{"title":"Power Plants","description":"\u003cp\u003e\u003cstrong\u003ePower plant measurement instruments help operators monitor water chemistry and equipment conditions throughout the facility.\u003c\/strong\u003e Reliable measurements support routine checks of makeup water, boiler feedwater, condensate and other plant systems.\u003c\/p\u003e\u003cp\u003eExplore online analyzers, sensors and inspection instruments for power generation applications. Choose equipment suited to the required measurement range, process conditions and monitoring method.\u003c\/p\u003e","products":[{"product_id":"ultrasonic-level-meter","title":"Integrated Ultrasonic Level Meter","description":"\u003ch1\u003eThe Ultrasonic Level Meter combines the strengths of various level measurement instruments into a fully digital and user-friendly system.\u003c\/h1\u003e\n\u003cp\u003eIt offers reliable level monitoring, seamless data transmission, and intuitive human-machine interaction. With robust anti-interference capabilities, customizable upper and lower limits, and online output adjustments, it supports on-site display and multiple output options, including analog, switching and RS485 for easy integration with control systems. \u003c\/p\u003e\n\u003cp\u003eConstructed with a waterproof engineering plastic cover and ABS probe, it suits diverse level measurement applications. Additional modules like RS485 and current output can be added for enhanced compatibility with PLCs. Key features include wide DC12-24V voltage range, parameter backup and recovery, flexible analog output adjustment, filter settings to eliminate noise, customizable serial data formats, and adjustable pulse intensity for measuring air gaps or liquid levels.\u003c\/p\u003e\n\u003cp class=\"p1\"\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli class=\"p1\"\u003eDC12-24V wide work voltage\u003c\/li\u003e\n\u003cli class=\"p1\"\u003eBackup and recovery parameter set\u003c\/li\u003e\n\u003cli class=\"p1\"\u003eFree adjustment of the range of analog output\u003c\/li\u003e\n\u003cli class=\"p1\"\u003eSet a filter value to remove\u003c\/li\u003e\n\u003cli class=\"p1\"\u003eCustom serial port data format\u003c\/li\u003e\n\u003cli class=\"p1\"\u003eMeasure measure air space or liquid level\u003c\/li\u003e\n\u003cli class=\"p1\"\u003e1-15 transmitted pulse intensity depending on working conditions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003eOrdering Notes:\u003cbr\u003e\u003c\/b\u003e\u003cb\u003e\u003cspan\u003e\u003cspan style=\"color: #ff2a00;\"\u003eAll Inline Water Quality Meters and Sensors ship direct from the factory. Please allow 10-15 business days for shipping and \u003cspan style=\"caret-color: rgb(255, 42, 0);\"\u003ehandling\u003c\/span\u003e. \u003c\/span\u003e\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable style=\"border-collapse: collapse; width: 654pt; box-sizing: border-box; outline: 0px; border-spacing: 0px; font-variant-ligatures: normal; font-variant-caps: normal; orphans: 2; widows: 2; -webkit-text-stroke-width: 0px; text-decoration-thickness: initial; text-decoration-style: initial; text-decoration-color: initial; height: 301px;\" width=\"872\" cellspacing=\"0\" cellpadding=\"0\" border=\"0\"\u003e\n\u003ccolgroup\u003e \u003ccol style=\"width: 296px;\" width=\"296\"\u003e \u003ccol style=\"width: 575px;\" width=\"576\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 24px; box-sizing: border-box; outline: 0px;\" height=\"24\"\u003e\n\u003ctd style=\"height: 24px; width: 222pt; box-sizing: border-box; outline: 0px;\" width=\"296\" class=\"xl63\" height=\"24\"\u003e\u003cspan style=\"box-sizing: border-box; outline: 0px;\"\u003eRange\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 432pt; box-sizing: border-box; outline: 0px; height: 24px;\" width=\"576\" class=\"xl63\"\u003e\u003cspan style=\"box-sizing: border-box; outline: 0px;\"\u003e5, 8, 10, 12, 15m\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 13px;\"\u003e\n\u003ctd style=\"box-sizing: border-box; outline: 0px; height: 13px;\"\u003e\u003cspan style=\"box-sizing: border-box; outline: 0px; height: 13px;\"\u003eAccuracy\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"box-sizing: border-box; outline: 0px; height: 13px;\"\u003e±0.3%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 24px; box-sizing: border-box; outline: 0px;\" height=\"24\"\u003e\n\u003ctd style=\"height: 24px; box-sizing: border-box; outline: 0px;\" class=\"xl63\" height=\"24\"\u003e\u003cspan style=\"box-sizing: border-box; outline: 0px;\"\u003eBlind Zone\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"box-sizing: border-box; outline: 0px; height: 24px;\" class=\"xl64\"\u003e\u003cspan style=\"box-sizing: border-box; outline: 0px;\"\u003e＜\u003cspan class=\"font5\"\u003e0.3-0.5m (different for range)\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 24px; box-sizing: border-box; outline: 0px;\" height=\"24\"\u003e\n\u003ctd style=\"height: 24px; box-sizing: border-box; outline: 0px;\" class=\"xl63\" height=\"24\"\u003e\u003cspan style=\"box-sizing: border-box; outline: 0px;\"\u003eDisplay resolution\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"box-sizing: border-box; outline: 0px; height: 24px;\" class=\"xl63\"\u003e\u003cspan style=\"box-sizing: border-box; outline: 0px;\"\u003e1mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 24px; box-sizing: border-box; outline: 0px;\" height=\"24\"\u003e\n\u003ctd style=\"height: 24px; box-sizing: border-box; outline: 0px;\" class=\"xl63\" height=\"24\"\u003e\u003cspan style=\"box-sizing: border-box; outline: 0px;\"\u003eFrequency\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"box-sizing: border-box; outline: 0px; height: 24px;\" class=\"xl63\"\u003e\u003cspan style=\"box-sizing: border-box; outline: 0px;\"\u003e20~350KHz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 24px; box-sizing: border-box; outline: 0px;\" height=\"24\"\u003e\n\u003ctd style=\"height: 24px; box-sizing: border-box; outline: 0px;\" class=\"xl63\" height=\"24\"\u003e\u003cspan style=\"box-sizing: border-box; outline: 0px;\"\u003ePower\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"box-sizing: border-box; outline: 0px; height: 24px;\" class=\"xl63\"\u003e\u003cspan style=\"box-sizing: border-box; outline: 0px;\"\u003e12-24VDC; consumption:\u0026lt;1.5W\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 24px; box-sizing: border-box; outline: 0px;\" height=\"24\"\u003e\n\u003ctd style=\"height: 24px; box-sizing: border-box; outline: 0px;\" class=\"xl63\" height=\"24\"\u003e\u003cspan style=\"box-sizing: border-box; outline: 0px;\"\u003eOutput\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"box-sizing: border-box; outline: 0px; height: 24px;\" class=\"xl63\"\u003e\u003cspan style=\"box-sizing: border-box; outline: 0px;\"\u003e4~20mA RL\u0026gt;600\u003cspan class=\"font6\"\u003eΩ\u003c\/span\u003e\u003cspan class=\"font5\"\u003e(standard),1~5V\\1~10V\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 24px; box-sizing: border-box; outline: 0px;\" height=\"24\"\u003e\n\u003ctd style=\"height: 24px; box-sizing: border-box; outline: 0px;\" class=\"xl63\" height=\"24\"\u003e\u003cspan style=\"box-sizing: border-box; outline: 0px;\"\u003eCommunication\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"box-sizing: border-box; outline: 0px; height: 24px;\" class=\"xl63\"\u003e\u003cspan style=\"box-sizing: border-box; outline: 0px;\"\u003eRS485\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 24px; box-sizing: border-box; outline: 0px;\" height=\"24\"\u003e\n\u003ctd style=\"height: 24px; box-sizing: border-box; outline: 0px;\" class=\"xl63\" height=\"24\"\u003e\u003cspan style=\"box-sizing: border-box; outline: 0px;\"\u003eRelay\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"box-sizing: border-box; outline: 0px; height: 24px;\" class=\"xl63\"\u003e\u003cspan style=\"box-sizing: border-box; outline: 0px;\"\u003e2 NPN relays (AC: 5A 250V DC: 10A 24V)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 24px; box-sizing: border-box; outline: 0px;\" height=\"24\"\u003e\n\u003ctd style=\"height: 24px; box-sizing: border-box; outline: 0px;\" class=\"xl63\" height=\"24\"\u003e\u003cspan style=\"box-sizing: border-box; outline: 0px;\"\u003eMaterial\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"box-sizing: border-box; outline: 0px; height: 24px;\" class=\"xl63\"\u003e\u003cspan style=\"box-sizing: border-box; outline: 0px;\"\u003eABS\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 24px; box-sizing: border-box; outline: 0px;\" height=\"24\"\u003e\n\u003ctd style=\"height: 24px; box-sizing: border-box; outline: 0px;\" class=\"xl63\" height=\"24\"\u003e\u003cspan style=\"box-sizing: border-box; outline: 0px;\"\u003eDimension\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"box-sizing: border-box; outline: 0px; height: 24px;\" class=\"xl64\"\u003e\u003cspan style=\"box-sizing: border-box; outline: 0px;\"\u003eΦ\u003cspan class=\"font5\"\u003e92mm \u003c\/span\u003e\u003cspan class=\"font6\"\u003e× \u003c\/span\u003e\u003cspan class=\"font5\"\u003e198mm \u003c\/span\u003e\u003cspan class=\"font6\"\u003e× \u003c\/span\u003e\u003cspan class=\"font5\"\u003eM60\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 24px; box-sizing: border-box; outline: 0px;\" height=\"24\"\u003e\n\u003ctd style=\"height: 24px; box-sizing: border-box; outline: 0px;\" class=\"xl63\" height=\"24\"\u003e\u003cspan style=\"box-sizing: border-box; outline: 0px;\"\u003eProtection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"box-sizing: border-box; outline: 0px; height: 24px;\" class=\"xl63\"\u003e\u003cspan style=\"box-sizing: border-box; outline: 0px;\"\u003eIP65 (others optional)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 24px; box-sizing: border-box; outline: 0px;\" height=\"24\"\u003e\n\u003ctd style=\"height: 24px; box-sizing: border-box; outline: 0px;\" class=\"xl63\" height=\"24\"\u003e\u003cspan style=\"box-sizing: border-box; outline: 0px;\"\u003eConnection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"box-sizing: border-box; outline: 0px; height: 24px;\" class=\"xl63\"\u003e\u003cspan style=\"box-sizing: border-box; outline: 0px;\"\u003eElectrical interface: M20X1.5, Installation: M60X2 or ￠61MM\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Sper Scientific","offers":[{"title":"Default Title","offer_id":46246435094752,"sku":"870010","price":568.1,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/integrated-ultrasonic-level-meter-870010-7414059.jpg?v=1760646507"},{"product_id":"inline-industrial-conductivity-electrode","title":"Online Industrial Conductivity Electrode","description":"\u003ch1\u003eThe Industrial Conductivity Series electrodes are purpose-built for precise conductivity measurements in pure water, ultra-pure water and water treatment applications.\u003c\/h1\u003e\n\u003cp\u003eThese electrodes are especially suitable for use in thermal power plants and the water treatment industry, where durability and accuracy are critical. Featuring a robust double-cylinder structure made from titanium alloy, they naturally oxidize to form a chemically passive layer, enhancing resistance to various liquids (excluding hydrofluoric acid). Temperature compensation components are available in multiple options, including NTC2.252K, 2K, 10K, 20K, 30K, PT100, and PT1000, which can be specified based on user needs.\u003c\/p\u003e\n\u003cp\u003eThe K=10.0 or K=30 electrodes in this series incorporate a large-area platinum structure, providing excellent resistance to strong acids and alkalis as well as high anti-fouling capacity. These electrodes are well-suited for on-line conductivity measurement in demanding industries such as wastewater treatment and seawater purification.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDouble-cylinder structure with corrosion-resistant titanium alloy\u003c\/li\u003e\n\u003cli\u003eNaturally oxidized, chemically passive surface for improved durability\u003c\/li\u003e\n\u003cli\u003eMultiple temperature compensation options: NTC2.252K, 2K, 10K, 20K, 30K, PT100, PT1000\u003c\/li\u003e\n\u003cli\u003eLarge-area platinum structure on K=10.0 and K=30 models for resistance to strong acids and alkalis\u003c\/li\u003e\n\u003cli\u003eExcellent anti-fouling capacity, ideal for specialized industrial applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003eOrdering Notes: \u003cbr\u003e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003e1. All Sper Inline \u003ca href=\"https:\/\/sperdirect.com\/collections\/inline-water-quality-monitors-sensors\" title=\"Inline Water Quality Monitoring\"\u003eWater Quality Meters and Sensors\u003c\/a\u003e are sold separately - one of each is required for a complete system. \u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003e\u003cspan\u003e\u003cspan style=\"color: #ff2a00;\"\u003e2. All Inline Water Quality Meters and Sensors ship direct from the factory. Please allow 10-15 business days for shipping and \u003cspan style=\"caret-color: rgb(255, 42, 0);\"\u003ehandling\u003c\/span\u003e. \u003c\/span\u003e\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003ctable style=\"height: 245px;\" class=\"MsoNormalTable\" border=\"0\" cellspacing=\"0\" cellpadding=\"0\" width=\"715\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 35px;\"\u003e\n\u003ctd style=\"height: 35px;\" width=\"155\" nowrap\u003e\n\u003cp style=\"text-align: left;\" class=\"MsoNormal\" align=\"center\"\u003e\u003cb\u003e\u003cspan\u003eProbe\u003c\/span\u003e\u003c\/b\u003e\u003cb\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"112\" nowrap\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cb\u003e\u003cspan\u003e870003-ICE-01\u003c\/span\u003e\u003c\/b\u003e\u003cb\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"112\" nowrap\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cb\u003e\u003cspan\u003e870003-ICE-02\u003c\/span\u003e\u003c\/b\u003e\u003cb\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"112\" nowrap\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cb\u003e\u003cspan\u003e870003-ICE-03\u003c\/span\u003e\u003c\/b\u003e\u003cb\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"112\" nowrap\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cb\u003e\u003cspan\u003e870003-ICE-04\u003c\/span\u003e\u003c\/b\u003e\u003cb\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"112\" nowrap\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cb\u003e\u003cspan\u003e870003-ICE-05\u003c\/span\u003e\u003c\/b\u003e\u003cb\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35px;\"\u003e\n\u003ctd style=\"height: 35px;\" width=\"155\" nowrap\u003e\n\u003cp style=\"text-align: left;\" class=\"MsoNormal\" align=\"center\"\u003e\u003cb\u003e\u003cspan\u003eCC\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"112\" nowrap\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e0.01\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"112\" nowrap\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e0.1\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"112\" nowrap\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e1.0\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"112\" nowrap\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e10\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"112\" nowrap\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e30\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35px;\"\u003e\n\u003ctd style=\"height: 35px;\" width=\"155\" nowrap\u003e\n\u003cp style=\"text-align: left;\" class=\"MsoNormal\" align=\"center\"\u003e\u003cb\u003e\u003cspan\u003eEC Range\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"112\" nowrap\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e0-2μS\/cm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"112\" nowrap\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e0-200μS\/cm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"112\" nowrap\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e0-2000μS\/cm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"112\" nowrap\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e0-20000μS\/cm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"112\" nowrap\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e30-600mS\/cm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35px;\"\u003e\n\u003ctd style=\"height: 35px;\" width=\"155\" nowrap\u003e\n\u003cp style=\"text-align: left;\" class=\"MsoNormal\" align=\"center\"\u003e\u003cb\u003e\u003cspan\u003eTemp Range\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"112\" nowrap\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e0.0-100.0°C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"112\" nowrap\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e0.0-100.0°C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"112\" nowrap\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e0.0-100.0°C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"112\" nowrap\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e0.0-100.0°C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"112\" nowrap\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e0.0-100.0°C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35px;\"\u003e\n\u003ctd style=\"height: 35px;\" width=\"155\" nowrap\u003e\n\u003cp style=\"text-align: left;\" class=\"MsoNormal\" align=\"center\"\u003e\u003cb\u003e\u003cspan\u003eAccuracy\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"560\" nowrap colspan=\"5\"\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e2%, ±0.5°C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35px;\"\u003e\n\u003ctd style=\"height: 35px;\" width=\"155\" nowrap\u003e\n\u003cp style=\"text-align: left;\" class=\"MsoNormal\" align=\"center\"\u003e\u003cb\u003e\u003cspan\u003eWithstand pressure\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"560\" nowrap colspan=\"5\"\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e0.4MPa\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35px;\"\u003e\n\u003ctd style=\"height: 35px;\" width=\"155\" nowrap\u003e\n\u003cp style=\"text-align: left;\" class=\"MsoNormal\" align=\"center\"\u003e\u003cb\u003e\u003cspan\u003eWaterproof Level\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"560\" nowrap colspan=\"5\"\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003eIP68\/NEMA6P\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable border=\"0\" style=\"width: 100%; height: 430px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 38px;\"\u003e\n\u003ctd style=\"width: 21.721869%; height: 38px;\"\u003e\u003cspan\u003eConstant of electrode\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 28.232759%; height: 38px;\"\u003e\u003cspan\u003e0.1\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd rowspan=\"6\" style=\"width: 46.058303%; height: 430px;\"\u003e\u003cspan\u003e\u003cimg src=\"https:\/\/www.boquinstruments.com\/uploads\/DDG-0.1-Industrial-Conductivity-Sensor.jpg\" alt=\"DDG-0.1 Industrial Conductivity Sensor\" class=\"alignnone size-full wp-image-2585\"\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 38px;\"\u003e\n\u003ctd style=\"width: 21.721869%; height: 38px;\"\u003e\u003cspan\u003eCompressive strength\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 28.232759%; height: 38px;\"\u003e\u003cspan\u003e0.6 MPa\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 21.721869%; height: 19px;\"\u003e\u003cspan\u003eMeasuring range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 28.232759%; height: 19px;\"\u003e\u003cspan\u003e0-2000 uS\/em\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 38px;\"\u003e\n\u003ctd style=\"width: 21.721869%; height: 38px;\"\u003e\u003cspan\u003eConnection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 28.232759%; height: 38px;\"\u003e\u003cspan\u003e1\/2 or 3\/4 Thread Installation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 38px;\"\u003e\n\u003ctd style=\"width: 21.721869%; height: 38px;\"\u003e\u003cspan\u003eMaterial\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 28.232759%; height: 38px;\"\u003e\n\u003cspan\u003e316L Titanium Alloy \u003cbr\u003eand \u003c\/span\u003ePlatinum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 259px;\"\u003e\n\u003ctd style=\"width: 21.721869%; height: 259px;\"\u003e\u003cspan\u003eApplication\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 28.232759%; height: 259px;\"\u003e\u003cspan\u003eWater Treatment Industry\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4\u003eDownloads\u003c\/h4\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cstrong\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/860031-33-i.pdf?v=1598908093\" target=\"_blank\"\u003e \u003c\/a\u003e\u003ca rel=\"noopener\" title=\"Inline Industrial Conductivity Sensor - Users Manual\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/Inductive_Conductivity_Sensor_-_Users_Manual.pdf\" target=\"_blank\"\u003e\u003cimg style=\"float: left;\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/pdf-icon-63x63_480x480.png?v=1598991821\" alt=\"PDF\"\u003e \u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/860031-33-i.pdf?v=1598908093\" target=\"_blank\"\u003e\u003cbr\u003e\u003c\/a\u003e\u003ca rel=\"noopener\" title=\"Inline Industrial Conductivity Sensor - Users Manual\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/Inductive_Conductivity_Sensor_-_Users_Manual.pdf\" target=\"_blank\"\u003eInstruction Manual\u003c\/a\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e","brand":"Sper Scientific","offers":[{"title":"870003-ICE-01","offer_id":52569194791136,"sku":"870003-ICE-01","price":170.89,"currency_code":"USD","in_stock":true},{"title":"870003-ICE-02","offer_id":52569194823904,"sku":"870003-ICE-02","price":170.89,"currency_code":"USD","in_stock":true},{"title":"870003-ICE-03","offer_id":52569194856672,"sku":"870003-ICE-03","price":170.89,"currency_code":"USD","in_stock":true},{"title":"870003-ICE-04","offer_id":52569194889440,"sku":"870003-ICE-04","price":170.89,"currency_code":"USD","in_stock":true},{"title":"870003-ICE-05","offer_id":52569194922208,"sku":"870003-ICE-05","price":170.89,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/inline-industrial-conductivity-electrode-870003-ice-994131.jpg?v=1752691912"},{"product_id":"industrial-conductivity-tds-salinity-resistivity-meter","title":"Online Industrial Conductivity, TDS, Salinity, Resistivity Meter","description":"\u003cp\u003e\u003cb\u003eOrdering Notes:\u003cbr\u003e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003e1. ALL SPER ONLINE WATER QUALITY METERS AND SENSORS ARE SOLD SEPARATELY - Please be sure to add the appropriate sensor (listed above) when purchasing your meter - ONE METER AND SENSOR are required for a complete system. \u003c\/span\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003e\u003cspan\u003e\u003cspan style=\"color: #ff2a00;\"\u003e2. All Inline Water Quality Meters and Sensors ship direct from the factory. Please allow 10-15 business days for shipping and \u003cspan style=\"caret-color: rgb(255, 42, 0);\"\u003ehandling\u003c\/span\u003e. \u003c\/span\u003e\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eOur Industrial Conductivity, TDS, Salinity and Resistance Meter is essential for inline monitoring of water conductivity in applications like drinking water treatment, industrial water and boiler water.\u003c\/h1\u003e\n\u003cp\u003eConductivity measurements provide valuable insight into the amount of dissolved material in water. We offer a wide range of high-quality, affordable conductivity sensors, suitable for everything from deionized water to highly saturated brines. \u003c\/p\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cspan\u003eWhy is conductivity measurement important in water treatment? The conductivity of water is crucial because it gives an indication of the amount of dissolved material within that water. \u003cmeta charset=\"utf-8\"\u003ePaired with Sper Scientific conductivity controllers, this meter delivers reliable, cost-effective process control across industries.