspan\u003eEnglish \/ 简体中文\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"220\" style=\"width: 40.929401%;\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eInstallation\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\" width=\"97\" style=\"width: 57.829181%;\"\u003e\n\u003cp\u003e\u003cspan\u003ePanel \/ Wall \/ Pipe mounted\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable style=\"height: 245px;\" class=\"MsoNormalTable\" border=\"0\" cellspacing=\"0\" cellpadding=\"0\" width=\"715\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 35px;\"\u003e\n\u003ctd style=\"height: 35px;\" width=\"155\" nowrap\u003e\n\u003cp style=\"text-align: left;\" class=\"MsoNormal\" align=\"center\"\u003e\u003cb\u003e\u003cspan\u003eProbe\u003c\/span\u003e\u003c\/b\u003e\u003cb\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"112\" nowrap\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cb\u003e\u003cspan\u003e870003-ICE-01\u003c\/span\u003e\u003c\/b\u003e\u003cb\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"112\" nowrap\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cb\u003e\u003cspan\u003e870003-ICE-02\u003c\/span\u003e\u003c\/b\u003e\u003cb\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"112\" nowrap\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cb\u003e\u003cspan\u003e870003-ICE-03\u003c\/span\u003e\u003c\/b\u003e\u003cb\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"112\" nowrap\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cb\u003e\u003cspan\u003e870003-ICE-04\u003c\/span\u003e\u003c\/b\u003e\u003cb\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"112\" nowrap\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cb\u003e\u003cspan\u003e870003-ICE-05\u003c\/span\u003e\u003c\/b\u003e\u003cb\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35px;\"\u003e\n\u003ctd style=\"height: 35px;\" width=\"155\" nowrap\u003e\n\u003cp style=\"text-align: left;\" class=\"MsoNormal\" align=\"center\"\u003e\u003cb\u003e\u003cspan\u003eCC\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"112\" nowrap\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e0.01\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"112\" nowrap\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e0.1\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"112\" nowrap\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e1.0\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"112\" nowrap\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e10\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"112\" nowrap\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e30\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35px;\"\u003e\n\u003ctd style=\"height: 35px;\" width=\"155\" nowrap\u003e\n\u003cp style=\"text-align: left;\" class=\"MsoNormal\" align=\"center\"\u003e\u003cb\u003e\u003cspan\u003eEC Range\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"112\" nowrap\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e0-2μS\/cm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"112\" nowrap\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e0-200μS\/cm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"112\" nowrap\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e0-2000μS\/cm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"112\" nowrap\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e0-20000μS\/cm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"112\" nowrap\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e30-600mS\/cm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35px;\"\u003e\n\u003ctd style=\"height: 35px;\" width=\"155\" nowrap\u003e\n\u003cp style=\"text-align: left;\" class=\"MsoNormal\" align=\"center\"\u003e\u003cb\u003e\u003cspan\u003eTemp Range\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"112\" nowrap\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e0.0-100.0°C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"112\" nowrap\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e0.0-100.0°C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"112\" nowrap\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e0.0-100.0°C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"112\" nowrap\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e0.0-100.0°C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"112\" nowrap\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e0.0-100.0°C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35px;\"\u003e\n\u003ctd style=\"height: 35px;\" width=\"155\" nowrap\u003e\n\u003cp style=\"text-align: left;\" class=\"MsoNormal\" align=\"center\"\u003e\u003cb\u003e\u003cspan\u003eAccuracy\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"560\" nowrap colspan=\"5\"\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e2%, ±0.5°C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35px;\"\u003e\n\u003ctd style=\"height: 35px;\" width=\"155\" nowrap\u003e\n\u003cp style=\"text-align: left;\" class=\"MsoNormal\" align=\"center\"\u003e\u003cb\u003e\u003cspan\u003eWithstand pressure\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"560\" nowrap colspan=\"5\"\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e0.4MPa\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35px;\"\u003e\n\u003ctd style=\"height: 35px;\" width=\"155\" nowrap\u003e\n\u003cp style=\"text-align: left;\" class=\"MsoNormal\" align=\"center\"\u003e\u003cb\u003e\u003cspan\u003eWaterproof Level\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"560\" nowrap colspan=\"5\"\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003eIP68\/NEMA6P\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eDownloads\u003c\/h4\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cstrong\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/860031-33-i.pdf\" target=\"_blank\"\u003e \u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/870003_Conductivity_Meter_Manual.pdf\" title=\"Inline Conductivity Meter - Users Manual\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg alt=\"PDF\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/pdf-icon-63x63_480x480.png\" style=\"float: left;\"\u003e\u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/860031-33-i.pdf\" target=\"_blank\"\u003e\u003cbr\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/870003_Conductivity_Meter_Manual.pdf\" title=\"Inline Conductivity Meter - Users Manual\"\u003eInstruction Manual\u003c\/a\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Sper Scientific","offers":[{"title":"Default Title","offer_id":46246435225824,"sku":"870003","price":722.98,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/industrial-conductivity-tds-salinity-resistivity-meter-870003-600932.jpg?v=1752691869"},{"product_id":"conductivity-sensor","title":"Online Digital Graphite Conductivity Sensor","description":"\u003ch1\u003eOur latest Inline Digital Graphite Conductivity Sensor, designed with advanced features for easy remote setup and calibration. \u003cspan class=\"s1\"\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/span\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/span\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/span\u003e\n\u003c\/h1\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/multi-parameter-inline-water-quality-analyzer-870001-820665_100x100.jpg?v=1730508960\" alt=\"Multi-Parameter Water Quality Analyzer\" style=\"margin-right: 16px; margin-bottom: 16px; float: left;\"\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003e\u003cbr\u003eThis sensor is only for use with: \u003cbr\u003e\u003c\/b\u003e\u003c\/span\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003e\u003ca href=\"https:\/\/sperdirect.com\/collections\/inline-water-quality-monitors-sensors\/products\/multi-parameter-analyzer\" title=\"Multi-parameter-analyzer\"\u003eSper Scientific 870001 \u003cspan\u003eMulti-Parameter Water Quality Analyzer\u003c\/span\u003e\u003c\/a\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003eThis sensor provides a user-friendly experience and is versatile, making it ideal for monitoring conductivity across multiple industries, including thermal power, fertilizers, metallurgy, environmental protection, pharmaceuticals, biochemistry, food processing, fermentation, brewing and water treatment.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLightweight design for easy installation\u003c\/li\u003e\n\u003cli\u003eHigh-quality electrode ensuring precise measurements and responsive performance\u003c\/li\u003e\n\u003cli\u003eIntegrated temperature probe for real-time temperature compensation\u003c\/li\u003e\n\u003cli\u003eStrong anti-interference capabilities and durable, long-lasting construction\u003c\/li\u003e\n\u003cli\u003eApplications: thermal power, chemical fertilizers, metallurgy, environmental protection and pharmaceuticals\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003eOrdering Notes: \u003cbr\u003e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003e1. All Sper Inline \u003ca title=\"Inline Water Quality Monitoring\" href=\"https:\/\/sperdirect.com\/collections\/inline-water-quality-monitors-sensors\"\u003eWater Quality Meters and Sensors\u003c\/a\u003e are sold separately - one of each is required for a complete system. \u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003e\u003cspan\u003e\u003cspan style=\"color: #ff2a00;\"\u003e2. All Inline Water Quality Meters and Sensors ship direct from the factory. Please allow 10-15 business days for shipping and \u003cspan style=\"caret-color: rgb(255, 42, 0);\"\u003ehandling\u003c\/span\u003e. \u003c\/span\u003e\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003cdiv class=\"unit-detail-html-tabs__content-attr\"\u003e\n\u003cdiv class=\"unit-product-attrparam\"\u003e\n\u003cdiv class=\"unit-product-attrparam__items row\"\u003e\n\u003cdiv class=\"col-12 col-md-6\"\u003e\n\u003cdiv class=\"unit-product-attrparam__item\"\u003e\n\u003cdiv class=\"unit-product-attrparam__label\"\u003e\n\u003ctable style=\"width: 94.010889%; height: 323px;\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 65.310078%; height: 19px;\"\u003e\n\u003cdiv class=\"unit-product-attrparam__label\"\u003eProtection Grade\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 33.527132%; height: 19px;\"\u003e\u003cspan\u003eIP68\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 65.310078%; height: 19px;\"\u003e\n\u003cdiv class=\"unit-product-attrparam__label\"\u003eMeasurement Range\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 33.527132%;\"\u003e\u003cspan\u003e0~5000us\/cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 38px;\"\u003e\n\u003ctd style=\"width: 65.310078%; height: 38px;\"\u003e\n\u003cdiv class=\"unit-product-attrparam__label\"\u003eConductivity Range\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 33.527132%; height: 38px;\"\u003e\u003cspan\u003e0~20000us\/cm (20ms\/cm)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 65.310078%; height: 19px;\"\u003e\n\u003cdiv class=\"col-12 col-md-6\"\u003e\n\u003cdiv class=\"unit-product-attrparam__item\"\u003e\n\u003cdiv class=\"unit-product-attrparam__label\"\u003eTemperature Range\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 33.527132%; height: 19px;\"\u003e\u003cspan\u003e0~65℃\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 65.310078%; height: 19px;\"\u003e\n\u003cspan style=\"font-size: 0.875rem;\"\u003eHousing Material\u003c\/span\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 33.527132%; height: 19px;\"\u003e\u003cspan\u003eSS316 Stainless Steel\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 65.310078%; height: 19px;\"\u003e\n\u003cdiv class=\"col-12 col-md-6\"\u003e\n\u003cdiv class=\"unit-product-attrparam__item\"\u003e\n\u003cdiv class=\"unit-product-attrparam__label\"\u003eResolution\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 33.527132%; height: 19px;\"\u003e\u003cspan\u003e1us\/cm 0.1℃\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 65.310078%; height: 19px;\"\u003e\n\u003cdiv class=\"unit-product-attrparam__label\"\u003eAccuracy\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 33.527132%; height: 19px;\"\u003e\u003cspan\u003e±2% ±0.5℃\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 65.310078%; height: 19px;\"\u003e\n\u003cdiv class=\"unit-product-attrparam__label\"\u003eCommunication\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 33.527132%; height: 19px;\"\u003e\u003cspan\u003eRS485 Modbus\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 38px;\"\u003e\n\u003ctd style=\"width: 65.310078%; height: 19px;\"\u003e\n\u003cdiv class=\"unit-product-attrparam__label\"\u003ePower\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 33.527132%; height: 19px;\"\u003e\u003cspan\u003e9~36V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"unit-detail-html-tabs__content-html\"\u003e\n\u003cdiv class=\"\" id=\"module-qqqcBxNP0fy3k\"\u003e\n\u003cdiv id=\"grid-QjVuhqNY4On4ZI0\" class=\"ce-d-flex ce-flex-wrap container\"\u003e\n\u003cdiv id=\"cell-DuuOQqDvLINsIbw\" class=\"ce-col-12 ce-col-md-6 ce-col-xl-6\"\u003e\n\u003cdiv id=\"unit-iGiRBN7fOQ2qrnG\" type=\"text\"\u003e\n\u003cdiv class=\"ce-text_item\"\u003e\n\u003cdiv class=\"ce-text\"\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4\u003eDownloads\u003c\/h4\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cstrong\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/860031-33-i.pdf?v=1598908093\" target=\"_blank\"\u003e \u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/870001-CON_-User-manual.pdf?v=1792013279\" title=\"Inline Conductivity Sensor  - Users Manual\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg alt=\"PDF\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/pdf-icon-63x63_480x480.png?v=1598991821\" style=\"float: left;\"\u003e \u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/860031-33-i.pdf?v=1598908093\" target=\"_blank\"\u003e\u003cbr\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/870001-CON_-User-manual.pdf?v=1792013279\" title=\"Inline Conductivity Sensor - Users Manual\" rel=\"noopener\" target=\"_blank\"\u003eInstruction Manual\u003c\/a\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"Sper Scientific","offers":[{"title":"Default Title","offer_id":46246435651808,"sku":"870001-CON","price":650.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/inline-digital-graphite-conductivity-sensor-870001-con-939244.png?v=1752691865"},{"product_id":"inline-digital-orp-sensor","title":"Online Digital ORP Sensor","description":"\u003ch1\u003eInline D\u003cmeta charset=\"utf-8\"\u003eigital ORP Sensor is a lightweight, high-precision electrode designed for easy installation and reliable, long-term performance.\u003c\/h1\u003e\n\u003cp\u003eWith a built-in temperature probe, it provides instant temperature compensation, ensuring accuracy and responsiveness. This sensor is highly resistant to interference and can be connected with output cables up to 500 meters in length. It allows for remote setup and calibration, making it user-friendly and ideal for ORP monitoring in various industries, including thermal power, fertilizer, metallurgy, environmental protection, pharmaceuticals, biochemistry, food and tap water.