{"product_id":"uv-9000-series-double-beam-spectrophotometers","title":"SPSUV-9000 Series Double Beam UV-Vis Spectrophotometer","description":"\u003ch1\u003eHigh-Performance Spectroscopy with Exceptional Stability and Precision.\u003c\/h1\u003e\n\u003cdiv style=\"text-align: right;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/Free_Shipping4_160x160.png\" alt=\"FREE SHIPPING\" style=\"float: right;\"\u003e\u003c\/div\u003e\n\u003cp\u003eThe SPSUV-9000 Series spectrophotometers are advanced double beam instruments featuring a wide-screen interface and a unique long light path design to ensure superior stability, resolution and accuracy.\u003c\/p\u003e\n\u003cp\u003eEngineered with a 520 mm optical path and housed on a 16 mm die-cast aluminum base, they are ideal for laboratories that demand high-quality and reliable results. Whether used for standard curve analysis, DNA\/protein testing or kinetic studies, the UV-9000 Series offers a versatile and user-friendly experience.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAll units are calibrated and include a factory calibration report.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDouble Beam Optical Design\u003c\/strong\u003e\u003cbr\u003eMinimizes stray light and circuit fluctuations for improved stability and accuracy.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eExtended 520 mm Light Path\u003c\/strong\u003e\u003cbr\u003eEnhances resolution and supports bandwidths down to 0.5 nm.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e16 mm Die-Cast Aluminum Optical Base\u003c\/strong\u003e\u003cbr\u003eProvides high mechanical rigidity and long-term optical stability.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAdvanced Calibration System\u003c\/strong\u003e\u003cbr\u003eAutomatic calibration for wavelength, baseline and dark current ensures consistent performance.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMulti-Functional Interface\u003c\/strong\u003e\u003cbr\u003eSupports wavelength scanning, standard curve, multi-wavelength analysis, kinetics and DNA\/protein testing directly from the unit.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eComprehensive Software Integration\u003c\/strong\u003e\u003cbr\u003eUSB connectivity with included software allows advanced data analysis and remote control. Included full-featured PC software enables spectrum scanning, standard curve generation, kinetics analysis, multi-wavelength testing and DNA\/protein measurement—all from your desktop.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e6-Inch LCD Display\u003c\/strong\u003e\u003cbr\u003eLarge, integrated screen displays spectra and test data in real time without a PC.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eShipping Weight and Dimensions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSPSUV-9000 Series\u003c\/strong\u003e\u003cbr\u003e37 kg \/ 81 lb 9.1 oz\u003cbr\u003e84 × 64 × 44 cm \/ 33 1\/8\" × 25 2\/8\" × 17 2\/8\"\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIncludes:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSpectrophotometer\u003c\/li\u003e\n\u003cli\u003eFactory calibration report\u003c\/li\u003e\n\u003cli\u003e1 cm glass cuvettes (4)\u003c\/li\u003e\n\u003cli\u003e1 cm quartz cuvettes (2)\u003c\/li\u003e\n\u003cli\u003ePC Software\u003c\/li\u003e\n\u003cli\u003ePower cord\u003c\/li\u003e\n\u003cli\u003eUser’s manual\u003c\/li\u003e\n\u003cli\u003eDust cover\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003eSPSUV-9000\u003c\/th\u003e\n\u003cth\u003eSPSUV-9000A\u003c\/th\u003e\n\u003cth\u003eSPSUV-9000S\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptical System\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eDouble Beam (1200 lines\/mm grating)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWavelength Range\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e190–1100 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBandwidth\u003c\/td\u003e\n\u003ctd\u003e1.8 nm\u003c\/td\u003e\n\u003ctd\u003e1 nm\u003c\/td\u003e\n\u003ctd\u003e0.5\/1\/2\/4 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWavelength Accuracy\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e±0.1 nm at D\u003csub\u003e2\u003c\/sub\u003e 656.1 nm; ±0.3 nm across the full range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWavelength Repeatability\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e0.1 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhotometric Accuracy\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e±0.2%T (0–100%T)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhotometric Repeatability\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e≤0.1%T (0–100%T)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhotometric Range\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e-0.3–3 A, 0–200%T, 0–9999 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStability\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e≤0.0005 A\/h at 250 nm and 500 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStray Light\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e≤0.03%T at 220 nm and 360 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eUSB Port \u0026amp; Parallel Port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e320 × 240 Dots LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLight Source\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eW Lamp \u0026amp; D\u003csub\u003e2\u003c\/sub\u003e Lamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Requirements\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eAC 110\/220 V, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eDownloads\u003c\/h4\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/SPSUV-9000_Datasheet.pdf\" rel=\"noopener\" target=\"_blank\"\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/pdf-icon-63x63_480x480.png\" alt=\"PDF\"\u003e \u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/SPSUV-9000_Datasheet.pdf\" rel=\"noopener\" target=\"_blank\"\u003eSPSUV-9000 Product Brochure\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/SPSUV_9000_Series_Users_Manual.pdf\" rel=\"noopener\" target=\"_blank\"\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/pdf-icon-63x63_480x480.png\" alt=\"PDF\"\u003e \u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/SPSUV_9000_Series_Users_Manual.pdf\" rel=\"noopener\" target=\"_blank\"\u003eSPSUV-9000 Users Manual\u003c\/a\u003e\u003c\/p\u003e","brand":"Sper Scientific","offers":[{"title":"SPSUV-9000","offer_id":47259211727072,"sku":"SPSUV-9000","price":6388.0,"currency_code":"USD","in_stock":true},{"title":"SPSUV-9000A","offer_id":47259211759840,"sku":"SPSUV-9000A","price":6856.0,"currency_code":"USD","in_stock":true},{"title":"SPSUV-9000S","offer_id":47259242987744,"sku":"SPSUV-9000S","price":7558.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/8248\/4360\/files\/spsuv-9000-series-double-beam-spectrophotometer-uv-9000-230168.jpg?v=1792535445","url":"https:\/\/sper-direct.myshopify.com\/products\/uv-9000-series-double-beam-spectrophotometers","provider":"Sper Scientific Direct","version":"1.0","type":"link"}