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMulti-functional: Measures conductivity, TDS, resistivity, salinity, and temperature\u003c\/li\u003e\n\u003cli\u003eReliable conductivity monitoring for consistent results\u003c\/li\u003e\n\u003cli\u003eEasy system integration for seamless conductivity measurement\u003c\/li\u003e\n\u003cli\u003eIdeal for all water quality environments\u003c\/li\u003e\n\u003cli\u003eCompatible with contact conductivity sensors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable class=\"table table-bordered table-hover\" data-sort=\"sortDisabled\" style=\"width: 70.766488%;\" height=\"750\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd width=\"220\" style=\"width: 40.929401%;\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd rowspan=\"1\" colspan=\"2\" width=\"97\" style=\"width: 57.829181%;\"\u003e\n\u003cp\u003e\u003cstrong\u003eInline Conductivity Meter\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"220\" style=\"width: 40.929401%;\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eMeasurement\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd rowspan=\"1\" colspan=\"2\" width=\"97\" style=\"width: 57.829181%;\"\u003e\u003cspan\u003eConductivity, TDS, Resistivity, Salinity, Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"220\" style=\"width: 40.929401%;\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd rowspan=\"1\" colspan=\"2\" width=\"97\" style=\"width: 57.829181%;\"\u003e\n\u003cp\u003e0.00uS\/cm~2000000.00 uS\/cm(0.00uS\/cm~2000.00 mS\/cm)\u003c\/p\u003e\n\u003cp\u003e0.00g\/L~80.00 g\/L (ppt)\u003c\/p\u003e\n\u003cp\u003e0.00mg\/L~130000.00 mg\/L (ppm)\u003c\/p\u003e\n\u003cp\u003e0.00MΩ~20.00MΩ\u003c\/p\u003e\n\u003cp\u003e-40.0℃~200.0℃ (refer to matching electrode)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"1\" colspan=\"1\" width=\"220\" style=\"width: 40.929401%;\"\u003e\u003cspan\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd rowspan=\"1\" colspan=\"2\" width=\"97\" style=\"width: 57.829181%;\"\u003e\u003cspan\u003e1%,  ±0.2℃\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"220\" style=\"width: 40.929401%;\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eHousing Material\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\" width=\"97\" style=\"width: 57.829181%;\"\u003e\n\u003cp\u003e\u003cspan\u003eABS Flame retardant : V0\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"220\" style=\"width: 40.929401%;\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003ePower\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\" width=\"97\" style=\"width: 57.829181%;\"\u003e\n\u003cp\u003e\u003cspan\u003e90 – 260V AC 50\/60Hz\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"220\" style=\"width: 40.929401%;\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eConsumption\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\" width=\"97\" style=\"width: 57.829181%;\"\u003e\n\u003cp\u003e\u003cspan\u003e4W\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"220\" style=\"width: 40.929401%;\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOutput\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\" width=\"97\" style=\"width: 57.829181%;\"\u003e\n\u003cp\u003e\u003cspan\u003eTwo ways 4-20mA output\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\" width=\"220\" style=\"width: 40.929401%;\"\u003e\u003cspan\u003e\u003cstrong\u003eCommunication\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" rowspan=\"1\" width=\"97\" style=\"width: 57.829181%;\"\u003e\u003cspan\u003eRS485 Modbus\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"220\" style=\"width: 40.929401%;\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eRelay\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\" width=\"97\" style=\"width: 57.829181%;\"\u003e\n\u003cp\u003e\u003cspan\u003eTwo relays: 5A\/250V AC, 5A\/30V DC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"220\" style=\"width: 40.929401%;\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eTemperature.Comp\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\" width=\"97\" style=\"width: 57.829181%;\"\u003e\n\u003cp\u003e\u003cspan\u003ePT1000 \/ NTC10K\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\" width=\"79\" style=\"width: 40.929401%;\"\u003e\u003cstrong\u003eDimension\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" rowspan=\"1\" width=\"97\" style=\"width: 57.829181%;\"\u003e\u003cspan\u003e144×144×104mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\" width=\"79\" style=\"width: 40.929401%;\"\u003e\u003cstrong\u003eHole size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" rowspan=\"1\" width=\"97\" style=\"width: 57.829181%;\"\u003e138*138mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"220\" style=\"width: 40.929401%;\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProtection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\" width=\"97\" style=\"width: 57.829181%; text-align: left;\"\u003e\u003cspan\u003eIP65\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"220\" style=\"width: 40.929401%;\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eData Logger\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\" rowspan=\"1\" width=\"97\" style=\"width: 57.829181%;\"\u003e\u003cspan\u003e1,000 times\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"220\" style=\"width: 40.929401%;\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eLanguage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\" width=\"97\" style=\"width: 57.829181%;\"\u003e\n\u003cp\u003e\u003cspan\u003eEnglish \/ 简体中文\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"220\" style=\"width: 40.929401%;\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eInstallation\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\" width=\"97\" style=\"width: 57.829181%;\"\u003e\n\u003cp\u003e\u003cspan\u003ePanel \/ Wall \/ Pipe mounted\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable style=\"height: 245px;\" class=\"MsoNormalTable\" border=\"0\" cellspacing=\"0\" cellpadding=\"0\" width=\"715\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 35px;\"\u003e\n\u003ctd style=\"height: 35px;\" width=\"155\" nowrap\u003e\n\u003cp style=\"text-align: left;\" class=\"MsoNormal\" align=\"center\"\u003e\u003cb\u003e\u003cspan\u003eProbe\u003c\/span\u003e\u003c\/b\u003e\u003cb\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"112\" nowrap\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cb\u003e\u003cspan\u003e870003-ICE-01\u003c\/span\u003e\u003c\/b\u003e\u003cb\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"112\" nowrap\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cb\u003e\u003cspan\u003e870003-ICE-02\u003c\/span\u003e\u003c\/b\u003e\u003cb\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"112\" nowrap\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cb\u003e\u003cspan\u003e870003-ICE-03\u003c\/span\u003e\u003c\/b\u003e\u003cb\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"112\" nowrap\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cb\u003e\u003cspan\u003e870003-ICE-04\u003c\/span\u003e\u003c\/b\u003e\u003cb\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"112\" nowrap\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cb\u003e\u003cspan\u003e870003-ICE-05\u003c\/span\u003e\u003c\/b\u003e\u003cb\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35px;\"\u003e\n\u003ctd style=\"height: 35px;\" width=\"155\" nowrap\u003e\n\u003cp style=\"text-align: left;\" class=\"MsoNormal\" align=\"center\"\u003e\u003cb\u003e\u003cspan\u003eCC\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"112\" nowrap\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e0.01\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"112\" nowrap\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e0.1\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"112\" nowrap\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e1.0\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"112\" nowrap\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e10\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"112\" nowrap\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e30\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35px;\"\u003e\n\u003ctd style=\"height: 35px;\" width=\"155\" nowrap\u003e\n\u003cp style=\"text-align: left;\" class=\"MsoNormal\" align=\"center\"\u003e\u003cb\u003e\u003cspan\u003eEC Range\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"112\" nowrap\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e0-2μS\/cm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"112\" nowrap\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e0-200μS\/cm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"112\" nowrap\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e0-2000μS\/cm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"112\" nowrap\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e0-20000μS\/cm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"112\" nowrap\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e30-600mS\/cm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35px;\"\u003e\n\u003ctd style=\"height: 35px;\" width=\"155\" nowrap\u003e\n\u003cp style=\"text-align: left;\" class=\"MsoNormal\" align=\"center\"\u003e\u003cb\u003e\u003cspan\u003eTemp Range\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"112\" nowrap\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e0.0-100.0°C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"112\" nowrap\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e0.0-100.0°C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"112\" nowrap\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e0.0-100.0°C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"112\" nowrap\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e0.0-100.0°C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"112\" nowrap\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e0.0-100.0°C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35px;\"\u003e\n\u003ctd style=\"height: 35px;\" width=\"155\" nowrap\u003e\n\u003cp style=\"text-align: left;\" class=\"MsoNormal\" align=\"center\"\u003e\u003cb\u003e\u003cspan\u003eAccuracy\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"560\" nowrap colspan=\"5\"\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e2%, ±0.5°C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35px;\"\u003e\n\u003ctd style=\"height: 35px;\" width=\"155\" nowrap\u003e\n\u003cp style=\"text-align: left;\" class=\"MsoNormal\" align=\"center\"\u003e\u003cb\u003e\u003cspan\u003eWithstand pressure\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"560\" nowrap colspan=\"5\"\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e0.4MPa\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35px;\"\u003e\n\u003ctd style=\"height: 35px;\" width=\"155\" nowrap\u003e\n\u003cp style=\"text-align: left;\" class=\"MsoNormal\" align=\"center\"\u003e\u003cb\u003e\u003cspan\u003eWaterproof Level\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35px;\" width=\"560\" nowrap colspan=\"5\"\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003eIP68\/NEMA6P\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eDownloads\u003c\/h4\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cstrong\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/860031-33-i.pdf\" target=\"_blank\"\u003e \u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/870003_Conductivity_Meter_Manual.pdf\" title=\"Inline Conductivity Meter - Users Manual\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg alt=\"PDF\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/pdf-icon-63x63_480x480.png\" style=\"float: left;\"\u003e\u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/860031-33-i.pdf\" target=\"_blank\"\u003e\u003cbr\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/870003_Conductivity_Meter_Manual.pdf\" title=\"Inline Conductivity Meter - Users Manual\"\u003eInstruction Manual\u003c\/a\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Sper Scientific","offers":[{"title":"Default Title","offer_id":46246435225824,"sku":"870003","price":722.98,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/industrial-conductivity-tds-salinity-resistivity-meter-870003-600932.jpg?v=1752691869"},{"product_id":"digital-optical-dissolved-oxygen-meter","title":"Online Digital Optical Dissolved Oxygen Meter","description":"\u003cp\u003e\u003cb\u003eOrdering Notes:\u003cbr\u003e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003e1. ALL SPER ONLINE WATER QUALITY METERS AND SENSORS ARE SOLD SEPARATELY - Please be sure to add the appropriate sensor (listed above) when purchasing your meter - ONE METER AND SENSOR are required for a complete system. \u003c\/span\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003e\u003cspan\u003e\u003cspan style=\"color: #ff2a00;\"\u003e2. All Inline Water Quality Meters and Sensors ship direct from the factory. Please allow 10-15 business days for shipping and \u003cspan style=\"caret-color: rgb(255, 42, 0);\"\u003ehandling\u003c\/span\u003e. \u003c\/span\u003e\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1 class=\"p1\"\u003e\u003cspan class=\"s1\"\u003eSper Scientific Inline Digital Optical Dissolved Oxygen Meter features an advanced sensor designed for precise, real-time measurement of dissolved oxygen and temperature in a variety of applications. \u003c\/span\u003e\u003c\/h1\u003e\n\u003cp class=\"p1\"\u003e\u003cspan class=\"s1\"\u003eEngineered for durability and minimal maintenance, this meter is ideal for harsh environments. This Digital Optical Dissolved Oxygen Meter is an essential tool for ensuring optimal water quality and effective monitoring across various industries, enhancing operational efficiency and compliance with environmental standards. \u003c\/span\u003e\u003cspan class=\"s1\"\u003eEngineered for durability and maintenance-free operation, it features innovative light source technology that ensures a long service life while reducing operational costs.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"p1\"\u003e\u003cspan class=\"s1\"\u003eThis meter offers dual 4-20mA output options for seamless integration into existing systems, providing real-time data for both dissolved oxygen and temperature. With a built-in data recording function, users can easily access historical data and trends for effective monitoring.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"p1\"\u003e\u003cspan class=\"s1\"\u003eDesigned for versatile installation, the meter can be panel-mounted, wall-mounted, or pipe-mounted. It incorporates RS485 Modbus RTU communication for straightforward digital integration. Additionally, the device includes three relay outputs: two for high and low limit alarms and one for clean time settings.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"p1\"\u003e\u003cspan class=\"s1\"\u003eIdeal for applications in industrial wastewater, drinking water, pulp and paper processing and the chemical industry, this optical dissolved oxygen meter ensures optimal water quality and compliance across various treatment processes.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"p2\"\u003e\u003cspan class=\"s1\"\u003eDissolved oxygen (DO) is the oxygen present in water, essential for the survival of fish, invertebrates, and microorganisms. Measured in milligrams per liter (mg\/L), DO levels are influenced by factors like temperature, pressure, salinity, and organic matter. Adequate dissolved oxygen is crucial for healthy aquatic ecosystems; low levels can cause hypoxia, harming aquatic life. Regular monitoring of DO is important for maintaining water quality in natural bodies of water and wastewater treatment.\u003c\/span\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ul1\"\u003e\n\u003cli class=\"li1\"\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eHigh Precision Measurement\u003c\/b\u003e: Utilizes cutting-edge optical technology for accurate and reliable dissolved oxygen readings.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"li1\"\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eRobust Design\u003c\/b\u003e: Suitable for challenging applications, the sensor boasts a long operational lifespan thanks to innovative light source technology.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"li1\"\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eFlexible Output Options\u003c\/b\u003e: Provides dual 4-20mA outputs for both dissolved oxygen and temperature measurements, ensuring compatibility with various systems.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"li1\"\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eData Recording Capability\u003c\/b\u003e: Equipped with a built-in data logger, allowing users to easily access historical data and view trends via history curves.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"li1\"\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eMounting Versatility\u003c\/b\u003e: Can be panel-mounted, wall-mounted, or pipe-mounted, providing flexibility for installation in different environments.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"li1\"\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eRS485 Modbus Communication\u003c\/b\u003e: Direct integration with digital systems through RS485 Modbus RTU, facilitating easy data transmission and system integration.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"li1\"\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eRelay Outputs\u003c\/b\u003e: Features three relay outputs—two configurable for high and low limit alarms and one for clean time settings.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"p4\"\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eApplications\u003c\/b\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli class=\"p4\"\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eIndustrial Wastewater Treatment\u003c\/b\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"p4\"\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eDrinking Water Quality Monitoring\u003c\/b\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003ePulp and Paper Processing\u003c\/b\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eChemical Industry Applications\u003c\/b\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eGeneral Water and Wastewater Treatment\u003c\/b\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\n\u003cspan class=\"s1\"\u003e\u003cb\u003eSpecifications\u003cbr\u003e\u003c\/b\u003e\u003c\/span\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003ctable data-sort=\"sortDisabled\" class=\"table table-bordered table-hover\" height=\"1086\" style=\"width: 73.3878%;\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd rowspan=\"1\" colspan=\"1\" style=\"width: 33.9378%;\"\u003e\u003cstrong\u003eProduct\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd rowspan=\"1\" colspan=\"2\" style=\"width: 64.5408%;\"\u003e\n\u003cstrong\u003eInline Digital Dissolved Oxygen Meter\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.9378%;\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eFunction\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\" rowspan=\"1\" style=\"width: 64.5408%;\"\u003e\n\u003cp\u003e\u003cspan\u003eOnline measure dissolved oxygen and temperature\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.9378%;\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eSensor Type\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\" rowspan=\"1\" style=\"width: 64.5408%;\"\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eWith Digital Dissolved Oxyen Sensor\u003c\/p\u003e\n\u003cp\u003e( Sensor with RS485 Modbus )\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.9378%;\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eMeasure Range\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\" rowspan=\"1\" style=\"width: 64.5408%;\"\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e0~20.00 mg\/L\u003c\/p\u003e\n\u003cp\u003e0~200.00 %\u003c\/p\u003e\n\u003cp\u003e-10.0~100.0℃\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.9378%;\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eAccuracy\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\" rowspan=\"1\" style=\"width: 64.5408%;\"\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e±1%FS\u003c\/p\u003e\n\u003cp\u003e±0.5℃\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.9378%;\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003ePower Supply\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 64.5408%;\"\u003e\n\u003cp\u003e\u003cspan\u003e90 – 260V AC 50\/60Hz\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.9378%;\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eHousing Material\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 64.5408%;\"\u003e\n\u003cp\u003e\u003cspan\u003eABS\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.9378%;\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eCommunication\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 64.5408%;\"\u003e\n\u003cp\u003e\u003cspan\u003eRS485 Modbus\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.9378%;\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eData Recording Function\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 64.5408%;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.9378%;\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eProtection\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 64.5408%;\"\u003e\n\u003cp\u003e\u003cspan\u003eIP65\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.9378%;\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eCurrent output\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 64.5408%;\"\u003e\n\u003cp\u003eIsolated type \u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e2 ways of 4-20mA output \u003c\/p\u003e\n\u003cp\u003e(dissolved oxygen.temperature)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.9378%;\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eRelay\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 64.5408%;\"\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eTwo relays for high and low limit\u003c\/p\u003e\n\u003cp\u003eOne relay for clean\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.9378%;\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eOverall Dimensions\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 64.5408%;\"\u003e\n\u003cp\u003e\u003cspan\u003e144×144×104mm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"1\" colspan=\"1\" style=\"width: 33.9378%;\"\u003e\u003cstrong\u003eHole size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd rowspan=\"1\" colspan=\"2\" style=\"width: 64.5408%;\"\u003e138×138mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.9378%;\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eInstallation\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 64.5408%;\"\u003e\n\u003cp\u003e\u003cspan\u003ePanel, Wall or Pipe mounted\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4\u003eDownloads\u003c\/h4\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cstrong\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/860031-33-i.pdf?v=1598908093\" target=\"_blank\"\u003e \u003c\/a\u003e\u003ca rel=\"noopener\" title=\"Inline Digital DO Meter - Users Manual\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/870006_Digital_DO_Meter_Manual.pdf\" target=\"_blank\"\u003e\u003cimg style=\"float: left;\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/pdf-icon-63x63_480x480.png?v=1598991821\" alt=\"PDF\"\u003e \u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/860031-33-i.pdf?v=1598908093\" target=\"_blank\"\u003e\u003cbr\u003e\u003c\/a\u003e\u003ca rel=\"noopener\" title=\"Inline Digital DO Meter - Users Manual\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/870006_Digital_DO_Meter_Manual.pdf\" target=\"_blank\"\u003eInstruction Manual\u003c\/a\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Sper Scientific","offers":[{"title":"Default Title","offer_id":46246435520736,"sku":"870006","price":948.2,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/inline-digital-optical-dissolved-oxygen-meter-870006-312466.jpg?v=1752691908"},{"product_id":"industrial-ph-orp-meter","title":"Online Industrial PH \u0026 ORP Meter","description":"\u003cp\u003e\u003cb\u003eOrdering Notes:\u003cbr\u003e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003e1. ALL SPER ONLINE WATER QUALITY METERS AND SENSORS ARE SOLD SEPARATELY - Please be sure to add the appropriate sensor (listed above) when purchasing your meter - ONE METER AND SENSOR are required for a complete system. \u003c\/span\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003e\u003cspan\u003e\u003cspan style=\"color: #ff2a00;\"\u003e2. All Inline Water Quality Meters and Sensors ship direct from the factory. Please allow 10-15 business days for shipping and \u003cspan style=\"caret-color: rgb(255, 42, 0);\"\u003ehandling\u003c\/span\u003e. \u003c\/span\u003e\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eOur Inline Industrial PH \u0026amp; ORP Meter offers stable and reliable operation designed to solve common issues faced by operators in water treatment and processing plants. \u003c\/h1\u003e\n\u003cp\u003eThese analyzers provide precise, continuous measurement, ensuring dependable water quality monitoring. Each pH and ORP meter is equipped with a transmitter and process adaptation, tailored to meet your specific pH control requirements. The meter delivers accurate readings in diverse environments, from ultra-pure water to bioreactor applications - even in challenging conditions like chemical production.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eStable, precise, continuous measurement of pH, ORP and temperature\u003c\/li\u003e\n\u003cli\u003eFlexible installation options: panel, wall, or pipe-mounted\u003c\/li\u003e\n\u003cli\u003eDual 4-20mA outputs and standard RS485 Modbus RTU communication\u003c\/li\u003e\n\u003cli\u003eHigh\/low control relay functionality\u003c\/li\u003e\n\u003cli\u003eLocal data logging for up to 1,000 entries\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications include industrial wastewater, drinking water monitoring, environmental monitoring, ultra-pure water, fermentation, food production and more.