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"text-align: right;\"\u003e\n\u003cli style=\"text-align: left;\"\u003eIndustrial-grade design suitable for long-term stable performance in sewage applications\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003eBuilt-in temperature sensor with real-time temperature compensation\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003eRS485 signal output with strong anti-interference, supporting cable lengths up to 500 meters\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003eStandard Modbus RTU (485) communication protocol\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003eRemote setup and calibration for easy operation and parameter adjustment\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003eCompatible with 24V DC or 12V DC power supply\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003eOrdering Notes: \u003cbr\u003e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003e1. All Sper Inline \u003ca title=\"Inline Water Quality Monitoring\" href=\"https:\/\/sperdirect.com\/collections\/inline-water-quality-monitors-sensors\"\u003eWater Quality Meters and Sensors\u003c\/a\u003e are sold separately - one of each is required for a complete system. \u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003e\u003cspan\u003e\u003cspan style=\"color: #ff2a00;\"\u003e2. All Inline Water Quality Meters and Sensors ship direct from the factory. Please allow 10-15 business days for shipping and \u003cspan style=\"caret-color: rgb(255, 42, 0);\"\u003ehandling\u003c\/span\u003e. \u003c\/span\u003e\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4 style=\"text-align: left;\"\u003eSpecifications\u003c\/h4\u003e\n\u003ctable style=\"width: 73.2062%; height: 593px;\" cellspacing=\"0\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 35.5938px;\"\u003e\n\u003ctd width=\"338\" valign=\"left\" style=\"width: 61.3169%; height: 35.5938px;\"\u003e\n\u003cp align=\"left\"\u003e\u003cstrong\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"561\" valign=\"left\" style=\"width: 38.6831%; height: 35.5938px;\"\u003e\n\u003cp align=\"left\"\u003e\u003cstrong\u003e870001-ORP\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.5938px;\"\u003e\n\u003ctd width=\"338\" valign=\"left\" style=\"width: 61.3169%; height: 35.5938px;\"\u003e\n\u003cp style=\"text-align: left;\" align=\"left\"\u003e\u003cstrong\u003e\u003cspan\u003eParameter Measurement\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"561\" valign=\"left\" style=\"width: 38.6831%; height: 35.5938px;\"\u003e\n\u003cp align=\"left\"\u003e\u003cspan\u003eORP, Temperature\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.5938px;\"\u003e\n\u003ctd width=\"338\" valign=\"left\" style=\"width: 61.3169%; height: 35.5938px;\"\u003e\n\u003cp style=\"text-align: left;\" align=\"left\"\u003e\u003cstrong\u003e\u003cspan\u003eMeasure Range\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"561\" valign=\"left\" style=\"width: 38.6831%; height: 35.5938px;\"\u003e\n\u003cp align=\"left\"\u003e\u003cspan\u003e-2000mv~+2000mv\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 55.1875px;\"\u003e\n\u003ctd width=\"338\" valign=\"left\" style=\"width: 61.3169%; height: 55.1875px;\"\u003e\n\u003cp align=\"left\"\u003e\u003cstrong\u003e\u003cspan\u003eAccuracy\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"561\" valign=\"left\" style=\"width: 38.6831%; height: 55.1875px;\"\u003e\n\u003cp align=\"left\"\u003e\u003cspan\u003eORP: ±0.1mv \u003cbr\u003e\u003c\/span\u003e\u003cspan\u003eTemperature: ±1ºF (0.5℃)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.5938px;\"\u003e\n\u003ctd width=\"338\" valign=\"left\" style=\"width: 61.3169%; height: 35.5938px;\"\u003e\n\u003cp style=\"text-align: left;\" align=\"left\"\u003e\u003cstrong\u003e\u003cspan\u003eResolution\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"561\" valign=\"left\" style=\"width: 38.6831%; height: 35.5938px;\"\u003e\n\u003cp align=\"left\"\u003e\u003cspan\u003e1mV \u003c\/span\u003e\u003cspan\u003eTemperature: 0.1℃\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 34.5938px;\"\u003e\n\u003ctd width=\"338\" valign=\"left\" style=\"width: 61.3169%; height: 34.5938px;\"\u003e\n\u003cp align=\"left\"\u003e\u003cstrong\u003e\u003cspan\u003ePower Supply\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"561\" valign=\"left\" style=\"width: 38.6831%; height: 34.5938px;\"\u003e\n\u003cp align=\"left\"\u003e\u003cspan\u003e24V DC \/ 12VDC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.5938px;\"\u003e\n\u003ctd width=\"338\" valign=\"left\" style=\"width: 61.3169%; height: 35.5938px;\"\u003e\n\u003cp style=\"text-align: left;\" align=\"center\"\u003e\u003cstrong\u003e\u003cspan\u003ePower Dissipation\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"561\" valign=\"left\" style=\"width: 38.6831%; height: 35.5938px;\"\u003e\n\u003cp style=\"text-align: left;\" align=\"center\"\u003e\u003cspan\u003e1W\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.5938px;\"\u003e\n\u003ctd width=\"338\" valign=\"left\" style=\"width: 61.3169%; height: 35.5938px;\"\u003e\n\u003cp align=\"left\"\u003e\u003cstrong\u003e\u003cspan\u003eCommunication Mode\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"561\" valign=\"left\" style=\"width: 38.6831%; height: 35.5938px;\"\u003e\n\u003cp align=\"left\"\u003e\u003cspan\u003eRS485 (Modbus RTU)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 55.1875px;\"\u003e\n\u003ctd width=\"338\" valign=\"left\" style=\"width: 61.3169%; height: 55.1875px;\"\u003e\n\u003cp align=\"left\"\u003e\u003cstrong\u003e\u003cspan\u003eCable Length\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"561\" valign=\"left\" style=\"width: 38.6831%; height: 55.1875px;\"\u003e\n\u003cp align=\"left\"\u003e\u003cspan\u003eCan be ODM depend on user’s requirements\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 55.1875px;\"\u003e\n\u003ctd width=\"338\" valign=\"left\" style=\"width: 61.3169%; height: 55.1875px;\"\u003e\n\u003cp style=\"text-align: left;\" align=\"center\"\u003e\u003cstrong\u003e\u003cspan\u003eInstallation\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"561\" valign=\"left\" style=\"width: 38.6831%; height: 55.1875px;\"\u003e\n\u003cp align=\"left\"\u003e\u003cspan\u003eSinking type, pipeline, circulation type, etc.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.5938px;\"\u003e\n\u003ctd width=\"338\" valign=\"left\" style=\"width: 61.3169%; height: 35.5938px;\"\u003e\n\u003cp align=\"left\"\u003e\u003cstrong\u003e\u003cspan\u003eOverall Size\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"561\" valign=\"left\" style=\"width: 38.6831%; height: 35.5938px;\"\u003e\n\u003cp align=\"left\"\u003e\u003cspan\u003e9x1.2 inches\u003cbr\u003e(230mm×30mm)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.5938px;\"\u003e\n\u003ctd width=\"338\" valign=\"left\" style=\"width: 61.3169%; height: 35.5938px;\"\u003e\n\u003cp align=\"left\"\u003e\u003cstrong\u003e\u003cspan\u003eHousing Material\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"561\" valign=\"left\" style=\"width: 38.6831%; height: 35.5938px;\"\u003e\n\u003cp align=\"left\"\u003e\u003cspan\u003eABS\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eDownloads\u003c\/h4\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cstrong\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/860031-33-i.pdf?v=1598908093\" target=\"_blank\"\u003e \u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/Digital_ORP_Sensor_User_Manual.pdf\" title=\"Inline Digital ORP Sensor - Users Manual\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg alt=\"PDF\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/pdf-icon-63x63_480x480.png?v=1598991821\" style=\"float: left;\"\u003e\u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/860031-33-i.pdf?v=1598908093\" target=\"_blank\"\u003e\u003cbr\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/Digital_ORP_Sensor_User_Manual.pdf\" title=\"Inline Digital ORP Sensor - Users Manual\" rel=\"noopener\" target=\"_blank\"\u003eInstruction Manual\u003c\/a\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e","brand":"Sper Scientific","offers":[{"title":"Default Title","offer_id":46246435782880,"sku":"870001-ORP","price":547.63,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/inline-digital-orp-sensor-870001-orp-313724.jpg?v=1752691897"},{"product_id":"inline-digital-ph-sensorph-sensor","title":"Online Digital pH Sensor","description":"\u003ch1\u003eThe Digital Online pH Sensor is an advanced solution for accurate and reliable pH monitoring in challenging environments.\u003c\/h1\u003e\n\u003cp\u003eBuilt with durable SS316 stainless steel housing, it is designed for longevity and easy installation. This high-precision sensor offers fast response and stable, long-term performance, making it ideal for continuous monitoring. With a built-in temperature probe, it provides instant temperature compensation, and its strong anti-interference capability supports output cable lengths up to 500 meters.\u003c\/p\u003e\n\u003cp\u003eThe Digital Online pH Sensor is built with high-quality materials, offering reliable, long-term performance across various applications. Featuring a sleek, sturdy design, this sensor includes a sensor input connector and data storage capabilities to securely hold calibration and measurement data. Engineered for precision and durability, it is essential for continuous pH monitoring in industries such as environmental protection, pharmaceuticals, food and potable water treatment.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAccurate and Reliable\u003c\/strong\u003e\u003cbr\u003eThe Digital Online pH Sensor delivers precise, reliable measurements of pH levels, making it ideal for laboratory settings where accuracy is paramount.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAdvanced Technology\u003c\/strong\u003e\u003cbr\u003eEquipped with advanced technology and precision sensors, this pH sensor provides consistent, high-quality readings, safeguarding the integrity of experimental data.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eUser-Friendly Interface\u003c\/strong\u003e\u003cbr\u003eDesigned with a user-friendly interface, this sensor is an excellent choice for professionals and researchers who need a dependable tool for scientific work.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDurable Construction\u003c\/strong\u003e\u003cbr\u003eBuilt to withstand the demands of laboratory environments, the Sper Scientific Digital pH sensor offers robust construction and long-lasting performance.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eOrdering Notes: \u003cbr\u003e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003e1. All Sper Online \u003ca title=\"Inline Water Quality Monitoring\" href=\"https:\/\/sperdirect.com\/collections\/inline-water-quality-monitors-sensors\"\u003eWater Quality Meters and Sensors\u003c\/a\u003e are sold separately - one of each is required for a complete system. \u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003e\u003cspan\u003e\u003cspan style=\"color: #ff2a00;\"\u003e2. All Online Water Quality Meters and Sensors ship direct from the factory. Please allow 10-15 business days for shipping and \u003cspan style=\"caret-color: rgb(255, 42, 0);\"\u003ehandling\u003c\/span\u003e. \u003c\/span\u003e\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable style=\"width: 100%; height: 453.906px;\" class=\"table table-bordered table-hover\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\" class=\"firstRow\"\u003e\n\u003ctd style=\"width: 32.8012%; height: 19.5938px;\" class=\"selectTdClass\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.3526%; height: 19.5938px;\" class=\"selectTdClass\"\u003e\u003cstrong\u003e870001-pH Digital Online pH Sensor\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.8012%; height: 19.5938px;\" class=\"selectTdClass\"\u003e\u003cstrong\u003epH Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.3526%; height: 19.5938px;\" class=\"selectTdClass\"\u003e\n\u003cspan\u003e0~14\u003c\/span\u003e\u003cspan\u003epH \u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 106.781px;\"\u003e\n\u003ctd style=\"width: 32.8012%; height: 106.781px;\" class=\"selectTdClass\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 63.3526%; height: 106.781px;\" class=\"selectTdClass\"\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e0~65℃\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 71.1875px;\"\u003e\n\u003ctd style=\"width: 32.8012%; height: 71.1875px;\" class=\"selectTdClass\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eAccuracy\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 63.3526%; height: 71.1875px;\" class=\"selectTdClass\"\u003e\n\u003cp\u003e±0.1pH  \u003c\/p\u003e\n\u003cp\u003e±0.5℃\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 32.8012%;\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eResolution\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 63.3526%;\"\u003e\n\u003cp\u003e0.01 pH; 0.1 °C\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.5938px;\"\u003e\n\u003ctd style=\"width: 32.8012%; height: 35.5938px;\" class=\"selectTdClass\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003ePower\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 63.3526%; height: 35.5938px;\" class=\"selectTdClass\"\u003e\n\u003cp\u003e\u003cspan\u003e9~36V DC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.5938px;\"\u003e\n\u003ctd style=\"width: 32.8012%; height: 35.5938px;\" class=\"selectTdClass\"\u003e\u003cstrong\u003e\u003cspan\u003eCommunication\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.3526%; height: 35.5938px;\" class=\"selectTdClass\"\u003e\n\u003cp\u003e\u003cspan\u003eStandard RS485\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.8012%; height: 19.5938px;\" class=\"selectTdClass\"\u003e\n\u003cstrong\u003eHousing Material\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 63.3526%; height: 19.5938px;\" class=\"selectTdClass\"\u003eSS316 Stainless Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 55.1875px;\"\u003e\n\u003ctd style=\"width: 32.8012%; height: 55.1875px;\" class=\"selectTdClass\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eProcess Connection\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 63.3526%; height: 55.1875px;\" class=\"selectTdClass\"\u003e\n\u003cp\u003e\u003cspan\u003eUpper G1”\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.5938px;\"\u003e\n\u003ctd style=\"width: 32.8012%; height: 35.5938px;\" class=\"selectTdClass\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProtection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 63.3526%; height: 35.5938px;\" class=\"selectTdClass\"\u003eIP68\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 55.1875px;\"\u003e\n\u003ctd style=\"width: 32.8012%; height: 55.1875px;\" class=\"selectTdClass\"\u003e\u003cstrong\u003eCable Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.3526%; height: 55.1875px;\" class=\"selectTdClass\"\u003e\n\u003cp\u003eStandard 5 meters cable \u003cbr\u003e(extendable up to 500 meters)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003eDownloads\u003c\/h4\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cstrong\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/860031-33-i.pdf?v=1598908093\" target=\"_blank\"\u003e \u003c\/a\u003e\u003ca rel=\"noopener\" title=\"Inline Digital pH Sensor - Users Manual\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/Inline_Digital_pH_Sensor_User_Manual.pdf\" target=\"_blank\"\u003e\u003cimg style=\"float: left;\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/pdf-icon-63x63_480x480.png?v=1598991821\" alt=\"PDF\"\u003e\u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/860031-33-i.pdf?v=1598908093\" target=\"_blank\"\u003e\u003cbr\u003e\u003c\/a\u003e\u003ca rel=\"noopener\" title=\"Inline Digital pH Sensor - Users Manual\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/Inline_Digital_pH_Sensor_User_Manual.pdf\" target=\"_blank\"\u003eInstruction Manual\u003c\/a\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e","brand":"Sper Scientific","offers":[{"title":"Default Title","offer_id":46246435913952,"sku":"870001-PH","price":527.15,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/inline-digital-ph-sensor-870001-ph-822361.png?v=1752691910"},{"product_id":"multi-parameter-analyzer","title":"Online Multi-Parameter Water Quality Analyzer","description":"\u003cp\u003e\u003cb\u003eOrdering Notes:\u003cbr\u003e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003e1. All Sper Inline Water Quality Meters and Sensors are sold separately - please be sure to add the appropriate sensor (listed above) when purchasing your meter - one of each is required for a complete system. \u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003e\u003cspan\u003e\u003cspan style=\"color: #ff2a00;\"\u003e2. All Inline Water Quality Meters and Sensors ship direct from the factory. Please allow 10-15 business days for shipping and \u003cspan style=\"caret-color: rgb(255, 42, 0);\"\u003ehandling\u003c\/span\u003e. \u003c\/span\u003e\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eMulti-Parameter Inline Water Quality Analyzer\u003c\/h1\u003e\n\u003cp\u003eThe Multi-Parameter Water Quality Analyzer is an advanced online analysis system designed for comprehensive water quality monitoring. It integrates up to eight (8) different water quality parameters into a single unit, which is \u003cmeta charset=\"utf-8\"\u003edisplayed and managed on a touch screen panel. This system combines real-time water quality analysis, remote data transmission, database management, analysis software, and system calibration functions into one convenient platform, streamlining water quality data collection and analysis.