\u003cb\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable data-sort=\"sortDisabled\" class=\"table table-bordered table-hover\" style=\"width: 100%; height: 550px;\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"firstRow\" style=\"height: 35px;\"\u003e\n\u003ctd width=\"141\" style=\"width: 25.589837%; height: 35px;\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"166\" colspan=\"2\" rowspan=\"1\" style=\"width: 72.232305%; height: 35px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eSper Scientific #870002 \u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35px;\"\u003e\n\u003ctd width=\"141\" style=\"width: 25.589837%; height: 35px;\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eMeasurement\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"176\" colspan=\"2\" rowspan=\"1\" style=\"width: 72.232305%; height: 35px;\"\u003e\u003cspan\u003epH \/ ORP \/ Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 54px;\"\u003e\n\u003ctd width=\"141\" style=\"width: 25.589837%; height: 54px;\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"176\" colspan=\"2\" rowspan=\"1\" style=\"width: 72.232305%; height: 54px;\"\u003e\n\u003cp\u003e\u003cspan\u003e-2 ~16 pH, -2000 ~2000 mV, -30 ~130 ℃\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd width=\"141\" colspan=\"1\" rowspan=\"1\" style=\"width: 25.589837%; height: 19px;\"\u003e\u003cspan\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd width=\"176\" colspan=\"2\" rowspan=\"1\" style=\"width: 72.232305%; height: 19px;\"\u003e\u003cspan\u003e0.05pH,  ±0.2℃\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35px;\"\u003e\n\u003ctd width=\"141\" style=\"width: 25.589837%; height: 35px;\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eHousing Material\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"176\" colspan=\"2\" style=\"width: 72.232305%; height: 35px;\"\u003e\n\u003cp\u003e\u003cspan\u003eABS Flame retardant : V0\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35px;\"\u003e\n\u003ctd width=\"141\" style=\"width: 25.589837%; height: 35px;\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003ePower\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"176\" colspan=\"2\" style=\"width: 72.232305%; height: 35px;\"\u003e\n\u003cp\u003e\u003cspan\u003e90 – 260V AC 50\/60Hz\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35px;\"\u003e\n\u003ctd width=\"141\" style=\"width: 25.589837%; height: 35px;\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eConsumption\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"176\" colspan=\"2\" style=\"width: 72.232305%; height: 35px;\"\u003e\n\u003cp\u003e\u003cspan\u003e4W\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35px;\"\u003e\n\u003ctd width=\"141\" style=\"width: 25.589837%; height: 35px;\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOutput\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"176\" colspan=\"2\" style=\"width: 72.232305%; height: 35px;\"\u003e\n\u003cp\u003e\u003cspan\u003eTwo ways 4-20mA output\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd width=\"141\" rowspan=\"1\" colspan=\"1\" style=\"width: 25.589837%; height: 19px;\"\u003e\u003cspan\u003e\u003cstrong\u003eCommunication\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd width=\"176\" rowspan=\"1\" colspan=\"2\" style=\"width: 72.232305%; height: 19px;\"\u003e\u003cspan\u003eRS485 Modbus\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35px;\"\u003e\n\u003ctd width=\"141\" style=\"width: 25.589837%; height: 35px;\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eRelay\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"176\" colspan=\"2\" style=\"width: 72.232305%; height: 35px;\"\u003e\n\u003cp\u003e\u003cspan\u003eThree relays, 5A\/250V AC      5A\/30V DC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35px;\"\u003e\n\u003ctd width=\"141\" style=\"width: 25.589837%; height: 35px;\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eTemperature Comp\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"176\" colspan=\"2\" style=\"width: 72.232305%; height: 35px;\"\u003e\n\u003cp\u003e\u003cspan\u003ePT1000 \/ NTC10K\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd rowspan=\"1\" colspan=\"1\" style=\"width: 25.589837%; height: 19px;\"\u003e\u003cstrong\u003eDimension\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd rowspan=\"1\" colspan=\"2\" style=\"width: 72.232305%; height: 19px;\"\u003e\u003cspan\u003e144×144×104mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd rowspan=\"1\" colspan=\"1\" style=\"width: 25.589837%; height: 19px;\"\u003e\u003cstrong\u003eHole Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd rowspan=\"1\" colspan=\"2\" style=\"width: 72.232305%; height: 19px;\"\u003e138*138mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35px;\"\u003e\n\u003ctd width=\"141\" style=\"width: 25.589837%; height: 35px;\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProtection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"176\" colspan=\"2\" style=\"width: 72.232305%; height: 35px;\"\u003e\u003cspan\u003eIP65\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35px;\"\u003e\n\u003ctd width=\"141\" style=\"width: 25.589837%; height: 35px;\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eData logger\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"166\" rowspan=\"1\" colspan=\"2\" style=\"width: 72.232305%; height: 35px;\"\u003e\u003cspan\u003e1,000 times\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35px;\"\u003e\n\u003ctd width=\"141\" style=\"width: 25.589837%; height: 35px;\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eLanguage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"176\" colspan=\"2\" style=\"width: 72.232305%; height: 35px;\"\u003e\n\u003cp\u003e\u003cspan\u003eEnglish \/ 简体中文\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35px;\"\u003e\n\u003ctd width=\"141\" style=\"width: 25.589837%; height: 35px;\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eInstallation\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"176\" colspan=\"2\" style=\"width: 72.232305%; height: 35px;\"\u003e\n\u003cp\u003e\u003cspan\u003ePanel \/ Wall \/ Pipe mounted\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4\u003eDownloads\u003c\/h4\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cstrong\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/860031-33-i.pdf?v=1598908093\" target=\"_blank\"\u003e \u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/870002Industrial_pH_and_ORP_Manual.pdf\" title=\"Inline pH ORP Mater - Users Manual\"\u003e\u003cimg alt=\"PDF\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/pdf-icon-63x63_480x480.png?v=1598991821\" style=\"float: left;\"\u003e\u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/860031-33-i.pdf?v=1598908093\" target=\"_blank\"\u003e\u003cbr\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/870002Industrial_pH_and_ORP_Manual.pdf\" title=\"Inline pH ORP Mater - Users Manual\"\u003eInstruction Manual\u003c\/a\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Sper Scientific","offers":[{"title":"Default Title","offer_id":46246436176096,"sku":"870002","price":661.55,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/inline-industrial-ph-orp-meter-870002-793550.jpg?v=1752691886"},{"product_id":"online-acid-alkaline-concentration-meter","title":"Online Acid Alkaline Concentration Meter","description":"\u003cp\u003e\u003cb\u003eOrdering Notes:\u003cbr\u003e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003e1. ALL SPER ONLINE WATER QUALITY METERS AND SENSORS ARE SOLD SEPARATELY - Please be sure to add the appropriate sensor (listed above) when purchasing your meter - ONE METER AND SENSOR are required for a complete system. \u003c\/span\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003e\u003cspan\u003e\u003cspan style=\"color: #ff2a00;\"\u003e2. All Inline Water Quality Meters and Sensors ship direct from the factory. Please allow 10-15 business days for shipping and \u003cspan style=\"caret-color: rgb(255, 42, 0);\"\u003ehandling\u003c\/span\u003e.\u003c\/span\u003e\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eThe Sper Scientific Inline Acid Alkali Concentration Meter is a smart, inline digital device designed for accurate measurement of acid and alkali concentrations.\u003c\/h1\u003e\n\u003cp\u003e\u003cstrong\u003eMeasuring Parameters:\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eConductivity, NaCl, HCl, NHO3, NaOH, H2SO4, KOH, Temperature\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis meter features a digital inductive conductivity sensor capable of measuring a variety of solutions, including \u003cstrong\u003ehydrochloric acid, nitric acid, sodium chloride, sodium hydroxide, potassium hydroxide and both dilute and concentrated sulfuric acid\u003c\/strong\u003e. It's advanced digital acid-base concentration sensor ensures precise and reliable monitoring across different applications.\u003c\/p\u003e\n\u003cp\u003eThis concentration meter is ideal for industries such as thermal power generation, chemical manufacturing and ion exchange processes where high-purity water production is critical. It is particularly useful for monitoring acid-base salt concentrations during processes like regenerating liquid concentration or controlling the solution concentration in boiler pipe pickling. Designed for continuous, real-time monitoring, it delivers dependable performance in demanding industrial environments.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSmart, inline digital meter for accurate acid and alkali concentration measurement\u003c\/li\u003e\n\u003cli\u003eEquipped with a digital inductive conductivity sensor\u003c\/li\u003e\n\u003cli\u003eMeasures various solutions, including HCl, nitric acid, NaCl, NaOH, KOH, and sulfuric acid (dilute and concentrated)\u003c\/li\u003e\n\u003cli\u003eIdeal for thermal power, chemical industry, and ion exchange processes for high-purity water production\u003c\/li\u003e\n\u003cli\u003eEnsures precise control of acid-base salt concentration in continuous monitoring applications\u003c\/li\u003e\n\u003cli\u003eSuitable for regenerating liquid concentration and boiler pipe pickling solution configuration\u003c\/li\u003e\n\u003cli\u003eProvides real-time, continuous monitoring for reliable industrial performance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"ce-col-w-1 ce-col-w-md-1 ce-col-w-xl-1 ce-list_item\"\u003e\n\u003cdiv class=\"ce-list_item-inner ce-d-flex\"\u003e\n\u003cdiv class=\"ce-list_text\"\u003e\n\u003cdiv class=\"ce-list_title\"\u003e\n\u003cdiv class=\"ce-title\"\u003e\u003cstrong\u003eReal-Time Monitoring\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"ce-list_summary\"\u003e\n\u003cdiv class=\"ce-summary\"\u003eReal-time analysis and adjustments for precise monitoring of acid-base concentrations in industrial processes.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"ce-col-w-1 ce-col-w-md-1 ce-col-w-xl-1 ce-list_item\"\u003e\n\u003cdiv class=\"ce-list_item-inner ce-d-flex\"\u003e\n\u003cdiv class=\"ce-list_image\"\u003e\n\u003cdiv class=\"ce-image_item\"\u003e\n\u003cdiv class=\"ce-image_inner base-image__item\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"ce-list_text\"\u003e\n\u003cdiv class=\"ce-list_title\"\u003e\n\u003cdiv class=\"ce-title\"\u003e\u003cstrong\u003eOptimal Performance\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"ce-list_summary\"\u003e\n\u003cdiv class=\"ce-summary\"\u003eWith its advanced technology, this analyzer ensures optimal performance and efficiency in various industrial applications by providing accurate and reliable data.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"ce-col-w-1 ce-col-w-md-1 ce-col-w-xl-1 ce-list_item\"\u003e\n\u003cdiv class=\"ce-list_item-inner ce-d-flex\"\u003e\n\u003cdiv class=\"ce-list_image\"\u003e\n\u003cdiv class=\"ce-image_item\"\u003e\n\u003cdiv class=\"ce-image_inner base-image__item\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"ce-list_text\"\u003e\n\u003cdiv class=\"ce-list_title\"\u003e\n\u003cdiv class=\"ce-title\"\u003e\u003cstrong\u003eUser-Friendly Interface\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"ce-list_summary\"\u003e\n\u003cdiv class=\"ce-summary\"\u003eThe user-friendly interface makes it easy to operate and allows for seamless monitoring and control of acid-base concentrations in industrial processes.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"ce-col-w-1 ce-col-w-md-1 ce-col-w-xl-1 ce-list_item\"\u003e\n\u003cdiv class=\"ce-list_item-inner ce-d-flex\"\u003e\n\u003cdiv class=\"ce-list_image\"\u003e\n\u003cdiv class=\"ce-image_item\"\u003e\n\u003cdiv class=\"ce-image_inner base-image__item\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"ce-list_text\"\u003e\n\u003cdiv class=\"ce-list_title\"\u003e\n\u003cdiv class=\"ce-title\"\u003e\u003cstrong\u003eDurable Construction\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"ce-list_summary\"\u003e\n\u003cdiv class=\"ce-summary\"\u003eQuality construction ensures long-lasting reliability and stability, providing a dependable solution for continuous monitoring in industrial environments.\u003c\/div\u003e\n\u003cdiv class=\"ce-summary\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ch4 class=\"ce-summary\"\u003eSpecifications\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eMeter Specifications\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ctable style=\"border-collapse: collapse; width: 523pt;\" width=\"697\" cellspacing=\"0\" cellpadding=\"0\" border=\"0\"\u003e\n\u003ccolgroup\u003e \u003ccol style=\"mso-width-source: userset; mso-width-alt: 7296; width: 171pt;\" width=\"228\"\u003e \u003ccol style=\"mso-width-source: userset; mso-width-alt: 15018; width: 352pt;\" width=\"469\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 34.0pt;\" height=\"45\"\u003e\n\u003ctd style=\"height: 34.0pt; width: 171pt;\" width=\"228\" class=\"xl67\" height=\"45\"\u003e\u003cstrong\u003eProduct\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 352pt;\" width=\"469\" class=\"xl68\"\u003e\u003cstrong\u003eSodium Chloride (NaCl) Concentration Meter\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 17.0pt;\" height=\"23\"\u003e\n\u003ctd style=\"height: 17.0pt;\" height=\"23\"\u003eOutput Current\u003c\/td\u003e\n\u003ctd style=\"width: 352pt;\" width=\"469\" class=\"xl65\"\u003eTwo ways of 4-20mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 17.0pt;\" height=\"23\"\u003e\n\u003ctd style=\"height: 17.0pt;\" height=\"23\"\u003eCurrent Output Accuracy\u003c\/td\u003e\n\u003ctd style=\"width: 352pt;\" width=\"469\" class=\"xl65\"\u003e±1%FS,±0.5℃\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 17.0pt;\" height=\"23\"\u003e\n\u003ctd style=\"height: 17.0pt;\" height=\"23\"\u003eTemp. Measure Range\u003c\/td\u003e\n\u003ctd style=\"width: 352pt;\" width=\"469\" class=\"xl65\"\u003eConductivity 0~2000ms\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 17.0pt;\" height=\"23\"\u003e\n\u003ctd style=\"height: 17.0pt;\" height=\"23\"\u003ePower Requirements\u003c\/td\u003e\n\u003ctd style=\"width: 352pt;\" width=\"469\" class=\"xl65\"\u003e90 – 260V AC 50; 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 17.0pt;\" height=\"23\"\u003e\n\u003ctd style=\"height: 17.0pt;\" height=\"23\"\u003eCommunication Interface\u003c\/td\u003e\n\u003ctd style=\"width: 352pt;\" width=\"469\" class=\"xl65\"\u003eRS485\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 17.0pt;\" height=\"23\"\u003e\n\u003ctd style=\"height: 17.0pt;\" height=\"23\"\u003eOutput Signal\u003c\/td\u003e\n\u003ctd style=\"width: 352pt;\" width=\"469\" class=\"xl65\"\u003eTwo ways of 4-20mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 17.0pt;\" height=\"23\"\u003e\n\u003ctd style=\"height: 17.0pt;\" height=\"23\"\u003eSize\/Weight\u003c\/td\u003e\n\u003ctd style=\"width: 352pt;\" width=\"469\" class=\"xl65\"\u003e144×144×104mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 17.0pt;\" height=\"23\"\u003e\n\u003ctd style=\"height: 17.0pt;\" height=\"23\"\u003ePrinciple\u003c\/td\u003e\n\u003ctd style=\"width: 352pt;\" width=\"469\" class=\"xl65\"\u003eInductive Conductivity Sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 17.0pt;\" height=\"23\"\u003e\n\u003ctd style=\"height: 17.0pt;\" height=\"23\"\u003eFree Chlorine Range\u003c\/td\u003e\n\u003ctd style=\"width: 352pt;\" width=\"469\" class=\"xl65\"\u003eConductivity 0~2000ms\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 17.0pt;\" height=\"23\"\u003e\n\u003ctd style=\"height: 17.0pt;\" height=\"23\"\u003eProtection\u003c\/td\u003e\n\u003ctd style=\"width: 352pt;\" width=\"469\" class=\"xl65\"\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 17.0pt;\" height=\"23\"\u003e\n\u003ctd style=\"height: 17.0pt;\" height=\"23\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd style=\"width: 352pt;\" width=\"469\" class=\"xl65\"\u003e±1%FS,±0.5℃\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 17.0pt;\" height=\"23\"\u003e\n\u003ctd style=\"height: 17.0pt;\" height=\"23\"\u003eRelays\u003c\/td\u003e\n\u003ctd style=\"width: 352pt;\" width=\"469\" class=\"xl65\"\u003eTwo relays: 5A 250V AC; 5A 30V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 17.0pt;\" height=\"23\"\u003e\n\u003ctd style=\"height: 17.0pt;\" height=\"23\"\u003eCommunication\u003c\/td\u003e\n\u003ctd style=\"width: 352pt;\" width=\"469\" class=\"xl65\"\u003eRS485\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 17.0pt;\" height=\"23\"\u003e\n\u003ctd style=\"height: 17.0pt;\" height=\"23\"\u003ePower\u003c\/td\u003e\n\u003ctd style=\"width: 352pt;\" width=\"469\" class=\"xl65\"\u003e90 – 260V AC 50;60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan class=\"s1\"\u003eSensor Specifications \u003cbr\u003e(\u003ca href=\"https:\/\/sperdirect.com\/collections\/inline-water-quality-monitors-sensors\/products\/online-acid-alkaline-concentration-meter\" rel=\"noopener\" target=\"_blank\"\u003eInline Acid-Alkaline Sensors\u003c\/a\u003e sold separately)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"s1\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable class=\"MsoNormalTable\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\" width=\"750\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"163\" nowrap valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"147\" nowrap valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/sperdirect.com\/products\/industrial-inductive-acid-alkaline-sensor?variant=47008857587936\"\u003e870009-CS-PFA\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"146\" nowrap valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/sperdirect.com\/collections\/inline-water-quality-monitors-sensors\/products\/online-acid-alkaline-concentration-meter\"\u003e870009-CS\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"150\" nowrap valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/sperdirect.com\/products\/industrial-inductive-acid-alkaline-sensor?variant=54581983805664\" title=\"870009 CS2-PFA Sensor\"\u003e870009-CS2-PFA\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"144\" nowrap valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/sperdirect.com\/products\/industrial-inductive-acid-alkaline-sensor?variant=47009050231008\"\u003e870009-CS2\u003c\/a\u003e\u003ca href=\"https:\/\/sperdirect.com\/products\/industrial-inductive-acid-alkaline-sensor?variant=47009050231008\"\u003e\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"163\" nowrap valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003eElectrode body material\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"147\" nowrap valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003ePFA (Perfluoroalkoxy)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"146\" nowrap valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003ePEEK (Polypropelyne)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"150\" nowrap valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003ePFA (Perfluoroalkoxy)\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"144\" nowrap valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003ePEEK (Polypropelyne)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"163\" nowrap valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003eOperating temperature\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"293\" nowrap colspan=\"2\" valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e-20~80\u003c\/span\u003e\u003cspan\u003e℃\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"150\" nowrap valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e-30~125\u003c\/span\u003e\u003cspan\u003e℃\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"144\" nowrap valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e-30~150\u003c\/span\u003e\u003cspan\u003e℃\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"163\" nowrap valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003eMeasurement range\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"587\" colspan=\"4\" valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003e1mS\/cm ~ 2000mS\/cm\u003cbr\u003eHNO3: 0.00%~29.00%\/35.00%~96.00%(25C)\u003cbr\u003eH2SO4: 0.00%~29.00%\/30.00%~83.00%\/93.00%~99.00%(10°C)\u003cbr\u003eHCL: 0.00%~18.00%\/22.00%~39.00%(25°C) \u003cbr\u003eNaOH: :0.00%~14.00%\/18.00%~50.00%(25°C)\u003cbr\u003eNaCl:0.00%~26.00%(20°C)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"163\" valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003eAccuracy\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"587\" nowrap colspan=\"4\" valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e±2% of reading or  ± 1 mS\/cm, whichever is greater;  ±0.5\u003c\/span\u003e\u003cspan\u003e℃\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"163\" nowrap valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003eMaximum pressure (bar)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"147\" nowrap valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e16bar\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"146\" nowrap valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e21bar\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"150\" nowrap valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e16bar\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"144\" nowrap valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003e21bar\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"163\" nowrap\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003eOutput\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"587\" nowrap colspan=\"4\"\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003eModbus RTU\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003eDownloads\u003c\/h4\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cstrong\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/860031-33-i.pdf?v=1598908093\" target=\"_blank\"\u003e \u003c\/a\u003e\u003ca rel=\"noopener\" title=\"Inline Acid Alkali Meter - Users Manual\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/870009_Acid_Alkali_analyzer_manual.pdf\" target=\"_blank\"\u003e\u003cimg style=\"float: left;\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/pdf-icon-63x63_480x480.png?v=1598991821\" alt=\"PDF\"\u003e \u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/860031-33-i.pdf?v=1598908093\" target=\"_blank\"\u003e\u003cbr\u003e\u003c\/a\u003e\u003ca rel=\"noopener\" title=\"Inline Acid Alkali Meter - Users Manual\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/870009_Acid_Alkali_analyzer_manual.pdf\" target=\"_blank\"\u003eInstruction Manual\u003c\/a\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"Sper Scientific","offers":[{"title":"Default Title","offer_id":46246436241632,"sku":"870009","price":1030.1,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/inline-acid-alkaline-concentration-meter-870009-354516.jpg?v=1752691908"},{"product_id":"online-total-suspended-solids-meter","title":"Online Total Suspended Solids Meter","description":"\u003cdiv class=\"flex max-w-full flex-col flex-grow\"\u003e\n\u003cdiv data-message-author-role=\"assistant\" data-message-id=\"e9712092-827b-4909-b36a-e40dccfa5e6f\" dir=\"auto\" class=\"min-h-8 text-message flex w-full flex-col items-end gap-2 whitespace-normal break-words [.text-message+\u0026amp;]:mt-5\" data-message-model-slug=\"gpt-4o\"\u003e\n\u003cdiv class=\"flex w-full flex-col gap-1 empty:hidden first:pt-[3px]\"\u003e\n\u003cdiv class=\"markdown prose w-full break-words dark:prose-invert light\"\u003e\n\u003cp\u003e\u003cb\u003eOrdering Notes:\u003cbr\u003e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003e1. ALL SPER ONLINE WATER QUALITY METERS AND SENSORS ARE SOLD SEPARATELY - Please be sure to add the appropriate sensor (listed above) when purchasing your meter - ONE METER AND SENSOR are required for a complete system. \u003c\/span\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003e\u003cspan\u003e\u003cspan style=\"color: #ff2a00;\"\u003e2. All Inline Water Quality Meters and Sensors ship direct from the factory. Please allow 10-15 business days for shipping and \u003cspan style=\"caret-color: rgb(255, 42, 0);\"\u003ehandling\u003c\/span\u003e.\u003c\/span\u003e\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eThe Digital Online TSS Meter is a high-precision instrument designed to measure Total Suspended Solids (TSS) in a variety of applications.\u003c\/h1\u003e\n\u003cp\u003eEquipped with an RS485 Online TSS Sensor, this meter provides accurate and reliable data, making it ideal for industrial and environmental monitoring.\u003c\/p\u003e\n\u003cp\u003eThe device features multiple output options including 4-20mA, RS485 Modbus RTU, and three relay outputs. Two relays can be set for high and low limit alarms, while the third relay is reserved for an automatic cleaning function. Additionally, the integrated datalogger allows for easy data management, enabling users to quickly download TSS measurements via a USB interface.\u003c\/p\u003e\n\u003cp\u003eIdeal for industrial water treatment, environmental monitoring, and other applications requiring precise suspended solid measurements, the Digital Online TSS Meter is both reliable and easy to use.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMultiple Outputs and Relay Functions\u003c\/strong\u003e: Includes three configurable relays and two-way analog output for flexible control and data handling.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensor Compatibility\u003c\/strong\u003e: Designed to work with a single parameter sensor, ensuring precise and focused measurement of suspended solids.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDurable Transmitter Shell\u003c\/strong\u003e: The IP65-rated shell offers protection from dust and water, making it suitable for harsh environments. For outdoor use, additional protective measures are recommended to ensure long-term durability.