\u003c\/p\u003e\n\u003cp\u003eThe meter offers flexible configuration options, allowing you to customize the setup based on your specific needs. It supports a range of parameters including pH, ORP, dissolved oxygen, conductivity, temperature, ammonia (NH4+), COD, turbidity, and more. The system is equipped with a state-of-the-art tandem flow analysis device that requires minimal water and provides real-time results. Water samples pass through various sensors, capturing all parameters in real time and enabling easy expansion for larger-scale continuous monitoring.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCustomizable Parameters:\u003c\/strong\u003e Tailor monitoring parameters to your specific needs with flexible combinations and custom setups - connect up to eight digital sensors for simultaneous monitoring.\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSmart Monitoring:\u003c\/strong\u003e Achieve intelligent online monitoring through configurable software and parameter analysis modules.\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEfficient Water Use:\u003c\/strong\u003e The integrated tandem flow device requires minimal water to perform diverse real-time analyses.\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLow Maintenance:\u003c\/strong\u003e Automatic sensor and pipeline maintenance reduces manual intervention, simplifies complex field issues, and enhances measurement accuracy.\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStable Flow Technology:\u003c\/strong\u003e Patented decompression and constant flow technology ensure stable data analysis by maintaining consistent flow rates despite pipeline pressure changes.\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemote Data Options:\u003c\/strong\u003e Optional remote data links and database integration allow you to strategize and manage data from afar.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable style=\"width: 100.093%;\" class=\"table table-bordered table-hover\" data-sort=\"sortDisabled\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd style=\"width: 61.2274%;\" colspan=\"2\" width=\"403\"\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 38.1296%;\" width=\"68\"\u003e\u003cspan\u003e\u003cstrong\u003eSper #870001 Multi-Parameter Inline Water Quality Meter\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 61.2274%;\" colspan=\"2\" width=\"489\"\u003e\u003cspan\u003e\u003cstrong\u003eMeasurement Configuration\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 38.1296%;\" width=\"68\"\u003e\n\u003cp\u003e\u003cspan\u003epH,Conductivity, dissolved oxygen, COD, Turbidity, Suspended Solids, Ammonia, etc. (Note: the specific parameters to the actual ordering parameters prevail)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.0967%;\" rowspan=\"11\" colspan=\"1\" width=\"181\"\u003e\u003cspan\u003e\u003cstrong\u003eMeasuring Ranges\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 27.1307%;\" width=\"211\"\u003e\u003cspan\u003epH\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 38.1296%;\" width=\"68\"\u003e\u003cspan\u003e0-14.00pH\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.1307%;\" width=\"148\"\u003e\u003cspan\u003eDO\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 38.1296%;\" width=\"737\"\u003e\u003cspan\u003e0-20.00mg\/L\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.1307%;\" width=\"154\"\u003e\u003cspan\u003eORP\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 38.1296%;\" width=\"737\"\u003e\n\u003cp\u003e\u003cspan\u003e-1999—1999mV\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.1307%;\" width=\"159\"\u003e\u003cspan\u003eConductivity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 38.1296%;\" width=\"737\"\u003e\u003cspan\u003e0~2000us\/cm (max to 2000ms\/cm)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.1307%;\" width=\"163\"\u003e\u003cspan\u003eTurbidity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 38.1296%;\" width=\"737\"\u003e\u003cspan\u003e0-4000NTU\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.1307%;\" colspan=\"1\" rowspan=\"1\" width=\"32\"\u003e\u003cspan\u003eSuspended Solids (TSS)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 38.1296%;\" colspan=\"1\" rowspan=\"1\" width=\"732\"\u003e\u003cspan\u003e0~120 000mg\/L\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.1307%;\" colspan=\"1\" rowspan=\"1\" width=\"32\"\u003eAmmonia\u003c\/td\u003e\n\u003ctd style=\"width: 38.1296%;\" colspan=\"1\" rowspan=\"1\" width=\"732\"\u003eNH4+:0~5000mg\/L, NH3-N:0~1000mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.1307%;\" colspan=\"1\" rowspan=\"1\" width=\"32\"\u003eCOD\u003c\/td\u003e\n\u003ctd style=\"width: 38.1296%;\" colspan=\"1\" rowspan=\"1\" width=\"732\"\u003e0~1000mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.1307%;\" colspan=\"1\" rowspan=\"1\" width=\"32\"\u003eTemperature\u003c\/td\u003e\n\u003ctd style=\"width: 38.1296%;\" colspan=\"1\" rowspan=\"1\" width=\"732\"\u003e0 ~ 50C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.1307%;\" colspan=\"1\" rowspan=\"1\" width=\"32\"\u003eNitrate Nitrogen\u003c\/td\u003e\n\u003ctd style=\"width: 38.1296%;\" colspan=\"1\" rowspan=\"1\" width=\"732\"\u003e0~100mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 65.2603%;\" colspan=\"2\" rowspan=\"1\"\u003e(Note: Meter can be extended with other parameters, please confirm before ordering)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.0967%;\" width=\"182\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCommunication Protocol\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 65.2603%;\" colspan=\"2\" width=\"994\"\u003e\u003cspan\u003eRS485 Modbus RTU\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.0967%;\" width=\"186\"\u003e\u003cspan\u003e\u003cstrong\u003eWireless\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.2603%;\" colspan=\"2\" width=\"994\"\u003e\u003cspan\u003eLocal SIM card and \u003cmeta charset=\"utf-8\"\u003emobile app  (optional)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.0967%;\" colspan=\"1\" rowspan=\"1\"\u003e\u003cstrong\u003eData Logger\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.2603%;\" colspan=\"2\" rowspan=\"1\"\u003eYes\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.0967%;\" colspan=\"1\" rowspan=\"1\"\u003e\u003cstrong\u003eUSB\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.2603%;\" colspan=\"2\" rowspan=\"1\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.0967%;\" width=\"187\"\u003e\u003cspan\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.2603%;\" colspan=\"2\" width=\"994\"\u003e\n\u003cp\u003e\u003cspan\u003e24V DC or 220V AC \u003cmeta charset=\"utf-8\"\u003e±10%\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.0967%;\" width=\"187\"\u003e\u003cspan\u003e\u003cstrong\u003eWorking Condition\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.2603%;\" colspan=\"2\" width=\"994\"\u003e\n\u003cp\u003e\u003cspan\u003eTemperature: 0-122ºF (0-50℃)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.0967%;\" width=\"187\"\u003e\u003cspan\u003e\u003cstrong\u003eStorage Condition\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.2603%;\" colspan=\"2\" width=\"994\"\u003e\n\u003cp\u003e\u003cspan\u003eRelative Humidity: ≤85% RH（without condensation）\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.0967%;\" width=\"187\"\u003e\u003cspan\u003e\u003cstrong\u003eNotes\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.2603%;\" colspan=\"2\" width=\"994\"\u003e\n\u003cp\u003e\u003cspan\u003eOther parameters can be customized based on requirements.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4\u003eDownloads\u003c\/h4\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cstrong\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/860031-33-i.pdf?v=1598908093\" target=\"_blank\"\u003e \u003c\/a\u003e\u003ca rel=\"noopener\" title=\"Multi-Parameter Inline Water Quality Analyzer- Users Manual\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/870001_Multi-Parameter_Water_Quality_Analyzer_Manual.pdf\" target=\"_blank\"\u003e\u003cimg alt=\"PDF\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/pdf-icon-63x63_480x480.png?v=1598991821\" style=\"float: left;\"\u003e\u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/860031-33-i.pdf?v=1598908093\" target=\"_blank\"\u003e\u003cbr\u003e\u003c\/a\u003e\u003ca title=\"Multi-Parameter Inline Water Quality Analyzer- Users Manual\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/870001_Multi-Parameter_Water_Quality_Analyzer_Manual.pdf\"\u003eInstruction Manual\u003c\/a\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"Sper Scientific","offers":[{"title":"Default Title","offer_id":46246435946720,"sku":"870001","price":1819.7,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/multi-parameter-inline-water-quality-analyzer-870001-820665.jpg?v=1752691911"},{"product_id":"870002-online-ph-electrode","title":"Online Industrial Wastewater PH Sensor","description":"\u003ch1\u003eThe electrode features a world-class solid dielectric and a large PTFE liquid junction, ensuring a non-blocking design that is easy to maintain.\u003c\/h1\u003e\n\u003cp\u003eIts long-distance reference diffusion channel enhances durability, allowing it to withstand harsh environments for extended service life. The PPS\/PC casing, combined with a 3\/4NPT threaded pipe on both ends, simplifies installation without the need for a separate jacket, reducing overall installation costs. Equipped with a high-quality, low-noise cable, it maintains signal integrity for distances of over 20 meters without interference.\u003c\/p\u003e\n\u003cp\u003eWith no need for additional dielectric, this electrode requires minimal maintenance while offering high accuracy, quick response times, and excellent repeatability. It features a silver ion Ag\/AgCl reference electrode and proper use can further extend its service life. The electrode can be installed laterally or vertically in reaction tanks or pipelines.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSolid dielectric and large PTFE liquid junction for low maintenance\u003c\/li\u003e\n\u003cli\u003eLong-distance reference diffusion channel for extended lifespan\u003c\/li\u003e\n\u003cli\u003eDurable PPS\/PC casing with 3\/4NPT threads for easy installation, no jacket required\u003c\/li\u003e\n\u003cli\u003eHigh-quality low-noise cable allows interference-free signal over 20 meters\u003c\/li\u003e\n\u003cli\u003eMinimal maintenance with no need for additional dielectric\u003c\/li\u003e\n\u003cli\u003eHigh accuracy, fast response, and good repeatability\u003c\/li\u003e\n\u003cli\u003eSilver ion Ag\/AgCl reference electrode\u003c\/li\u003e\n\u003cli\u003eVersatile installation: lateral or vertical in tanks or pipelines\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003eOrdering Notes: \u003cbr\u003e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003e1. All Sper Inline \u003ca href=\"https:\/\/sperdirect.com\/collections\/inline-water-quality-monitors-sensors\" title=\"Inline Water Quality Monitoring\"\u003eWater Quality Meters and Sensors\u003c\/a\u003e are sold separately - one of each is required for a complete system. \u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003e\u003cspan\u003e\u003cspan style=\"color: #ff2a00;\"\u003e2. All Inline Water Quality Meters and Sensors ship direct from the factory. Please allow 10-15 business days for shipping and \u003cspan style=\"caret-color: rgb(255, 42, 0);\"\u003ehandling\u003c\/span\u003e. \u003c\/span\u003e\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable height=\"274\" border=\"1\" cellspacing=\"0\" style=\"width: 79.2007%;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\" width=\"161\" style=\"width: 29.1439%;\"\u003e\u003cspan\u003eMeasuring Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"406\" style=\"width: 70.8561%;\"\u003e\u003cspan\u003e0-14pH\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\" width=\"161\" style=\"width: 29.1439%;\"\u003e\u003cspan\u003eTemperature \u003cmeta charset=\"utf-8\"\u003eRange\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"406\" style=\"width: 70.8561%;\"\u003e\u003cspan\u003e32-140\u003cmeta charset=\"utf-8\"\u003eºF (0-60℃)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 29.1439%;\"\u003e\u003cspan\u003eAccuracy \u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.8561%;\"\u003e\u003cspan\u003e±0.1 pH \/ ±0.5 °C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 29.1439%;\"\u003e\u003cspan\u003e\u003cmeta charset=\"utf-8\"\u003eTemperature Compensation\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.8561%;\"\u003e\u003cspan\u003e 10K, 2.252K, PT100, PT1000\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\" width=\"161\" style=\"width: 29.1439%;\"\u003e\u003cspan\u003eCompressive Strength\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"406\" style=\"width: 70.8561%;\"\u003e\u003cspan\u003e0.6 MPa\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\" width=\"161\" style=\"width: 29.1439%;\"\u003e\u003cspan\u003eSlope\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"406\" style=\"width: 70.8561%;\"\u003e\u003cspan\u003e≥96％\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\" width=\"161\" style=\"width: 29.1439%;\"\u003e\u003cspan\u003eZero point potential\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"406\" style=\"width: 70.8561%;\"\u003e\u003cspan\u003eE0=7 PH±0.3\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\" width=\"161\" style=\"width: 29.1439%;\"\u003e\u003cspan\u003eInternal impedance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"406\" style=\"width: 70.8561%;\"\u003e\u003cspan\u003e150-250 MΩ (25℃)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\" width=\"161\" style=\"width: 29.1439%;\"\u003e\u003cspan\u003eMaterial\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"406\" style=\"width: 70.8561%;\"\u003e\u003cspan\u003eNatural Tetrafluoro\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\" width=\"161\" style=\"width: 29.1439%;\"\u003e\u003cspan\u003eProfile\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"406\" style=\"width: 70.8561%;\"\u003e\u003cspan\u003e3-in-1 Electrode (Integrating the temperature compensation and the solution grounding)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\" width=\"161\" style=\"width: 29.1439%;\"\u003e\u003cspan\u003eInstallation size\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"406\" style=\"width: 70.8561%;\"\u003e\u003cspan\u003eUpper and Lower 3\/4NPT Pipe Thread\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\" width=\"161\" style=\"width: 29.1439%;\"\u003e\u003cspan\u003eConnection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"406\" style=\"width: 70.8561%;\"\u003e\u003cspan\u003eLow-noise cable goes out directly\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\" width=\"161\" style=\"width: 29.1439%;\"\u003e\u003cspan\u003eApplications\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"406\" style=\"width: 70.8561%;\"\u003e\u003cspan\u003eApplicable to various industrial sewage, environmental protection and water treatment\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4\u003eDownloads\u003c\/h4\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cstrong\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/860031-33-i.pdf?v=1598908093\" target=\"_blank\"\u003e \u003c\/a\u003e\u003ca rel=\"noopener\" title=\"Inline Industrial pH Sensor - Users Manual\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/870002-PH_Inline_Industrial_PH_Electrode_User_Manual.pdf\" target=\"_blank\"\u003e\u003cimg alt=\"PDF\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/pdf-icon-63x63_480x480.png?v=1598991821\" style=\"float: left;\"\u003e\u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/860031-33-i.pdf?v=1598908093\" target=\"_blank\"\u003e\u003cbr\u003e\u003c\/a\u003e\u003ca rel=\"noopener\" title=\"Inline Industrial pH Sensor - Users Manual\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/870002-PH_Inline_Industrial_PH_Electrode_User_Manual.pdf\" target=\"_blank\"\u003eInstruction Manual\u003c\/a\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"Sper Scientific","offers":[{"title":"Default Title","offer_id":46246436143328,"sku":"870002-PH","price":179.08,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/inline-industrial-wastewater-ph-sensor-870002-ph-611335.jpg?v=1752691881"},{"product_id":"industrial-ph-orp-meter","title":"Online Industrial PH \u0026 ORP Meter","description":"\u003cp\u003e\u003cb\u003eOrdering Notes:\u003cbr\u003e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003e1. ALL SPER ONLINE WATER QUALITY METERS AND SENSORS ARE SOLD SEPARATELY - Please be sure to add the appropriate sensor (listed above) when purchasing your meter - ONE METER AND SENSOR are required for a complete system. \u003c\/span\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003e\u003cspan\u003e\u003cspan style=\"color: #ff2a00;\"\u003e2. All Inline Water Quality Meters and Sensors ship direct from the factory. Please allow 10-15 business days for shipping and \u003cspan style=\"caret-color: rgb(255, 42, 0);\"\u003ehandling\u003c\/span\u003e. \u003c\/span\u003e\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eOur Inline Industrial PH \u0026amp; ORP Meter offers stable and reliable operation designed to solve common issues faced by operators in water treatment and processing plants. \u003c\/h1\u003e\n\u003cp\u003eThese analyzers provide precise, continuous measurement, ensuring dependable water quality monitoring. Each pH and ORP meter is equipped with a transmitter and process adaptation, tailored to meet your specific pH control requirements. The meter delivers accurate readings in diverse environments, from ultra-pure water to bioreactor applications - even in challenging conditions like chemical production.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eStable, precise, continuous measurement of pH, ORP and temperature\u003c\/li\u003e\n\u003cli\u003eFlexible installation options: panel, wall, or pipe-mounted\u003c\/li\u003e\n\u003cli\u003eDual 4-20mA outputs and standard RS485 Modbus RTU communication\u003c\/li\u003e\n\u003cli\u003eHigh\/low control relay functionality\u003c\/li\u003e\n\u003cli\u003eLocal data logging for up to 1,000 entries\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications include industrial wastewater, drinking water monitoring, environmental monitoring, ultra-pure water, fermentation, food production and more.\u003cb\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable data-sort=\"sortDisabled\" class=\"table table-bordered table-hover\" style=\"width: 100%; height: 550px;\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"firstRow\" style=\"height: 35px;\"\u003e\n\u003ctd width=\"141\" style=\"width: 25.589837%; height: 35px;\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"166\" colspan=\"2\" rowspan=\"1\" style=\"width: 72.232305%; height: 35px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eSper Scientific #870002 \u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35px;\"\u003e\n\u003ctd width=\"141\" style=\"width: 25.589837%; height: 35px;\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eMeasurement\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"176\" colspan=\"2\" rowspan=\"1\" style=\"width: 72.232305%; height: 35px;\"\u003e\u003cspan\u003epH \/ ORP \/ Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 54px;\"\u003e\n\u003ctd width=\"141\" style=\"width: 25.589837%; height: 54px;\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"176\" colspan=\"2\" rowspan=\"1\" style=\"width: 72.232305%; height: 54px;\"\u003e\n\u003cp\u003e\u003cspan\u003e-2 ~16 pH, -2000 ~2000 mV, -30 ~130 ℃\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd width=\"141\" colspan=\"1\" rowspan=\"1\" style=\"width: 25.589837%; height: 19px;\"\u003e\u003cspan\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd width=\"176\" colspan=\"2\" rowspan=\"1\" style=\"width: 72.232305%; height: 19px;\"\u003e\u003cspan\u003e0.05pH,  ±0.2℃\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35px;\"\u003e\n\u003ctd width=\"141\" style=\"width: 25.589837%; height: 35px;\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eHousing Material\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"176\" colspan=\"2\" style=\"width: 72.232305%; height: 35px;\"\u003e\n\u003cp\u003e\u003cspan\u003eABS Flame retardant : V0\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35px;\"\u003e\n\u003ctd width=\"141\" style=\"width: 25.589837%; height: 35px;\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003ePower\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"176\" colspan=\"2\" style=\"width: 72.232305%; height: 35px;\"\u003e\n\u003cp\u003e\u003cspan\u003e90 – 260V AC 50\/60Hz\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35px;\"\u003e\n\u003ctd width=\"141\" style=\"width: 25.589837%; height: 35px;\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eConsumption\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"176\" colspan=\"2\" style=\"width: 72.232305%; height: 35px;\"\u003e\n\u003cp\u003e\u003cspan\u003e4W\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35px;\"\u003e\n\u003ctd width=\"141\" style=\"width: 25.589837%; height: 35px;\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOutput\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"176\" colspan=\"2\" style=\"width: 72.232305%; height: 35px;\"\u003e\n\u003cp\u003e\u003cspan\u003eTwo ways 4-20mA output\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd width=\"141\" rowspan=\"1\" colspan=\"1\" style=\"width: 25.589837%; height: 19px;\"\u003e\u003cspan\u003e\u003cstrong\u003eCommunication\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd width=\"176\" rowspan=\"1\" colspan=\"2\" style=\"width: 72.232305%; height: 19px;\"\u003e\u003cspan\u003eRS485 Modbus\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35px;\"\u003e\n\u003ctd width=\"141\" style=\"width: 25.589837%; height: 35px;\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eRelay\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"176\" colspan=\"2\" style=\"width: 72.232305%; height: 35px;\"\u003e\n\u003cp\u003e\u003cspan\u003eThree relays, 5A\/250V AC      5A\/30V DC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35px;\"\u003e\n\u003ctd width=\"141\" style=\"width: 25.589837%; height: 35px;\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eTemperature Comp\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"176\" colspan=\"2\" style=\"width: 72.232305%; height: 35px;\"\u003e\n\u003cp\u003e\u003cspan\u003ePT1000 \/ NTC10K\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd rowspan=\"1\" colspan=\"1\" style=\"width: 25.589837%; height: 19px;\"\u003e\u003cstrong\u003eDimension\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd rowspan=\"1\" colspan=\"2\" style=\"width: 72.232305%; height: 19px;\"\u003e\u003cspan\u003e144×144×104mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd rowspan=\"1\" colspan=\"1\" style=\"width: 25.589837%; height: 19px;\"\u003e\u003cstrong\u003eHole Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd rowspan=\"1\" colspan=\"2\" style=\"width: 72.232305%; height: 19px;\"\u003e138*138mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35px;\"\u003e\n\u003ctd width=\"141\" style=\"width: 25.589837%; height: 35px;\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProtection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"176\" colspan=\"2\" style=\"width: 72.232305%; height: 35px;\"\u003e\u003cspan\u003eIP65\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35px;\"\u003e\n\u003ctd width=\"141\" style=\"width: 25.589837%; height: 35px;\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eData logger\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"166\" rowspan=\"1\" colspan=\"2\" style=\"width: 72.232305%; height: 35px;\"\u003e\u003cspan\u003e1,000 times\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35px;\"\u003e\n\u003ctd width=\"141\" style=\"width: 25.589837%; height: 35px;\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eLanguage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"176\" colspan=\"2\" style=\"width: 72.232305%; height: 35px;\"\u003e\n\u003cp\u003e\u003cspan\u003eEnglish \/ 简体中文\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35px;\"\u003e\n\u003ctd width=\"141\" style=\"width: 25.589837%; height: 35px;\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eInstallation\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"176\" colspan=\"2\" style=\"width: 72.232305%; height: 35px;\"\u003e\n\u003cp\u003e\u003cspan\u003ePanel \/ Wall \/ Pipe mounted\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4\u003eDownloads\u003c\/h4\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cstrong\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/860031-33-i.pdf?v=1598908093\" target=\"_blank\"\u003e \u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/870002Industrial_pH_and_ORP_Manual.pdf\" title=\"Inline pH ORP Mater - Users Manual\"\u003e\u003cimg alt=\"PDF\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/pdf-icon-63x63_480x480.png?v=1598991821\" style=\"float: left;\"\u003e\u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/860031-33-i.pdf?v=1598908093\" target=\"_blank\"\u003e\u003cbr\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/870002Industrial_pH_and_ORP_Manual.pdf\" title=\"Inline pH ORP Mater - Users Manual\"\u003eInstruction Manual\u003c\/a\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Sper Scientific","offers":[{"title":"Default Title","offer_id":46246436176096,"sku":"870002","price":661.55,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/inline-industrial-ph-orp-meter-870002-793550.jpg?v=1752691886"},{"product_id":"digital-turbidity-meter","title":"Online Digital Turbidity Meter","description":"\u003cp\u003e\u003cb\u003eOrdering Notes:\u003cbr\u003e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003e1. ALL SPER ONLINE WATER QUALITY METERS AND SENSORS ARE SOLD SEPARATELY - Please be sure to add the appropriate sensor (listed above) when purchasing your meter - ONE METER AND SENSOR are required for a complete system. \u003c\/span\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003e\u003cspan\u003e\u003cspan style=\"color: #ff2a00;\"\u003e2. All Online Water Quality Meters and Sensors ship direct from the factory. Please allow 10-15 business days for shipping and \u003cspan style=\"caret-color: rgb(255, 42, 0);\"\u003ehandling\u003c\/span\u003e.\u003c\/span\u003e\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eThe Sper Scientific Online Digital Turbidity Meter is a state-of-the-art instrument engineered for precise and reliable continuous turbidity measurement, conforming to international standards.\u003c\/h1\u003e\n\u003cp\u003eThe \u003cstrong\u003eSper Scientific Digital Turbidity Meter\u003c\/strong\u003e is an advanced instrument engineered for precise and reliable continuous turbidity measurement, adhering to international standards in a wide variety of applications. With a measuring range of \u003cstrong\u003e0-100.00 NTU\u003c\/strong\u003e, \u003cstrong\u003e0-3000.00 NTU\u003c\/strong\u003e, \u003cstrong\u003e0-4000.00 NTU\u003c\/strong\u003e and \u003cstrong\u003e0-10000.00 NTU\u003c\/strong\u003e, this meter is versatile and suitable for a variety of applications. Its advanced RS485 Modbus RTU digital turbidity sensor ensures accuracy and durability, making it an essential tool for effective water quality management.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrecision Measurement:\u003c\/strong\u003e Achieve high accuracy with a tolerance of ±2%, ensuring reliable turbidity readings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBroad Measuring Range:\u003c\/strong\u003e Handles turbidity levels from 0.01 NTU to 10,000 NTU, accommodating various water conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLong Service Life:\u003c\/strong\u003e Designed for extended operation, minimizing the need for frequent replacements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRapid Calibration:\u003c\/strong\u003e Quick and easy calibration processes allow users to verify measurements in seconds.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDigital Connectivity:\u003c\/strong\u003e RS485 Modbus RTU interface enables seamless integration with existing monitoring systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDatalogger:\u003c\/strong\u003e Built-in datalogger for recording measurements, facilitating long-term monitoring and analysis.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection Rating:\u003c\/strong\u003e IP65 rating ensures protection against dust and water ingress, suitable for various environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDrinking and Process Water Monitoring:\u003c\/strong\u003e Ensures compliance with safety standards and optimal water quality.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcess and Filter Monitoring:\u003c\/strong\u003e Facilitates efficient operation in industrial settings, monitoring filter performance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFilter Backwash Assessment:\u003c\/strong\u003e Provides critical data for filter maintenance in waterworks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWater Quality Monitoring in Distribution Networks:\u003c\/strong\u003e Supports utilities in maintaining high water quality throughout distribution systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUtility Operations Across Industries:\u003c\/strong\u003e Versatile enough for various sectors, from manufacturing to municipal services.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRecirculation Lines:\u003c\/strong\u003e Monitors turbidity levels in recirculating systems to ensure water clarity and safety.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCooling Water Turbidity Monitoring:\u003c\/strong\u003e Essential for maintaining optimal conditions in cooling systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"easytabs-undertabs-holder\"\u003e\n\u003cb\u003e\u003c\/b\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable style=\"width: 100.091%;\" class=\"table table-bordered table-hover\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd style=\"width: 27.7064%;\" colspan=\"1\" rowspan=\"1\" width=\"137\"\u003e\u003cstrong\u003eProduct\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 71.9266%;\" colspan=\"1\" rowspan=\"1\" width=\"357\"\u003e\u003cstrong\u003eOnline Digital Turbidity Meter\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.7064%;\" width=\"137\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eMeasuring range\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 71.9266%;\" width=\"357\"\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e0-100.00,0~3000.00 , 0-4000.00,10000.00 NTU\u003cbr\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.7064%;\" colspan=\"1\" rowspan=\"1\" width=\"137\"\u003e\u003cstrong\u003eUnit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 71.9266%;\" colspan=\"1\" rowspan=\"1\" width=\"357\"\u003eNTU \/ FTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.7064%;\" width=\"137\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eAccuracy\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 71.9266%;\" width=\"357\"\u003e\n\u003cp\u003e\u003cspan\u003e± 2%\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.7064%;\" width=\"137\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003ePower\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 71.9266%;\" width=\"357\"\u003e\n\u003cp\u003e\u003cspan\u003e90 – 260V AC 50\/60Hz\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.7064%;\" width=\"137\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eCurrent output\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 71.9266%;\" width=\"357\"\u003e\n\u003cp\u003e\u003cspan\u003e4-20mA\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.7064%;\" width=\"137\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eCommunication \u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 71.9266%;\" width=\"357\"\u003e\n\u003cp\u003e\u003cspan\u003eRS485 Modbus RTU\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.7064%;\" width=\"137\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eProtection \u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 71.9266%;\" width=\"357\"\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.7064%;\" width=\"137\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eRelay\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 71.9266%;\" width=\"357\"\u003e3 relays ,5A\/250V AC      5A\/30V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.7064%;\" width=\"137\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eOverall dimension\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 71.9266%;\" width=\"357\"\u003e144×144×104mm L*W*H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.7064%;\" width=\"137\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eHole size\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 71.9266%;\" width=\"357\"\u003e\n\u003cp\u003e\u003cspan\u003e138x138 mm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.7064%;\" width=\"137\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eDatalogger\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 71.9266%;\" width=\"357\"\u003e\n\u003cp\u003e\u003cspan\u003eYES\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.7064%;\" width=\"137\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eCable length\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 71.9266%;\" width=\"357\"\u003e\n\u003cp\u003e\u003cspan\u003e3 meters\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4\u003eDownloads\u003c\/h4\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cstrong\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/860031-33-i.pdf?v=1598908093\" target=\"_blank\"\u003e \u003c\/a\u003e\u003ca rel=\"noopener\" title=\"Inline Digital Turbidity Meter - Users Manual\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/870004_Turbidity_Meter_User_Manual.pdf\" target=\"_blank\"\u003e\u003cimg alt=\"PDF\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/pdf-icon-63x63_480x480.png?v=1598991821\" style=\"float: left;\"\u003e \u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/860031-33-i.pdf?v=1598908093\" target=\"_blank\"\u003e\u003cbr\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/870004_Turbidity_Meter_User_Manual.pdf\" title=\"Inline Digital Turbidity Meter - Users Manual\" rel=\"noopener\" target=\"_blank\"\u003eInstruction Manual\u003c\/a\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Sper Scientific","offers":[{"title":"Default Title","offer_id":46246436438240,"sku":"870004","price":939.28,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/inline-digital-turbidity-meter-870004-461669.jpg?v=1752691910"},{"product_id":"turbidity-sensor","title":"Online Turbidity Sensor","description":"\u003ch1\u003eThe Online Digital Turbidity Sensor uses an advanced light scattering method, combining infrared absorption and infrared scattering.\u003c\/h1\u003e\n\u003cp\u003eInfrared light emitted from the source interacts with suspended particles in the sample, and the resulting scattered light is detected by a photodetector. This is then converted to an electrical signal, processed to yield an accurate turbidity reading through analog and digital signal processing.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e\u003cmeta charset=\"utf-8\"\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDrinking Water Treatment\u003c\/strong\u003e\u003cbr\u003eEnsure water meets regulatory standards.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWastewater Treatment\u003c\/strong\u003e\u003cbr\u003eMonitor effluent quality.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Monitoring\u003c\/strong\u003e\u003cbr\u003eAssess the clarity of lakes, rivers, and streams.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial Processes\u003c\/strong\u003e\u003cbr\u003eMaintain clarity in production lines, especially in food and beverage industries.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccurate and Reliable\u003c\/strong\u003e\u003cbr\u003eProvides consistent, precise measurements, ideal for laboratory and field use.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdvanced Technology\u003c\/strong\u003e\u003cbr\u003eUtilizes high-precision sensors for reliable data, ensuring experimental integrity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUser-Friendly Interface\u003c\/strong\u003e\u003cbr\u003eSimple, intuitive controls make it easy to operate for professionals and researchers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDurable Construction\u003c\/strong\u003e\u003cbr\u003eDesigned to withstand demanding laboratory conditions, offering reliable, long-lasting performance.\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003cstrong\u003eIncluded self-cleaning wiper\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003eOrdering Notes: \u003cbr\u003e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003e1. All Sper Inline \u003ca href=\"https:\/\/sperdirect.com\/collections\/inline-water-quality-monitors-sensors\" title=\"Inline Water Quality Monitoring\"\u003eWater Quality Meters and Sensors\u003c\/a\u003e are sold separately - one of each is required for a complete system. \u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003e\u003cspan\u003e\u003cspan style=\"color: #ff2a00;\"\u003e2. All Inline Water Quality Meters and Sensors ship direct from the factory. Please allow 10-15 business days for shipping and \u003cspan style=\"caret-color: rgb(255, 42, 0);\"\u003ehandling\u003c\/span\u003e.\u003c\/span\u003e\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable style=\"width: 100%; height: 411.469px;\" border=\"1\" cellspacing=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 25.9494%; height: 39.1875px;\" valign=\"center\" width=\"124\"\u003e\u003cstrong\u003e\u003cspan\u003eMeasuring Range\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.0506%; height: 39.1875px;\" valign=\"center\" width=\"368\"\u003e\u003cspan\u003e0.01-100 NTU，0.01－4000 NTU\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.9494%;\"\u003e\u003cstrong\u003e\u003cspan\u003eResolution\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.0506%;\"\u003e\u003cspan\u003e0.01 NTU\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 25.9494%; height: 39.1875px;\" valign=\"center\" width=\"124\"\u003e\u003cstrong\u003e\u003cspan\u003eAccuracy\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.0506%; height: 39.1875px;\" valign=\"center\" width=\"368\"\u003e\u003cspan\u003eLess than the measured value of ±1%, \u003cbr\u003eor ±0.1NTU，whichever is larger\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 25.9494%; height: 19.5938px;\" valign=\"center\" width=\"124\"\u003e\u003cstrong\u003e\u003cspan\u003ePressure Range\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.0506%; height: 19.5938px;\" valign=\"center\" width=\"368\"\u003e\u003cspan\u003e≤0.4Mpa\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 25.9494%; height: 19.5938px;\" valign=\"center\" width=\"124\"\u003e\u003cstrong\u003e\u003cspan\u003eCurrent Speed\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.0506%; height: 19.5938px;\" valign=\"center\" width=\"368\"\u003e\u003cspan\u003e≤2.5m\/s, 8.2ft\/s\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 25.9494%; height: 19.5938px;\" valign=\"center\" width=\"124\"\u003e\u003cstrong\u003e\u003cspan\u003eCalibration\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.0506%; height: 19.5938px;\" valign=\"center\" width=\"368\"\u003e\u003cspan\u003eSample calibration, slope calibration\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 58.7812px;\"\u003e\n\u003ctd style=\"width: 25.9494%; height: 58.7812px;\" valign=\"center\" width=\"124\"\u003e\u003cstrong\u003e\u003cspan\u003eSensor Main Material\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"368\" style=\"text-align: left; width: 74.0506%; height: 58.7812px;\"\u003e\u003cspan\u003eBody: SUS316L + PVC（normal type), SUS316L Titanium + PVC（sea water type)；O type circle：Fluorine rubber； cable：PVC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 25.9494%; height: 19.5938px;\" valign=\"center\" width=\"124\"\u003e\u003cstrong\u003e\u003cspan\u003ePower Supply\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.0506%; height: 19.5938px;\" valign=\"center\" width=\"368\"\u003e\u003cspan\u003e12V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 25.9494%; height: 39.1875px;\" valign=\"center\" width=\"124\"\u003e\u003cstrong\u003e\u003cspan\u003eCommunication Interface\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.0506%; height: 39.1875px;\" valign=\"center\" width=\"368\"\u003e\u003cspan\u003eMODBUS  RS485\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 25.9494%; height: 39.1875px;\" valign=\"center\" width=\"124\"\u003e\u003cstrong\u003e\u003cspan\u003eTemperature Storage\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.0506%; height: 39.1875px;\" valign=\"center\" width=\"368\"\u003e\u003cspan\u003e5 to 149\u003cmeta charset=\"utf-8\"\u003eº F (-15 to 65℃)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 25.9494%; height: 39.1875px;\" valign=\"center\" width=\"124\"\u003e\u003cstrong\u003e\u003cspan\u003eWorking Temperature\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.0506%; height: 39.1875px;\" valign=\"center\" width=\"368\"\u003e\u003cspan\u003e32 to 113\u003cmeta charset=\"utf-8\"\u003eºF (0 to 45℃)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 25.9494%; height: 19.5938px;\" valign=\"center\" width=\"124\"\u003e\u003cstrong\u003e\u003cspan\u003eSize\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.0506%; height: 19.5938px;\" valign=\"center\" width=\"368\"\u003e\u003cspan\u003e2.3 x 10 inches (60mm x 256mm)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 25.9494%; height: 19.5938px;\" valign=\"center\" width=\"124\"\u003e\u003cstrong\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.0506%; height: 19.5938px;\" valign=\"center\" width=\"368\"\u003e\u003cspan\u003e3.6lbs. (1.65kg)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 25.9494%; height: 19.5938px;\" valign=\"center\" width=\"124\"\u003e\u003cstrong\u003e\u003cspan\u003eProtection Grade\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.0506%; height: 19.5938px;\" valign=\"center\" width=\"368\"\u003e\u003cspan\u003eIP68\/NEMA6P\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 25.9494%; height: 19.5938px;\" valign=\"center\" width=\"124\"\u003e\u003cstrong\u003e\u003cspan\u003eCable Length\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.0506%; height: 19.5938px;\" valign=\"center\" width=\"368\"\u003e\u003cspan\u003eStandard 10m cable, can be extended to 100m\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4\u003eDownloads\u003c\/h4\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cstrong\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/860031-33-i.pdf?v=1598908093\" target=\"_blank\"\u003e \u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/Turbidity_Sensor_User_Manual.pdf\" title=\"Inline Digital Turbisity Sensor - Users Manual\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg alt=\"PDF\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/pdf-icon-63x63_480x480.png?v=1598991821\" style=\"float: left;\"\u003e\u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/860031-33-i.pdf?v=1598908093\" target=\"_blank\"\u003e\u003cbr\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/Turbidity_Sensor_User_Manual.pdf\" title=\"Inline Digital Turbisity Sensor - Users Manual\" rel=\"noopener\" target=\"_blank\"\u003eInstruction Manual\u003c\/a\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e","brand":"Sper Scientific","offers":[{"title":"Default Title","offer_id":46246436536544,"sku":"870004-TB","price":2126.3,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/inline-turbidity-sensor-870004-tb-338006.jpg?v=1752691889"},{"product_id":"wireless-module","title":"Wireless Module","description":"\u003cp class=\"p1\"\u003eGPRS gateway used by EMCP IOT cloud platform for MODBUS data automatic acquisition and transmission.\u003c\/p\u003e\n\u003ch4 class=\"p1\"\u003eDownloads\u003cspan style=\"font-size: 0.875rem;\"\u003e\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/WM-6099_DTU_Wireless_Module.pdf\" target=\"_blank\" title=\"WM-6099 Datasheet\" rel=\"noopener\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/pdf-icon-63x63_480x480.png?v=1598991821\" style=\"float: left;\" alt=\"PDF\"\u003e\u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/cr8-e.pdf?v=1704924058\" target=\"_blank\"\u003e\u003cbr\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/WM-6099_DTU_Wireless_Module.pdf\" target=\"_blank\" title=\"WM-6099 Product Datasheet\" rel=\"noopener\"\u003eProduct Datasheet\u003c\/a\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Sper Scientific","offers":[{"title":"Default Title","offer_id":47407009661152,"sku":"870012","price":1049.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/wireless-module-wm-6099-101565.jpg?v=1748137960"},{"product_id":"multi-parameter-turbidity-sensor","title":"Optical Turbidity Sensor - Fits Multi-Parameter Sonde","description":"\u003cdiv align=\"center\"\u003e\n\u003ch1 style=\"text-align: left;\"\u003eAdvanced Optical Turbidity Sensor is designed to fit the Multi-Parameter Sensor Housing.\u003c\/h1\u003e\n\u003cp style=\"text-align: left;\"\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cstrong style=\"color: rgb(255, 42, 0); font-size: 0.875rem;\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003eNotes\u003c\/span\u003e:\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003e1) This is for the SENSOR ONLY and requires use of the \u003ca href=\"https:\/\/sperdirect.com\/products\/multi-parameter-sonde-water-quality-sensor-housing\" rel=\"noopener\" target=\"_blank\"\u003eMulti-Parameter Sensor Housing\u003c\/a\u003e. \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: left;\"\u003e\u003cstrong\u003e2) The sensor housing can be connected to either the \u003ca href=\"https:\/\/sperdirect.com\/products\/portable-multi-parameter-water-quality-analyzer\"\u003ePortable Multi-Parameter Water Quality Analyzer\u003c\/a\u003e, or integrated with 3rd party data loggers or remote monitoring systems via \u003cspan class=\"Apple-converted-space\"\u003ebuilt-in \u003c\/span\u003eRS485 Modbus output.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: left;\"\u003e\u003cstrong\u003e3) This unit ships direct from the factory. Please allow an additional 5-10 working days for shipment and delivery.\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cspan style=\"font-size: 0.875rem;\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cstyle\u003e\n.sper-grid {\n  display: grid;\n  grid-template-columns: repeat(auto-fit, minmax(260px, 1fr));\n  gap: 20px;\n}\n\n.sper-card {\n  border: 1px solid #e5e5e5;\n  border-radius: 8px;\n  padding: 16px;\n  background: #fff;\n  transition: box-shadow 0.2s ease;\n  display: flex;\n  flex-direction: column;\n}\n\n.sper-card:hover {\n  box-shadow: 0 4px 12px rgba(0,0,0,0.08);\n}\n\n.sper-card img {\n  width: 100%;\n  height: auto;\n  margin-bottom: 12px;\n  display: block;\n}\n\n.sper-title {\n  font-size: 16px;\n  font-weight: 600;\n  margin-bottom: 6px;\n  line-height: 1.3;\n}\n\n.sper-desc {\n  font-size: 14px;\n  margin-bottom: 12px;\n  line-height: 1.4;\n  color: #444;\n}\n\n.sper-specs {\n  font-size: 13px;\n  line-height: 1.6;\n  margin-top: auto;\n}\n\n.sper-spec-row {\n  display: grid;\n  grid-template-columns: 120px 1fr;\n  gap: 6px;\n  margin-bottom: 2px;\n}\n\n.sper-spec-label {\n  font-weight: 600;\n  color: #222;\n}\n\n.sper-spec-value {\n  color: #333;\n}\n\u003c\/style\u003e\n\u003cdiv class=\"sper-grid\"\u003e\n\u003c!-- Turbidity --\u003e\n\u003cdiv class=\"sper-card\"\u003e\n\u003cdiv class=\"sper-title\"\u003eTurbidity Sensor\u003c\/div\u003e\n\u003cdiv class=\"sper-desc\"\u003eOptical turbidity sensor using light scattering for suspended solids measurement.\u003c\/div\u003e\n\u003cdiv class=\"sper-specs\"\u003e\n\u003cdiv class=\"sper-spec-row\"\u003e\n\u003cdiv class=\"sper-spec-label\"\u003ePrinciple\u003c\/div\u003e\n\u003cdiv class=\"sper-spec-value\"\u003eLight scattering\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"sper-spec-row\"\u003e\n\u003cdiv class=\"sper-spec-label\"\u003eRange\u003c\/div\u003e\n\u003cdiv class=\"sper-spec-value\"\u003e0–1000 NTU\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"sper-spec-row\"\u003e\n\u003cdiv class=\"sper-spec-label\"\u003eResolution\u003c\/div\u003e\n\u003cdiv class=\"sper-spec-value\"\u003e0.1 NTU\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"sper-spec-row\"\u003e\n\u003cdiv class=\"sper-spec-label\"\u003eAccuracy\u003c\/div\u003e\n\u003cdiv class=\"sper-spec-value\"\u003e±5%\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- ORP --\u003e\n\u003c\/div\u003e","brand":"Sper Scientific","offers":[{"title":"Default Title","offer_id":51364128882912,"sku":"870015-TU","price":1643.25,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/optical-turbidity-sensor-fits-multi-parameter-sonde-870015-tu-3469481.jpg?v=1793167090"},{"product_id":"orp-sensor-fits-multi-parameter-sensor-housing","title":"ORP Sensor - Fits Multi-Parameter Sonde","description":"\u003cdiv align=\"center\"\u003e\n\u003ch1 style=\"text-align: left;\"\u003eAdvanced ORP Sensor is designed to fit the Multi-Parameter Sensor Housing.