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003cdiv\u003e\n\u003cdiv id=\"ueditor_1568606020244\" class=\"noScrollMove\"\u003e\n\u003cdiv class=\"container\"\u003e\n\u003cdiv class=\"table-responsive\"\u003e\n\u003ctable height=\"524\" style=\"width: 78.8374%;\" class=\"table table-bordered table-hover\" data-sort=\"sortDisabled\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd style=\"width: 34.878%;\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProduct\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 64.6341%;\"\u003e\n\u003cp\u003e\u003cstrong\u003eSper Scientific #870005 Online TSS Meter\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.878%;\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003ePower Supply\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 64.6341%;\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003c\/span\u003e90 ~260V AC 50\/60Hz\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.878%;\"\u003e\u003cstrong\u003eProtection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.6341%;\"\u003e\n\u003cp\u003e\u003cspan\u003eIP65 waterproof and dust rate\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.878%;\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eDisplay Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 64.6341%;\"\u003e\n\u003cp\u003e0~1000.00mg\/L\u003c\/p\u003e\n\u003cp\u003e0~99999.00 mg\/L\u003c\/p\u003e\n\u003cp\u003e99.99~120.0 g\/L\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.878%;\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eAccuracy\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 64.6341%;\"\u003e\n\u003cp\u003e\u003cspan\u003e±2%\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.878%;\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eRelays\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 64.6341%;\"\u003e5A\/250V AC, 5A\/30V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.878%;\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCurrent Output\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 64.6341%;\"\u003e\n\u003cp\u003e\u003cspan\u003e4-20mA\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.878%;\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eDigital Communication\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 64.6341%;\"\u003e\n\u003cp\u003e\u003cspan\u003eMODBUS RS485 \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.878%;\" colspan=\"1\" rowspan=\"1\"\u003e\u003cstrong\u003eHole Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.6341%;\" colspan=\"1\" rowspan=\"1\"\u003e138*138mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.878%;\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eWarranty Period\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 64.6341%;\"\u003e\n\u003cp\u003e\u003cspan\u003e1 year\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003ch4\u003eDownloads\u003c\/h4\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cstrong\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/860031-33-i.pdf?v=1598908093\" target=\"_blank\"\u003e \u003c\/a\u003e\u003ca rel=\"noopener\" title=\"Inline TSS Meter - Users Manual\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/870005_TSS_Meter_Manual.pdf\" target=\"_blank\"\u003e\u003cimg style=\"float: left;\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/pdf-icon-63x63_480x480.png?v=1598991821\" alt=\"PDF\"\u003e \u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/860031-33-i.pdf?v=1598908093\" target=\"_blank\"\u003e\u003cbr\u003e\u003c\/a\u003e\u003ca rel=\"noopener\" title=\"Inline TSS Meter - Users Manual\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/870005_TSS_Meter_Manual.pdf\" target=\"_blank\"\u003eInstruction Manual\u003c\/a\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Sper Scientific","offers":[{"title":"Default Title","offer_id":46246436405472,"sku":"870005","price":886.78,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/inline-total-suspended-solids-meter-870005-831818.jpg?v=1752691912"},{"product_id":"digital-turbidity-meter","title":"Online Digital Turbidity Meter","description":"\u003cp\u003e\u003cb\u003eOrdering Notes:\u003cbr\u003e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003e1. ALL SPER ONLINE WATER QUALITY METERS AND SENSORS ARE SOLD SEPARATELY - Please be sure to add the appropriate sensor (listed above) when purchasing your meter - ONE METER AND SENSOR are required for a complete system. \u003c\/span\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003e\u003cspan\u003e\u003cspan style=\"color: #ff2a00;\"\u003e2. All Online Water Quality Meters and Sensors ship direct from the factory. Please allow 10-15 business days for shipping and \u003cspan style=\"caret-color: rgb(255, 42, 0);\"\u003ehandling\u003c\/span\u003e.\u003c\/span\u003e\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eThe Sper Scientific Online Digital Turbidity Meter is a state-of-the-art instrument engineered for precise and reliable continuous turbidity measurement, conforming to international standards.\u003c\/h1\u003e\n\u003cp\u003eThe \u003cstrong\u003eSper Scientific Digital Turbidity Meter\u003c\/strong\u003e is an advanced instrument engineered for precise and reliable continuous turbidity measurement, adhering to international standards in a wide variety of applications. With a measuring range of \u003cstrong\u003e0-100.00 NTU\u003c\/strong\u003e, \u003cstrong\u003e0-3000.00 NTU\u003c\/strong\u003e, \u003cstrong\u003e0-4000.00 NTU\u003c\/strong\u003e and \u003cstrong\u003e0-10000.00 NTU\u003c\/strong\u003e, this meter is versatile and suitable for a variety of applications. Its advanced RS485 Modbus RTU digital turbidity sensor ensures accuracy and durability, making it an essential tool for effective water quality management.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrecision Measurement:\u003c\/strong\u003e Achieve high accuracy with a tolerance of ±2%, ensuring reliable turbidity readings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBroad Measuring Range:\u003c\/strong\u003e Handles turbidity levels from 0.01 NTU to 10,000 NTU, accommodating various water conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLong Service Life:\u003c\/strong\u003e Designed for extended operation, minimizing the need for frequent replacements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRapid Calibration:\u003c\/strong\u003e Quick and easy calibration processes allow users to verify measurements in seconds.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDigital Connectivity:\u003c\/strong\u003e RS485 Modbus RTU interface enables seamless integration with existing monitoring systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDatalogger:\u003c\/strong\u003e Built-in datalogger for recording measurements, facilitating long-term monitoring and analysis.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection Rating:\u003c\/strong\u003e IP65 rating ensures protection against dust and water ingress, suitable for various environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDrinking and Process Water Monitoring:\u003c\/strong\u003e Ensures compliance with safety standards and optimal water quality.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcess and Filter Monitoring:\u003c\/strong\u003e Facilitates efficient operation in industrial settings, monitoring filter performance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFilter Backwash Assessment:\u003c\/strong\u003e Provides critical data for filter maintenance in waterworks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWater Quality Monitoring in Distribution Networks:\u003c\/strong\u003e Supports utilities in maintaining high water quality throughout distribution systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUtility Operations Across Industries:\u003c\/strong\u003e Versatile enough for various sectors, from manufacturing to municipal services.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRecirculation Lines:\u003c\/strong\u003e Monitors turbidity levels in recirculating systems to ensure water clarity and safety.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCooling Water Turbidity Monitoring:\u003c\/strong\u003e Essential for maintaining optimal conditions in cooling systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"easytabs-undertabs-holder\"\u003e\n\u003cb\u003e\u003c\/b\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable style=\"width: 100.091%;\" class=\"table table-bordered table-hover\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd style=\"width: 27.7064%;\" colspan=\"1\" rowspan=\"1\" width=\"137\"\u003e\u003cstrong\u003eProduct\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 71.9266%;\" colspan=\"1\" rowspan=\"1\" width=\"357\"\u003e\u003cstrong\u003eOnline Digital Turbidity Meter\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.7064%;\" width=\"137\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eMeasuring range\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 71.9266%;\" width=\"357\"\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e0-100.00,0~3000.00 , 0-4000.00,10000.00 NTU\u003cbr\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.7064%;\" colspan=\"1\" rowspan=\"1\" width=\"137\"\u003e\u003cstrong\u003eUnit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 71.9266%;\" colspan=\"1\" rowspan=\"1\" width=\"357\"\u003eNTU \/ FTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.7064%;\" width=\"137\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eAccuracy\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 71.9266%;\" width=\"357\"\u003e\n\u003cp\u003e\u003cspan\u003e± 2%\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.7064%;\" width=\"137\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003ePower\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 71.9266%;\" width=\"357\"\u003e\n\u003cp\u003e\u003cspan\u003e90 – 260V AC 50\/60Hz\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.7064%;\" width=\"137\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eCurrent output\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 71.9266%;\" width=\"357\"\u003e\n\u003cp\u003e\u003cspan\u003e4-20mA\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.7064%;\" width=\"137\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eCommunication \u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 71.9266%;\" width=\"357\"\u003e\n\u003cp\u003e\u003cspan\u003eRS485 Modbus RTU\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.7064%;\" width=\"137\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eProtection \u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 71.9266%;\" width=\"357\"\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.7064%;\" width=\"137\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eRelay\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 71.9266%;\" width=\"357\"\u003e3 relays ,5A\/250V AC      5A\/30V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.7064%;\" width=\"137\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eOverall dimension\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 71.9266%;\" width=\"357\"\u003e144×144×104mm L*W*H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.7064%;\" width=\"137\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eHole size\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 71.9266%;\" width=\"357\"\u003e\n\u003cp\u003e\u003cspan\u003e138x138 mm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.7064%;\" width=\"137\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eDatalogger\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 71.9266%;\" width=\"357\"\u003e\n\u003cp\u003e\u003cspan\u003eYES\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.7064%;\" width=\"137\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eCable length\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 71.9266%;\" width=\"357\"\u003e\n\u003cp\u003e\u003cspan\u003e3 meters\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4\u003eDownloads\u003c\/h4\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cstrong\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/860031-33-i.pdf?v=1598908093\" target=\"_blank\"\u003e \u003c\/a\u003e\u003ca rel=\"noopener\" title=\"Inline Digital Turbidity Meter - Users Manual\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/870004_Turbidity_Meter_User_Manual.pdf\" target=\"_blank\"\u003e\u003cimg alt=\"PDF\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/pdf-icon-63x63_480x480.png?v=1598991821\" style=\"float: left;\"\u003e \u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/860031-33-i.pdf?v=1598908093\" target=\"_blank\"\u003e\u003cbr\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/870004_Turbidity_Meter_User_Manual.pdf\" title=\"Inline Digital Turbidity Meter - Users Manual\" rel=\"noopener\" target=\"_blank\"\u003eInstruction Manual\u003c\/a\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Sper Scientific","offers":[{"title":"Default Title","offer_id":46246436438240,"sku":"870004","price":939.28,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/inline-digital-turbidity-meter-870004-461669.jpg?v=1752691910"},{"product_id":"wireless-module","title":"Wireless Module","description":"\u003cp class=\"p1\"\u003eGPRS gateway used by EMCP IOT cloud platform for MODBUS data automatic acquisition and transmission.\u003c\/p\u003e\n\u003ch4 class=\"p1\"\u003eDownloads\u003cspan style=\"font-size: 0.875rem;\"\u003e\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/WM-6099_DTU_Wireless_Module.pdf\" target=\"_blank\" title=\"WM-6099 Datasheet\" rel=\"noopener\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/pdf-icon-63x63_480x480.png?v=1598991821\" style=\"float: left;\" alt=\"PDF\"\u003e\u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/cr8-e.pdf?v=1704924058\" target=\"_blank\"\u003e\u003cbr\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/WM-6099_DTU_Wireless_Module.pdf\" target=\"_blank\" title=\"WM-6099 Product Datasheet\" rel=\"noopener\"\u003eProduct Datasheet\u003c\/a\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Sper Scientific","offers":[{"title":"Default Title","offer_id":47407009661152,"sku":"870012","price":1049.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/wireless-module-wm-6099-101565.jpg?v=1748137960"},{"product_id":"online-water-total-hardness-analyzer","title":"Online Total Water Hardness Analyzer","description":"\u003cdiv id=\"unit-jJRg30pax7IDugk\" type=\"text\"\u003e\n\u003cdiv class=\"ce-text_item\"\u003e\n\u003cdiv class=\"ce-text\"\u003e\n\u003ch1\u003eReal-Time Total Hardness Analysis\u003cbr\u003e\n\u003c\/h1\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"unit-dp0xU9KXb5h4sOF\" type=\"text\"\u003e\n\u003cdiv class=\"ce-text_item\"\u003e\n\u003cdiv class=\"ce-text\"\u003e\n\u003cp\u003eOnline Water Total Hardness Analyzer is an essential tool for monitoring water total hardness or carbonate hardness and total alkali through a fully automatic titration method. \u003c\/p\u003e\n\u003cdiv class=\"ce-col-w-1 ce-col-w-md-3 ce-col-w-xl-3 ce-list_item\"\u003e\n\u003cdiv class=\"ce-list_item-inner ce-d-flex\"\u003e\n\u003cdiv class=\"ce-list_text\"\u003e\n\u003cdiv class=\"ce-list_summary\"\u003e\n\u003cul\u003e\n\u003cli class=\"ce-summary\"\u003e\u003cspan\u003eReliable, exact and fully automatic analyzing hardness and alkali.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"ce-summary\"\u003eSimple commissioning with configuration assistant.\u003c\/li\u003e\n\u003cli class=\"ce-summary\"\u003e\u003cspan\u003eSelf calibrating and self monitoring in High measuring accuracy.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"ce-summary\"\u003e\u003cspan style=\"font-size: 0.875rem;\"\u003eEasy maintenance and cleaning.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"ce-summary\"\u003e\u003cspan style=\"font-size: 0.875rem;\"\u003eMinimal reagent and water consumption.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"ce-summary\"\u003e\u003cspan style=\"font-size: 0.875rem;\"\u003eMulti-colored and multi-lingual graphic display.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003eWith measurement ranges for hardness from 0.5-534ppm, and total alkali from 5.34-401ppm, this device provides accurate and repeatable results, making it ideal for quality control of water softening facilities and water blending facilities. The analyzer also offers programmable time intervals for analysis, flush time and output options such as potential-free relays, 4-20mA and CAN interface for added flexibility and convenience in monitoring water quality.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eHardness and Alkali analyzer is designed to monitor water total hardness and carbonate hardness, as well as total alkali, fully automatically through titration. The instrument is able to measure water total hardness or carbonate hardness and total alkali with high accuracy and repetition, making it ideal for recognizing hardness levels, quality control of water softening facilities, and monitoring of water blending facilities. This online water quality analyzer boasts an IP65 protection grade and is suitable for use in various industries such as agriculture, food and beverages, healthcare, pharmaceutical and more, making it an ideal choice for businesses seeking reliable water quality measurement and monitoring.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003c\/span\u003e\u003cstrong\u003ePrecise and Reliable Measurement\u003cbr\u003e\u003c\/strong\u003eOnline Water Total Hardness Analyzer offers precise and reliable measurement of total hardness in water, ensuring accurate data for effective water treatment.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong style=\"font-size: 0.875rem;\"\u003eContinuous Monitoring and Automatic Adjustments\u003cbr\u003e\u003c\/strong\u003e\u003cspan style=\"font-size: 0.875rem;\"\u003eWith its advanced technology, this Total Hardness Meter allows for continuous monitoring and automatic adjustments, guaranteeing optimal water quality at all times.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong style=\"font-size: 0.875rem;\"\u003eAccurate and Real-Time Data\u003cbr\u003e\u003c\/strong\u003e\u003cspan style=\"font-size: 0.875rem;\"\u003eThe Total Hardness Transmitter provides accurate and real-time data, allowing for quick and informed decision-making in water treatment processes.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong style=\"font-size: 0.875rem;\"\u003eSeamless Integration Into Existing Systems\u003cbr\u003e\u003c\/strong\u003e\u003cspan style=\"font-size: 0.875rem;\"\u003eThe Total Hardness Transmitter allows for seamless integration into existing water treatment systems, making it a valuable asset for any facility looking to improve water quality.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"unit-wSeat8IifqaSdy5\" class=\"ce-color-dark\" type=\"text\"\u003e\n\u003cdiv class=\"ce-text_item\"\u003e\n\u003cdiv class=\"ce-text\"\u003e\n\u003cdiv class=\"ce-col-w-1 ce-col-w-md-1 ce-col-w-xl-1 ce-list_item\"\u003e\n\u003cdiv class=\"ce-list_item-inner ce-d-flex\"\u003e\n\u003cdiv class=\"ce-list_text\"\u003e\n\u003cdiv class=\"ce-list_summary\"\u003e\n\u003cdiv class=\"ce-summary\"\u003e\n\u003cdiv class=\"ce-col-w-1 ce-col-w-md-3 ce-col-w-xl-3 ce-list_item\"\u003e\n\u003cdiv class=\"ce-list_item-inner ce-d-flex\"\u003e\n\u003cdiv class=\"ce-list_image\"\u003e\n\u003cdiv class=\"ce-image_item\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"ce-col-w-1 ce-col-w-md-3 ce-col-w-xl-3 ce-list_item\"\u003e\n\u003cdiv class=\"ce-list_item-inner ce-d-flex\"\u003e\n\u003cdiv class=\"ce-list_text\"\u003e\n\u003cdiv class=\"ce-list_summary\"\u003e\n\u003cdiv class=\"ce-summary\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"ce-summary\"\u003eSpecifications\u003c\/h4\u003e\n\u003cdiv id=\"module-jBfmb5MgcPWi0002\"\u003e\n\u003cdiv id=\"grid-bslQkHAZgSRr0000\" class=\"ce-d-flex ce-flex-wrap container\"\u003e\n\u003cdiv class=\"ce-col-12 ce-col-md-12 ce-col-xl-12\" id=\"cell-qNoMZnfyrthz0000\"\u003e\n\u003cdiv type=\"text\" id=\"unit-P6UEJCGQ38ju0000\"\u003e\n\u003cdiv class=\"ce-text_item\"\u003e\n\u003cdiv class=\"ce-text\"\u003e\n\u003cdiv class=\"table-responsive\"\u003e\n\u003ctable class=\"table table-bordered table-hover\" style=\"width: 100%; height: 804px;\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"firstRow\" style=\"height: 19px;\"\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\" style=\"width: 21.488804%; height: 19px;\"\u003e\u003cstrong\u003eProduct\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\" style=\"width: 74.883078%; height: 19px;\"\u003e\u003cstrong\u003eOnline Water Total Hardness Meter\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 38px;\"\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\" style=\"width: 21.488804%; height: 38px;\"\u003e\u003cstrong\u003eMeasurement method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\" style=\"width: 74.883078%; height: 38px;\"\u003eTitration method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 54px;\"\u003e\n\u003ctd style=\"width: 21.488804%; height: 54px;\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eWater inlet in general\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 74.883078%; height: 54px;\"\u003e\n\u003cp\u003e\u003cspan\u003eClear, colourless, free of solid particles, without gas bubbles\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 54px;\"\u003e\n\u003ctd style=\"width: 21.488804%; height: 54px;\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eMeasurement range\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 74.883078%; height: 54px;\"\u003e\n\u003cp\u003e\u003cspan\u003eTotal Hardness : 0.5-534ppm , total alkali:5.34~401ppm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35px;\"\u003e\n\u003ctd style=\"width: 21.488804%; height: 35px;\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eAccuracy\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 74.883078%; height: 35px;\"\u003e\n\u003cp\u003e\u003cspan\u003e+\/- 5% \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35px;\"\u003e\n\u003ctd style=\"width: 21.488804%; height: 35px;\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eRepetition\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 74.883078%; height: 35px;\"\u003e\n\u003cp\u003e\u003cspan\u003e±2.5%\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 54px;\"\u003e\n\u003ctd style=\"width: 21.488804%; height: 54px;\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eMeasuring water temp\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 74.883078%; height: 54px;\"\u003e\n\u003cp\u003e\u003cspan\u003e5-45℃\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 54px;\"\u003e\n\u003ctd style=\"width: 21.488804%; height: 54px;\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eWater inlet pressure\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 74.883078%; height: 54px;\"\u003e\n\u003cp\u003e\u003cspan\u003eca. 0.5 - 5 bar (max.) (Recommended 1 - 2 bar)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 140px;\"\u003e\n\u003ctd style=\"width: 21.488804%; height: 140px;\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eAnalysis start\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 74.883078%; height: 140px;\"\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eProgrammable time intervals (5 - 360 minutes)\u003c\/p\u003e\n\u003cp\u003eExternal signal\u003c\/p\u003e\n\u003cp\u003eProgrammable volume intervals\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35px;\"\u003e\n\u003ctd style=\"width: 21.488804%; height: 35px;\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eFlush time\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 74.883078%; height: 35px;\"\u003e\n\u003cp\u003e\u003cspan\u003eProgrammable flush time (15 - 1800 seconds)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 124px;\"\u003e\n\u003ctd style=\"width: 21.488804%; height: 124px;\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eSignal Outputs\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 74.883078%; height: 124px;\"\u003e\n\u003cp\u003e2 x potential-free Relays (max. 250 Vac \/ Vdc; 4A（as potential free output NC\/NO）)\u003c\/p\u003e\n\u003cp\u003e0\/4-20mA\u003c\/p\u003e\n\u003cp\u003eCAN interface\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35px;\"\u003e\n\u003ctd style=\"width: 21.488804%; height: 35px;\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003cstrong\u003e\u003cspan\u003ePower\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 74.883078%; height: 35px;\"\u003e\n\u003cp\u003e\u003cspan\u003e90 - 260 VAC (47 - 63Hz)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 54px;\"\u003e\n\u003ctd style=\"width: 21.488804%; height: 54px;\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003ePower consumption\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 74.883078%; height: 54px;\"\u003e\n\u003cp\u003e\u003cspan\u003e25 VA (in operation), 3.5 VA (stand by)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 38px;\"\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\" style=\"width: 21.488804%; height: 38px;\"\u003e\u003cstrong\u003eProtection grade\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\" style=\"width: 74.883078%; height: 38px;\"\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35px;\"\u003e\n\u003ctd style=\"width: 21.488804%; height: 35px;\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 74.883078%; height: 35px;\"\u003e\n\u003cp\u003e\u003cspan\u003e300x300x200 mm (WxHxD)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHardness Reagents \u0026amp; Measurement Ranges\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"table-responsive\"\u003e\n\u003ctable style=\"width: 100%; height: 247px;\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"firstRow\" style=\"height: 19px;\"\u003e\n\u003ctd width=\"142\" valign=\"top\" style=\"width: 22.866345%; height: 19px;\"\u003eReagent type\u003c\/td\u003e\n\u003ctd width=\"152\" valign=\"top\" style=\"width: 24.476651%; height: 19px;\"\u003e°dH\u003c\/td\u003e\n\u003ctd width=\"174\" valign=\"top\" style=\"width: 28.019324%; height: 19px;\"\u003e°F\u003c\/td\u003e\n\u003ctd width=\"176\" valign=\"top\" style=\"width: 28.341385%; height: 19px;\"\u003eppm CaCO3\u003c\/td\u003e\n\u003ctd width=\"194\" valign=\"top\" style=\"width: 31.239936%; height: 19px;\"\u003emmol\/l\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 38px;\"\u003e\n\u003ctd width=\"142\" valign=\"top\" style=\"width: 22.866345%; height: 38px;\"\u003eTH5001\u003c\/td\u003e\n\u003ctd