\u003c\/h1\u003e\n\u003cp style=\"text-align: left;\"\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cstrong style=\"color: rgb(255, 42, 0); font-size: 0.875rem;\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003eNotes\u003c\/span\u003e:\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003e1) This is for the SENSOR ONLY and requires use of the \u003ca rel=\"noopener\" href=\"https:\/\/sperdirect.com\/products\/multi-parameter-sonde-water-quality-sensor-housing\" target=\"_blank\"\u003eMulti-Parameter Sensor Housing\u003c\/a\u003e. \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: left;\"\u003e\u003cstrong\u003e2) The sensor housing can be connected to either the \u003ca href=\"https:\/\/sperdirect.com\/products\/portable-multi-parameter-water-quality-analyzer\"\u003ePortable Multi-Parameter Water Quality Analyzer\u003c\/a\u003e, or integrated with 3rd party data loggers or remote monitoring systems via \u003cspan class=\"Apple-converted-space\"\u003ebuilt-in \u003c\/span\u003eRS485 Modbus output.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: left;\"\u003e\u003cstrong\u003e3) This unit ships direct from the factory. Please allow an additional 5-10 working days for shipment and delivery.\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cstyle\u003e\n.sper-grid {\n  display: grid;\n  grid-template-columns: repeat(auto-fit, minmax(260px, 1fr));\n  gap: 20px;\n}\n\n.sper-card {\n  border: 1px solid #e5e5e5;\n  border-radius: 8px;\n  padding: 16px;\n  background: #fff;\n  transition: box-shadow 0.2s ease;\n  display: flex;\n  flex-direction: column;\n}\n\n.sper-card:hover {\n  box-shadow: 0 4px 12px rgba(0,0,0,0.08);\n}\n\n.sper-card img {\n  width: 100%;\n  height: auto;\n  margin-bottom: 12px;\n  display: block;\n}\n\n.sper-title {\n  font-size: 16px;\n  font-weight: 600;\n  margin-bottom: 6px;\n  line-height: 1.3;\n}\n\n.sper-desc {\n  font-size: 14px;\n  margin-bottom: 12px;\n  line-height: 1.4;\n  color: #444;\n}\n\n.sper-specs {\n  font-size: 13px;\n  line-height: 1.6;\n  margin-top: auto;\n}\n\n.sper-spec-row {\n  display: grid;\n  grid-template-columns: 120px 1fr;\n  gap: 6px;\n  margin-bottom: 2px;\n}\n\n.sper-spec-label {\n  font-weight: 600;\n  color: #222;\n}\n\n.sper-spec-value {\n  color: #333;\n}\n\u003c\/style\u003e\n\u003cdiv class=\"sper-grid\"\u003e\n\u003c!-- ORP --\u003e\n\u003cdiv class=\"sper-card\"\u003e\n\u003cdiv class=\"sper-title\"\u003eORP Sensor\u003c\/div\u003e\n\u003cdiv class=\"sper-desc\"\u003eGlass electrode ORP sensor for oxidation-reduction monitoring.\u003c\/div\u003e\n\u003cdiv class=\"sper-specs\"\u003e\n\u003cdiv class=\"sper-spec-row\"\u003e\n\u003cdiv class=\"sper-spec-label\"\u003ePrinciple\u003c\/div\u003e\n\u003cdiv class=\"sper-spec-value\"\u003eGlass electrode\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"sper-spec-row\"\u003e\n\u003cdiv class=\"sper-spec-label\"\u003eRange\u003c\/div\u003e\n\u003cdiv class=\"sper-spec-value\"\u003e-1000 to 1000 mV\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"sper-spec-row\"\u003e\n\u003cdiv class=\"sper-spec-label\"\u003eResolution\u003c\/div\u003e\n\u003cdiv class=\"sper-spec-value\"\u003e0.1 mV\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"sper-spec-row\"\u003e\n\u003cdiv class=\"sper-spec-label\"\u003eAccuracy\u003c\/div\u003e\n\u003cdiv class=\"sper-spec-value\"\u003e±5 mV\u003c\/div\u003e\n\u003c\/div\u003e  \n\u003cdiv class=\"sper-spec-row\"\u003e\n\u003cdiv class=\"sper-spec-label\"\u003eTemp. Range\u003c\/div\u003e\n\u003cdiv class=\"sper-spec-value\"\u003e0–50°C\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Sper Scientific","offers":[{"title":"Default Title","offer_id":51375454486752,"sku":"870015-ORP","price":620.55,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/orp-sensor-fits-multi-parameter-sonde-870015-orp-7469415.jpg?v=1793167088"},{"product_id":"ph-sensor-fits-multi-parameter-sensor-housing","title":"pH Sensor - Fits Multi-Parameter Sonde","description":"\u003cdiv align=\"center\"\u003e\n\u003ch1 style=\"text-align: left;\"\u003eAdvanced pH Sensor is designed to fit the Multi-Parameter Sensor Housing.\u003c\/h1\u003e\n\u003cp style=\"text-align: left;\"\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cstrong style=\"color: rgb(255, 42, 0); font-size: 0.875rem;\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003eNotes\u003c\/span\u003e:\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003e1) This is for the SENSOR ONLY and requires use of the \u003ca href=\"https:\/\/sperdirect.com\/products\/multi-parameter-sonde-water-quality-sensor-housing\" rel=\"noopener\" target=\"_blank\"\u003eMulti-Parameter Sensor Housing\u003c\/a\u003e. \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: left;\"\u003e\u003cstrong\u003e2) The sensor housing can be connected to either the \u003ca href=\"https:\/\/sperdirect.com\/products\/portable-multi-parameter-water-quality-analyzer\"\u003ePortable Multi-Parameter Water Quality Analyzer\u003c\/a\u003e, or integrated with 3rd party data loggers or remote monitoring systems via \u003cspan class=\"Apple-converted-space\"\u003ebuilt-in \u003c\/span\u003eRS485 Modbus output.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: left;\"\u003e\u003cstrong\u003e3) This unit ships direct from the factory. Please allow an additional 5-10 working days for shipment and delivery.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: left;\"\u003e \u003c\/p\u003e\n\u003c\/div\u003e\n\u003cstyle\u003e\n.sper-grid {\n  display: grid;\n  grid-template-columns: repeat(auto-fit, minmax(260px, 1fr));\n  gap: 20px;\n}\n\n.sper-card {\n  border: 1px solid #e5e5e5;\n  border-radius: 8px;\n  padding: 16px;\n  background: #fff;\n  transition: box-shadow 0.2s ease;\n  display: flex;\n  flex-direction: column;\n}\n\n.sper-card:hover {\n  box-shadow: 0 4px 12px rgba(0,0,0,0.08);\n}\n\n.sper-card img {\n  width: 100%;\n  height: auto;\n  margin-bottom: 12px;\n  display: block;\n}\n\n.sper-title {\n  font-size: 16px;\n  font-weight: 600;\n  margin-bottom: 6px;\n  line-height: 1.3;\n}\n\n.sper-desc {\n  font-size: 14px;\n  margin-bottom: 12px;\n  line-height: 1.4;\n  color: #444;\n}\n\n.sper-specs {\n  font-size: 13px;\n  line-height: 1.6;\n  margin-top: auto;\n}\n\n.sper-spec-row {\n  display: grid;\n  grid-template-columns: 120px 1fr;\n  gap: 6px;\n  margin-bottom: 2px;\n}\n\n.sper-spec-label {\n  font-weight: 600;\n  color: #222;\n}\n\n.sper-spec-value {\n  color: #333;\n}\n\u003c\/style\u003e\n\u003c!-- pH --\u003e\n\u003cdiv class=\"sper-card\"\u003e\n\u003cdiv class=\"sper-title\"\u003epH Sensor\u003c\/div\u003e\n\u003cdiv class=\"sper-desc\"\u003eHigh-accuracy glass electrode pH sensor for continuous monitoring.\u003c\/div\u003e\n\u003cdiv class=\"sper-specs\"\u003e\n\u003cdiv class=\"sper-spec-row\"\u003e\n\u003cdiv class=\"sper-spec-label\"\u003ePrinciple\u003c\/div\u003e\n\u003cdiv class=\"sper-spec-value\"\u003eGlass electrode\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"sper-spec-row\"\u003e\n\u003cdiv class=\"sper-spec-label\"\u003eRange\u003c\/div\u003e\n\u003cdiv class=\"sper-spec-value\"\u003e0–14 pH\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"sper-spec-row\"\u003e\n\u003cdiv class=\"sper-spec-label\"\u003eResolution\u003c\/div\u003e\n\u003cdiv class=\"sper-spec-value\"\u003e0.01 pH\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"sper-spec-row\"\u003e\n\u003cdiv class=\"sper-spec-label\"\u003eAccuracy\u003c\/div\u003e\n\u003cdiv class=\"sper-spec-value\"\u003e±0.1 pH\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Sper Scientific","offers":[{"title":"Default Title","offer_id":51416361631968,"sku":"870015-PH","price":677.25,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/ph-sensor-fits-multi-parameter-sonde-870015-ph-2937860.jpg?v=1793167088"},{"product_id":"conductivity-salinity-sensor-fits-multi-parameter-sensor-housing","title":"Conductivity\/Salinity Sensor - Fits Multi-Parameter Sonde","description":"\u003cdiv align=\"center\"\u003e\n\u003ch1 style=\"text-align: left;\"\u003eAdvanced Conductivity\/Salinity Sensor is designed to fit the Multi-Parameter Sensor Housing.\u003c\/h1\u003e\n\u003cp style=\"text-align: left;\"\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cstrong style=\"color: rgb(255, 42, 0); font-size: 0.875rem;\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003eNotes\u003c\/span\u003e:\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003e1) This is for the SENSOR ONLY and requires use of the \u003ca href=\"https:\/\/sperdirect.com\/products\/multi-parameter-sonde-water-quality-sensor-housing\" rel=\"noopener\" target=\"_blank\"\u003eMulti-Parameter Sensor Housing\u003c\/a\u003e. \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: left;\"\u003e\u003cstrong\u003e2) The sensor housing can be connected to either the \u003ca href=\"https:\/\/sperdirect.com\/products\/portable-multi-parameter-water-quality-analyzer\"\u003ePortable Multi-Parameter Water Quality Analyzer\u003c\/a\u003e, or integrated with 3rd party data loggers or remote monitoring systems via \u003cspan class=\"Apple-converted-space\"\u003ebuilt-in \u003c\/span\u003eRS485 Modbus output.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: left;\"\u003e\u003cstrong\u003e3) This unit ships direct from the factory. Please allow an additional 5-10 working days for shipment and delivery.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: left;\"\u003e \u003c\/p\u003e\n\u003c\/div\u003e\n\u003cstyle\u003e\n.sper-grid {\n  display: grid;\n  grid-template-columns: repeat(auto-fit, minmax(260px, 1fr));\n  gap: 20px;\n}\n\n.sper-card {\n  border: 1px solid #e5e5e5;\n  border-radius: 8px;\n  padding: 16px;\n  background: #fff;\n  transition: box-shadow 0.2s ease;\n  display: flex;\n  flex-direction: column;\n}\n\n.sper-card:hover {\n  box-shadow: 0 4px 12px rgba(0,0,0,0.08);\n}\n\n.sper-card img {\n  width: 100%;\n  height: auto;\n  margin-bottom: 12px;\n  display: block;\n}\n\n.sper-title {\n  font-size: 16px;\n  font-weight: 600;\n  margin-bottom: 6px;\n  line-height: 1.3;\n}\n\n.sper-desc {\n  font-size: 14px;\n  margin-bottom: 12px;\n  line-height: 1.4;\n  color: #444;\n}\n\n.sper-specs {\n  font-size: 13px;\n  line-height: 1.6;\n  margin-top: auto;\n}\n\n.sper-spec-row {\n  display: grid;\n  grid-template-columns: 120px 1fr;\n  gap: 6px;\n  margin-bottom: 2px;\n}\n\n.sper-spec-label {\n  font-weight: 600;\n  color: #222;\n}\n\n.sper-spec-value {\n  color: #333;\n}\n\u003c\/style\u003e\n\u003c!-- Conductivity --\u003e\n\u003cdiv class=\"sper-card\"\u003e\n\u003cdiv class=\"sper-title\"\u003eConductivity \/ Salinity Sensor\u003c\/div\u003e\n\u003cdiv class=\"sper-desc\"\u003eDual-range conductivity sensor for freshwater and high-salinity environments.\u003c\/div\u003e\n\u003cdiv class=\"sper-specs\"\u003e\n\u003cdiv class=\"sper-spec-row\"\u003e\n\u003cdiv class=\"sper-spec-label\"\u003ePrinciple\u003c\/div\u003e\n\u003cdiv class=\"sper-spec-value\"\u003ePlatinum electrode\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"sper-spec-row\"\u003e\n\u003cdiv class=\"sper-spec-label\"\u003eRange\u003c\/div\u003e\n\u003cdiv class=\"sper-spec-value\"\u003e1–2000 µS\/cm, 100 µS\/cm–100 mS\/cm\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"sper-spec-row\"\u003e\n\u003cdiv class=\"sper-spec-label\"\u003eResolution\u003c\/div\u003e\n\u003cdiv class=\"sper-spec-value\"\u003e0.1 µS\/cm–0.01 mS\/cm\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"sper-spec-row\"\u003e\n\u003cdiv class=\"sper-spec-label\"\u003eAccuracy\u003c\/div\u003e\n\u003cdiv class=\"sper-spec-value\"\u003e±3%\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Sper Scientific","offers":[{"title":"Default Title","offer_id":51416366612704,"sku":"870015-CS","price":677.25,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/conductivitysalinity-sensor-fits-multi-parameter-sonde-870015-cs-6017359.jpg?v=1793167087"},{"product_id":"online-universal-water-quality-transmitter","title":"Online Universal Water Quality Transmitter","description":"\u003ch1\u003eUniversal Transmitter provides continuous online water quality monitoring when paired with a compatible BOQU digital sensor. \u003c\/h1\u003e\n\u003cp\u003e\u003cstrong\u003eConfigurations support pH, ORP, residual chlorine, dissolved oxygen, turbidity or suspended solids, with temperature measurement available where supported by the selected sensor.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDesigned for panel installation, the DA800 combines a 3.1-inch backlit LCD and five-button interface with two 4–20 mA outputs and RS485 Modbus RTU communication. These interfaces support connection to PLCs and plant monitoring systems, while three relays provide high alarm, low alarm and cleaning control functions.\u003c\/p\u003e\n\u003cp\u003eHistorical data logging supports adjustable recording intervals from 1–999 minutes. Stored readings can be viewed on the instrument or exported to a computer in CSV format through the USB Type-C port. A maintenance mode holds the 4–20 mA and RS485 output values during service, while simulation functions help check current outputs and relay operation.\u003c\/p\u003e\n\u003cp\u003eThe IP65-rated ABS housing and 4 W power consumption suit fixed monitoring installations in water treatment, wastewater treatment, industrial process water, aquaculture and biological fermentation. The standard power configuration accepts 100–240 VAC; a 24 VDC version is optional.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCompatible with supported Sper Scientific digital sensors for multiple water quality applications\u003c\/li\u003e\n\u003cli\u003e3.1-inch backlit LCD with measurement, status, date and time display\u003c\/li\u003e\n\u003cli\u003eDual 4–20 mA outputs and RS485 Modbus RTU communication\u003c\/li\u003e\n\u003cli\u003eThree relays for high alarm, low alarm and cleaning control\u003c\/li\u003e\n\u003cli\u003eHistorical data recording with adjustable storage intervals\u003c\/li\u003e\n\u003cli\u003eCSV data export through USB Type-C\u003c\/li\u003e\n\u003cli\u003eMaintenance mode holds output values during service\u003c\/li\u003e\n\u003cli\u003eCurrent output and relay simulation for system checks\u003c\/li\u003e\n\u003cli\u003ePower-loss data retention\u003c\/li\u003e\n\u003cli\u003eIP65-rated ABS enclosure for panel mounting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"text-align: left;\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e\u003cstrong\u003e870016\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eSupported parameters\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003epH, ORP, residual chlorine, dissolved oxygen, turbidity, suspended solids and temperature; configuration depends on the connected sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eDisplay\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e3.1-inch backlit digital LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eHousing\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003eABS plastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eStandard power supply\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e100–240 VAC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eOptional power supply\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003ePower consumption\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e4 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eAnalog outputs\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003eTwo 4–20 mA outputs; functions depend on sensor configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eDigital communication\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003eRS485, Modbus RTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eRelays\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003eThree; high alarm, low alarm and cleaning control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eRelay contact rating\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e5 A at 250 VAC or 5 A at 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eData logging interval\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003eAdjustable from 1–999 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eData export\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003eUSB Type-C connection to a computer; CSV export\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eDimensions\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e144 × 144 × 104 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e0.9 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eProtection rating\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eOperating environment\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e−20 to 50°C; ≤95% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eStorage environment\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e−40 to 70°C; ≤95% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eMaximum operating altitude\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e2,000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eOvervoltage category \/ pollution degree\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003eII \/ 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSensor-dependent measurement ranges\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"text-align: left;\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003epH\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e0–14 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eORP\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e−2,000 to +2,000 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eResidual chlorine\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e0–5 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eDissolved oxygen\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e0–25 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eTurbidity\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e0–4,000 NTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eSuspended solids\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e0–120,000 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThese ranges describe the controller's supported configurations. Actual range, accuracy, temperature capability and process limits depend on the selected electrode or sensor. The transmitter does not measure every listed parameter simultaneously.\u003c\/p\u003e\n\u003ch4\u003eDownloads\u003c\/h4\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cstrong\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/800002-i.pdf?v=1598908085\" target=\"_blank\"\u003e \u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/DA800_Universal_Transmitter_Manual.pdf\" title=\"Sper 870016 Users Manual\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/pdf-icon-63x63_480x480.png?v=1598991821\" style=\"float: left;\" alt=\"PDF\"\u003e\u003c\/a\u003e \u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/DA800_Universal_Transmitter_Manual.pdf\" title=\"Sper 870016 Users Manual\" rel=\"noopener\" target=\"_blank\"\u003eSper 870016 Instruction Manual\u003c\/a\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003eFAQs\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the DA800 measure all listed parameters at once?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. Supported measurements and menu functions depend on the connected sensor and selected configuration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan it connect to a PLC?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. It provides RS485 Modbus RTU communication and two 4–20 mA outputs.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I export recorded readings?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. Stored data can be copied to a computer in CSV format over USB. Logging pauses while the USB connection is active and resumes after disconnection.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes every sensor configuration measure temperature?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The manual states that turbidity and suspended solids configurations do not provide the temperature setting function. Check the selected sensor's capabilities.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat power supply is required?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe standard version uses 100–240 VAC at 50\/60 Hz. A 24 VDC version is optional.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat determines measurement accuracy?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAccuracy and usable measurement range depend on the compatible sensor selected. Refer to that sensor's specifications and calibration requirements.\u003c\/p\u003e","brand":"Sper Scientific","offers":[{"title":"Default Title","offer_id":68103962591456,"sku":"870016","price":997.5,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/online-universal-water-quality-transmitter-870016-2499980.jpg?v=1793360781"},{"product_id":"sper-scientific-ph-conductivity-dual-channel-online-analyzer","title":"Online Dual-Channel pH\/Conductivity Analyzer","description":"\u003ch1\u003eSper Scientific Online pH\/Conductivity Analyzer monitors one analog pH or ORP sensor and one analog conductivity sensor simultaneously.\u003c\/h1\u003e\n\u003cp\u003e\u003cstrong\u003eIt combines two measurement channels in a compact panel-mounted instrument for continuous water quality monitoring in industrial processes, water treatment and wastewater applications.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe pH\/ORP channel supports acidity or oxidation-reduction potential measurement, while the conductivity channel provides conductivity, TDS, salinity or resistivity readings. Temperature measurement and compensation support consistent process evaluation when used with compatible probes. Actual measurement range, process temperature limits and overall system performance depend on the sensors selected.\u003c\/p\u003e\n\u003cp\u003eA 3.1-inch backlit LCD displays process readings, while the front-panel buttons provide access to measurement and output settings. Two configurable 4–20 mA outputs and RS485 Modbus RTU communication support integration with PLCs and plant monitoring systems. Three relay outputs provide alarm and supported control functions.\u003c\/p\u003e\n\u003cp\u003eHistorical data records and trend curves help review process changes. Recording intervals can be set from 1–999 minutes, and stored data can be exported to a computer over USB. The ABS enclosure has an IP65 protection rating, with standard 100–240 VAC power and an optional 24 VDC configuration.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSimultaneous pH\/ORP and conductivity monitoring with compatible analog sensors\u003c\/li\u003e\n\u003cli\u003eConductivity-channel functions include EC, TDS, salinity and resistivity\u003c\/li\u003e\n\u003cli\u003eTemperature compensation with multiple supported temperature sensor types\u003c\/li\u003e\n\u003cli\u003e3.1-inch backlit LCD and front-panel controls\u003c\/li\u003e\n\u003cli\u003eTwo configurable 4–20 mA outputs\u003c\/li\u003e\n\u003cli\u003eRS485 Modbus RTU communication for PLC integration\u003c\/li\u003e\n\u003cli\u003eThree relay outputs for alarm and supported control functions\u003c\/li\u003e\n\u003cli\u003eHistorical data logging and trend curve display\u003c\/li\u003e\n\u003cli\u003eAdjustable data recording intervals from 1–999 minutes\u003c\/li\u003e\n\u003cli\u003eUSB export of stored records\u003c\/li\u003e\n\u003cli\u003eIP65-rated ABS enclosure\u003c\/li\u003e\n\u003cli\u003eStandard AC power with an optional 24 VDC version\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"text-align: left;\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e870002D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eMeasurement channels\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003eOne analog pH\/ORP sensor and one analog conductivity sensor, operating simultaneously\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003epH range\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e−2.00 to 16.00 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eORP range\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e−2,000 to +2,000 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eConductivity range\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e0–2,000,000 µS\/cm (0–2,000 mS\/cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eTDS range\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e0–130,000 mg\/L (ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eResistivity range\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e0–20 MΩ·cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eSalinity\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003eSupported; usable range depends on sensor and configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eChannel 1 temperature range\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e−30.0 to 130.0°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eChannel 2 temperature range\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e−40.0 to 200.0°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003epH: ±0.01 pH; ORP: ±1 mV; conductivity: ±2%; temperature: ±0.5°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eTemperature compensation inputs\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003eNTC30k, NTC22k, NTC10k, Pt1000 and NTC2.252k\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eDisplay\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e3.1-inch backlit digital LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eAnalog outputs\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003eTwo configurable 4–20 mA outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eDigital interface\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003eRS485, Modbus RTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eRelays\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003eThree; contacts rated 5 A at 250 VAC or 5 A at 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eData logging\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003eHistorical records and curves; adjustable recording interval 1–999 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eData export\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003eUSB connection to computer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eStandard power\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e100–240 VAC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eOptional power\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003ePower consumption\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e4 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eHousing \/ protection\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003eABS plastic \/ IP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eDimensions \/ weight\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e144 × 144 × 104 mm \/ 0.9 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eOperating environment\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e−20 to 50°C; ≤95% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eStorage environment\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e−40 to 70°C; ≤95% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eAltitude \/ overvoltage category \/ pollution degree\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e≤2,000 m \/ II \/ 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eLanguages\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003eEnglish, Simplified Chinese, Traditional Chinese and Russian\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eCountry of origin\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003eChina\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eListed measurement limits are controller capabilities. Select compatible electrodes with ranges, temperature ratings and process connections appropriate for the application.\u003c\/p\u003e\n\u003ch4\u003eDownloads\u003c\/h4\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cstrong\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/800002-i.pdf?v=1598908085\" target=\"_blank\"\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/pdf-icon-63x63_480x480.png?v=1598991821\" style=\"float: left;\" alt=\"PDF\"\u003e \u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/800002-i.pdf?v=1598908085\" target=\"_blank\"\u003e\u003cbr\u003eSper Scientific 870002D Instruction Manual\u003c\/a\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003eFAQs\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eCan the DCA130 measure pH and conductivity at the same time?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. It supports one pH\/ORP sensor and one conductivity sensor simultaneously.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan it measure pH and ORP simultaneously?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe first channel uses a pH or ORP sensor. The second channel is intended for conductivity measurements.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat measurements are available on the conductivity channel?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eConductivity, TDS, salinity and resistivity functions are supported. Available ranges depend on the electrode and configuration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan it connect to a PLC?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The analyzer provides RS485 Modbus RTU and two configurable 4–20 mA outputs.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan historical readings be exported?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. Stored data can be exported to a computer over USB. Logging pauses while the USB connection is active and resumes after disconnection.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAre sensors included?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSensor inclusion has not been specified. Select the required pH\/ORP and conductivity probes for your installation and confirm the package before ordering.\u003c\/p\u003e","brand":"Sper Scientific","offers":[{"title":"Default Title","offer_id":68104970076384,"sku":"870002D","price":947.5,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/online-dual-channel-phconductivity-analyzer-870002d-1476214.jpg?v=1793360781"},{"product_id":"online-multi-parameter-water-quality-analyzer","title":"Online Multi-Parameter Water Quality Analyzer","description":"\u003ch1\u003eThe Sper Scientific 870001S Multi-Parameter Water Quality Analyzer combines online pH, residual chlorine, turbidity and temperature monitoring in an integrated cabinet.\u003c\/h1\u003e\n\u003cp\u003eDesigned for waterworks, municipal water supply and drinking water monitoring in public facilities, it brings key water quality measurements together in one installation.\u003c\/p\u003e\n\u003cp\u003eThe compact cabinet simplifies equipment placement and reduces the space required for a monitoring station. A front-mounted display provides access to process information, while the internal arrangement groups the measurement components, sample tubing and connections for service access. Online monitoring and stored data help operators review water quality conditions and changes over time.\u003c\/p\u003e\n\u003cp\u003eRS485 communication supports connection to compatible monitoring equipment. The system is intended for water supply applications under normal temperature and pressure conditions. Parameter customization is available at the product-family level; confirm the required sensors and configuration for the installation before ordering.