width=\"152\" valign=\"top\" style=\"width: 24.476651%; height: 38px;\"\u003e0.03-0.3\u003c\/td\u003e\n\u003ctd width=\"174\" valign=\"top\" style=\"width: 28.019324%; height: 38px;\"\u003e0.053-0.534\u003c\/td\u003e\n\u003ctd width=\"176\" valign=\"top\" style=\"width: 28.341385%; height: 38px;\"\u003e0.534-5.340 \u003c\/td\u003e\n\u003ctd width=\"194\" valign=\"top\" style=\"width: 31.239936%; height: 38px;\"\u003e0.005-0.053\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 38px;\"\u003e\n\u003ctd width=\"142\" valign=\"top\" style=\"width: 22.866345%; height: 38px;\"\u003eTH5003\u003c\/td\u003e\n\u003ctd width=\"152\" valign=\"top\" style=\"width: 24.476651%; height: 38px;\"\u003e0.09-0.9\u003c\/td\u003e\n\u003ctd width=\"174\" valign=\"top\" style=\"width: 28.019324%; height: 38px;\"\u003e0.160-1.602\u003c\/td\u003e\n\u003ctd width=\"176\" valign=\"top\" style=\"width: 28.341385%; height: 38px;\"\u003e1.602-16.02\u003c\/td\u003e\n\u003ctd width=\"194\" valign=\"top\" style=\"width: 31.239936%; height: 38px;\"\u003e0.016-0.160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 38px;\"\u003e\n\u003ctd width=\"142\" valign=\"top\" style=\"width: 22.866345%; height: 38px;\"\u003eTH5010\u003c\/td\u003e\n\u003ctd width=\"152\" valign=\"top\" style=\"width: 24.476651%; height: 38px;\"\u003e0.3-3.0\u003c\/td\u003e\n\u003ctd width=\"174\" valign=\"top\" style=\"width: 28.019324%; height: 38px;\"\u003e0.534-5.340\u003c\/td\u003e\n\u003ctd width=\"176\" valign=\"top\" style=\"width: 28.341385%; height: 38px;\"\u003e5.340-53.40\u003c\/td\u003e\n\u003ctd width=\"194\" valign=\"top\" style=\"width: 31.239936%; height: 38px;\"\u003e0.053-0.535\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 38px;\"\u003e\n\u003ctd width=\"142\" valign=\"top\" style=\"width: 22.866345%; height: 38px;\"\u003eTH5030\u003c\/td\u003e\n\u003ctd width=\"152\" valign=\"top\" style=\"width: 24.476651%; height: 38px;\"\u003e0.9-9.0\u003c\/td\u003e\n\u003ctd width=\"174\" valign=\"top\" style=\"width: 28.019324%; height: 38px;\"\u003e1.602-16.02\u003c\/td\u003e\n\u003ctd width=\"176\" valign=\"top\" style=\"width: 28.341385%; height: 38px;\"\u003e16.02-160.2\u003c\/td\u003e\n\u003ctd width=\"194\" valign=\"top\" style=\"width: 31.239936%; height: 38px;\"\u003e0.160-1.602\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 38px;\"\u003e\n\u003ctd width=\"142\" valign=\"top\" style=\"width: 22.866345%; height: 38px;\"\u003eTH5050\u003c\/td\u003e\n\u003ctd width=\"152\" valign=\"top\" style=\"width: 24.476651%; height: 38px;\"\u003e1.5-15\u003c\/td\u003e\n\u003ctd width=\"174\" valign=\"top\" style=\"width: 28.019324%; height: 38px;\"\u003e2.67-26.7\u003c\/td\u003e\n\u003ctd width=\"176\" valign=\"top\" style=\"width: 28.341385%; height: 38px;\"\u003e26.7-267.0\u003c\/td\u003e\n\u003ctd width=\"194\" valign=\"top\" style=\"width: 31.239936%; height: 38px;\"\u003e0.267-2.670\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 38px;\"\u003e\n\u003ctd width=\"142\" valign=\"top\" style=\"width: 22.866345%; height: 38px;\"\u003eTH5100\u003c\/td\u003e\n\u003ctd width=\"152\" valign=\"top\" style=\"width: 24.476651%; height: 38px;\"\u003e3.0-30\u003c\/td\u003e\n\u003ctd width=\"174\" valign=\"top\" style=\"width: 28.019324%; height: 38px;\"\u003e5.340-53.40\u003c\/td\u003e\n\u003ctd width=\"176\" valign=\"top\" style=\"width: 28.341385%; height: 38px;\"\u003e53.40-534.0\u003c\/td\u003e\n\u003ctd width=\"194\" valign=\"top\" style=\"width: 31.239936%; height: 38px;\"\u003e0.535-5.340\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAlkali Reagents \u0026amp; Measurement Ranges\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cdiv class=\"table-responsive\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd width=\"419\" valign=\"top\"\u003eReagents model\u003c\/td\u003e\n\u003ctd width=\"417\" valign=\"top\"\u003eMeasuring range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"419\" valign=\"top\"\u003eTC5010\u003c\/td\u003e\n\u003ctd width=\"417\" valign=\"top\"\u003e5.34~134 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"419\" valign=\"top\"\u003eTC5015\u003c\/td\u003e\n\u003ctd width=\"417\" valign=\"top\"\u003e8.01~205ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"419\" valign=\"top\"\u003eTC5020\u003c\/td\u003e\n\u003ctd width=\"417\" valign=\"top\"\u003e10.7~267ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"419\" valign=\"top\"\u003eTC5030\u003c\/td\u003e\n\u003ctd width=\"417\" valign=\"top\"\u003e16.0~401ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4\u003eDownloads\u003c\/h4\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cstrong\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/860031-33-i.pdf?v=1598908093\" target=\"_blank\"\u003e \u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/Online-Water-Hardness-Analyzer-Manual.pdf\" target=\"_blank\" title=\"Online Total Water Hardness Analyzer - Users Manual\" rel=\"noopener\"\u003e\u003cimg alt=\"PDF\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/pdf-icon-63x63_480x480.png?v=1598991821\" style=\"float: left;\"\u003e \u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/860031-33-i.pdf?v=1598908093\" target=\"_blank\"\u003e\u003cbr\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/Online-Water-Hardness-Analyzer-Manual.pdf\" target=\"_blank\" title=\"Online Total Water Hardness Users Manual\" rel=\"noopener\"\u003eInstruction Manual\u003c\/a\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Sper Scientific","offers":[{"title":"Default Title","offer_id":47596813287648,"sku":"870013","price":9087.8,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/online-water-total-hardness-analyzer-870013-3359228.jpg?v=1753329751"},{"product_id":"industrial-dissolved-oxygen-bioprocess-monitor","title":"Industrial Dissolved Oxygen Bioprocess Monitor","description":"\u003ch1\u003eIndustrial Dissolved Oxygen Monitor is ideal for effluent treatment, pure water, boiler water, surface water, electroplating, chemical processing, pharmaceuticals, food production, environmental monitoring, breweries and fermentation applications.\u003c\/h1\u003e\n\u003cp\u003eFeatures a large dot-matrix display with intuitive operation interface designed for ease of use. Built-in data storage, viewing, and export functions with configurable storage cycles. RS485 network connectivity enables remote monitoring across multiple locations. Advanced lightning protection safeguards equipment reliability in demanding environments. Firmware supports online upgrades for simplified maintenance and feature updates. Flexible mounting options accommodate panel, wall or pipe installation to fit your facility layout.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLarge dot-matrix display with intuitive interface for straightforward operation and clear visibility.\u003cbr\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eBuilt-in data storage, viewing, and export capabilities with user-configurable storage cycles.\u003cbr\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eRS485 interface enables network monitoring and remote oversight across multiple locations.\u003cbr\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eAdvanced lightning protection design ensures reliable equipment performance in industrial environments.\u003cbr\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eFirmware supports online upgrades for convenient maintenance and system enhancements.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring Range\u003c\/td\u003e\n\u003ctd\u003e0.0 to 200.0%\u003c\/td\u003e\n\u003ctd\u003e0.00 to 20.00 ppm; 0.0 to 200.0 ppb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1\u003c\/td\u003e\n\u003ctd\u003e0.01\/0.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±0.2\u003c\/td\u003e\n\u003ctd\u003e±0.02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Compensation\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003ePt 1000\/NTC22K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-10.0 to +130.0°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Compensation Range\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-10.0 to +130.0°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.1°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e±0.2°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrode Current Range\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-2.0 to +400 nA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrode Current Accuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e±0.005 nA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePolarization\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-0.675 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure Range\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e500 to 9999 mbar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity Range\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.00 to 50.00 ppt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature Range\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0 to +70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-20 to +70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eBacklit dot matrix\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDO Current Output 1\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eIsolated 4–20 mA output; maximum load 500 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Current Output 2\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eIsolated 4–20 mA output; maximum load 500 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Output Accuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e±0.05 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRS485\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eModbus RTU protocol\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBaud Rate\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e9600\/19200\/38400\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Relay Contact Capacity\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e5 A at 250 VAC; 5 A at 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCleaning Setting\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eON: 1–1000 seconds; OFF: 0.1–1000.0 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOne Multifunction Relay\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eCleaning\/period alarm\/error alarm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Delay\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0–120 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Logging Capacity\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e500,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLanguage Selection\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eEnglish, traditional Chinese and simplified Chinese\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWaterproof Grade\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e90–260 VAC; power consumption \u0026lt;5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003ePanel, wall or pipe installation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.85 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Sper Scientific","offers":[{"title":"Default Title","offer_id":67893279260896,"sku":"SSMDO-100","price":786.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/industrial-dissolved-oxygen-bioprocess-monitor-ssmdo-100-4054598.jpg?v=1791990915"},{"product_id":"sper-scientific-ph-conductivity-dual-channel-online-analyzer","title":"Online Dual-Channel pH\/Conductivity Analyzer","description":"\u003ch1\u003eSper Scientific Online pH\/Conductivity Analyzer monitors one analog pH or ORP sensor and one analog conductivity sensor simultaneously.\u003c\/h1\u003e\n\u003cp\u003e\u003cstrong\u003eIt combines two measurement channels in a compact panel-mounted instrument for continuous water quality monitoring in industrial processes, water treatment and wastewater applications.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe pH\/ORP channel supports acidity or oxidation-reduction potential measurement, while the conductivity channel provides conductivity, TDS, salinity or resistivity readings. Temperature measurement and compensation support consistent process evaluation when used with compatible probes. Actual measurement range, process temperature limits and overall system performance depend on the sensors selected.\u003c\/p\u003e\n\u003cp\u003eA 3.1-inch backlit LCD displays process readings, while the front-panel buttons provide access to measurement and output settings. Two configurable 4–20 mA outputs and RS485 Modbus RTU communication support integration with PLCs and plant monitoring systems. Three relay outputs provide alarm and supported control functions.\u003c\/p\u003e\n\u003cp\u003eHistorical data records and trend curves help review process changes. Recording intervals can be set from 1–999 minutes, and stored data can be exported to a computer over USB. The ABS enclosure has an IP65 protection rating, with standard 100–240 VAC power and an optional 24 VDC configuration.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSimultaneous pH\/ORP and conductivity monitoring with compatible analog sensors\u003c\/li\u003e\n\u003cli\u003eConductivity-channel functions include EC, TDS, salinity and resistivity\u003c\/li\u003e\n\u003cli\u003eTemperature compensation with multiple supported temperature sensor types\u003c\/li\u003e\n\u003cli\u003e3.1-inch backlit LCD and front-panel controls\u003c\/li\u003e\n\u003cli\u003eTwo configurable 4–20 mA outputs\u003c\/li\u003e\n\u003cli\u003eRS485 Modbus RTU communication for PLC integration\u003c\/li\u003e\n\u003cli\u003eThree relay outputs for alarm and supported control functions\u003c\/li\u003e\n\u003cli\u003eHistorical data logging and trend curve display\u003c\/li\u003e\n\u003cli\u003eAdjustable data recording intervals from 1–999 minutes\u003c\/li\u003e\n\u003cli\u003eUSB export of stored records\u003c\/li\u003e\n\u003cli\u003eIP65-rated ABS enclosure\u003c\/li\u003e\n\u003cli\u003eStandard AC power with an optional 24 VDC version\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"text-align: left;\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e870002D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eMeasurement channels\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003eOne analog pH\/ORP sensor and one analog conductivity sensor, operating simultaneously\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003epH range\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e−2.00 to 16.00 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eORP range\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e−2,000 to +2,000 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eConductivity range\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e0–2,000,000 µS\/cm (0–2,000 mS\/cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eTDS range\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e0–130,000 mg\/L (ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eResistivity range\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e0–20 MΩ·cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eSalinity\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003eSupported; usable range depends on sensor and configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eChannel 1 temperature range\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e−30.0 to 130.0°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eChannel 2 temperature range\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e−40.0 to 200.0°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003epH: ±0.01 pH; ORP: ±1 mV; conductivity: ±2%; temperature: ±0.5°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eTemperature compensation inputs\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003eNTC30k, NTC22k, NTC10k, Pt1000 and NTC2.252k\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eDisplay\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e3.1-inch backlit digital LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eAnalog outputs\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003eTwo configurable 4–20 mA outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eDigital interface\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003eRS485, Modbus RTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eRelays\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003eThree; contacts rated 5 A at 250 VAC or 5 A at 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eData logging\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003eHistorical records and curves; adjustable recording interval 1–999 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eData export\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003eUSB connection to computer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eStandard power\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e100–240 VAC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eOptional power\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003ePower consumption\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e4 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eHousing \/ protection\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003eABS plastic \/ IP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eDimensions \/ weight\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e144 × 144 × 104 mm \/ 0.9 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eOperating environment\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e−20 to 50°C; ≤95% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eStorage environment\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e−40 to 70°C; ≤95% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eAltitude \/ overvoltage category \/ pollution degree\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e≤2,000 m \/ II \/ 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eLanguages\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003eEnglish, Simplified Chinese, Traditional Chinese and Russian\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eCountry of origin\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003eChina\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eListed measurement limits are controller capabilities. Select compatible electrodes with ranges, temperature ratings and process connections appropriate for the application.\u003c\/p\u003e\n\u003ch4\u003eDownloads\u003c\/h4\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cstrong\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/800002-i.pdf?v=1598908085\" target=\"_blank\"\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/pdf-icon-63x63_480x480.png?v=1598991821\" style=\"float: left;\" alt=\"PDF\"\u003e \u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/800002-i.pdf?v=1598908085\" target=\"_blank\"\u003e\u003cbr\u003eSper Scientific 870002D Instruction Manual\u003c\/a\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003eFAQs\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eCan the DCA130 measure pH and conductivity at the same time?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. It supports one pH\/ORP sensor and one conductivity sensor simultaneously.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan it measure pH and ORP simultaneously?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe first channel uses a pH or ORP sensor. The second channel is intended for conductivity measurements.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat measurements are available on the conductivity channel?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eConductivity, TDS, salinity and resistivity functions are supported. Available ranges depend on the electrode and configuration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan it connect to a PLC?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The analyzer provides RS485 Modbus RTU and two configurable 4–20 mA outputs.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan historical readings be exported?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. Stored data can be exported to a computer over USB. Logging pauses while the USB connection is active and resumes after disconnection.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAre sensors included?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSensor inclusion has not been specified. Select the required pH\/ORP and conductivity probes for your installation and confirm the package before ordering.\u003c\/p\u003e","brand":"Sper Scientific","offers":[{"title":"Default Title","offer_id":68104970076384,"sku":"870002D","price":947.5,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/online-dual-channel-phconductivity-analyzer-870002d-1476214.jpg?v=1793360781"},{"product_id":"online-multi-parameter-water-quality-analyzer","title":"Online Multi-Parameter Water Quality Analyzer","description":"\u003ch1\u003eThe Sper Scientific 870001S Multi-Parameter Water Quality Analyzer combines online pH, residual chlorine, turbidity and temperature monitoring in an integrated cabinet.\u003c\/h1\u003e\n\u003cp\u003eDesigned for waterworks, municipal water supply and drinking water monitoring in public facilities, it brings key water quality measurements together in one installation.\u003c\/p\u003e\n\u003cp\u003eThe compact cabinet simplifies equipment placement and reduces the space required for a monitoring station. A front-mounted display provides access to process information, while the internal arrangement groups the measurement components, sample tubing and connections for service access. Online monitoring and stored data help operators review water quality conditions and changes over time.\u003c\/p\u003e\n\u003cp\u003eRS485 communication supports connection to compatible monitoring equipment. The system is intended for water supply applications under normal temperature and pressure conditions. Parameter customization is available at the product-family level; confirm the required sensors and configuration for the installation before ordering.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIntegrated online monitoring of pH, residual chlorine, turbidity and temperature\u003c\/li\u003e\n\u003cli\u003eCabinet-based design simplifies transportation and installation\u003c\/li\u003e\n\u003cli\u003eFront-mounted display for water quality information\u003c\/li\u003e\n\u003cli\u003eOnline data monitoring and storage\u003c\/li\u003e\n\u003cli\u003eRS485 communication interface\u003c\/li\u003e\n\u003cli\u003eAccessible internal measurement components and sample connections\u003c\/li\u003e\n\u003cli\u003eCompact 400 × 600 × 220 mm cabinet\u003c\/li\u003e\n\u003cli\u003eSuitable for waterworks, municipal supply and drinking water monitoring stations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"text-align: left;\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003ePart number\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e870001S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eMeasurement parameters\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003epH, residual chlorine, turbidity and temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003epH range \/ resolution \/ accuracy\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e0–14.00 pH \/ 0.01 pH \/ ±0.1 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eResidual chlorine range \/ resolution \/ accuracy\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e0–2.00 mg\/L \/ 0.01 mg\/L \/ ±3% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eTurbidity range \/ resolution\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e0–2.00 NTU \/ 0.01 NTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eTurbidity accuracy\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e±2% or ±0.02 NTU, whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eTemperature range \/ resolution \/ accuracy\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e0–60°C \/ 0.1°C \/ ±0.5°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eCommunication interface\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003eRS485\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003ePower supply\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e220 VAC ±10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eOperating ambient temperature\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e0–50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eHumidity condition\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e≤85% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eCabinet dimensions\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e400 × 600 × 220 mm (L × H × W)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"Sper Scientific","offers":[{"title":"Default Title","offer_id":68119237656800,"sku":"870001S","price":4300.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/online-multi-parameter-water-quality-analyzer-870001s-3724419.jpg?v=1793360780"},{"product_id":"open-channel-flow-meter","title":"Open Channel Flow Meter","description":"\u003ch1\u003eThe Sper Scientific Open Channel Flow Meter calculates water flow from measured liquid level and the level-to-flow relationship of a compatible measuring weir.\u003c\/h1\u003e\n\u003cp\u003e\u003cstrong\u003eApplications include wastewater discharge points and municipal sewer channels.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003eThe wall-mounted ultrasonic open channel flow meter measures water level without contacting the liquid. A sensor transmits ultrasonic pulses toward the water surface and measures the time taken for the echoes to return. The meter uses this distance measurement to determine water level, then calculates flow using the level-to-flow relationship for the configured weir or flume.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe display shows instantaneous flow rate, accumulated flow and water level. Non-contact measurement keeps the sensor away from wastewater, reducing exposure to contamination and corrosion. Accurate flow measurement requires a compatible measuring structure, proper installation and suitable free-flow conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis method is used to monitor water and wastewater flow in open channels, including wastewater treatment plant discharge channels, industrial effluent outlets and municipal sewer systems. Accurate results depend on proper weir installation, correct level measurement and selection of the appropriate flow calculation.\u003c\/span\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eApplications\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eWater and wastewater treatment\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003ePower generation and mining\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFood processing\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003ePetrochemical facilities\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eIntake channels, drainage channels and discharge outlets\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eStream and river monitoring at suitable measuring structures\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eIntegration with process monitoring and control systems\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eMain Features\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eWater level, instantaneous flow and accumulated flow display\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSettings backup and restoration\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eConfigurable analog output\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eDigital filtering and echo recognition\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eManually configurable suppression of fixed interference echoes\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCustom mathematical calculations\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAdjustable sound velocity for specific measurement conditions\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLevel-to-volume conversion for configured vessels; weight calculation requires appropriate volume and density settings\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eBluetooth, GPRS and Wi-Fi connectivity, depending on configuration\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eOptional custom serial data format, specified when ordering\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eOptional Mini SD card data logging, USB output and microprinter support, specified when ordering\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003ePart number\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e870023\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eFlow range\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e0.1 L\/s–10 m³\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eFlow accuracy\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e±1–3%, depending on measuring weir\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eMaximum level\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e3 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eLevel accuracy\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e±0.3% within 3 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eResolution\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e1 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eTotalizer\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e12-digit decimal; resets when accumulation capacity is reached\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eOutput\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e4–20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eCommunication\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003eRS485 Modbus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eRelay options\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e1–4 outputs; please specify when ordering\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003ePower options\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e220 VAC, 50 Hz or 12–36 VDC, 3 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cbr\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eSignal input (Please specify when ordering)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"padding-left: 40px;\"\u003eDigital signal: RS485 (supports Modbus protocol)\u003cbr\u003eCurrent signal: 4-20mA\u003cbr\u003eTransducer signal: voltage\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSignal output (Please specify when ordering)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"padding-left: 40px;\"\u003eVoltage output: DC12V or 24V\u003cbr\u003eAnalog output signal: 0 ~ 20mA; 4 ~ 20mA load \u0026gt; 300Ω; 0 ~ 5V; 0 ~ 10V\u003cbr\u003eDigital output: RS485 (support Modbus); USB, memory card 8G\u003cbr\u003eWireless transmission: built-in GPRS wireless communication optional SMS data prompt (acquisition system can be customized)\u003cbr\u003eSwitch output: two NPN\/3 relays (AC: 5A 250V DC: 10A 24V)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePower\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"padding-left: 40px;\"\u003eWorking voltage: DC12-24V or AC160V~250V\u003cbr\u003eNormal power consumption: \u0026lt;5W\u003c\/p\u003e\n\u003ch4\u003eDownloads\u003c\/h4\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cstrong\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/800002-i.pdf?v=1598908085\" target=\"_blank\"\u003e \u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/OCFM_Open-channel_flow_meter.doc\" title=\"Open Channel Flow Meter Users Manual\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/pdf-icon-63x63_480x480.png?v=1598991821\" style=\"float: left;\" alt=\"PDF\"\u003e\u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/800002-i.pdf?v=1598908085\" target=\"_blank\"\u003e\u003cbr\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/OCFM_Open-channel_flow_meter.doc\" title=\"Open Channel Flow Meter Users Manual\" rel=\"noopener\" target=\"_blank\"\u003eSper Scientific Open Channel Flow Meter Instruction Manual\u003c\/a\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eFAQs\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eHow is flow determined?\u003c\/strong\u003e\u003cbr\u003eFrom liquid level and the selected weir’s level-to-flow relationship.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat affects flow accuracy?\u003c\/strong\u003e\u003cbr\u003eThe measuring weir used in the installation.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"Sper Scientific","offers":[{"title":"Default Title","offer_id":68122682392800,"sku":"870023","price":350.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/open-channel-flow-meter-870023-9595764.webp?v=1793360777"},{"product_id":"explosion-proof-online-ph-orp-analyzer","title":"Explosion-Proof Online pH\/ORP Analyzer","description":"\u003ch1\u003eThe Sper Scientific Explosion-Proof Online pH\/ORP Analyzer supports continuous pH or ORP and temperature monitoring with a compatible analog electrode.\u003c\/h1\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cstrong\u003eThe Sper Scientific 870002E\u003c\/strong\u003e\u003cspan\u003e\u003cstrong\u003e monitors pH or oxidation-reduction potential (ORP) in industrial water and process solutions.\u003c\/strong\u003e Its online design provides continuous readings, helping operators track changing conditions throughout a process.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eConnect a compatible analog pH or ORP sensor to measure the selected parameter along with temperature. The analyzer sends a 4–20 mA signal to connected monitoring equipment, allowing readings to be incorporated into a plant’s process monitoring system.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe 870002E is suited to applications such as wastewater treatment, drinking water processing, chemical production and power generation. Its explosion-proof design and low power consumption support use in industrial environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eFeatures\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eContinuous online monitoring\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e of pH or ORP and temperature\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eAnalog sensor compatibility\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e for the selected measurement\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eTwo-wire 4–20 mA output\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e for connection to monitoring equipment\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eExplosion-proof design\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e for suitable industrial applications\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eLow power consumption\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e for continuous operation\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch4\u003e\u003cspan style=\"font-family: -apple-system, BlinkMacSystemFont, 'San Francisco', 'Segoe UI', Roboto, 'Helvetica Neue', sans-serif; font-size: 0.875rem;\"\u003eSpecifications\u003c\/span\u003e\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003ePart number\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e\u003cstrong\u003e870002E\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003epH range \/ accuracy\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e−2 to 16 pH \/ ±0.05 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eORP range \/ accuracy\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e−2,000 to +2,000 mV \/ ±1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eTemperature range \/ accuracy\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e0–130°C \/ ±0.5°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003ePower\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e18–30 VDC; 0.66 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eOutput\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003eTwo-wire 4–20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eHousing\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003eAluminum; IP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eOperating environment\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e−20 to +50°C; 0–95% RH, noncondensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eStorage environment\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e−40 to +70°C; 0–95% RH, noncondensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"Sper Scientific","offers":[{"title":"Default Title","offer_id":68185306169568,"sku":"870002E","price":1350.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/explosion-proof-online-phorp-analyzer-870002e-8819373.jpg?v=1793360781"},{"product_id":"explosion-proof-two-wire-online-conductivity-analyzer","title":"Explosion-Proof Two-Wire Online Conductivity Analyzer","description":"\u003ch1\u003eThe Sper Scientific 870003E Two-Wire Explosion-Proof Online Conductivity Analyzer supports continuous conductivity, salinity, TDS, resistivity and temperature monitoring with a compatible analog sensor.\u003c\/h1\u003e\n\u003cp\u003e\u003cstrong\u003eThe Sper Scientific 870003E 2-Wire Explosion-Proof Online Electrical Conductivity Analyzer\u003c\/strong\u003e\u003cspan\u003e\u003cstrong\u003e provides continuous monitoring of conductivity, salinity, total dissolved solids (TDS), resistivity and temperature in water and process solutions.\u003c\/strong\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eUsed with a compatible analog conductivity sensor, it is suitable for wastewater treatment, power generation, chemical processing, pharmaceutical manufacturing, food processing and drinking water applications. \u003c\/span\u003e\u003cspan\u003eA two-wire 4–20 mA output connects the analyzer to process monitoring equipment, while low power consumption supports continuous operation in industrial installations.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eConstruction\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe analyzer features a die-cast aluminum housing with an IP65 rating for protection against dust and water. Its construction supports use in demanding industrial environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eFeatures\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eContinuous monitoring of conductivity, salinity, TDS, resistivity and temperature\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCompatible with analog conductivity sensors\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eTwo-wire 4–20 mA output\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLow power consumption\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eDie-cast aluminum housing with IP65 protection\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eExplosion-proof design with manufacturer-listed \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eEx ia IIC T6 Ga\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e marking\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan style=\"font-family: -apple-system, BlinkMacSystemFont, 'San Francisco', 'Segoe UI', Roboto, 'Helvetica Neue', sans-serif; font-size: 0.875rem;\"\u003eSpecifications\u003c\/span\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003ePart number\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e870003E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eConductivity, K = 0.01\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e0.01–20 µS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eConductivity, K = 0.1\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e0.1–200 µS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eConductivity, K = 1.0\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e1–2,000 µS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eConductivity, K = 10.0\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e10–20,000 µS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eSalinity\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e0.00–80.00 ppt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eTDS\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e0–130,000 mg\/L (ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eResistivity\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e0–20 MΩ·cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eTemperature inputs \/ ranges\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003ePt100, Pt1000 or NTC10k: −40 to +200°C; NTC2.252k: −30 to +150°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eAccuracy\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e±0.5% F.S.; temperature ±0.3°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eOutput\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003eOne two-wire 4–20 mA output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eOutput error\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e≤±0.3% F.S. or ±0.05 mA, whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003ePower\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e18–30 VDC; 0.66 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eHousing\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003eDie-cast aluminum; IP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eDimensions \/ weight\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e144 × 144 × 147 mm; 1.35 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eOperating environment\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e−20 to +60°C; ≤95% RH, noncondensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eStorage temperature\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e−40 to +70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Sper Scientific","offers":[{"title":"Default Title","offer_id":68188570747104,"sku":"870003E","price":1500.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/explosion-proof-two-wire-online-conductivity-analyzer-870003e-3346998.jpg?v=1793360779"},{"product_id":"online-conductivity-and-acid-base-analyzer-870009a","title":"Online Conductivity and Acid\/Base Analyzer","description":"\u003ch1\u003eThe Sper Scientific 870009A Online Conductivity and Acid\/Base Analyzer continuously monitors conductivity, resistivity, salinity, total dissolved solids (TDS), temperature and the concentration of selected chemical solutions.\u003c\/h1\u003e\n\u003cp\u003e\u003cstrong\u003ePaired with a compatible digital conductivity sensor, it supports applications from pure water systems to industrial process water and wastewater treatment. \u003c\/strong\u003eA backlit display provides local readings. Dual analog outputs and RS485 Modbus RTU communication connect the controller to process monitoring systems. Alarm and cleaning functions support routine operation, while historical data recording helps users review measurement trends.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMultiple measurement modes with compatible digital sensors\u003c\/li\u003e\n\u003cli\u003eTwo 4–20 mA outputs and RS485 Modbus RTU\u003c\/li\u003e\n\u003cli\u003eHigh\/low alarms and cleaning relay function\u003c\/li\u003e\n\u003cli\u003eHistorical data recording and retention of settings after power loss\u003c\/li\u003e\n\u003cli\u003ePanel-mount controller with IP65 protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003ePart number\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e\u003cstrong\u003e870009A\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eDisplay\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e3.1-inch backlit LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003ePower supply\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e100–240 VAC, 50\/60 Hz; 24 V option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003ePower consumption\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e4 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eOutputs\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003eTwo 4–20 mA outputs; RS485 Modbus RTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eRelays\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003eHigh\/low alarm and cleaning function; 5 A at 250 VAC or 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eConductivity\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e0–2,000,000 µS\/cm (0–2,000 mS\/cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eSalinity\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e0–80.00 ppt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eTDS\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e0–60,000 mg\/L (ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eResistivity\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e0–20.00 MΩ·cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eTemperature\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e0–150.0°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eAcid\/base concentration\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003eCompound-dependent; see ranges below\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eHousing \/ protection\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003eABS plastic; IP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eDimensions \/ weight\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e144 × 144 × 104 mm; 0.9 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eOperating conditions\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e−40 to 70°C; ≤95% RH, noncondensing; altitude ≤2,000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eController ranges are shown; actual performance and usable ranges depend on the selected sensor.\u003c\/p\u003e\n\u003ch4\u003eAcid, Base and Salt Concentration Ranges\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eHCl\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e0–18%; 22–39% at 25°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eHNO₃\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e0–29%; 35–96% at 25°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eH₂SO₄\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e0–29%; 30–83%; 93–100% at 10°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eNaCl\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e0–26% at 20°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eNaOH\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e0–14%; 18–50% at 25°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eKOH\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e0–29%; 29–48% at 25°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eHF\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e0–36% at 25°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eCaCl₂\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e0–25%; 25–40% at 25°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eCH₃COOH\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e0–17%; 17–70% at 25°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eH₃PO₄\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e0–35% at 25°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eNa₂CO₃\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e0–19% at 25°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Sper Scientific","offers":[{"title":"Default Title","offer_id":68205136380128,"sku":"870009A","price":997.5,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/online-conductivity-and-acidbase-analyzer-870009a-8652391.jpg?v=1793360777"},{"product_id":"online-industrial-silicate-analyzer","title":"Online Industrial Silicate Analyzer","description":"\u003ch1\u003eThe Sper Scientific \u003cmeta charset=\"utf-8\"\u003eOnline Industrial Silicate Analyzer monitors silicate levels in process water using automated chemical reaction and optical detection.\u003c\/h1\u003e\n\u003cp\u003eIt supports applications such as power plant feedwater, steam-cycle monitoring and industrial water treatment where low concentrations must be tracked. A color LCD displays results and historical trends, while the 4–20 mA output and RS485 communication connect the analyzer to monitoring equipment. Automatic calibration can be scheduled to suit the application. Optional multi-channel configurations allow the analyzer to measure multiple sample streams.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAutomated chemical reaction and optical measurement\u003c\/li\u003e\n\u003cli\u003eColor display with English-language menus and trend curves\u003c\/li\u003e\n\u003cli\u003eHistorical data recording for up to 30 days\u003c\/li\u003e\n\u003cli\u003eAutomatic calibration with adjustable interval\u003c\/li\u003e\n\u003cli\u003eOne to six sample channels available by configuration\u003c\/li\u003e\n\u003cli\u003eAudible and relay alarms\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable style=\"width: 100%; height: 313.501px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth style=\"text-align: left; width: 28.0128%; height: 19.5938px;\"\u003ePart number\u003c\/th\u003e\n\u003ctd style=\"text-align: left; width: 69.665%; height: 19.5938px;\"\u003e\u003cstrong\u003e870018\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth style=\"text-align: left; width: 28.0128%; height: 19.5938px;\"\u003eMeasurement ranges\u003c\/th\u003e\n\u003ctd style=\"text-align: left; width: 69.665%; height: 19.5938px;\"\u003e0–20, 0–100 or 0–2,000 µg\/L; 0–5,000 µg\/L special range available\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth style=\"text-align: left; width: 28.0128%; height: 19.5938px;\"\u003eAccuracy\u003c\/th\u003e\n\u003ctd style=\"text-align: left; width: 69.665%; height: 19.5938px;\"\u003e±1% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth style=\"text-align: left; width: 28.0128%; height: 19.5938px;\"\u003eRepeatability\u003c\/th\u003e\n\u003ctd style=\"text-align: left; width: 69.665%; height: 19.5938px;\"\u003e±1% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth style=\"text-align: left; width: 28.0128%; height: 19.5938px;\"\u003eDrift\u003c\/th\u003e\n\u003ctd style=\"text-align: left; width: 69.665%; height: 19.5938px;\"\u003e≤±1% of full scale per 24 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth style=\"text-align: left; width: 28.0128%; height: 19.5938px;\"\u003eResponse\u003c\/th\u003e\n\u003ctd style=\"text-align: left; width: 69.665%; height: 19.5938px;\"\u003e12 minutes initial; 10 minutes per channel during continuous operation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth style=\"text-align: left; width: 28.0128%; height: 19.5938px;\"\u003eSample conditions\u003c\/th\u003e\n\u003ctd style=\"text-align: left; width: 69.665%; height: 19.5938px;\"\u003eFlow \u0026gt;50 mL\/s; temperature 10–45°C; pressure 10–100 kPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth style=\"text-align: left; width: 28.0128%; height: 19.5938px;\"\u003eAmbient conditions\u003c\/th\u003e\n\u003ctd style=\"text-align: left; width: 69.665%; height: 19.5938px;\"\u003e5–45°C; accuracy decreases above 40°C; \u0026lt;85% RH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth style=\"text-align: left; width: 28.0128%; height: 19.5938px;\"\u003eReagent consumption\u003c\/th\u003e\n\u003ctd style=\"text-align: left; width: 69.665%; height: 19.5938px;\"\u003eThree reagents; approximately 1 L of each per month\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth style=\"text-align: left; width: 28.0128%; height: 19.5938px;\"\u003eOutput\u003c\/th\u003e\n\u003ctd style=\"text-align: left; width: 69.665%; height: 19.5938px;\"\u003e4–20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth style=\"text-align: left; width: 28.0128%; height: 19.5938px;\"\u003eAlarms\u003c\/th\u003e\n\u003ctd style=\"text-align: left; width: 69.665%; height: 19.5938px;\"\u003eBuzzer and normally open relay contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth style=\"text-align: left; width: 28.0128%; height: 19.5938px;\"\u003eCommunications\u003c\/th\u003e\n\u003ctd style=\"text-align: left; width: 69.665%; height: 19.5938px;\"\u003eRS485 Modbus RTU; LAN, Wi-Fi or 4G options\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth style=\"text-align: left; width: 28.0128%; height: 19.5938px;\"\u003ePower\u003c\/th\u003e\n\u003ctd style=\"text-align: left; width: 69.665%; height: 19.5938px;\"\u003e220 VAC ±10%, 50 Hz; approximately 50 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth style=\"text-align: left; width: 28.0128%; height: 19.5938px;\"\u003eDimensions\u003c\/th\u003e\n\u003ctd style=\"text-align: left; width: 69.665%; height: 19.5938px;\"\u003e720 × 460 × 300 mm (H × W × D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth style=\"text-align: left; width: 28.0128%; height: 19.5938px;\"\u003eMounting hole dimensions\u003c\/th\u003e\n\u003ctd style=\"text-align: left; width: 69.665%; height: 19.5938px;\"\u003e665 × 405 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4\u003eFAQs\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eHow often does the analyzer measure?