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIntegrated online monitoring of pH, residual chlorine, turbidity and temperature\u003c\/li\u003e\n\u003cli\u003eCabinet-based design simplifies transportation and installation\u003c\/li\u003e\n\u003cli\u003eFront-mounted display for water quality information\u003c\/li\u003e\n\u003cli\u003eOnline data monitoring and storage\u003c\/li\u003e\n\u003cli\u003eRS485 communication interface\u003c\/li\u003e\n\u003cli\u003eAccessible internal measurement components and sample connections\u003c\/li\u003e\n\u003cli\u003eCompact 400 × 600 × 220 mm cabinet\u003c\/li\u003e\n\u003cli\u003eSuitable for waterworks, municipal supply and drinking water monitoring stations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"text-align: left;\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003ePart number\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e870001S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eMeasurement parameters\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003epH, residual chlorine, turbidity and temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003epH range \/ resolution \/ accuracy\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e0–14.00 pH \/ 0.01 pH \/ ±0.1 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eResidual chlorine range \/ resolution \/ accuracy\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e0–2.00 mg\/L \/ 0.01 mg\/L \/ ±3% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eTurbidity range \/ resolution\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e0–2.00 NTU \/ 0.01 NTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eTurbidity accuracy\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e±2% or ±0.02 NTU, whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eTemperature range \/ resolution \/ accuracy\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e0–60°C \/ 0.1°C \/ ±0.5°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eCommunication interface\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003eRS485\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003ePower supply\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e220 VAC ±10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eOperating ambient temperature\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e0–50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eHumidity condition\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e≤85% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eCabinet dimensions\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e400 × 600 × 220 mm (L × H × W)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"Sper Scientific","offers":[{"title":"Default Title","offer_id":68119237656800,"sku":"870001S","price":4300.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/online-multi-parameter-water-quality-analyzer-870001s-3724419.jpg?v=1793360780"},{"product_id":"online-dpd-colorimetry-chlorine-analyzer","title":"Online DPD Colorimetry Chlorine Analyzer","description":"\u003ch1\u003eThe Sper Scientific 870017 DPD Colorimetry Chlorine Analyzer measures residual chlorine online for drinking water and disinfection processes.\u003c\/h1\u003e\n\u003cp\u003eOnline monitoring system designed for drinking water and disinfection processes to continuously measure free and total residual chlorine using the DPD colorimetric method.\u003cstrong\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDPD Colorimetry Analysis is a standard method for detecting free residual chlorine and total residual chlorine. Automatic reagent dosing and calibration supports routine monitoring, while the touchscreen provides access to measurements, settings and records. Connect the analyzer to process controls through analog and digital outputs. Stored measurement and calibration records can be exported to a USB drive for review. \u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDPD Colorimetry Analysis\u003c\/li\u003e\n\u003cli\u003eAutomatic or manual measurement\u003c\/li\u003e\n\u003cli\u003eAutomatic reagent addition and calibration\u003c\/li\u003e\n\u003cli\u003eColor touchscreen with English language support\u003c\/li\u003e\n\u003cli\u003eUSB export of historical data\u003c\/li\u003e\n\u003cli\u003eAnalog output, digital communication and configurable alarm relays\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003ePart number\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e870017\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eMethod\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003eDPD colorimetry\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eRange\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e0–5.00 mg\/L (ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eAccuracy\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e±5% of reading or ±0.03 mg\/L, whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eResolution\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e0.01 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eAnalysis time\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e180 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eDefault measurement interval\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e600 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eDisplay\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e4.3-inch color LCD touchscreen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eAnalog output\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e4–20 mA; maximum load 500 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eDigital communication\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003eRS485, Modbus RTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eRelays\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003eTwo adjustable high\/low alarm contacts with hysteresis; 5 A at 250 VAC or 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003ePower\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e100–240 VAC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eSample temperature\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e5–40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eOperating environment\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e5–40°C; ≤95% RH, noncondensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eDimensions\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e500 × 400 × 200 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eWeight\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e6.5 kg without reagents\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eReagent capacity\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003eTwo 1,000 mL bottles; approximately 5,000 measurements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eCountry of origin\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003eChina\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003eFAQs\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eWhat does it measure?\u003c\/strong\u003e\u003cbr\u003eResidual chlorine using the DPD colorimetric method.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan it connect to a control system?\u003c\/strong\u003e\u003cbr\u003eYes, through the outputs and relay contacts listed above.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAre reagents required?\u003c\/strong\u003e\u003cbr\u003eYes. Reagent dosing is part of the measurement process. Package contents require confirmation.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"Sper Scientific","offers":[{"title":"Default Title","offer_id":68122345373920,"sku":"870017","price":4300.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/online-dpd-colorimetry-chlorine-analyzer-870017-7205495.jpg?v=1793360779"},{"product_id":"online-industrial-orp-sensor","title":"Online Industrial ORP Sensor","description":"\u003ch1\u003eThe Sper Scientific Industrial ORP Sensor monitors oxidation-reduction potential in water and process solutions.\u003c\/h1\u003e\n\u003cp\u003e\u003cstrong\u003eDesigned for use with compatible ORP monitoring equipment, the sensor helps operators track redox conditions in applications such as water treatment, wastewater processing, cooling water and industrial chemical processes.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe platinum sensing element is paired with a solid reference electrolyte and a large-area PTFE junction. Upper and lower 3\/4-inch NPT threads provide installation options, while a direct-connected low-noise cable carries the sensor signal.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eORP measurement from −2,000 to +2,000 mV\u003c\/li\u003e\n\u003cli\u003ePlatinum sensing element\u003c\/li\u003e\n\u003cli\u003eSolid reference electrolyte and PTFE junction\u003c\/li\u003e\n\u003cli\u003eUpper and lower threaded connections\u003c\/li\u003e\n\u003cli\u003eDirect-connected low-noise cable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003ePart number\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e\u003cstrong\u003e870002-ORP\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eMeasurement\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003eOxidation-reduction potential (ORP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eORP range\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e−2,000 to +2,000 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eTemperature range\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e0–60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003ePressure rating\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e0.6 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eBody material\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003ePPS\/PC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eSensing element\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003ePlatinum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eReference junction\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003ePTFE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eProcess connection\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003eUpper and lower 3\/4-inch NPT threads\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eCable\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003eDirect-connected low-noise cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003e\u003c\/h4\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Sper Scientific","offers":[{"title":"Default Title","offer_id":68288733970656,"sku":"870002-ORP","price":175.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/online-industrial-orp-sensor-870002-orp-2854675.jpg?v=1793360775"},{"product_id":"industrial-glass-ph-electrode","title":"Online Industrial Glass pH Electrode - Waste Water (PTFE)","description":"\u003ch1\u003eThe Industrial Glass pH electrode supports continuous online monitoring in wastewater and environmental applications.\u003c\/h1\u003e\n\u003cp\u003eThis cable-connected combination electrode features a low-resistance sensing membrane and a ceramic-infiltrated sand core junction. Its pressure-resistant design is suited to industrial pH measurement and long-term online monitoring.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMeasures pH from 0 to 14\u003c\/li\u003e\n\u003cli\u003eCable-type connection\u003c\/li\u003e\n\u003cli\u003eLow-resistance glass sensing membrane\u003c\/li\u003e\n\u003cli\u003eCeramic-infiltrated sand core junction\u003c\/li\u003e\n\u003cli\u003eDesigned for environmental and wastewater monitoring\u003c\/li\u003e\n\u003cli\u003eCan be used with a 316L stainless steel or PPS sheath\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cmeta charset=\"utf-8\"\u003e870002-PHG1\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH range\u003c\/td\u003e\n\u003ctd\u003e0–14 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature range\u003c\/td\u003e\n\u003ctd\u003e0–80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure resistance\u003c\/td\u003e\n\u003ctd\u003e0.3 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection type\u003c\/td\u003e\n\u003ctd\u003eCable type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJunction material\u003c\/td\u003e\n\u003ctd\u003eCeramic-infiltrated sand core\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eEnvironmental protection and wastewater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Sper Scientific","offers":[{"title":"Default Title","offer_id":68290605875424,"sku":"870002-PHG1","price":150.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/online-industrial-glass-ph-electrode-waste-water-ptfe-870002-phg1-4359559.png?v=1793360775"},{"product_id":"online-industrial-pressure-sensor-0-100-mpa-4-20-ma","title":"Online Industrial Pressure Sensor, 0–100 MPa, 4–20 mA","description":"\u003ch1\u003eHigh-Accuracy Industrial Pressure Measurement for Water Treatment and Process Control\u003c\/h1\u003e\n\u003cp\u003eThe Sper Scientific 870023-PS Pressure Sensor is an industrial silicon pressure transmitter designed for monitoring compatible liquids in water treatment, wastewater and industrial process applications. Its 316L stainless steel wetted parts, 4–20 mA output and rugged stainless steel housing support reliable integration with process control systems.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePressure measurement range: 0–100 MPa\u003c\/li\u003e\n\u003cli\u003eAccuracy: ±0.25% FSO\u003c\/li\u003e\n\u003cli\u003e4–20 mA analog output with 24 VDC supply\u003c\/li\u003e\n\u003cli\u003e316L stainless steel wetted parts and silicon pressure membrane\u003c\/li\u003e\n\u003cli\u003e200% FS overload pressure and 250% FS burst pressure\u003c\/li\u003e\n\u003cli\u003eDIN 43650 electrical connector and IP65 protection\u003c\/li\u003e\n\u003cli\u003eBSP 1\/4-inch male process connection or customized connection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eIndustrial automation, water and wastewater treatment, chemical processing and compatible liquid pressure monitoring.\u003c\/p\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eProduct\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e\u003cstrong\u003eSper 870023-PS Pressure Sensor\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eMeasurement media\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003eLiquids compatible with 316L stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eMeasuring range\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e0–100 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eOverload pressure\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e200% FS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eBurst pressure\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e250% FS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003ePower supply\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eOutput signal\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e4–20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eZero offset\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e1% FSO maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eAccuracy\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e±0.25% FSO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eLong-term zero stability\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e0.15% FSO\/year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eLoad resistance\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e250–1150 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eStorage temperature\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e−30 to +80°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eOperating temperature\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e−40 to +120°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eProcess connection\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003eBSP 1\/4-inch male or customized\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eElectrical connection\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003eDIN 43650\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eEnvironmental protection\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003ePressure membrane\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003eSilicon\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eWetted parts\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e316L stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eHousing\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e304 stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Sper Scientific","offers":[{"title":"Default Title","offer_id":68312327192800,"sku":"870023-PS","price":237.5,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/online-industrial-pressure-sensor-0-100-mpa-4-20-ma-870023-ps-5901014.jpg?v=1793360774"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/collections\/collection-pools-and-spas.jpg?v=1793388562","url":"https:\/\/sper-direct.myshopify.com\/collections\/pools-and-spas.oembed","provider":"Sper Scientific Direct","version":"1.0","type":"link"}