\u003c\/strong\u003e\u003cbr\u003eDuring continuous operation, the specified sampling period is 10 minutes per channel.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan it monitor multiple sample streams?\u003c\/strong\u003e\u003cbr\u003eConfigurations with one to six channels are available.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes it need reagents?\u003c\/strong\u003e\u003cbr\u003eYes. The analyzer uses three reagents that must be replenished.\u003c\/p\u003e","brand":"Sper Scientific","offers":[{"title":"Default Title","offer_id":68217370083552,"sku":"870018","price":12497.5,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/online-industrial-silicate-analyzer-870018-5209569.jpg?v=1793360777"},{"product_id":"industrial-online-phosphate-analyzer-870019","title":"Online Industrial Phosphate Analyzer","description":"\u003ch1\u003eThe Sper Scientific 870019 Industrial Online Phosphate Analyzer continuously monitors phosphate concentration in process water using photoelectric colorimetry.\u003c\/h1\u003e\n\u003cp\u003e\u003cstrong\u003eIt supports water chemistry monitoring in power plants and chemical processing facilities.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe color LCD displays current readings and trend curves, with approximately one month of historical data available for review. A 4–20 mA output and RS485 communication connect the analyzer to monitoring equipment. Automatic calibration and optional multi-channel configurations support routine monitoring of one or more sample streams.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAutomated phosphate measurement with optical detection\u003c\/li\u003e\n\u003cli\u003eColor display with real-time trend curves\u003c\/li\u003e\n\u003cli\u003eAutomatic calibration\u003c\/li\u003e\n\u003cli\u003eOne to six sample channels available by configuration\u003c\/li\u003e\n\u003cli\u003eAudible and relay alarms\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003ePart number\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e\u003cstrong\u003e870019\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eMethod\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003eMolybdenum yellow photoelectric colorimetry\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eMeasurement ranges\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e0–2,000 µg\/L or 0–10 mg\/L; select when ordering\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eAccuracy\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e±1% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eRepeatability\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e±1% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eDrift\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e≤±1% of full scale per 24 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eResponse\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003eInitial response 4 minutes; at least 98% response in 6 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eSampling period\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e3 minutes per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eSample conditions\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003eFlow \u0026gt;2 mL\/s; temperature 10–45°C; pressure 10–100 kPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eAmbient conditions\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e5–45°C; reduced accuracy above 40°C; \u0026lt;85% RH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eReagent\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003eOne type; approximately 3 L per month\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eOutput\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e4–20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eAlarms\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003eBuzzer and normally open relay contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eCommunication\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003eRS485 Modbus RTU; LAN, Wi-Fi or 4G options\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003ePower\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e220 VAC ±10%, 50 Hz; approximately 50 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eDimensions\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e720 × 460 × 300 mm (H × W × D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eMounting hole dimensions\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e665 × 405 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4\u003eFAQs\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eHow often does the analyzer measure?\u003c\/strong\u003e\u003cbr\u003eThe specified sampling period is 3 minutes per channel.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan it monitor multiple sample streams?\u003c\/strong\u003e\u003cbr\u003eConfigurations with one to six channels are available.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes it need reagent?\u003c\/strong\u003e\u003cbr\u003eYes. The analyzer uses one type of reagent that must be replenished.\u003c\/p\u003e","brand":"Sper Scientific","offers":[{"title":"Default Title","offer_id":68217987268832,"sku":"870019","price":12497.5,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/online-industrial-phosphate-analyzer-870019-5753256.jpg?v=1793360776"},{"product_id":"online-industrial-sodium-analyzer","title":"Online Industrial Sodium Analyzer","description":"\u003ch1\u003eThe Sper Scientific 870020 Industrial Online Sodium Analyzer continuously monitors sodium ions in water and process solutions.\u003c\/h1\u003e\n\u003cp\u003e\u003cstrong\u003eIts low-concentration measurement capability supports water chemistry monitoring in power generation, water treatment and industrial processing.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe analyzer combines a sodium measuring electrode with an automatic sample flow system and alkalization system. An English-language display presents readings, while isolated analog outputs and RS485 communication connect the analyzer to monitoring equipment. Historical measurements can be reviewed as a trend curve.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eContinuous online sodium monitoring\u003c\/li\u003e\n\u003cli\u003eAutomatic temperature compensation\u003c\/li\u003e\n\u003cli\u003eAutomatic sample flow and pressure compensation\u003c\/li\u003e\n\u003cli\u003eAdjustable high and low alarm thresholds\u003c\/li\u003e\n\u003cli\u003eApproximately one month of historical data and a 200-message event log\u003c\/li\u003e\n\u003cli\u003eOne to six sample channels available by configuration\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003ePart number\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e\u003cstrong\u003e870020\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eSodium measurement ranges\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e0–100 µg\/L; 0–2,300 mg\/L; 0.00–8.00 pNa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eResolution\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e0.1 µg\/L; 0.01 mg\/L; 0.01 pNa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eBasic error\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e±2.5%; temperature ±0.3°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eTemperature compensation\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003eAutomatic, 0–60°C; referenced to 25°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eRepeatability\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e±2.5% of reading (electronic unit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eStability\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e±2.5% of reading per 24 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eSample temperature\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e0–60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eData storage\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003eApproximately one month, one point every five minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eIsolated outputs\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e0–10 mA, load \u0026lt;1.5 kΩ; 4–20 mA, load \u0026lt;750 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eOutput current error\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e≤±1% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eAlarm contacts\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003eNormally open; 250 VAC, 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eCommunication\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003eRS485 Modbus RTU; LAN, Wi-Fi or 4G options\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003ePower\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e220 VAC ±10%, 50 ±1 Hz; approximately 50 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eDimensions\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e720 × 460 × 300 mm (H × W × D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eMounting hole dimensions\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e665 × 405 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003e\u003c\/h4\u003e\n\u003ch4\u003eFAQs\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eWhat does the analyzer measure?\u003c\/strong\u003e\u003cbr\u003eSodium ions in water and process solutions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan it monitor multiple sample streams?\u003c\/strong\u003e\u003cbr\u003eConfigurations with one to six channels are available.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow are readings transmitted?\u003c\/strong\u003e\u003cbr\u003eThrough an isolated analog output or RS485 communication.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Sper Scientific","offers":[{"title":"Default Title","offer_id":68285151510752,"sku":"870020","price":8747.5,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/online-industrial-sodium-analyzer-870020-5068526.jpg?v=1793360776"},{"product_id":"industrial-glass-ph-electrode","title":"Online Industrial Glass pH Electrode - Waste Water (PTFE)","description":"\u003ch1\u003eThe Industrial Glass pH electrode supports continuous online monitoring in wastewater and environmental applications.\u003c\/h1\u003e\n\u003cp\u003eThis cable-connected combination electrode features a low-resistance sensing membrane and a ceramic-infiltrated sand core junction. Its pressure-resistant design is suited to industrial pH measurement and long-term online monitoring.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMeasures pH from 0 to 14\u003c\/li\u003e\n\u003cli\u003eCable-type connection\u003c\/li\u003e\n\u003cli\u003eLow-resistance glass sensing membrane\u003c\/li\u003e\n\u003cli\u003eCeramic-infiltrated sand core junction\u003c\/li\u003e\n\u003cli\u003eDesigned for environmental and wastewater monitoring\u003c\/li\u003e\n\u003cli\u003eCan be used with a 316L stainless steel or PPS sheath\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cmeta charset=\"utf-8\"\u003e870002-PHG1\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH range\u003c\/td\u003e\n\u003ctd\u003e0–14 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature range\u003c\/td\u003e\n\u003ctd\u003e0–80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure resistance\u003c\/td\u003e\n\u003ctd\u003e0.3 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection type\u003c\/td\u003e\n\u003ctd\u003eCable type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJunction material\u003c\/td\u003e\n\u003ctd\u003eCeramic-infiltrated sand core\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eEnvironmental protection and wastewater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Sper Scientific","offers":[{"title":"Default Title","offer_id":68290605875424,"sku":"870002-PHG1","price":150.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/online-industrial-glass-ph-electrode-waste-water-ptfe-870002-phg1-4359559.png?v=1793360775"},{"product_id":"online-industrial-pressure-sensor-0-100-mpa-4-20-ma","title":"Online Industrial Pressure Sensor, 0–100 MPa, 4–20 mA","description":"\u003ch1\u003eHigh-Accuracy Industrial Pressure Measurement for Water Treatment and Process Control\u003c\/h1\u003e\n\u003cp\u003eThe Sper Scientific 870023-PS Pressure Sensor is an industrial silicon pressure transmitter designed for monitoring compatible liquids in water treatment, wastewater and industrial process applications. Its 316L stainless steel wetted parts, 4–20 mA output and rugged stainless steel housing support reliable integration with process control systems.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePressure measurement range: 0–100 MPa\u003c\/li\u003e\n\u003cli\u003eAccuracy: ±0.25% FSO\u003c\/li\u003e\n\u003cli\u003e4–20 mA analog output with 24 VDC supply\u003c\/li\u003e\n\u003cli\u003e316L stainless steel wetted parts and silicon pressure membrane\u003c\/li\u003e\n\u003cli\u003e200% FS overload pressure and 250% FS burst pressure\u003c\/li\u003e\n\u003cli\u003eDIN 43650 electrical connector and IP65 protection\u003c\/li\u003e\n\u003cli\u003eBSP 1\/4-inch male process connection or customized connection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eIndustrial automation, water and wastewater treatment, chemical processing and compatible liquid pressure monitoring.\u003c\/p\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eProduct\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e\u003cstrong\u003eSper 870023-PS Pressure Sensor\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eMeasurement media\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003eLiquids compatible with 316L stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eMeasuring range\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e0–100 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eOverload pressure\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e200% FS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eBurst pressure\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e250% FS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003ePower supply\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eOutput signal\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e4–20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eZero offset\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e1% FSO maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eAccuracy\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e±0.25% FSO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eLong-term zero stability\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e0.15% FSO\/year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eLoad resistance\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e250–1150 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eStorage temperature\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e−30 to +80°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eOperating temperature\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e−40 to +120°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eProcess connection\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003eBSP 1\/4-inch male or customized\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eElectrical connection\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003eDIN 43650\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eEnvironmental protection\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003ePressure membrane\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003eSilicon\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eWetted parts\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e316L stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eHousing\u003c\/th\u003e\n\u003ctd style=\"text-align: left;\"\u003e304 stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Sper Scientific","offers":[{"title":"Default Title","offer_id":68312327192800,"sku":"870023-PS","price":237.5,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/online-industrial-pressure-sensor-0-100-mpa-4-20-ma-870023-ps-5901014.jpg?v=1793360774"},{"product_id":"online-trace-dissolved-oxygen-sensor-for-high-purity-water","title":"Online Trace Dissolved Oxygen Sensor for High-Purity Water","description":"\u003ch1\u003eThis industrial dissolved oxygen sensor monitors trace oxygen in high-purity water, boiler feedwater and power plant water systems.\u003c\/h1\u003e\n\u003cp\u003eDesigned for low-level dissolved oxygen measurement, the sensor uses a polarographic electrode with a platinum cathode, silver\/silver chloride anode and silicone rubber membrane. It detects oxygen concentrations as low as 0.1 µg\/L at 20 °C, helping operators monitor water conditions in oxygen-sensitive processes.\u003c\/p\u003e\n\u003cp\u003eA 316L stainless steel body and double-shielded 5 m cable suit industrial installations. Temperature compensation elements are available to match the connected analyzer. The sensor requires polarization before use and a continuous flow of sample water across the membrane.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eTrace dissolved oxygen measurement for high-purity water applications\u003c\/li\u003e\n\u003cli\u003ePolarographic sensing with a platinum cathode and Ag\/AgCl anode\u003c\/li\u003e\n\u003cli\u003eSilicone rubber membrane supported by steel gauze\u003c\/li\u003e\n\u003cli\u003e316L stainless steel electrode body\u003c\/li\u003e\n\u003cli\u003eDouble-shielded 5 m cable\u003c\/li\u003e\n\u003cli\u003eTemperature compensation options for compatible analyzers\u003c\/li\u003e\n\u003cli\u003eFlow cell included\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003e\u003cstrong\u003eProduct\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e\u003cstrong\u003e870007-PWDO\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eMeasurement principle\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003ePolarographic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003ePublished measuring ranges\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e0–100 µg\/L; 0–20 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eDetection limit\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e0.1 µg\/L at 20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eResponse time\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e≤3 minutes to 90% of final reading at 20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eSample water temperature\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e0–60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eElectrode body\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e316L stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eElectrolyte\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e0.1 M potassium chloride (KCl)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eMembrane\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003eSilicone rubber with steel gauze\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eTemperature compensation options\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003ePt100, Pt1000, 22 kΩ or 2.252 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eCable\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e5 m, double-shielded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003ePolarization voltage\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e0.7 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003ePolarization time\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003eMore than 8 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eMinimum sample flow velocity\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e5 cm\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003e\n\u003cbr\u003eFAQs\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eWhere is this sensor used?\u003c\/strong\u003e\u003cbr\u003eIt is intended for trace oxygen monitoring in thermal power plants, demineralized water systems and boiler feed water.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow long does the sensor need to polarize?\u003c\/strong\u003e\u003cbr\u003eThe specified polarization time is more than 8 hours.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the sample need to flow?\u003c\/strong\u003e\u003cbr\u003eYes. The specified minimum sample velocity is 5 cm\/s across the sensing membrane.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I select the temperature compensation element?\u003c\/strong\u003e\u003cbr\u003eMatch it to your analyzer's input requirements. \u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"Sper Scientific","offers":[{"title":"Default Title","offer_id":68326668763360,"sku":"870007-PWDO","price":1325.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/online-trace-dissolved-oxygen-sensor-for-high-purity-water-870007-do8f-2606511.jpg?v=1793360766"},{"product_id":"online-ultra-pure-water-ph-and-temperature-electrode","title":"Online Ultra-Pure Water pH and Temperature Electrode","description":"\u003ch1\u003eThe 870002-PHA Ultra-Pure Water pH electrode measures pH and temperature in pure-water and high-purity water systems.\u003c\/h1\u003e\n\u003cp\u003eA polymer-filled reference system helps stabilize the reference junction potential. Its large-area diaphragm sits close to the glass sensing membrane, creating a short, consistent path between the reference junction and measuring element. This arrangement supports a fast response and helps reduce the effect of changes in sample flow on measurement stability.\u003c\/p\u003e\n\u003cp\u003eControlled electrolyte diffusion limits the amount of electrolyte entering the sample, making the electrode suitable for pure-water monitoring. Applications include thermal power plant water systems, where a suitable flow-through cell is required.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDesigned for pure water and high-purity water applications\u003c\/li\u003e\n\u003cli\u003eMeasures pH and temperature with a compatible analyzer\u003c\/li\u003e\n\u003cli\u003ePolymer-filled reference junction for stable potential\u003c\/li\u003e\n\u003cli\u003eLarge-area diaphragm positioned close to the glass sensing membrane\u003c\/li\u003e\n\u003cli\u003eLow-noise cable connection\u003c\/li\u003e\n\u003cli\u003eQuarter-turn twist-lock mounting for insertion and removal\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003e\u003cstrong\u003ePart number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e\u003cstrong\u003e870002-PHA\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eMeasurement parameters\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003epH and temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003epH range\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e0.0–14.0 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eTemperature range\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e0–60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003ePublished pH accuracy\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e±0.1 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003ePublished temperature accuracy\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e±0.5 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eSlope\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e≥96%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eZero point\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e7 pH ±0.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eTemperature compensation options\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e10 kΩ, 2.252 kΩ, Pt100 or Pt1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eMounting\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003eTwist-lock with 3\/4 in. rear-facing threads\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eElectrical connection\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003eLow-noise cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eApplication\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003ePure water and high-purity water monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eFAQs\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eWhy is this electrode suited to pure water?\u003c\/strong\u003e\u003cbr\u003eIts polymer-filled reference system and closely spaced reference junction help maintain stable measurements while controlling electrolyte diffusion into the sample.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow is the electrode installed?\u003c\/strong\u003e\u003cbr\u003eIt uses twist-lock mounting and 3\/4 in. rear-facing threads. A quarter turn inserts or removes the electrode from the process connection.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan it connect to any pH analyzer?\u003c\/strong\u003e\u003cbr\u003eConfirm the electrode input and temperature compensation requirements of your analyzer before ordering.\u003c\/p\u003e","brand":"Sper Scientific","offers":[{"title":"Default Title","offer_id":68328591655136,"sku":"870002-PHA","price":362.5,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/online-ultra-pure-water-ph-and-temperature-electrode-870002-pha-5629704.jpg?v=1793360772"},{"product_id":"online-industrial-desulfurization-ph-sensor","title":"Online Industrial Desulfurization pH Sensor","description":"\u003ch1\u003eThis pH sensor monitors process liquids in flue gas desulfurization and industrial wastewater treatment systems.\u003c\/h1\u003e\n\u003cp\u003eA gel-filled electrode and flat glass sensing surface are designed for contaminated process liquids. The sensing surface helps resist fouling and mechanical impact, while the PPS body provides a durable housing for industrial installations. The sensor measures across a 0–14 pH range and operates at temperatures from 0 to 95 °C.\u003c\/p\u003e\n\u003cp\u003eUpper and lower 3\/4 in. NPT threads support process mounting. A direct low-noise cable provides a 5 m connection to a compatible pH analyzer. Optional 2.252 kΩ or Pt1000 temperature compensation elements can be specified to match the analyzer's input requirements.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDesigned for flue gas desulfurization and wastewater pH monitoring\u003c\/li\u003e\n\u003cli\u003eFlat glass sensing surface for fouling and impact resistance\u003c\/li\u003e\n\u003cli\u003eGel-filled electrode construction\u003c\/li\u003e\n\u003cli\u003ePPS body for industrial service\u003c\/li\u003e\n\u003cli\u003eUpper and lower 3\/4 in. NPT mounting threads\u003c\/li\u003e\n\u003cli\u003e5 m low-noise cable\u003c\/li\u003e\n\u003cli\u003eOptional temperature compensation matched to the analyzer\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable style=\"width: 100%; height: 245.125px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 10px;\"\u003e\n\u003ctd style=\"text-align: left; width: 29.4775%; height: 10px;\"\u003e\u003cstrong\u003ePart number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: left; width: 67.8514%; height: 10px;\"\u003e\u003cstrong\u003e870002-PHC8X\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"text-align: left; width: 29.4775%; height: 19.5938px;\"\u003epH range\u003c\/td\u003e\n\u003ctd style=\"text-align: left; width: 67.8514%; height: 19.5938px;\"\u003e0–14 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"text-align: left; width: 29.4775%; height: 19.5938px;\"\u003eOperating temperature\u003c\/td\u003e\n\u003ctd style=\"text-align: left; width: 67.8514%; height: 19.5938px;\"\u003e0–95 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"text-align: left; width: 29.4775%; height: 19.5938px;\"\u003ePressure resistance\u003c\/td\u003e\n\u003ctd style=\"text-align: left; width: 67.8514%; height: 19.5938px;\"\u003e0.6 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"text-align: left; width: 29.4775%; height: 19.5938px;\"\u003eBody material\u003c\/td\u003e\n\u003ctd style=\"text-align: left; width: 67.8514%; height: 19.5938px;\"\u003ePPS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"text-align: left; width: 29.4775%; height: 19.5938px;\"\u003eZero point\u003c\/td\u003e\n\u003ctd style=\"text-align: left; width: 67.8514%; height: 19.5938px;\"\u003e7 pH ±0.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"text-align: left; width: 29.4775%; height: 19.5938px;\"\u003eProcess connections\u003c\/td\u003e\n\u003ctd style=\"text-align: left; width: 67.8514%; height: 19.5938px;\"\u003eUpper and lower 3\/4 in. NPT threads\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"text-align: left; width: 29.4775%; height: 19.5938px;\"\u003eCable length\u003c\/td\u003e\n\u003ctd style=\"text-align: left; width: 67.8514%; height: 19.5938px;\"\u003e5 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"text-align: left; width: 29.4775%; height: 19.5938px;\"\u003eElectrical connection\u003c\/td\u003e\n\u003ctd style=\"text-align: left; width: 67.8514%; height: 19.5938px;\"\u003eDirect low-noise cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"text-align: left; width: 29.4775%; height: 39.1875px;\"\u003eTemperature compensation options\u003c\/td\u003e\n\u003ctd style=\"text-align: left; width: 67.8514%; height: 39.1875px;\"\u003e2.252 kΩ or Pt1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"text-align: left; width: 29.4775%; height: 39.1875px;\"\u003eApplications\u003c\/td\u003e\n\u003ctd style=\"text-align: left; width: 67.8514%; height: 39.1875px;\"\u003eFlue gas desulfurization, industrial wastewater treatment and environmental water treatment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003e\u003c\/h4\u003e\n\u003ch4\u003eFAQs\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eWhat applications is this sensor designed for?\u003c\/strong\u003e\u003cbr\u003eIt is intended for pH measurement in flue gas desulfurization, industrial wastewater treatment and environmental water treatment processes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow does it connect to the process?\u003c\/strong\u003e\u003cbr\u003eThe sensor has upper and lower 3\/4 in. NPT threads and a direct 5 m low-noise cable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes it require a pH analyzer?\u003c\/strong\u003e\u003cbr\u003eYes. Select a compatible analyzer and match the temperature compensation input to the configured sensor.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Sper Scientific","offers":[{"title":"Default Title","offer_id":68329083306208,"sku":"870002-PHC8X","price":600.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/online-industrial-desulfurization-ph-sensor-870002-phc8x-9020936.jpg?v=1793360773"},{"product_id":"glass-ph-electrode-for-high-purity-water","title":"Online Glass pH Electrode for High-Purity Water","description":"\u003ch1\u003eThis glass pH electrode is designed for online monitoring of pure water and high-purity water.\u003c\/h1\u003e\n\u003cp\u003eThe 870002-PHG2 is a combination electrode with a low-resistance sensing membrane for pure-water applications in water treatment and power generation. Its internal resistance is specified at no more than 80 MΩ at 25 °C, and its ceramic sand-core junction provides the electrolyte interface with the sample.\u003c\/p\u003e\n\u003cp\u003eA cable connection links the electrode to a compatible pH analyzer. The GPE200 measures from 0 to 14 pH, operates at 0–80 °C and has a specified pressure resistance of up to 0.3 MPa. Gel or solid electrolyte configurations are available within this electrode family.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDesigned for continuous online pH monitoring in high-purity water\u003c\/li\u003e\n\u003cli\u003eLow-resistance glass sensing membrane\u003c\/li\u003e\n\u003cli\u003eCombination electrode construction\u003c\/li\u003e\n\u003cli\u003eCeramic sand-core junction\u003c\/li\u003e\n\u003cli\u003eCable-type connection to a compatible analyzer\u003c\/li\u003e\n\u003cli\u003eCan be used with a compatible 316L stainless steel or PPS sheath\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003e\u003cstrong\u003ePart number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e\u003cstrong\u003e870002-PHG2\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003eGPE200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003epH range\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e0–14 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eOperating temperature\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e0–80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003ePressure resistance\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e≤0.3 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eConnection type\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003eCable type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eInternal resistance at 25 °C\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e≤80 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eZero point\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e7 pH ±0.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eSlope\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e≥95% of theoretical slope\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eJunction material\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003eCeramic-infiltrated sand core\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eElectrode body\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003eGlass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eApplication\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003eHigh-purity water\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003e\n\u003cbr\u003eFAQs\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the GPE200 intended for?\u003c\/strong\u003e\u003cbr\u003eThe GPE200 is designed for pH measurement in high-purity water systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat are its measurement and temperature ranges?\u003c\/strong\u003e\u003cbr\u003eIt measures 0–14 pH and operates at 0–80 °C.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs a pH analyzer required?\u003c\/strong\u003e\u003cbr\u003eYes. The electrode connects by cable to a compatible pH analyzer. \u003cbr\u003e\u003c\/p\u003e","brand":"Sper Scientific","offers":[{"title":"Default Title","offer_id":68329456107744,"sku":"870002-PHG2","price":150.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/online-glass-ph-electrode-for-high-purity-water-870002-phg2-6539677.jpg?v=1793360772"},{"product_id":"online-industrial-insertion-glass-ph-electrode","title":"Online Industrial Insertion Glass pH Electrode","description":"\u003ch1\u003eThis industrial glass pH electrode is available in wastewater and high-purity water configurations for continuous online monitoring.\u003c\/h1\u003e\n\u003cp\u003eChoose the wastewater version for environmental and wastewater treatment applications, or select the high-purity water version for pure-water monitoring. Both configurations combine a glass sensing membrane with a ceramic sand-core junction and cover a 0–14 pH range at operating temperatures from 0 to 80 °C.\u003c\/p\u003e\n\u003cp\u003eThe wastewater version has an internal resistance of up to 250 MΩ at 25 °C, while the high-purity water version is specified at up to 80 MΩ. Both use insertion-type connections and can be installed with a compatible 316L stainless steel or PPS sheath.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eTwo application-specific configurations\u003c\/li\u003e\n\u003cli\u003eGlass combination electrode design for online pH measurement\u003c\/li\u003e\n\u003cli\u003eLow-resistance sensing membrane\u003c\/li\u003e\n\u003cli\u003eCeramic sand-core junction\u003c\/li\u003e\n\u003cli\u003eGel or solid electrolyte technology, depending on configuration\u003c\/li\u003e\n\u003cli\u003eInsertion-style connection for compatible process installations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth scope=\"col\" style=\"text-align: left;\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\" style=\"text-align: left;\"\u003eWastewater\u003c\/th\u003e\n\u003cth scope=\"col\" style=\"text-align: left;\"\u003eHigh-Purity Water\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003ePart number\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e870002-PHC6\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e870002-PHC8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eApplication\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003eEnvironmental and wastewater monitoring\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003eHigh-purity water monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003epH range\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e0–14 pH\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e0–14 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eOperating temperature\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e0–80 °C\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e0–80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003ePressure resistance\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e≤0.3 MPa\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e≤0.3 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eConnection type\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003eInsertion type\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003eInsertion type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eInternal resistance at 25 °C\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e≤250 MΩ\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e≤80 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eZero point\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e7 pH ±0.3\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e7 pH ±0.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eSlope\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e≥95% of theoretical slope\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e≥95% of theoretical slope\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eJunction material\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003eCeramic-infiltrated sand core\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003eCeramic-infiltrated sand core\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eElectrode body\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003eGlass\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003eGlass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003c\/h3\u003e\n\u003ch3\u003eAccessories\u003c\/h3\u003e\n\u003cp\u003eCompatible 316L stainless steel and PPS sheaths can be used for installation.Please  \u003ca href=\"https:\/\/sperdirect.com\/pages\/contact-us\"\u003eContact us\u003c\/a\u003e to confirm the correct sheath, holder and analyzer connection.\u003c\/p\u003e\n\u003ch4\u003eFAQs\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eWhich version should I choose?\u003c\/strong\u003e\u003cbr\u003eChoose Wastewater for environmental and wastewater monitoring. Choose High-Purity Water for pure-water applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat differs between the two versions?\u003c\/strong\u003e\u003cbr\u003eThe intended application and internal resistance differ. The wastewater version is specified at ≤250 MΩ at 25 °C, while the high-purity water version is specified at ≤80 MΩ.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs an analyzer required?\u003c\/strong\u003e\u003cbr\u003eYes. Use a compatible pH analyzer and connection arrangement for the selected electrode.\u003c\/p\u003e","brand":"Sper Scientific","offers":[{"title":"Wastewater","offer_id":68330126180576,"sku":"870002-PHC6","price":162.5,"currency_code":"USD","in_stock":true},{"title":"High-Purity Water","offer_id":68330126213344,"sku":"870002-PHC8","price":162.5,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/online-industrial-insertion-glass-ph-electrode-870002-phc6-3397081.jpg?v=1793360772"},{"product_id":"online-industrial-pure-water-ph-and-temperature-sensor","title":"Online Industrial Pure Water pH and Temperature Sensor","description":"\u003ch1\u003eIndustrial Pure Water pH Sensor for Online Process Monitoring\u003c\/h1\u003e\n\u003cp\u003eThe Sper Scientific pure water pH sensor provides online pH and temperature measurement for pure and high-purity water systems. It measures from 0 to 14 pH and 0 to 60°C, with specified accuracies of ±0.1 pH and ±0.5°C. Applications include industrial water treatment, process water monitoring and power plant water analysis.\u003c\/p\u003e\n\u003cp\u003eA polymer-filled reference system and large-area diaphragm help stabilize the junction potential in low-conductivity water. The close spacing between the reference junction and sensing glass is designed to reduce changes in diffusion potential caused by variations in flow. This supports consistent readings in demanding pure water applications.\u003c\/p\u003e\n\u003cp\u003eThe 3-in-1 electrode integrates pH measurement, temperature compensation and solution grounding. Upper and lower 3\/4 NPT threads support installation in tanks or pipelines with suitable fittings, while a directly attached low-noise cable connects the sensor to a compatible pH transmitter.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDesigned for pure and high-purity water pH monitoring\u003c\/li\u003e\n\u003cli\u003ePolymer-filled reference system with a large-area junction\u003c\/li\u003e\n\u003cli\u003eIntegrated temperature compensation and solution grounding\u003c\/li\u003e\n\u003cli\u003eAg\/AgCl reference electrode and a slope of at least 96%\u003c\/li\u003e\n\u003cli\u003eUpper and lower 3\/4 NPT threads for flexible process installation\u003c\/li\u003e\n\u003cli\u003eLow-noise cable for connection to a compatible transmitter\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"text-align: left;\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eSper part number\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e870002-PHP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eMeasurement\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003epH and temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003epH range\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e0–14 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eTemperature range\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e0–60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003epH accuracy\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e±0.1 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eTemperature accuracy\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e±0.5°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eElectrode slope\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e≥96%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eZero point\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003epH 7 ±0.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003ePressure rating\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e0.6 MPa (6 bar)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eInternal impedance\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e≤250 MΩ at 25°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eSensor design\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e3-in-1 electrode with temperature compensation and solution grounding\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eProcess connection\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003eUpper and lower 3\/4 NPT pipe threads\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eElectrical connection\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003eDirectly attached low-noise cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eTemperature compensation\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e10 kΩ, 2.252 kΩ, Pt100 or Pt1000, depending on configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eReference\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003ePolymer-filled reference system with Ag\/AgCl electrode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eTemperature compensation elements are available in 10 kΩ, 2.252 kΩ, Pt100 and Pt1000 configurations. Confirm the required element and cable termination for your transmitter when ordering.\u003c\/p\u003e\n\u003cp\u003eSelect a compatible pH transmitter, mounting fittings and calibration buffers for the installation. Please \u003ca href=\"https:\/\/pt2ygnm1xcw5p9lg-35682484360.shopifypreview.com\/pages\/contact-us\"\u003econtact us\u003c\/a\u003e if you need assistance.\u003c\/p\u003e\n\u003ch4\u003eFAQs\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eIs this sensor designed for high-purity water?\u003c\/strong\u003e\u003cbr\u003eYes. Its polymer-filled reference and large-area diaphragm are designed to support stable pH measurement in pure and high-purity water.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat instrument is required to read the sensor?\u003c\/strong\u003e\u003cbr\u003eUse a compatible pH transmitter with inputs matched to the electrode and its temperature compensation element.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow is it installed?\u003c\/strong\u003e\u003cbr\u003eThe upper and lower 3\/4 NPT threads support tank or pipeline mounting with suitable fittings. Keep the installation within the 0–60°C temperature range and 0.6 MPa pressure rating.\u003c\/p\u003e","brand":"Sper Scientific","offers":[{"title":"Default Title","offer_id":68330871488736,"sku":"870002-PHP","price":137.5,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/online-industrial-pure-water-ph-and-temperature-sensor-870002-php-8075070.jpg?v=1793360767"},{"product_id":"trace-dissolved-oxygen-sensor-for-high-purity-water","title":"Online Trace Dissolved Oxygen Sensor for High-Purity Water","description":"\u003ch1\u003eThis industrial dissolved oxygen sensor monitors trace oxygen in high-purity water, boiler feedwater and power plant water systems.\u003c\/h1\u003e\n\u003cp\u003eDesigned for low-level dissolved oxygen measurement, the sensor uses a polarographic electrode with a platinum cathode, silver\/silver chloride anode and silicone rubber membrane. It detects oxygen concentrations as low as 0.1 µg\/L at 20 °C, helping operators monitor water conditions in oxygen-sensitive processes.\u003c\/p\u003e\n\u003cp\u003eA 316L stainless steel body and double-shielded 5 m cable suit industrial installations. Temperature compensation elements are available to match the connected analyzer. The sensor requires polarization before use and a continuous flow of sample water across the membrane.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eTrace dissolved oxygen measurement for high-purity water applications\u003c\/li\u003e\n\u003cli\u003ePolarographic sensing with a platinum cathode and Ag\/AgCl anode\u003c\/li\u003e\n\u003cli\u003eSilicone rubber membrane supported by steel gauze\u003c\/li\u003e\n\u003cli\u003e316L stainless steel electrode body\u003c\/li\u003e\n\u003cli\u003eDouble-shielded 5 m cable\u003c\/li\u003e\n\u003cli\u003eTemperature compensation options for compatible analyzers\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003e\u003cstrong\u003eProduct\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e\u003cstrong\u003e870007-DO8F\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eMeasurement principle\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003ePolarographic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003ePublished measuring ranges\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e0–100 µg\/L; 0–20 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eDetection limit\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e0.1 µg\/L at 20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eResponse time\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e≤3 minutes to 90% of final reading at 20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eSample water temperature\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e0–60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eElectrode body\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e316L stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eElectrolyte\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e0.1 M potassium chloride (KCl)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eMembrane\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003eSilicone rubber with steel gauze\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eTemperature compensation options\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003ePt100, Pt1000, 22 kΩ or 2.252 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eCable\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e5 m, double-shielded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003ePolarization voltage\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e0.7 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003ePolarization time\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003eMore than 8 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eMinimum sample flow velocity\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e5 cm\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eTemperature compensation elements are available in Pt100, Pt1000, 22 kΩ and 2.252 kΩ configurations. Match the element to the connected analyzer's input requirements when ordering.\u003c\/p\u003e\n\u003cp\u003eThe photo shows a sensor with a flow cell and fittings; please confirm the supplied configuration for your application, and \u003ca href=\"https:\/\/pt2ygnm1xcw5p9lg-35682484360.shopifypreview.com\/pages\/contact-us\"\u003econtact us\u003c\/a\u003e if you need assistance.\u003c\/p\u003e\n\u003ch4\u003eFAQs\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eWhere is this sensor used?\u003c\/strong\u003e\u003cbr\u003eIt is intended for trace oxygen monitoring in thermal power plants, demineralized water systems and boiler feed water.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow long does the sensor need to polarize?\u003c\/strong\u003e\u003cbr\u003eThe specified polarization time is more than 8 hours.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the sample need to flow?\u003c\/strong\u003e\u003cbr\u003eYes. The specified minimum sample velocity is 5 cm\/s across the sensing membrane.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I select the temperature compensation element?\u003c\/strong\u003e\u003cbr\u003eMatch it to your analyzer's input requirements.\u003c\/p\u003e","brand":"Sper Scientific","offers":[{"title":"Default Title","offer_id":68330906681568,"sku":"870007-DO8F","price":1325.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/online-trace-dissolved-oxygen-sensor-for-high-purity-water-870007-do8f-2606511.jpg?v=1793360766"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/collections\/collection-power-plants.jpg?v=1793166910","url":"https:\/\/sper-direct.myshopify.com\/collections\/power-plants.oembed","provider":"Sper Scientific Direct","version":"1.0","type":"link"}